Rule 52, Atomic Energy (Factories) Rules, 1996: LADDERS
Atomic Energy (Factories) Rules, 1996 - Rule 52
Text of rule 52
LADDERS
52. LADDERS.-
(1) Every ladder shall be of good construction, sound material and of adequate strength for
the purpose for which it is used. The rungs shall be parallel, level and uniformly spaced at
30 cm.
(2) Ladders shall be inspected regularly and repaired immediately. No ladder with defective
or missing rungs shall be used. Wooden ladders shall not be painted. For preserving the
material from deterioration linseed oil or clear varnish shall be used.
(3) No portable single ladder shall be over 9 m in length while the width between side rails in
rung ladder shall in no case be less than 28 cm for ladder up to and including 3 m in
length. For longer ladders this width shall be increased at least 20 mm for each additional
metre of length. Uniform step spacing shall not exceed 30 cm.
(4) All ladders with spreading bases such as step and trestle ladders shall be equipped with
rigid spreads or some other means to prevent their premature opening or closing.
(5) Ladders shall be in a safe position before being climbed. The best angle for a ladder is 75
with the horizontal i.e., the distance of the base of the ladder from the wall, pole structure
etc., as the case may be shall be 1/4th its length.
(6) A ladder shall be stored upon brackets and in sheltered locations.
(7) A ladder shall not be placed upon a box, barrel, or other movable insecure object and
against a round or angular pillar such as pipe or narrow steel section etc.
(8) Two ladders must not be spliced together as far as possible. When it is inevitable they
shall be tied together properly to ensure rigidity. Extra parallel members at the point of
splicing may be added to each of the main members of the ladder. Two ladders shall not
be spliced together to provide access to a greater height than when a single ladder is used.
Atomic Energy Factory Rules, 1996
82
Rules 52-53
(9) Bamboo ladders shall be provided with twisted wire loops enclosing both longitudinal
members to prevent them from opening outwards. However, such ladders where
longitudinal members are reinforced with metal/wire loops shall not be used when
working on electrical circuits.
(10) Metal ladders with insulating rubber shoes shall only be used for working with electrical
lines or in places where they may come in contact with such wires.
(11) No worker shall work from a plank placed on the rungs of ladders.
(12) All permanently installed vertical ladders above a height of 3 m shall have manguards
provided.