Rule 37, GUWAHATI BUILDING BYELAWS: (A) Maximum height of the building and additional requirement
GUWAHATI BUILDING BYELAWS - Rule 37
Text of rule 37
(A) Maximum height of the building and additional requirement
37. (A) Maximum height of the building and additional requirement: -
Buildings shall not exceed 3 storey or a height of 12 m. without the
following additional provisions for open space all around the building
except in cases where otherwise specified.
(i) The side and rear setback shall be increased by 0.3 mtrs for every
1.5 mtrs additional height of the building in addition to the
NEW REVISED BUILDING BYELAWS FOR GUWAHATI METROPOLITAN AREA-2006
Guwahati Metropolitan Dev. Authority Page No. [28]
setback already prescribed in this rule subject to maximum of 4.5
mtrs side setback and 6.0 mtrs rear setback.
(ii) Building shall not exceed 1.5 times of the width of the road plus
front open space.
(iii) Residential building should not be cut by 45 degree angle line
drawn from the opposite edge of the road. However building
upto two storey is exempted of it.
(a) For the purpose of height calculation width of the road shall be
taken as existing road width.
(b) Lift machine room, staircase, parapet height shall not be included
in the height of the building.
(c) For a building constructed on stilt with provisions of ground
level parking floor or semi-basement parking floor, the height of
the building will be calculated by omitting the the height of the
parking floor upto a maximum of 2.7 mtr for the purpose of
building height subject to provision of exclusive parking in the
ground floor with special earthquake resistance measure.
(d) Building above the height of 15.8 mtrs shall require necessary
clearance from State Fire Service.
(e) For a building with a height 12 mtrs or above 4 floors including
the ground floor, at least one lift shall be made available.
(f) For building in the vicinity of aerodromes, the maximum height
of such building shall be subject to conformity with the height
limitations prescribed by the Civil Aviation authorities from time
to time and to this effect a No Objection Certificate issued by
that authority shall be submitted by the applicant along with
plans to the sanctioning Authority.
(g) Height exception: - The following appurtenant structure shall not
be included in the height of building.
(i) Roof tanks and their supports not exceeding 1.5 mtr in
height.
(ii) Ventilating, air conditioning and lift rooms and similar
service equipments, stair covered with roof upto 3.0 mtr
in height, chimney and architectural features not
exceeding 1.5 mtrs in height.
(iii) Rooftop Assam Type pitched rain harvesting structure
covering up to 50% of the roof area. The height of such
structure is to be restricted to 2.1 m. subject to maximum
permissible FAR if the space is put to specific use.
(h) Maximum height of parking floor shall be 2.7 m measured upto the
soffit level.