Form 6, GUWAHATI BUILDING BYELAWS: FORM NO. 6

GUWAHATI BUILDING BYELAWS - Form 6

Text of form 6

FORM NO. 6

FORM NO. 6 STRUCTURAL DESIGN BASIS REPORT 1. This report to accompany the application for Building Development Permission. 2. In case information on items 3, 10, 17, 18 and 19 can not be given at this time, it should be submitted at least one week before commencement of construction. Part 1: General Data Sl No Description Information Notes 1 Address of the building • Name of the building • Plot number • Subplot number • TPS scheme a. Name b. Number • Locality/Township • District 2 Name of owner 3 Name of Builder on record 4 Name of Architect/Engineer on record 5 Name of Structural engineer on record 6 Use of the building 7 Number of storeys above ground level (including storeys to be added later, if any) 8 Number of basements below ground Level 9 Type of structure • Load bearing walls • R.C.C frame • R.C.C frame and Shear walls • Steel frame 10 Soil data • Type of soil • Design safe bearing capacity IS: 1893 Cl. 6.3.5.2 IS: 1904 11 Dead loads (unit weight adopted) • Earth • Water • Brick masonry • Plain cement concrete • Reinforced cement concrete • Floor finish • Other fill materials • Piazza floor fill and landscape IS: 875 Part 1 12 Imposed (live) loads • Piazza floor accessible to Fire Tender • Piazza Floor not accessible to Fire Tender IS: 875 Part 2 NEW REVISED BUILDING BYELAWS FOR GUWAHATI METROPOLITAN AREA-2006  Guwahati Metropolitan Dev. Authority  Page No. [77]  . h�Floor loads . h�Roof loads 13 Cyclone / Wind • Speed • Design pressure intensity IS: 875 Part 3 14 Seismic zone IS:1893 2002 15 Importance factor IS:1893 (2002) Table 6 16 Seismic zone factor(Z) IS:1893 Table 2 17 Response reduction factor IS: 1893 Table-7 18 Fundamental natural period - approximate IS: 1893 Cl. 7.6 19 Design horizontal acceleration spectrum value (Ah) IS: 1893 Cl. 6.4.2 20 Expansion / Separation Joints Part 2: Load bearing masonry buildings Sl No Description Information Notes 1 Building category IS:4326 Cl. 7 read with IS: 1893 Bld/Zone II III IV V Ord. B C D E Important C D E E 2 Basement Provided 3 Number of floors including Ground Floor (all floors including stepped floors in hill slopes) 4 Type of wall masonry 5 Type and mix of Mortar IS:4326 Cl. 8.1.2 6 Re: size and position of openings (See note No.1) • Minimum distance (b5) • Ratio (b1+b2+b3)/l1 or (b6+b7)/l2 • Minimum pier width between consequent opening (b4) • Vertical distance (h3) • Ratio of wall height to thickness4 • Ratio of wall length between cross wall to thickness IS:4326 Table 4, Fig.7 7 Horizontal seismic band • at plinth level • at window sill level • at lintel level • at ceiling level • at eave level of sloping roof • at top of gable walls • at top of ridge walls P IP NA (see note no.2) IS:4326 Cl. 8.4.6 IS:4326 Cl. 8.3 IS:4326 Cl. 8.4.2 IS:4326 Cl. 8.4.3 IS:4326 Cl. 8.4.3 IS:4326 Cl. 8.4.4 8 Vertical reinforcing bar • at corners and T junction of walls • at jambs of doors and window openings IS:4326 Cl. 8.4.8 IS:4326 Cl. 8.4.9 9 Integration of prefab roofing/flooring elements through IS:4326 Cl. 9.1.4 NEW REVISED BUILDING BYELAWS FOR GUWAHATI METROPOLITAN AREA-2006  Guwahati Metropolitan Dev. Authority  Page No. [78]  reinforced concrete screed 10 Horizontal bracings in pitched truss • in horizontal plane at the level of ties • in the slopes of pitched roofs Part 3 : Reinforced concrete framed buildings Sl No Description Information Notes 1 Type of Building i�Regular frames i�Regular frames with Shear walls i�Irregular frames i�Irregular frames with shear walls i�Soft storey IS: 1893 Cl. 7.1 2 Number of basements 3 Number of floors including ground floor 4 Horizontal floor system i�Beams and slabs i�Waffles i�Ribbed Floor i�Flat slab with drops i�Flat plate without drops 5 Soil data i�Type of soil iRecommended type of foundation - Independent footings - Raft - Piles iRecommended bearing capacity of soil iRecommended, type, length, diameter and load capacity of piles iDepth of water table iChemical analysis of ground water iChemical analysis of soil IS: 1498 6 Foundations iDepth below ground level iType • Independent • Interconnected • Raft • Piles 7 System of interconnecting foundations i�Plinth beams i�Foundation beams IS: 1893 Cl. 7.12.1 8 Grades of concrete used in different parts of building 9 Method of analysis used 10 Computer software used IS: 1893 Cl. 7.9 11 Torsion included 12 Base shear a. Based on approximate fundamental period b. Based on dynamic analysis IS: 1893 Cl. 7.5.3 NEW REVISED BUILDING BYELAWS FOR GUWAHATI METROPOLITAN AREA-2006  Guwahati Metropolitan Dev. Authority  Page No. [79]  c. Ratio of a/b 13 Distribution of seismic forces along the height of the building IS:1893 Cl. 7.7 (provide sketch) 14 The column of soft ground storey specially designed IS:1893 Cl. 7.10 15 Clear minimum cover provided in • Footing • Column • Beams • Slabs • Walls IS: 456 Cl. 26.4 16 Ductile detailing of RC frame • Type of reinforcement used • Minimum dimension of beams • Minimum dimension of columns • Minimum percentage of reinforcement of beams at any cross section • Maximum percentage of reinforcement at any section of beam • Spacing of transverse reinforcement in 2-d length of beams near the ends • Ratio of capacity of beams in shear to capacity of beams in flexure • Maximum percentage of reinforcement in column • Confining stirrups near ends of columns and in beam-column joints a. Diameter b. Spacing • Ratio of shear capacity of columns to maximum seismic shear in the storey IS: 456 Cl. 5.6 IS:13920 Cl. 6.1 IS:13920Cl. 7.1.2 IS: 456 Cl. 26.5.1.1(a) IS:13920 Cl. 6.2.1 IS: 456 Cl. 26.5.1.1(b) IS:13920 Cl. 6.2.2 IS: 13920 Cl. 6.3.5 IS: 456 Cl. 26.5.3.1 IS: 13920 Cl. 7.4 General Notes 1. A certificate to the effect that this report will be completed and submitted at least one month before commencement of Construction shall be submitted with the application for Building Development Permission. 2. In addition to the completed report following additional information shall be submitted, at the latest, one month before commencement of Construction. 2.1 Foundations 2.1.1 Incase raft foundation has been adopted indicate K value used for analysis of the raft 2.1.2 Incase pile foundations have been used give full particulars of the piles, type, dia, length, capacity 2.1.3 Incase of high water table indicate system of countering water pressure, and indicate the existing water table, and that assumed to design foundations. 2.2 Idealization for Earthquake analysis 2.2.1 Incase of a composite system of shear walls and rigid frames, give distribution of base shear in the two systems on the basis of analysis, and that used for design of each system. 2.2.2 Indicate the idealization of frames and shear walls adopted in the analysis with the help of sketches. 2.3 Submit framing plans of each floor 2.4 Incase of basements, indicate the system used to contain earth pressures Part 4 : Buildings in Structural Steel 1 Adopted method of Design O Simple O Semi-rigid O Rigid IS: 800; Cl. 3.4.4 IS: 800; Cl. 3.4.5 IS: 800; Cl. 3.4.6 NEW REVISED BUILDING BYELAWS FOR GUWAHATI METROPOLITAN AREA-2006  Guwahati Metropolitan Dev. Authority  Page No. [80]  2 Design based on O Elastic analysis O Plastic analysis IS: 800; Section-9 SP: 6 (6) 3 Floor Construction O Composite O Non-composite O Boarded 4 Roof Construction O Composite O Non-composite O Metal O Any other 5 Horizontal force resisting system adopted O Frames O Braced frames O Frames & shear walls Note: Seismic force As per IS: 1893Would depend on system 6 Slenderness ratios maintained Members defined in Table 3.1, IS: 800 IS: 800; Cl. 3.7 7 Member deflection limited to Beams, Rafters Crane Girders Purlins Top of Columns IS: 800; Cl. 3.13 8 Structural members O Encased in Concrete O Not encased IS: 800; Section-10 9 Proposed material O General weld-able O High strength O Cold formed O Tubular IS: 2062 IS: 8500 IS: 801, 811 IS: 806 10 Minimum metal thickness Specified for corrosion protection O Hot rolled sections O Cold formed sections O Tubes IS: 800, Cl. 3.8 Cl. 3.8.1 to Cl. 3.8.4 Cl. 3.8.5 Cl. 3.8.5 11 Structural connections O Rivets O C T Bolts O S H F G Bolts O Black Bolts O Welding- Field Shop (Specify welding type proposed) O Composite IS: 800; Section-8 IS: 1929,2155,1149 IS: 6639, 1367 IS: 3757, 4000 IS: 1363, 1367 IS: 816, 814, 1395, 7280, 3613, 6419 6560, 813, 9595 Minimum Fire rating Proposed, with method O Rating ---------- hours O Method proposed- - In tumescent Painting - Spraying - Quilting - Fire retardant boarding IS: 1641, 1642, 1643 NEW REVISED BUILDING BYELAWS FOR GUWAHATI METROPOLITAN AREA-2006  Guwahati Metropolitan Dev. Authority  Page No. [81] 

Previous and next

All provisions of GUWAHATI BUILDING BYELAWS

Questions people ask

Is form 6 of GUWAHATI BUILDING BYELAWS still in force?

No repeal of GUWAHATI BUILDING BYELAWS is recorded.