Rule 56, GUWAHATI BUILDING BYELAWS: Septic tanks
GUWAHATI BUILDING BYELAWS - Rule 56
Text of rule 56
Septic tanks
56. Septic tanks: - Where a septic tank is used for sewage disposal, the location,
design and construction of the septic tank shall conform to requirement of
subsequent clause.
57.1 Location of septic tank’s subsurface absorption system: A subsoil dispersion
system shall not be closer than 18 m from any source of drinking water, such as
well, to mitigate the possibility of bacterial pollution of water supply. It shall
also be as far removed from the nearest habitable building as economically
feasible but not closer than 6 m. to avoid damage to the structure.
57.2 Requirement: -
(a) Dimensions of septic tanks- Septic tanks shall have minimum width of
0.75 m, minimum depth of one metre below water level and a minimum
liquid capacity of one cubic metre. Length of tanks shall be 2 to 4 times
the width; detail of which is given in Table-3
(b) Septic tanks may be constructed of brickwork, stone masonary concrete
or other suitable material as approved by the Authority.
(c) Under no circumstance should effluent from a septic tank be allowed
into an open channel, drain or body of water without adequate treatment;
(d) Minimum nominal diameter of pipe shall be 100 mm. Further at
junctions of pipes in manholes, direction of flow from a branch
connection should not make an angle exceeding 45 degree with the
direction of flow in the main pipe;
(e) The gradients of land drains, under drainage as well as the bottom of
dispersion trenches and soak ways should be between 1:300 and 1:400.
(f) Every septic tank shall be provided with ventilating pipe of atleast 50
mm diameter. The top of the pipe shall be provided with a suitable cage
of-mosquito-proof-wire-mesh.
The ventilation pipe shall extend to a height, which would cause no
smell nuisance to any building in the area. Generally, the ventilating
pipe may extend to a height of about 2 m when the septic tank is atleast
15 m away from the nearest building and to a height of 2 m above the
top of the building when it is located closer than 15 metres.
(g) When the disposal of septic tank effluent is to seepage pit, may be of
any suitable shape with the least cross-sectional dimension of 90 cm and
not less than 100 cm in depth below the invert level of the inlet pipe.
The pit may be filled with stone, brick or concrete blocks with dry open
joins which should be backed with atleast 7.5 cm of clean coarse
NEW REVISED BUILDING BYELAWS FOR GUWAHATI METROPOLITAN AREA-2006
Guwahati Metropolitan Dev. Authority Page No. [35]
aggregate. The lining above the inlet level should be finished with
mortar. In the case of pits of large dimensions, the top portion may be
narrowed to reduce the size of the RCC cover slab, where no lining is
used, specially near trees, the entire pit should be filled with loose
stones. A masonry ring may be constructed at the top of the pit to
prevent damage by flooding of the pit by surface run off. The inlet pipe
may be taken down a depth of 90 cm from the to as an anti mosquito
measure.
(h) When the disposal of septic tank effluent is to a dispersion trench, the
dispersion trench shall be 50 to 100 cm deep and 30 to 100 cm wide
excavated to a slight gradient and shall be provided with 15 to 25 cm of
washed gravel or crushed stones. Open jointed pipes placed inside the
concrete and shall have minimum internal diameter of 75 to 100 cm. No
dispersion trench should be longer than 30 m and trenches should not be
placed closer than 1.8 m.
NEW REVISED BUILDING BYELAWS FOR GUWAHATI METROPOLITAN AREA-2006
Guwahati Metropolitan Dev. Authority Page No. [36]
Chapter-IV
58. Setback line, yard width, coverage and other particulars will be according
to the standards as below:
58.1 MINIMUM PLOTSIZE FOR RESIDENTIAL USE
Density Plot Size
(a)
(b)
(c)
High
Medium
Low
15 lessa i.e 200 sq.mt
01 Katha i.e. 268 sq.mt.
01 Katha 05L 335 sq.mt.
However within Guwahati Municipal Corporation area the Authority may
allow to relax the provisions regarding plot size with the following conditions
on FAR and coverage on appeal before appropriate authority.
High density Minimum plot size 10 Lessa
F.A.R. 100
Coverage 50%
Medium density Minimum plot size 15 Lessa
F.A.R. 125
Coverage 50% for RCC
55% For Assam Type
58.2 MINIMUM WIDTH OF PLOT
(a)
Upto 15 Lessa i.e. 200 sq. mt 7.5 mtrs
(b) 15 Lessa to 1 K-10L i.e. 400 sq. mt 10 mtrs
(c) 1K-10L to 2K-10L i.e. 400 sq. mt to 670 sq. mt 11.5 mtrs
(d) More than 2K-10L i.e. 670 sq. mt 12 mtrs
58.3 SETBACK REGULATIONS
(a) Minimum setback of the building or the structure from the
prescribed street line-
(i) FRONT SETBACK
Every building fronting a street shall have a front space
from the prescribed street line forming an integral part of
the site as below-
NEW REVISED BUILDING BYELAWS FOR GUWAHATI METROPOLITAN AREA-2006
Guwahati Metropolitan Dev. Authority Page No. [37]
Width of
street
fronting the
plot as per
Master Plan
Minimum front open space
Height of the building
Upto 9.6
Metres*
9.6 to 15.8
Metres*
Above 15.8
Metres*
Upto 6.6
Metres
3.0 Metres 4.5 Metres 6.0 Metres
Upto 15
Metres
3.0 Metres 6.0 Metres 7.5 Metres
Above 15
Metres
3.0 Metres 7.5 Metres 9.0 Metres
* Assuming 0.6 metre to be the plinth height from the
average level of the ground, around and contiguous to the
building.
In case of building abutting two or more streets
the wider street shall be considered for determining
building height and other regulation and setback will be
as per CL 36.
Front setback of all categories of building shall be
as per 58.3 (i).
(ii) SIDE SETBACK
For high density zones side setbacks shall be 1.5 metres.
For medium density zones side setbacks shall be 1.5
mertres
For low density zone side setbacks shall be 1.8 metres.
(iii) Rear setback for all density zone shall be 3.0 metres.
(iv) For building above 12 m. additional setback will be required as
per Cl. 37 (A) 1.
(v) However for multistoreyed residential buildings all set back
norms of multistoreyed apartment will be applicable.
58.4 REGULATIONS FOR APARTMENT BUILDINGS
Height of
building
Minimum
plot size
Minimum
front set
back
Minimum
rear set back
Minimum
side set back
Apartment
upto 12 m.
3 K. 4.5 m. 3.6 m. 2.4 m.
Apartment
above 12
m. height
4 K. 6 m. 3.6 m. 2.4 m.
Mixed use
building of
residential
apartment
and
commercial
above 15
m.
5 K. 6 m. 3.6 m. 2.4 m.
A plot abutting a street with a width of above 15 metres, the
NEW REVISED BUILDING BYELAWS FOR GUWAHATI METROPOLITAN AREA-2006
Guwahati Metropolitan Dev. Authority Page No. [38]
minimum front set back shall be calculated according to the width of the
abutting street as given in the clause No. 58 (3)(i)
The side and rear set backs for buildings above 12 m. will be as per Cl.
37. (A) (i).
58.5 REGULATIONS FOR COMMERCIAL USE IN COMMERCIAL
ZONE
Minimum plot size -167.4 sq. mtr.
Minimum width of plot - 7.5 m
(i) Setback upto the height of 12 mtr.
Minimum front set back- 3.0 mtrs with 1.5mtr. cantilever in
upper floor
Minimum side set back- a minimum of 1(one) mtr has to be
maintained in each side which can be relaxed
to only one side if the adjoining plot owner
agrees to have a common wall with his
building.
Minimum rear set back
upto plot depth of 18 mtrs - 1.5 mtrs.
above plot depth of 18mtrs - 3.0 mtrs with maximum 1.5 mtrs
projection on the upper floors.
If any part of the ground floor or any other upper floor is used for
residential purpose or for human habitation the side set back of the
building shall be as per the high density residential zones.
A plot abutting a street with a width of above 15 mtrs the front setback
shall be calculated according to the width of the abutting street as
given in the clause no. 58.3(i)
(ii) Additional rear and side setback for a building with a height of
above 12 metres.
12 m upto 15 m. –Rear setbak – 3 mtr. & side setback - 1.5 m.
- Side and rear setback should be
increased by 0.3 metres for every 1.5
mtres of additional height of the
building in addition to the setbacks
already prescribed for a building of 15
metres height upto a maximum of 1.5
metres of additional set backs on both
rear and sides.
58.6 REGULATIONS FOR WHOLESALE USE IN WHOLESALE
COMMERCIAL ZONE
Minimum plot size - 670 sq.mtr
Minimum plot width - 15 metres
Minimum front set back - 6 mtrs.
Maximum height - (a) 15.0 mtr for building of wholesale
use
(b) For other building the height will
be given as per CL. 37.
NEW REVISED BUILDING BYELAWS FOR GUWAHATI METROPOLITAN AREA-2006
Guwahati Metropolitan Dev. Authority Page No. [39]
Minimum side set back - 1.8 mtr on one side and the setback on the
other side will be 3.6 mtr
Rear Set back - 3.0 mtr.
58.7 REGULATION FOR PUBLIC AND SEMI PUBLIC USE IN PUBLIC
AND SEMI PUBLIC ZONE
Minimum plot size - 400 sq.mtr.
Minimum setback
Front set back - 6.0 metres.
Side & rear - 3.0 metres.
58.8 REGULATION FOR INDUSTRIAL ZONE
Light Medium
Requirements Area In
sq.mtrs.
Width in
mtrs
Area in sq.
metres
Width in
metres
(1) Minimum size of
plot
744.00 15.5 1800 27.5
(2) Minimum set back
of all structure/
building or the
structure from the
prescribed street
line set
Front 6.00 Front 9.0
(3) Minimum Rear 6.0 Rear 6.0
Set back side 3.0 side 6.0
If any structure or building
is permitted for human
habitation under provision
of these rule the yard
conditions shall be same as
prescribbed for medium
density residential zone
If any structure or building is
permitted for human
habitation under the
provision of these rules the
yard conditions shall be
same as prescribed for
medium density residential
zone
(4) Maximum height 15 mtrs
58.9 REQUIREMENTS FOR SPECIAL TYPES OF BUILDINGS
(To be applicable for all zones where the particular use is permissible)
(A) NURSING HOMES/ HOSPITALS
(In all zones where it is permitted/ permissible on appeal)
Minimum plot size - 1338 sq. mtr i.e. 1 Bigha
Minimum setback
Front setback - 9 metres
(a) Rear & side - 4.5 metres
(B) PLACE OF WORSHIP
(Applicable for new proposals)
Minimum plot size- 804 sq. mtr i.e. 3 K
Minimum setback
NEW REVISED BUILDING BYELAWS FOR GUWAHATI METROPOLITAN AREA-2006
Guwahati Metropolitan Dev. Authority Page No. [40]
Front setback - 7.5 metres
(a) Rear - 5.0 metres
(b) Side - 3.0 metres
(C) CINEMA HALL AND AUDITORIUM
Minimum plot size - 1860 sq. mtr i.e.1B-3K-9L
Minimum setback
(a) Front set back - 9.0 metres
(b) Rear & side - 4.5 metres
(D) FILLING STATION
(a) Minimum Plot size- 31 mtr x 17 mtrs
(b) Petrol filling station with servicing bed
Minimum Plot size- 37 mtr x 31 mtrs
*(E) SCHOOL BUILDING
Minim
um Plot
size
Maximu
m
Coverage
Minimu
m Front
set back
Minimu
m side
setback
Minimu
m rear
setback
(a) Pre
nursery/
Nursery
535 sq.
mt 02
katha
50% 6.0 mtr 3.0 mtr 3.0 mtr
(b) Primary 804 sq.
mt 03
katha
50% 7.5 mtr 3.0 mtr 3.0 mtr
(c) High
School
2677
sq. mt
02
bigha
30% 10 mtr 3.0 mtr 3.0 mtr
(d) College 4015
sq. mtr
03
bigha
30% 10 mtr 3.0 mtr 3.0 mtr
Organised parking- 20% of the total plot area
Organised recreational open space- 20% of the total plot area
* For Govt. institutions regulations adopted by Education
Department will be followed.
“U” type development
As an encouragement for developing U type commercial complexes /
residential / apartment / group housing the setbacks of sides and rear, excluding
the front setback, can be reduced provided.
(a) The area so saved is transferred to the central area / space or court
yard.
(b) The minimum open space on sides and rear except front shall be
1.5mtrs for building of 12 m height & 2.4m for building above 12 m
(c) Minimum plot size for performing such development shall be 500 Sq.
mtrs.
NEW REVISED BUILDING BYELAWS FOR GUWAHATI METROPOLITAN AREA-2006
Guwahati Metropolitan Dev. Authority Page No. [41]
58.9. (i) The area of the plot for a multistoreyed building other than apartment
of 15 metre height and above shall be - 04 K.
58.9. (ii) The floor area ratio (FAR), the coverage and the width of the
access road for the various type of building is as given below
Residential
(a) The FAR for different widths of access road shall be :-
Road Width (Metre) Maximum FAR
Upto 4.4 100
4.5 to 7.9 175
8.0 or more 200
(b) The coverage for different plot sizes should be: -
Plot size (M2) Maximum coverage (%)
Upto 500 55
Above 500 50
(c) Commercial and Resi-Commercial (Mixed Use)
Minimum road width 3.6
m. to 9 m
Plot size (M2) Maximum FAR Maximum coverage (%)
Upto 300 200 55
301 to 500 200 50
Above 500 225 45
(d) Others
Type of building Maximum FAR Maximum
coverage (%)
Minimum
width-of
access-road in
M
a)Apartment
(i) upto 12 m
height
(ii) above 12 m
height
175
200
40
40
6.6M
8 M
b) Institutional 175 40 9M
c)-Wholesale
commercial
150 45 9M
d) Other public
& semi public
area
175 40 9M
e)-Nursing home 150 40 9M
f) Industrial 150 40 9M
g) place of
worship
(applicable for
new proposals)
125 40 9M
h) Cinema hall /
multiplex &
125 40 9M
NEW REVISED BUILDING BYELAWS FOR GUWAHATI METROPOLITAN AREA-2006
Guwahati Metropolitan Dev. Authority Page No. [42]
auditorium and
indoor stadium
i) Multiplex The FAR and Coverage stipulations shall be similar to
Commercial and Residential-Commercial (Mix use) of
plot size above 500 metres square, with additional
requirement of parking, over and above parking norms
for that building, similar to the requirement of parking
space required for Cinema Halls based on the number
of seats.
j) Multilevel
Car Parking
i) Minimum plot size -1000 sq. m.
ii) Maximum Coverage -66%
iii) FAR Plot Size
1000 sq. m –2000 sq. m -175
Above 2000 sq. m -200
iv) No restriction on no. of basement with 100%
basement subject to structural safety with
basement to be flushed with ground level.
v) Maximum height be restricted to permissible
height and minimum setbacks be as per
commercial building.
For other type of buildings not specifically mentioned above,
the Authority will decide considering the similarity of the building
with the above use.
58.10.1 Maximum mezzanine area allowed is 33% of plinth area which will
not be counted in FAR if it has access from only lower floor. Height of
the mezzanine - 2.2m minimum to 2.7m maximum however, no
additional area above 33% shall be allowed in mezzanine floor even if
FAR is available.
58.10.2 Basement shall not be counted for F.A.R. calculations for
following uses-
(i) Air conditioning and other machines used for services
and utilities of the building.
(ii) Parking places and garages.
(iii) If the basement is used for office or commercial purpose
it shall be counted in F.A.R.
(iv) While calculating the FAR following areas are exempted
from FAR calculation-
Lift, Staircases and Entrance Lobby area of the
Cantilever Cupboard Self subject to a maximum of 2% of
the area from which these are projected, Sentry Box and
Guard Room (Maximum of 3.5 sq. metre each), Care
Taker Room (Maximum 8 sq. metre), Rain Harvesting
Structures and Un-Enclosed Covered Parking Places.
(v) For calculation of exemption area from FAR under clause
58.10.2 the entrance lobby will mean the lobby
immediately in front of staircase and lift subject to a
maximum exempted area of 12 sq. m. per staircase/lift for
each floor.
58.10.3
NEW REVISED BUILDING BYELAWS FOR GUWAHATI METROPOLITAN AREA-2006
Guwahati Metropolitan Dev. Authority Page No. [43]
(a) Partial unenclosed balcony projections for a length ¼ of
the building length/breadth in upper floors upto a
minimum setback line of 1.5 mtr from plot boundary will
be allowed subject to a maximum width of 1.5 mtr.
(b) The projection of cantilever or cupboard or shelve upto
0.75 mtr in depth shall be permitted and exempted from
covered area calculation. This will be allowed only from
the first floor and shall not exceed 2.0 mtr per habitable
room and cupboard under windows.
(c) A canopy not exceeding 4.5 mtr in length and 2.5 mtr in
width in the form of unenclosed cantilever over the main
entrance with a clear height of 2.2 mtr below the canopy
shall be allowed.
(d) Light and ventilation:- When any habitable room
excepting bath, W.C, store room, kitchen and dining are
not abutting on either the front side or rear open space it
shall abut in an interior open space where minimum
width will be 3 mtr.
For ventilating the spaces for W.C, bath, store,
kitchen and dining if not opening on any open space,
shall open on the ventilation shaft the size of which is
given below-
Height of
building
Minimum
area of shaft
Minimum
width of
shaft
(1) W.C,
bath &
store
(a) upto 18 m
(b) above 18
m.
3 sq. m
6.25 sq. m
2 m
2.5 m
(2)
Kitchen
& dining
(a) upto 18 m
(b) above 18
m
6.25 sq. m
9 sq. m
2.5 m
3 m
58.10.4 The parking space to be provided in the building shall be as per
the details given in the Appendix- I. In providing the parking,
care has to be taken that 50% of the open space is left for
landscaping and not counted for in the parking calculations. At
least 25% of the open space reserved as organised open space
which should be clearly shown in the service plan.
For calculation of car space the following shall be considered.
Area of each car space-
(i) Basement parking-30 sq. mtr
(ii) Stilt-25 sq. mtr
(iii) Open Parking-20 sq. mtr
In addition to parking requirement specified in Appendix – I, for
multistoreyed apartments, commercial complex and nursing homes
following parking provisions have to be made in these complexes for
visitors/shoppers, which should be easily accessible from the approach
road.
Multistoreyed apartment -1 car/4 dwelling units.
NEW REVISED BUILDING BYELAWS FOR GUWAHATI METROPOLITAN AREA-2006
Guwahati Metropolitan Dev. Authority Page No. [44]
Multistoreyed shopping/
Office complex -1 car/100 sq.mtr. of area
-1 scooter/50 sq.mtr. of area
Nursing home -1 car/5 cabin of single accommodation.
-1 Scooter/5 bed accommodation
This area is inclusive of the circulation and driveway etc. as
provided in National Building Code 2005. For actual size of a car
space (excluding circulation and driveway area) to be taken as 13.75
sq. metre.
58.10.5 No extension of existing building will be allowed by the
Authority if the parking provision required for the whole
building as per new Byelaws is not made available in the new
proposal.
58.11 ADDITIONAL REQUIREMENTS FOR MULTISTOREYED
AND SPECIAL TYPE OF BUILDINGS
(A) Service plan showing the following details-private water,
sewerage disposal system and detail of building services where
required by the Authority shall be made available on scale not
less than 1:100 and it should also include the following.
(a) For outlet from the soakpit to municipal drain if
provided an intermediate treatment chamber
should be installed details of which is to be shown
in service plan subject to approval of the
Authority and provision made under Sec. 64
wherever required.
(b) Garbage vet.
(c) Organised open space as specified by clause
58.10(4).
Detail of building services include
(i) Air conditioning system, if any.
(ii) Detail of exits including provisions of
ramps, etc. for hospital and special risk
building
(iii) Location of generator, transformer and
switch gear.
(iv) Smoke exhauster system and fire alarm, if
any.
(v) Location of centralized control of all fire
alarm systems, if any.
(vi) Location and dimension of static water
storage and pump house.
(vii) Location of fire protection installation,
sprinklers, wetrisers, etc, if any. .
N.B.-These should generally be as per
specifications of National Building Code
2005.
NEW REVISED BUILDING BYELAWS FOR GUWAHATI METROPOLITAN AREA-2006
Guwahati Metropolitan Dev. Authority Page No. [45]
(viii) Size (width) of main and alternate
staircase along with balcony approach,
corridor and ventilated lobby approach.
(ix) In case of nursing homes and hospitals,
detail of incinerator for treatment of
hospital waste is to be submitted and
clearance from appropriate authority under
Assam Health Establishment Act 1993 and
1995 will be required before its clearance
by GMDA.
(x) Detail provisions made of conservation
and harvesting of rain water to be
provided as required under CL. 65 of this
Byelaws.
(B) (i) NOC from the State Fire Service shall be required for
building above the height of 15.8 m.
(ii) In addition to this NOC mentioned in (i) above it will
be mandatory to provide all provision of Part (4) of NBC
2005, for fire and life safety in the building.
(C) Specifications:- General specifications of the proposed
construction giving type and grade of material of public
use along with soil testing report and structural details as
given in Chapter- VI duly signed by architect/ engineer/
supervisor/ group should accompany the application for
buildings above three storey.
(D) Supervision: Applications shall be further accompanied
by a certificate of supervision in a prescribed form given
in Chapter- VI by the licensed architect, engineer, groups
as the case may be.
(E) A certificate to the effect that the maximum requirement of
power in the building/ project is being intimated to A.S.E.B. in
advance.
58.12 For the hazardous and industrial building the Authority will ask for
NOC from the State Pollution Control Board.
58.13 All other regulations not specifically mentioned here will be
applicable as per the provision of Zoning Regulations.
58.14 The Authority may ask for any other information considering special
nature of building and location of the plot.
58.15 Engineers Group, Structural Engineers, Geo-Technical Engineers/
Consultants, Supervisors referred to above shall be licensed/ enrolled by the
Authority as competent to do various works as specified in this rules and
modifications made from time to time, detail of which is given in annexure –
II where as Architects registered as an Architect by the Council of Architects
under the Architect Act 1972 are not required to be registered if they provide
satisfactory proof of their valid registration under Architect Act, 1972.
58.16 Penal action for violation of Master plan & its Zoning Regulations
and-Byelaws.
The Authority under provisions of GMDA Act, 1985 shall take penal
action for violation of Master Plan/ Zoning Regulations or Byelaws
which may include stoppage of construction activity, demolition/
NEW REVISED BUILDING BYELAWS FOR GUWAHATI METROPOLITAN AREA-2006
Guwahati Metropolitan Dev. Authority Page No. [46]
alternation and in paying fine and by imposing penalties as given in
Appendix-III.
58.17 The structural design, constructional standard etc. of all multistoreyed
buildings are required to be supervised during construction at three
stages at (1) foundation (2) plinth/ Gr. Floor, (3) upper floor in the
manner described below.
i) The individual /promoter is required to get their construction
checked at above mentioned three stages of construction through
licensed technical firms of Authority before proceeding with
next stage of construction failing which the Authority may
revoke the permission.
ii) The supervision under this clause will be done by the concerned
firm. Necessary certificate is to be submitted duly signed by firm
and applicant in the manner given in Form 1 to 4.
iii) The individual promoter/developer is required to employ technical
personnel of suitable competence for daily supervisions of construction
work.
58.18 The inconsistent provisions of the present Zoning Regulations will
cease to operate within Guwahati Metropolitan Area with effect from
the date on which these modifications are first published and the
Authority can enforce these provisions with immediate effect from a
date to be notified by the Authority.
58.19 Should any dispute arise about the interpretation of any definitions or
provisions of these rules, the decision of the Authority shall be final.
However, aggrieved persons may appeal to the appellate authority
against such decisions and the decisions of the appellate authority shall
be final and binding to all concerned.
58.20 For construction of any public and apartment building of height-
above-12-metre-–
(i) The structural design is required to be done as per IS code of practice
by a
licensed structural engineering consultant and the structural
calculations, designs and drawings and specifications are-certified-by-
this-consultant.
(ii) The soil testing report on which the design is based is required to be
obtained from a licensed Geo-technical consultant.
(iii) For public buildings and apartments, permission for construction shall
not
be granted unless :-
(a) The builder submits detailed calculations of structural design
along with copies of structural drawings and specifications
certified by the structural engineering consultant. (detail in
Chapter-VI)
(b) Provision is made for appropriate treatment of septic tank
effluent, sullage water, garbage and drainage of waste water.
Note: - (a) The Authority may go for proof checking of structural
design through a structural designs review panel to be
setup by the Authority. Proof checking will only be
done on the basis of recommendations of the
Committee approving the proposal based on each case
as specified in Chapter-VI.
NEW REVISED BUILDING BYELAWS FOR GUWAHATI METROPOLITAN AREA-2006
Guwahati Metropolitan Dev. Authority Page No. [47]
(b) Record of construction progress be intimated to the
Authority and stage for recording progress certificate
(format to be given by the Authority) and checking is
given below: - (detail given in Chapter-VI)
(i) Plinth in case of basement before casting of
basement slab
(ii) First storey
(iii) Middle storey incase of multistoreyed
building
(iv) Last storey
The progress certificate is to be signed by
owner/developer/builder and R.T.P.
Note: Procedure to be followed for ensuring structural safety of the building
will be governed by provisions given in detail in Chapter-VI of these rules.
(iv) Availability of source of water supply is to be ensured by the
builder before granting permission for construction of a multi-
storied building. Report of test boring and other study to
ascertain the availability of ground water may be called for if
the source of water is ground water.
(v) Electrical installation: Proper location and space for
electrical facilities as per Indian Electricity Rules is to be
provided in all buildings above 15 m height and all works
of lift installation must comply with requirement of B.I.S.
codes of practice and relevant provisions of Indian
Electricity Rules and should be approved by the Chief
Electrical Officer of Govt. of Assam.
(vi) Improvement of drains upto the nearest outlet point is to
be made as directed by the Authority. Additional 25% of
the cost of improvement at PWD rate be imposed as
penalty if such improvement is not done as directed by
the Authority.
58.21 Should at any time the Authority decide that certain provision of
these rules require change or suspension in certain areas for a
comprehensive development of the area, the same can be made
by the Authority with prior approval of the Govt.
58.22 Provisions of National Building Code 2005 will apply in case of
those provisions which are not specified in this Byelaws.
NEW REVISED BUILDING BYELAWS FOR GUWAHATI METROPOLITAN AREA-2006
Guwahati Metropolitan Dev. Authority Page No. [48]
Chapter-V
MISCELLANEOUS
Previous and next
Questions people ask
Is rule 56 of GUWAHATI BUILDING BYELAWS still in force?
No repeal of GUWAHATI BUILDING BYELAWS is recorded.