Rule 34, GUWAHATI BUILDING BYELAWS: Post, Postplate, Truss etc

GUWAHATI BUILDING BYELAWS - Rule 34

Text of rule 34

Post, Postplate, Truss etc.

34. Post, Postplate, Truss etc.: - (a) In the case of wooden posts these should be firmly fixed with the post pillar by means of two or more flat iron straps bolted together. NEW REVISED BUILDING BYELAWS FOR GUWAHATI METROPOLITAN AREA-2006  Guwahati Metropolitan Dev. Authority  Page No. [27]  (b) The flat iron strap should at least be 0.6 m. inserted into the post pillar and at least 0.15 m. above for bolting with the post. (c) The wooden posts should be made of well seasoned sal wood or any other first class hard local wood. The size of such posts should not be in any case less than 100 mm x 100 mm or in the case of circular post diameter should not be less than 150 mm. (d) Only on special ground/case found fit by the Authority on condition given to him thatched roof house will be allowed within the Master Plan area.