Rule 52, Atomic Energy (Factories) Rules, 1996: LADDERS

Atomic Energy (Factories) Rules, 1996 - Rule 52

Text of rule 52

LADDERS

52. LADDERS.- (1) Every ladder shall be of good construction, sound material and of adequate strength for the purpose for which it is used. The rungs shall be parallel, level and uniformly spaced at 30 cm. (2) Ladders shall be inspected regularly and repaired immediately. No ladder with defective or missing rungs shall be used. Wooden ladders shall not be painted. For preserving the material from deterioration linseed oil or clear varnish shall be used. (3) No portable single ladder shall be over 9 m in length while the width between side rails in rung ladder shall in no case be less than 28 cm for ladder up to and including 3 m in length. For longer ladders this width shall be increased at least 20 mm for each additional metre of length. Uniform step spacing shall not exceed 30 cm. (4) All ladders with spreading bases such as step and trestle ladders shall be equipped with rigid spreads or some other means to prevent their premature opening or closing. (5) Ladders shall be in a safe position before being climbed. The best angle for a ladder is 75 with the horizontal i.e., the distance of the base of the ladder from the wall, pole structure etc., as the case may be shall be 1/4th its length. (6) A ladder shall be stored upon brackets and in sheltered locations. (7) A ladder shall not be placed upon a box, barrel, or other movable insecure object and against a round or angular pillar such as pipe or narrow steel section etc. (8) Two ladders must not be spliced together as far as possible. When it is inevitable they shall be tied together properly to ensure rigidity. Extra parallel members at the point of splicing may be added to each of the main members of the ladder. Two ladders shall not be spliced together to provide access to a greater height than when a single ladder is used. Atomic Energy Factory Rules, 1996 82 Rules 52-53 (9) Bamboo ladders shall be provided with twisted wire loops enclosing both longitudinal members to prevent them from opening outwards. However, such ladders where longitudinal members are reinforced with metal/wire loops shall not be used when working on electrical circuits. (10) Metal ladders with insulating rubber shoes shall only be used for working with electrical lines or in places where they may come in contact with such wires. (11) No worker shall work from a plank placed on the rungs of ladders. (12) All permanently installed vertical ladders above a height of 3 m shall have manguards provided.

Previous and next

All provisions of Atomic Energy (Factories) Rules, 1996

Questions people ask

Is rule 52 of Atomic Energy (Factories) Rules, 1996 still in force?

No repeal of Atomic Energy (Factories) Rules, 1996 is recorded.