Form 15, GUWAHATI BUILDING BYELAWS: FORM NO. 15
GUWAHATI BUILDING BYELAWS - Form 15
Text of form 15
FORM NO. 15
FORM NO. 15
MODEL PROFORMA FOR TECHNICAL AUDIT REPORT
1. Design
COMMENTS
1.1 Design / Drawings available Y/N
Design Category
Type Design?
Specific design?
Y/N
Design to be collected to
refer to Design Consultant /
H.O.
Drawings prepared / checked by competent Authority ? Y/N
Design Drawings / details
Structural detailed included
Earthquake / cyclone resistant features included?
Y/N
Design verified / vetted by Dept. / Govt. approved agency /
competent authority?
Y/N
Design changes approved by Dept. / Govt. approved agency /
competent authority?
Y/N
2. Foundation
2.1 Foundation used Existing/New
2.2.1 If existing foundation used
2.2.1 Depth of foundation below ground : <50cm/50-70/>70cm
2.2.2 Type of foundation : Isolated/Combined/Raft/Piled etc.
2.2.3 Thickness of masonry (above ground) :
2.2.4 Mortar used and Mix of cement mortar : Cement-Sand/Lime and 1:4/1:6/Leaner
2.2.5 Grade of concrete (M20) : Y/N
2.2.6 Height up to Plinth : ________________ cm
2.2.7 If stone masonry
2.2.7.1 Through Stones : Yes/No, if Yes Adequate / Inadequate
2.2.7.2 Corner Stones : Yes/No, if Yes Adequate/Inadequate
2.3 If new foundation used
2.3.1 Depth of foundation below ground : _____ <50/50-70/>70cm
2.3.2 Type of foundation : Isolated/Combined/Raft/Piled etc.
2.3.3 Thickness of Masonry above plinth : ____________________________
2.3.4 Mortar used and Mix of cement mortar (1:4): Cement – sand/lime/mud and Y/N
2.3.5 Grade of concrete (M20) :Y/N
2.3.6 Height up to Plinth : <60/>60cm
2.3.7 If stone masonry
2.3.7.1 Through Stones : Yes/No, if Yes Adequate/Inadequate
2.3.7.2 Corner Stones : Yes/No, if Yes Adequate/Inadequate
Vertical reinforcement in foundation : Yes/No
NEW REVISED BUILDING BYELAWS FOR GUWAHATI METROPOLITAN AREA-2006
Guwahati Metropolitan Dev. Authority Page No. [90]
3 Walling
3.1 Type of masonry : Brick/PCC Blocks/ Stone
3.2 Mortar used : Cement – Sand/Lime
3.3 Mix of cement mortar : 1:4/1:6/Leaner
3.4 Thickness of wall : >23cm/23cm/23cm
3.5 Mixing of mortar : OK/Not OK
3.6 Joint Property filled : OK/NOT OK
3.7 Wetting of bricks : Good/ Medium/ Poor
3.8 If stone masonry
3.8.1 Through Stones : Yes/No
3.8.2 Corner Stones : Yes/No
3.9 Overall workmanship : Good / Medium / Poor
4 Roofing
4.1 Type of roof : Flat/Sloping
4.2 If sloped : A.C. sheet/ G.I. sheet /Morbid tiles
4.3 Purlins : Angle-Iron / Timber / NA
4.4 Truss type : _______________________
4.5 Anchorage with wall : Adequate/ Inadequate/ NA
5 Materials
5.1 Cement
5.1.1 Source : Authorized Dealer/ Market
5.1.2 Type of cement : OPC/PPC/PSC
5.1.3 If OPC : Grade (33/ 43/ 53)
5.2 Sand
5.2.1 Type of sand : River sand / Stone dust
5.2.2 Presence of deleterious materials : Mild / Moderate/ High
5.3 Coarse Aggregates
5.3.1 Type coarse Aggregates : Gravel/ Crushed Stone
5.3.2 Presence of deleterious material : Mild/ Moderate / High
5.4 P.C.C. Blocks (Applicable for onsite production)
5.4.1 Type of P.C.C. Blocks : Solid blocks/Hollow blocks
5.4.2 Ratio of concrete in blocks : ______________________
5.4.3 Interlocking feature : Yes/No
5.4.4 Course aggregates used : Natural/ Crushed stone
5.5 Bricks Blocks, Stone etc.
5.5.1 Strength (field assessment) : Low/Medium/High
5.5.2 Dimensional accuracy : Yes/No
5.6 Concrete
5.6.1. Mix of concrete : M20/Design Mix
5.6.2 Batching : Weigh batching/Volume batching
5.6.3 Compaction : Vibrators/Thappies and rods
5.6.4 Workability : Low / Medium / High
NEW REVISED BUILDING BYELAWS FOR GUWAHATI METROPOLITAN AREA-2006
Guwahati Metropolitan Dev. Authority Page No. [91]
5.6.5 Availability of water : Optimum/Sufficient / Insufficient
5.6.6 Curing : Satisfactory/Unsatisfactory.
5.7 Reinforcing Steel
5.7.1 Type of Steel : Plain mild steel/HYSD bars
5.7.2 Source : Authorised Dealer/Market
5.7.3 Whether IS marked : Yes/No
5.7.4 Conditions of bars : Clean/Corroded
5.7.5 Fixing of reinforcement
as per drawing : Yes/No
5.7.6 Suitable cover : Yes/No
5.7.7 Spacing of bars : Regular/Irregular
5.7.8 Overlaps as per specifications : Yes/ No
5.8 Form Work
5.8.1 Type of Form Work : Timber / Plyboard/ Steel
5.8.2 Use of mould oil : Yes/No
5.8.3 Leakage of cement slurry : Observed/Not observed
5.9 Source
5.9.1 Cement
5.9.2 Sand
5.9.3 Coarse Agg.
5.9.4 Bricks
5.9.5 PCC blocks.
6 Seismic resistance features
6.1 Masonry Structures
6.1.1 Provision of bands at Provided Adequate
6.1.1.1 Plinth level Yes/No Yes/No
6.1.1.2 Sill level Yes/No Yes/No
6.1.1.3 Lintel level Yes/No Yes/No
6.1.1.4 Roof level (if applicable) Yes/No Yes/No
6.1.2 If sloped Roof, whether seismic bands are provide at
6.1.2.1 Gable wall top Yes/No Yes/No
6.1.2.2 Eaves level Yes/No Yes/No
6.1.3 Provision of vertical steel in masonry at Provided Adequate
6.1.3.1 Each corner Yes/No Yes/No
6.1.3.2 Each T-junction Yes/No Yes/No
6.1.3.3 Each door joint Yes/No Yes/No
6.1.3.4 Around each window Yes/No Yes/No
6.1.4 Openings
6.1.4.1 Total width of openings : <50%/50*-60%/>60%
(*-42% for double storey)
6.1.4.2 Clearance from corner : OK/Not OK
6.1.4.3 Pier width between two openings : OK/Not OK
NEW REVISED BUILDING BYELAWS FOR GUWAHATI METROPOLITAN AREA-2006
Guwahati Metropolitan Dev. Authority Page No. [92]
6.2 Framed Structures
6.2.1 Ductile detailing
6.2.1.1 Spacing of stirrup : OK/Not OK
6.2.1.2 Sizes of members : OK/Not OK
6.2.1.3 End anchorage : OK/Not OK
6.2.1.4 Lapping (length, location etc.) : OK/Not OK
6.2.1.5 Angle of stirrup hook : 90 / 135 degrees
6.3 Any testing carried out by Owner/Engg. Supervisor on
Testing done Testing results
6.3.1 Water Yes/No OK/Not OK
6.3.2 Cement Yes/No OK/Not OK
6.3.3 Bricks/PCC blocks/Stones Yes/No OK/Not OK
6.3.4 Aggregate Yes/No OK/Not OK
6.3.5 Mortar Yes/No OK/Not OK
6.3.6 Concrete Yes/No OK/Not OK
6.3.7 Reinforcement Yes/No OK/Not OK
NEW REVISED BUILDING BYELAWS FOR GUWAHATI METROPOLITAN AREA-2006
Guwahati Metropolitan Dev. Authority Page No. [93]
Previous and next