Rule 31, GUWAHATI BUILDING BYELAWS: Ventilation of rooms
GUWAHATI BUILDING BYELAWS - Rule 31
Text of rule 31
Ventilation of rooms
31. Ventilation of rooms: -
(a) Every room in a residential building which is intended to be used as an
inhabited room shall be provided for the purpose of light and ventilation
with windows, clear storey windows, doors and apertures having a total
area of not less than 1/6 at the floor area of the room.
(b) Stores, backroom and the like:- These will have at least half of the
ventilation required for living rooms. When such ventilation by
apertures in walls is not possible or advisable, at least there shall be
ventilation by means of a flow or chimney.
(c) Laundry and recreation room:
Laundry and recreation rooms located above the basement shall be
lighted by window located in exterior walls having openings of not less
than 10 p.c. of the floor area.
(d) Basement and cellars: -
Basement and cellars and all rooms located therein, except storage
rooms, shall be lighted and ventilation area of not less than 5 p.c. of the
floor area.
(e) Kitchen:- Every kitchen shall be ventilated according to the standards of
habitable rooms.