Rule 44, GUWAHATI BUILDING BYELAWS: Water supply
GUWAHATI BUILDING BYELAWS - Rule 44
Text of rule 44
Water supply
44. Water supply:- Every living unit shall have available supply of safe water
obtained from any of the following sources -
(a) Public or municipal water if available.
(b) A drilled, driven or dug well or tube well.
45. Basement- The construction of the basement shall be allowed by the Authority
in accordance with the landuse and other provisions specified under the
Development
Control Rules and this Byelaws.
NEW REVISED BUILDING BYELAWS FOR GUWAHATI METROPOLITAN AREA-2006
Guwahati Metropolitan Dev. Authority Page No. [30]
Basement can be constructed up to minimum prescribed setbacks line
and beyond prescribed building lines.
Basement shall not be permitted in low lying areas and areas without
adequate drainage facilities to ensure drainage from the basement.
Basement may be put to only the following uses-
(a) Storage of household or other goods of ordinary non combustible
material;
(b) Strong rooms, bank cellars etc.
(c) Air conditioning equipment and other machines used for services and
utilities of building subject to satisfaction of the Authority.
(d) Parking spaces.
(e) Air conditioned shopping which will then be counted in FAR.
46. The basement shall have the following requirements:
(a) Every basement shall be in every part at least 2.4 m in height from the
floor to the underside of the roof slab or ceiling;
(b) Adequate ventilation shall be provided for the basement. The standard of
ventilation shall be the same as required by the particular occupancy to
Rule. Any deficiency may be met by providing adequate mechanical
ventilation in the form of blowers, exhaust fans, air conditioning system
etc.
(c) The minimum height of the ceiling of any basement shall be 1 m above
the average surrounding ground level.
(d) Adequate arrangements shall be made so that surface drainage do not
enter the basement.
(e) The walls and floor of the basement shall be watertight and be so
designed that the effect of the surrounding soil and moisture, if any, are
taken into account in design and adequate dampproofing treatment is
given.
(f) The access to the basement shall be separate from the main and alternate
staircase providing access and exit from higher floors, where the
staircase is continuous. In case of building served by more than one
staircase the same shall be of enclosed type serving as a fire separation
from the basement floor and higher floors. Open ramps shall be
permitted if they are constructed within the building line subject to the
provision of (d) above.
(g) If such ramps are provided in basement parking floor the gradient of it
should be minimum 1:5 and the height of 2.7 m is to be maintained at
the entrance also.