Form Ill, This regulation repealed as on 08.06.2023-- Central Electricity Authority (Measures relating to Safety & Electric Supply) Regulations, 2010: FORM Ill

This regulation repealed as on 08.06.2023-- Central Electricity Authority (Measures relating to Safety & Electric Supply) Regulations, 2010 - Form Ill

Text of form Ill

FORM Ill

FORM Ill ( Installations of voltage exceeding 650V ) Report No. ----- Date oflnspection Date of Last inspection-------,---- SI. Regulation No. Nos 1. Regulation-3 2. · Regu]ation- 12 Requirements Report. ' Is the register of the . designated persons Yes/No properly made and kept up to date duly attested? .. (i) Is/Are there. any visible sigh(s) of Yes/No overloading in respect of any apparatus? (ii) Whether any unauthorised temporary Yes/No installation exist? (iii) Whether the motors and controlling Yes/No equipment are being over hauled periodically and record kept of the same in a register? (iv) Whether the transformer oil samples are Yes/No being tested periodically and results recorded in a register? (v) Whether suitable lightning arrestors have Yes/No been provided near the transformers for protection against lightning? (vi) Whether earth resistance is being Yes/No measured periodically and results recorded in a register? (vii) Any other defect or condition which may Yes/No be a source of danger. If Yes· please explain? (viii) Whether operation and maintenance Yes/No data has been clarified, categorized and computerized for . prompt and easy retrieval? (ix) Whether predictive maintenance is. being Yes/No performed .· for installation of voltage exceeding 650V? (x) Whether residual life assessment and life Yes/No extension progrannnes are being undertaken for installations or equipment of voltage exceeding 650V (applicable for installations or equipment more than } 5 years old)? (xi) Whether all required type and routine tests at Yes/No .factory·done for equipments. Deficiencies and Discrepancies in above test report and results, if any, shall be reported? (xii) Are there deficiencies in . construction with yes/No '----'--------'-------- 351 352 - ---- ------- - 3. 4. 5. 6. Regulation- 13 Regulation- 14 Regulation- 15" .Regulation- 16 THEGAZETTEOFIND~:EXTRAORDmARY reference to Indian Standard requirements. Please soecify. · Give report on condition of service lines, cables; wires, apparatus and such other fittings . placed by the supplier or owner of the premises. If not satisfactorv give details. Whether suitable cut-outs provided by the supplier at the consumer's premises .are within enclosed fire proof receptacle? (i) Whether switches are · provided on live conductors?. (ii) Whether indication of a permanent nature is provided. as per Regulation so as to distinguish neutral conductor from the live conductor?. (iii) Whether a direct line is provided on the neutral in the case of single phase double oole iron clad switches instead of fuse ? (i) Whether earthed terminal is provided by the supplier?. [PART III-SEC. 4] Satisfactory/Not Satisfactory Yes/No Yes/No Yes/No Yes/No Yes/No . (ii) General visible condition of the earthing S~tisfactory/Not arrangement. Satisfactory !-c,---t---,--,----1---cc,---~~----,---~-.,-~,---+---=----'-----,' 7. Regulation- (i) Are bare conductors in building Yes/No 8. 9. 10. 11. 12. 17 inaccessible? Regulation- 18 Regulation- 19 Regulation- 21 Regulation- 22 Regulation- 24 (ii) Whether readily accessible switches have been orovided for rendering them dead? Whether "Danger Notice" in Hindi and the local language of the district and of a design as per relevant Indian · Standard is affixed Yes/No Yes/No permanently in conspicuous position?. · (i) Whether the practice cif working on live Yes/No lines and apparatus is adopted ? If so, have the safety measure been adopted as per Schedule-III? (ii) Whether insulating floor or mats conforming to IS-15652:2006 have been provided? 14. · (iii) Whether identification of panel has been provided on the front and the rear of the panel? Whether flexible cables used for portable or transportable equipment covered under tb.e Regulation, are heavily insulated and adeQuately protected from mechanical injury? .. State · the condition of metallic coverings · orovided for various conductors. Whether the circuits or apparatus intended for operating at differen~ voltage(s) are distinguishable by means of indication(s) of permanent nature?. Yes/No Yes/No Yes/No Satisfactory/Not Satisfactory Yes/No f- ·, I ,. • • J ['ll'l lll-= 4] 13. Regulation- 26 14. Regulation- 27 15. Regulation- 28 . . 16. Regulation~ 34 17. Regulationc 35 3747 Gl/10---45 Whether all circuits and apparatus are so Yes/No arranged that there is no danger of any part(s) becoming accidentally charged to any voltage beyond the limfts ·of voltage for which it/they is/are intended ? (i) In the case of generating stations and Yes/No enclosed sub stations, whether fireabuckets filled with clean dry sand have been conspicuously marked and kept in convenient situations in addition to fire­ extinguishers suitable for dealing with electric fires ? ' · (ii) Whether First Aid Boxes :or cupboards Y es!N9 conspicuously markecl and properly equipped are provided and maintained?. (iii) Is adequate staff trained· in First. 'Aid Yes/No Treatment and fire fighting? (i) Whether instructions in English or Hindi Yes/No and -the local language of the district and. ' where Hindi is the local langua_ge, in English and Hindi, for the resuscitation of persons suffering .from electric shock have been affixed in a "conspicuous place" ? . (ii) Are, the designated persons able to apply Yes/No instructions for resuscitation of persons - suffering from electric shock ? Leakage on premises:. State insulation resistance between conductors ' ----- M Ohms . and earth in Mega Ohms. ..____ (i) · Whether a suitable linked switch, or circuit Yes/No breaker, or emergency tripping device is placed near the point of commencement of supply. so as to be readily accessible and capable of being easily operated to completely isolate the supply? .. . (ii) Whetheri suitable linked switch or a circuit Yes/No breaker to carry and break the full load current on the secondary side of a transformer? .. (iii) Whether every distinct circuit is .protected Yes/No against excess electricity by means of a suitable circuit breaker or cut-out? (iv) Whether linked switch or circuit breaker or -Yes/No · emergency tripping device is provided near the motor or other apparatus at voltage exceeding 650V but not exceeding Yes/No 33kV for controlling supply to>the motor or apparatus? (v) .Whether adequate precautions are taken to Ye~/No ensure that no live parts are so exposed as to cause danger? - . 353 . 354 .I ! 18.. -Regulation~ .. 19. 20. 21. 31 Regulation- 44 Regulation- 45 Regulaeion- 48 THE GAZETTE OF INDIA : EXTRAORDINAR.Y [PART m.-:sEC. 4] (i) Whether clear space of 100 cm is provided. Yes/No in front of the main switchboard?. (ii) Whether the space behind the switchboard Yes/No exceeds 75 cm in width or is less than 20 cm?. (iii) . In case the clear space behind the Yes/No switchboard exceeds 7 5 cm. State whether a passage way from either end of the switchboard to a height of 1.80 meters is provided. (i) Whether all conductors and apparatus Yes/No including live parts thereof are inaccessible? (ii) Whether all windings of motors or other Yes/No apparatus are suitably protected? . (iii) State in case of transformers or reactors or Yes/No switches or static condensers involving the use of more than 2,000 litres of oil in one chamber, if suitable oil soak pits are provided? (iv) Where 9,000 litres or more of oil is used in Yes/No any one oil tank, has provision, been made for draining away or removal of oil which may leak or escape from such tank(s)? (v) Whether trenches inside sub-station Yes/No containing cables 11re filled with non­ inflanunable material or completely covered with non- inflammable slabs? (vi) Are conductors and apparatus so arranged Yes/No that they. may be made dead in sections for carrying out work thereon? Whether protections and interlocks have been Yes/No provided? If not, give details. (i) Have the frames of every generator, Yes/No stationary motor, and so far as practicable portable motor and metallic parts not intended as conductors of all transformers and any other apparatus used for regulating or controlling electricity and all electricity consumin~ apparatus at voltage exceeding 650V but not exceeding 33kV been earthed by two separate and distinct connections with earth ? (ii) Is the earth wire free from any mechanical Yes/Ne damage? (iii) Has the neutral point at the transformer and Yes/No generator been earthed by two separate and distinct connections with earth? '(iv) Have the metal casings or metallic Yes/No coverings containing or protecting any electric supply line or apparatus been ( p j • ' •. ' • J [ '11'1 III-1s11J;s 4 l . 22. · Regulation- 49 . . properly earthed and so joined and - connected across all junction boxes as to make good mechanical ana electrical connections throughout their whole length? (v) Whether earthing has been properly Yes/No executed and has been tested. If yes, give -------Ohms value of earth resistance . Is the outdoor ( except pole type) sub-station Yes/No efficiently protected by fencing not less than . L 8 metres in height? 23 Regulation- (i) Where platform type .construction is used Yes/No 50 for pole type sub-station, has sufficient. space for a man to stand on the platform been provided? (ii) Has hand-rail been provided and connected Yes/No wjth earth (if metallic and if sub-station has not been erected on wooden supports and wooden blateform)? 24. Regulation- 51 Has suitable provision been made for Yes/No immediate and automatic or manual discharge of every static condenser on disconnl)ction- of suooly? 25 l Overhead Lines (i) What is the minimum size of the conductors of overhead lines used ? State the type of conductors. Size of Conductor --- . (ii) Whether clearances above ground of the lowest conductor of overhead lines are as per regulation 58? (iii) On the basis of maximum sag, Whether vertical clearances where the line of voltage exceeding 650V passes above or adjacent to any building or part of a building are as per regulation 61? (iv) On the basis of maximum deflection due to wind pressure, whether horizontal clearances between the nearest conductor and any part of such building are as per regulation 61? (v) Where conductors forming parts of system at different voltages are erected on the same supports, whether adequate provision · has been made as per regulation 62 to guard agilinst danger to linemen and others from the lower voltage system being _charged above its normal working voltage by leakage from or contact with the higher voltage system? (vi) Where overhead lines cross or are in proximity to each other whether they have Yes/No Yes/No Yes/No Yes/No Yes/No 355· . 356 ···_ .. Date:· nre GAZETTE OF INDIA : EXTRAORDINARY [PART m~ssc. 4] . been suitably protected to guard against possibility of their coming in contact with each other as per regulation 69? I (vii) Has every guard wire been properly Yes/No earthed as per regulation 70 at each point at which its electrical continuity is broken? (viii)(a) Whether metal supports of overhead Yes/No lines _and metallic fittings attached thereto are permanently earthed as per regulation 72? (b) Has each stay-wire ( except in case Yes/No where an insulator has been placed in it at a height not less than 3 meters from the ground) been earthed as per .regulation 72? (ix)(a) Whether overhead line is suitably Yes/No protected with a device for rendering the line ,electrically harmless in case it breaks as,perregulation 73? (b) Whether anti-climbing devices have Yes/No been provided at each support as per rc;gulation 73? (~):(a);Has,the owner of overhead lines adopted Yes/No efficient means for diverting to earth any · electrical surges due to lightning in every overhead line which is so exposed as to be liable to injury from lightning • as 'per regulation 7 4? 1 (b} Whether earth lead from the lightning Yes/No arrestors, is connected to a separate earth electrode as per regulation 74? · (xi) Whether unused overhead lines are Yes/No maintained in a safe mechanical condition as perregulation 75? (xii) Whether statutory clearances from Yes/No Authorities i.e. . Forest Department/Railways/ PTCC/Defence (AHQ)/Civil Aviation have been taken as per Indian standard. If yes, enclose copies of .the same. (xii) Any.other remarks. . Signature of the Inspecting· Officer/ Name ________ _ Designation ______ _ File No. _______ _ ' Copy:forwarded to Chief Electrical Inspector for .................... . ---- - - -=-·--------~-- ---- f r ' ,, • ['11'1 III-~ 4] I. 2. 3. 4. 5, Sehedule~v Form for obtaining results during inspection by supplier.ateach'suppiyc11,ointto· consumer [See sub-regulation (2) ofregullitionc,(31)] Name and address of the consumer Details of installation Short circuit fault level of the installation Date-of conunissioning of installation(iµ case of additional supply or reconnection) Results of tests conducted: 357 SI Equipment Test Conducted TestResults ·aemarks No 1 · Linked Switch with fuse( s) 1 a Isolator 2 Circuit Breaker SI.No. ------ Circuit I3reaker Control Circuits ( i)Mechanical operation (ii) Rating of fuse (iii) Contact ofblades i) Mechanical,operation ii) Remote operation iii) Local operation iv) Measurement of contact resistance v) Interlocking with' earth ,switch vi) Interlocking ,with CB vii) IR V aluys Open condition Closed condition (1) Rating ofCircuitBreaker (a) Type (b) Voltage (c) Normal Current ( d) Rupturing capacity (2) IR Values Open condition Close condition (3) Contact Resistance : ( 4) Mechanical operation: (5) Remote opera1ion: ( 6) .Local operation: (7) Interlocking with Jsolator: (8) Interlocking with earth switch (9) Alarm and Trip for OTI/WTI/Buchholz/PRV (10) Earth FaultRelay: (11) Over current Relav : ·Smooth/troublesome . Amp. Ftill/Partial OK/not:OK 0K/notOK OK/nobOK. --~-----------micro Ohm OK/not,QK OK/not.OK ------ -----· -M ,Ohm Ph~Ph Ph~E ----- --------------------- -----------· ·-- kV ------- Amps · ---- ---KA· --------------M Ohm Ph-Ph Ph.E · . hm/ -------------micro o . , • Instant.smooth/time. · gap{ Sec:) 0K/not,0K 0K/not•0K 0K/not0K OK/not0K OK/not·0K OK/riot,QK 0K/riot0K 358 3 Transformer SI. No.---- . 4 DGSet SI. Nos. for 1. Alternator: 2. Engine: 5 Cables Size: Sq. mm 6 Earthing; TilE <;;AZETTE OF INDIA : EXTRAORDINARY [l'ART III-SEC. 4] (12) Under Voltage Relay: (13) SF6 pressure alarm and trip operation test (A) Insulation Resistance Values: 1. HTtoLT: 2. HT to Earth: 3. LT to Earth: (B) Break down Voltage Test Oil Sample-I(Toj,) Oil Sample - II (Bottom) (C) Vector Group Test: (D) Polarity Tests: (E) Magnetizing Balance: (F) Tan Delta Test ( as per capacity) (G) Oil level in conservator Tank: (H) Oil level in breather cup: (I) OTI/WTI settings : ( J) OTI/Vy'TI alarm and trip operation (K) Operation of Buchholz relay : (L) Operation of PRY (M) Oil leakage (N) Interlock of door switch for dry transformer (0) Clearances for Side clearance : Between two Transformers:(P) Body earth resistance Neutral earth resistance (A) Interlocking with other Supply Sources: (B) Body-earth resistance Neutral earth resistance . (A) Insulation.Resistance Values: · · 1. Ph-Ph: 2. ~h - Earth : 3. Ph - Earth + other Ph : (B) Bending Radius; . B) A) Metal and Size of Earth Strips: Type of Earthings: . ( 1) Plate Earthing: (2) Pipe Earthing: (3) Counter poise Earthing (C) Values of Earth resistances of OK/not OK ·oKJnotOK ----Mohm --------------M ohm ------··· ----M ohm --···-----·•--kV kV OK/not OK OK/not OK OK/not OK OK/not OK OK/not OK OK/not OK NT---- 0c NT----0c OK/not OK . OK/notOK OK/not OK OK/not OK OK/not OK ---------Cms ----------Meters ---------· Ohm' , Ni-·•Ohm . N2---0hm OK/not OK ---Ohm N,~--Ohm N2---0hm --------- M Ohm ·---------M Ohm ---------M Ohm OK/not OK Cu/ Al/GI --- Sq. Yes/No Yes/No Yes/No mm N 1 ----ohm N2 ----ohm • ' . ' ' • • • \ [ <!T'1 III-~ 4 l 359 earth electrodes for (R) ---ohm (Y) ---ohm (1) Reactor Neutral: (B)----ohm (2) LAs: ohm ohm (3). Structure: (4) Frames/Bodies of ohm Equipment: (5) Motors: 7 Potential (i) Ratio test OK:/notOK Transformer (ii) Polarity test OK/not OK (iii) BDVofoil kV - • (iv) IR test (R) P-E-------M Ohm (Y) P-E-------M Ohm 8. -Current (i) (B) P~E-------M Ohm Ratio test OK/not OK Transformer (ii) Po lantytest OK/not OK (iii) BDVofoil -- -------kV (iv) IR test (R) P-E-------M Ohm (Y) P-E-------M Ohm 9. Transmission (i) (B) P-E-~-----M Ohm Physical condition of OK/not OK line conductor/tower . (ii) Check of tower accessories OK/not OK (iii) .Tower footing resistance Ohm (iv) .Conductor ccmtinuity test QK/notOK (v) Check of ground clearance OK/not OK (vi) Check of electrical clearance OK/not OK along the route General Observations : . . SI.No. Item Observations l. Check of required phase to phase, phase to ground and - .sectional clearance. 2. Check of equipment lay out and over all installation details. . 3. Test of resistance of earth mat or earth electrodes as applicable. 4. Check.of consumer's pre-commissioning test reports -of individual equipment. - .· 5. Check of manufacturer's routine/type test reports of individual equipment. '6. Whether Inspector's approval if applicable is obtained? r· - -· ·-· ~ - ------ ---- 360 7. 8. TIIE GAZETTE OF INDIA : EXTRAORDINARY [PART III-SEC. 4] Whether owner) s self certification about compliance with The Regulations is obtained? ,· Generalobservation,and views (specific deviation from , the requirements of the Regulations shall be clearly brought out). Name, Signature and Seal of the Authority Schedule-VI Form for notice in respect of failure of supply [S.ee sub•regulation (3) of regulation (39)]· · (1) Nameandaddress of the supplier (2) Date,andtime of failure of supply (3} Arem,•affected due to failure (4) ·· Causes ofTailure (5) Probable.time forrestoration of supply (6) Additionalinformation, if any Date: Place: Time: (Name, Signature, Designation and Sealof Authoity) .l ·~-----------------~~--~- -·-·-- J Schedule-Vil Minimum safety working clearances where electricity at voltage exceeding 650 V is supplied, converted, transformed or used (See suh•regulation (2)(iii) of regulati!)n (44)) Highest System Voltage (kV) 12 36 72.5 }45 245 420 800 Safety Working Clearance (Metres) 2.6 2.8 3.1 3.7 4.3 6.4 10.3 ( 1) The above values are valid for altitude not exceeding 1000 m. A correction factor of 1.25 per cent per 100 m is to be applied for increasing the clearance for altitude more than 1000 m and upto 3000 m; · (2) The above safety working clearances are based on an insulation height of 2.44 m which is the height of lowest point on the insulator, wheieit meets the earthed metal, from the ground; (3) "Safety Working Clearance" is the minimum clearance to be maintained in air between the live part of the equipment on one hand and earth or another piece of equipment or conductor on which it is necessary to carry out the work, on the · other; ( 4) The "Highest System Voltage" is defined as the highest rms phase to phase voltage which occurs under normal operating conditions at any time and at any point of the system. It excludes voltage transients (such as those due to system switching) and temporary · voltage variations due to abnormal system conditions (such as those due to fault conditions or the sudden disconnection oflarge loads). 3747 Gl/10-46 361 362 THE GAZETTE OF INDIA : EXTRAORDINARY [PART III--SEC. 4] Schedule-VIII Minimum safety clearances to be maintained for bare conductors or live parts of any apparatus.in out-door sub-stations, excluding overhead lines ofHVDC istallations [See sub•regulation (5) of regulation (44)] . S.No. DC Voltage (kV) Pole to Earth. Clearance Ground Clearance (Metres) (Metres) . I. lOOkV 1.17 4.55 2. 200kV 1.80 5.65 3. 300kV 2.45 6.75 . . 4. 400 kV. 3.04 8.00 5. 500kV 3.65 9.00 . 6. 600kV 3.98 JO.I 7. 800kV 5.3 I 1.2 (1) The above ground clearances are not applicable to equipment that are housed within fence or a building and where access is prevented under er\eigised condition through a suitable safety interlocking scheme; (2) The above pole to earth c.learances · are · for conductor-structure electrode configuration using gap factor k equal to 1.35. ..r,.· (3) It is recognised that within a substation many different types . of electrode configurations shall be there with different values ofk, therefore, the above clearance shall be modified based upon the values of gap factor for a particular electrode configuration subjected to the minimum ground clearance. (4) Clearance shaJl be provided for electrical apparatus so that sufficient space is available for easy operation and maintenance without any hazard to the operating and maintenance personnel working near the equipment_ and for ensuring adequate ventilation. • • • ,. [ [ "ll'l IIl-l§!U,l" 4 l Schedule-IX Form for reporting failure of Transformers or Reactors of rating 20 MV A/MVAR and above [See sub-regulation (8) of regulation (46)] (1) Type of Equipment (Transformer or Reactor) (2) Capacity (MV A/MV AR) (3) Location (Address) . ( 4) Owner and address of owner (5) Date of failure { 6) Year of manufacture (7) Date ofinstallation (8) Make (9) Reasons for failure ( 10) Measures being taken to avoid recurrence of failure Date: (Signature and name of Manager/Executive Engineer of the installation) 363 -~-'=.::.-. 364 TI-IE GAZETTE OF INDIA : EXTRAORDINARY , [PART .UI~SEC. 4] 'Schedille-X Ground, Vertical and Horizontal clearances [See sub-regulation (6) of regulation 58, sub-regulation {SJ Qf rsegulation (60) and · sub-regulation (5) o!.regulation .(;1] • · GCL ,. • .. .. • •• _. • • • • .. , M11xm. VCL Daflectlcl'i "l '~ I •• .. I • .. • VC.L GCL: Cleai·ai1cH as pel' Regulation 59 VCL: C'lea1·ances as per.Regulation 6(1.,t 61. HCL: C'lea1:n11ces as pel' Regulation 60 ... ~ 61 !! Qffld1atar j J,atlfll!l~i . . ! . . MCL, • ·--=-.. .. .. . GCL ' ' t D

Previous and next

All provisions of This regulation repealed as on 08.06.2023-- Central Electricity Authority (Measures relating to Safety & Electric Supply) Regulations, 2010

Questions people ask

Is form Ill of This regulation repealed as on 08.06.2023-- Central Electricity Authority (Measures relating to Safety & Electric Supply) Regulations, 2010 still in force?

No repeal of This regulation repealed as on 08.06.2023-- Central Electricity Authority (Measures relating to Safety & Electric Supply) Regulations, 2010 is recorded.