Regulation 11, Development Control Regulations: Transitory provisions
Development Control Regulations - Regulation 11
Text of regulation 11
Transitory provisions
11. Transitory provisions.—All applications for development including multi-storeyed building, pending prior to the issue of
these development control regulations shall be disposed of in accordance with the planning parameters and rules prevailing before
the issue of these regulations.
Description Minimum width Remarks
Passage:
The length of existing or proposed passage is
less than 50 metres
3.00 metres Passage may be private
June 16, 2010] TAMIL NADU GOVERNMENT GAZETTE 327
Schedule – I
Open Space Reservation
(1) The open space reservation of land for community recreational purposes such as park / play ground shall be as given
below at ground level in a shape and location abutting a public road:
(2) The site so reserved shall be exclusive of the back spaces and spacing between blocks, and shall be free from any
construction / structure.
(3) Existing development is defined as one where the extent of ground area covered by structures already existing (prior to
application for planning permission) is 25% and above of the total site area.
(4) Open Space Reservation (OSR) should be earmarked only on the area abutting public road. Only under unavoidable
circumstances these OSR, which may be permitted within the site abutting internal circulation road provided that road also to be
handed over to local body.
(5) In the specific cases where a clearly demonstrable hardship is caused, the Empowered committee may relax various
conditions on the OSR mentioned above.
(6) Payment of cost in lieu of OSR is generally not permissible, however for lesser extent this may be considered by
Empowered Committee on case to case basis.
(7) OSR should be earmarked at one place only. In case of major development, Empowered Committee may consider splitting
of OSR at more than one places on case to case basis.
Schedule - II
Parking Standards
Extent of site Reservation
(a) For 2500 square metre Nil
(b) Above 2500 square metre 10% of the area subject to a minimum dimension of 10
metres.
Sl.
No. Building use No. of Parking Spaces
(1) (2) (3)
1. Residential
For building with dwelling unit or units
of floor area exceeding 75 square
metres each
One car space for 75 square metres of floor area or part thereof
excluding the first 75 square metres in other words
Dwelling area No. of cars.
Upto 150 square metres 1 car space
above 150 square metres but below 225
square metres
2 car space
above 225 square metres but below 300
square metres
3 car space
Two wheeler parking - One two wheeler parking space for every
dwelling unit with floor area of 40-75 square metres. The
dimension of two wheeler parking lot shall be minimum1.5
metres x 2 metres with a driveway of minimum 1.5 metres.
Note :- In such cases where the number of car parking space
required does not exceed 3 in number, separate driveway need
not be insisted.
2. Commercial (i) Floor area upto 50 square metres – Nil
(a) Shop and
(b) Shopping centre below 100
square metre - 1 car space.
(ii) Floor area above 50 square metre but
(iii) For every additional 50 square metres or part thereof
exceeding 100 square metres - 1 car space.
(c) Office and firm (including public
and Semi public offices)
One car space for every 100 square metres of floor area or part
thereof.
(d) R t t O f 100 t f fl t
328 TAMIL NADU GOVERNMENT GAZETTE [Part II—Sec. 2
p )
(d) Restaurants One car space for every 100 square metres of floor area or part
thereof.
(e) Hotels and Lodges 1. In starred and major hotels with more than 50 rooms one
space for every 4 guest rooms
2. In unstarred and other hotels - One space for every10 guest
rooms.
. (f) Assembly Halls, Cinema and
Public Halls including
Community Centres.
One space for every 20 square metres of auditorium area
(g) Kalyanamandapams One space for every 20 square metres of marriage hall area.
3. Warehouse and Wholesale stores One lorry space for every 500 square metres of plot area or less.
4. Educational Institutions 1. Floor area less than100
square metres
Nil
2. Floor area above 100 square
metres but less than 1000
square metres
One car space for every
200 square metres of floor
area or part thereof.
3. For every additional
100 square metres of Floor Area
or part thereof over 1000 square
metres.
One car space
Note : Atleast 25% of the total parking space shall be provided in
the part of the site abutting the road for parking / stopping of
vehicles.
5. Hospitals and Nursing Home One space for every 15 beds of part thereof. One extra area for
every 100 square metres of non-bed space in the Hospitals and
Nursing Homes.
6. Industries i) Floor Area upto 100 square
metres
Nil
ii) Floor Area upto 500 square
metres
One lorry space
iii) Floor area exceeding 500
square metres
One lorry space for every 500
square metres of total floor
every 500 square metres of
total floor area or part thereof.
7. Other uses
Communications Centre etc.)
As may be specified by the Authority.
PART II PART – II
Dimension : The dimension of parking stall shall be 5.0m x 2.5m with a
minimum which width of driveway of 3.5m for one way
movement and 7.2m width for two way movement. In the case of
ware house and godowns and industries the dimension of
parking stall shall be 10m x 3.75m with a minimum width of
driveway of 3.75m. The number of car spaces required will be
calculated on 75% of the total floor area of the building.
2. i) Radius Minimum inside radius of lane 4.5 metres
ii) Gradient 1. Preferred gradient 4% (1 in 25)
2. Absolute maximum gradient 5% (1 in 20)
3. Head Room In those parts of a building (above or below ground floor level)
used or intended to be used for the parking of wheeled vehicles,
the minimum clear height to such part of the building shall be not
less than 2.4 metres. For lorry parking the minimum head room
shall be 3.5 metres.
4. Conditions : 1. The area of each stall shall be flat and free from kerbs
and other encumbrances.
2. The angled parking, where a stall is adjacent to a large
element such as a wall, minimum stall width shall be 2.7
metres for parallel parking, where cars cannot be parked
by reversing, minimum stall length shall be 7.2 metres.
T f S ll i Mi i Ai l
June 16, 2010] TAMIL NADU GOVERNMENT GAZETTE 329
Schedule - III
Structures permissible in the minimum prescribed Front setback, side setback and rear setback
(1) Unless or otherwise specifically provided for elsewhere in these regulations, no structure shall be constructed within the
minimum prescribed set back spaces except the following:-
(a) In cases of non-multi-storyed buildings (including ordinary buildings)-
A. Unsupported sunshade, wardrobes, balconies, and other projections from the main walls, stated below so long as such
structures do not fall within minimum prescribed set-back spaces more than what is prescribed below:-
by e e s g, u sta e gt s a be et es
3. Type of
Parking
Stall size Minimum Aisle
width
(i) Parallel
parking
2.5 x 6.0m Rectangular 3.5metre
30 degree 2.5 x 5.0m Rectangular 3.5metre
45 degree 2.5 x 5.0m Rectangular 3.5 metre
60 degree 2.5 x 5.0m Rectangular 3.5 metre
90 degree 2.5 x 5.0m Rectangular 6.0 metre
4. The width of aisles and ramps shall be free from
kerbs and other encumbrances.
5. Adequate blending of ramp grades at floor levels shall
be provided. This can be satisfactorily achieved by
the provision of straight slope 3.0 metres to 3.6
metres long at half the grade of the ramps.
6. The surface of long spiral ramps shall be super
elevated to facilitate movement of vehicles or other
adopted.
7. The slope of a curved ramp shall be that of the
centerline of its path.
PART – III
1. No. of storeys permissible
2. Gradient and ramps - 1 in 10 generally
- 1 in 8 minimum
3. Clear height between floors - 2.10 metres minimum
4. Parking stall dimension - 2.5 metres x 5.0 metres
5. Inside radius of curve - 7 metres minimum
6. Width of traffic lane, ramps and
entrance
- 7.5 metres minimum
7. Gradient of slopping floors - Not steeper than 1 in 20
8. Loading standards - 400 kg / sq.m. maximum
Multi Level Parking :
9. Ramps if two way, shall be
separated.
(i) Sun-shades 0.60 metres
(ii) Non continuous wardrobes or built-in cub boards above ground floor 0.60 metres
(iii) open non-continuous balconies (above ground floor) 1.20 metres
(iv) open service verandah to kitchen (above ground floor) 1.20 metres
(v) Architectural projections above ground floor 1.00 metres
(vi) Staircase open landing projections (not affecting driveway) 1.00 metres
(vii) Cantilevered portico so long as it does not fall within 1.5 metre from the street alignment or boundary
of the site whichever is closer.
330 TAMIL NADU GOVERNMENT GAZETTE [Part II—Sec. 2
The items (iii) to (vi) above shall be permitted in the setback spaces provided a minimum clearance of 0.5 metres for an
ordinary building and 1.50 metres for a special building/ group development and for any other non-multi-storeyed building from the
property boundary or street alignment whichever closer is made available;
Provided further that if non-continuous projecting structures stated above in the set backs exceed 50% of the side/length
of the building, then they shall be taken as forming part of the main building, and shall not be allowed in the minimum prescribed
setback spaces.
B. Motor room of area not exceeding 2 square metre each and height not exceeding 1.8 metres, without affecting parking and
driveway requirements.
(b) In case of ordinary buildings,
Open single or spiral staircase or open double flight staircase so long as such structure do not fall within 0.50 metre from
the side boundary or 1 metre from the rear or front boundary of the site or street alignment.
In case of Residential buildings in the rear set back, structures like lavatory, lumber room, garbage etc. not intended for
human habitation and servant quarters are permissible provided it does not occupy more than one third of the plot width, 6 metres
from rear boundary and 4 metres in height from ground level.
(c) A compound wall of height not exceeding 2.0 metres.
(d) Watchman booth not exceeding 2.5 metres x 2.5 metres in size at each gate and height not exceeding 3 metres
(e) Gate pillars without or with arches with a minimum headroom clearance of 5.50 metres atleast to a width of 3.5 metres
(f) Meter rooms for meter boxes/ electrical panels along the boundary wall or external walls of the building with the
projections not exceeding 0.60 metre from the abutting walls and the open transformer without affecting parking and drive way,
subject to the safety measures stipulated by Tamil Nadu Electricity Board.
Explanations.-(1) Any wardrobe or staircase projection stated above is countable for coverage and FSI computation.
(2) In order to minimise traffic conflicts on to the abutting roads, the number of vehicular entry/exits to site shall be kept
minimum and it shall not exceed 2 numbers (i.e. one entry / one exit); Provided that an additional gate for every 50 metres frontage
may be allowed in large sites if the frontage exceeds 50 metres.
Schedule - IV
Special regulations for physically disabled shall be adhered to as follows:-
In order to provide barrier free environment in the buildings and premises used by public the following shall be provided for
persons with disabilities. (It does not apply to residential developments)
(1) Site planning:
Every building should have atleast one access to main entrance/exit to the disabled which shall be indicated by proper signage.
This entrance shall be approached through a ramp together with stepped entry. The ramp should have a landing in front of the
doorway.
(2) Parking:
(i) Surface parking for atleast two car spaces shall be provided near entrance for the physically handicapped persons with
maximum travel distance of 30 metres from building entrance.
(ii) The width of parking bay shall be minimum 3.6 metres.
(iii) The information stating that the space is reserved for wheel chair users shall be conspicuously displayed.
(3) Building requirements:
(i) For approach to the plinth level, and in other levels where ramps with gradients are necessary or desired they shall
conform to the following requirements:-
(a) Ramps slope shall not be steeper than 1 in 12;
(b) Its length shall not exceed 9 metres between landings and its width shall be minimum 1.5 metres with handrails on
either side;
June 16, 2010] TAMIL NADU GOVERNMENT GAZETTE 331
(c) Its surface shall be non slippery; and
(d) Minimum size of landing shall be 1 metre x 2 metres
(ii) Among the lifts provided within the premises atleast one lift shall have the facility to accommodate the wheel chair size
80cm x 150cm.
(iii) The doors and doorways shall be provided with adequate width for free movement of the disabled persons and it shall not
be less than 90cm.
(iv) Stairs shall have the handrail facilities as prescribed in the National Building Code.
(v) Minimum one special water closet in a set of toilet shall be provided for the use of handicapped as specified in National
Building Code with essential provision of washbasin near the entrance for the handicapped.
Schedule – V
Rain water conservation
Water conservation.-(1) Effective measures shall be taken within each premises for conservation of rainwater and rainwater-
harvesting structures atleast to the following standards shall be provided; the same shall be shown in the plan applied for planning
permission.
(a) Buildings of height upto ground + 1 floor:-
Percolation pits of 30 centimetres diameter and 3 metres depth may be made and filled with broken bricks (or pebbles) for 2.85
metres and the top covered with perforated Reinforced Concrete Cement (R.C.C.) slab. These percolation pits may be made at
intervals of 3 metres centre to center along the plinth boundary. The rain water collected in the open terrace may be collected
through a 150 millimetres Poly Vinyl Chloride Pipe laid on the ground and may be allowed to fall in the percolation pits or into a
open well through a seepage filter of 60cm x 60cm. (filter media broken bricks) provided before the open well which will improve
the ground water level. A dwarf wall of 7.5 centimetres height is built across the entry and exit gates to retain water and allow it
to percolate within.
(b) Special buildings, Group developments, Multi-storyed buildings, Industrial and Institutional buildings:-
There shall be a pebble bed of 1 metre width and 1.5 metres depth all around the building and filled with rounded pebbles of
5 centimetres to 7.5 centimetres size. The concrete paving around the building has to be sloped at about 1 in 20 towards the pebble
bed, so that rain water from the terrace and side open spaces flow over this pavement and spread into the pebble bed around.
Dwarf walls in masonry of 7.5 centimetres, height shall be constructed at the entrance and exit gates to retard rainwater collected
into the compound from draining out to the road.
Or
(c) Any one of the methods shown in the sketches annexed may also be adopted depending on to the conditions and
type of development.
(2) Additional regulations for all buildings:
(a) In the ground floor, floor level of water closets shall be atleast 0.9 metre above the road level to ensure free flow.
(b) All centrally air conditioned buildings shall have their own wastewater reclamation plant and use reclaimed wastewater
for cooling purposes.
(c) A separate sump shall be constructed for storing potable water supplied by the local body, the volume of sump not
exceeding 1,000 litres per dwelling. This sump shall be independent of other tanks, which may be constructed for storing water
obtained from other sources.
332 TAMIL NADU GOVERNMENT GAZETTE [Part II—Sec. 2
Schedule – VI
Spaces excluded from Floor Space Index and coverage computation.
1. The following shall not be counted towards FSI and plot coverage computation:-
(1) Areas covered by stair-case rooms and lift rooms and passages thereto above the top most storey, architectural features,
chimneys, elevated tanks (provided its height below the tank from the floor does not exceed 1.5 metres) and water closet (area
not exceeding 10 square metres).
(2) Staircase and lift rooms and passage thereto in the stilt parking floor.
(3) Lift wells in all the floors.
(4) Area of fire escape staircase and cantilever fire escape passages.
(5) Area of the basement floor/floors used for parking.
(6) Area of the stilt parking floor provided its clear height (between lower floor and the bottom of the roof beam) does not exceed
3.0 metre and it is open on sides, and used for parking.
(7) Area of structures exclusively for, accommodating machineries for water treatment plant and effluent treatment plant
proposed with clearance from Tamil Nadu Pollution Control Board.
(8) Areas covered by service ducts, and garbage shaft.
(9) Area of Balcony/Service verandah to an extent of 5 percent of each dwelling unit area in case of residential buildings and
5 percent of room area in the case of hotels and lodges.
(10) Porches / Canopies / porticos.
(11) Service floor with height not exceeding 1.5 metres.
(12) The following services and incidental structures necessary to the principal use subject to a maximum of 10 percent of the
total floor area:-
(a) Area of one office room not exceeding 15 square metres for co-operative housing society or apartment/ building owners
association in each block.
(b) Servant’s / driver’s bath room and water closet (not exceeding 20 square metres) for each block in cases of special
building, group development and multi-storeyed building at ground floor/ stilt parking floor.
(c) Gymnasium of 150 square metres in floor area.
(d) Area covered by -
(i) Metre room in ground floor or parking floor;
(ii) Air-conditioning plant room in basement or ground floor;
(iii) Electrical room (conforming to Schedule – VIII) in ground floor or stilt parking floor;
(iv) Watchmen or caretaker booth / room in ground floor/ stilt parking floor;
(v) Pump room in ground floor or stilt parking floor;
(vi) Generator room in basement floor or ground floor or stilt floor;
(vii) Lumber room in basement floor or ground floor;
(viii) Air Handling Units in all the floors;
June 16, 2010] TAMIL NADU GOVERNMENT GAZETTE 333
(ix) Electrical / switch gear rooms in all the floors.
(e) Area of one room in ground floor of residential and commercial multi-storeyed building, special buildings, group
developments for separate
Schedule – VII
Additional FSI benefits for Information Technology developments
The development of land and building for the purpose of development of Information Technology park, software and its
associated, computer technology, bio-informatic units shall be certified by the appropriate authority designated by the Government
for the purpose, to avail the concession stated below.
(1) Areas.- The proposed Information Technology development is permissible in the local body area, subject to the provision
of adequate water supply and sewage disposal arrangement to the satisfaction of the authority.
(2) Activities.- Manufacture of hardware, development of software and its associated computer – communication technology
applications, bio-informatic units including offices, conference halls and projection theatres connected therewith, only shall be
permitted. No showrooms, other offices, residential uses and activities of similar nature shall be permitted. Provided that incidental
activities such as staff canteen, staff recreational area, guest accommodation, watchmen quarters and the like not exceeding 10%
of the total floor area shall be permitted. Provided further that within above ceiling of 10%, each of the above incidental activities
should not exceed 5% of the total floor area.
(3) Road width.- The proposed development shall either abut on a public road of not less than 12 metres in case of special
building and 18 metres in case of multi-storeyed building in width or gain access from a passage of not less than 12 metres or
18 metres width which connects to a public road of not less than 12 metres or 18 metres in respective special or multi-storeyed
building.
(4) Site extent.- The site extent shall not be less than 1500 square metres.
(5) Height.- (a) For non-multi-storeyed buildings, it shall in conformity with the requirements prescribed in the regulations.
(b) For multi-storeyed buildings, maximum permissible height shall be 60 metres where the width of the abutting road is
minimum 18 metres, and exceeding 60 metres where the width of abutting road is minimum 30.5 metres, subject to such
conditions as may be necessary.
(6) Floor Space Index.- Maximum Floor Space Index allowable is 1.5 times of the Floor Spaces Index ordinarily permissible.
(7) Car parking standards.- The covered car parking space will be allowed upto ground + 3 floors above ground level and the
same shall not be included in the floor space index/ plot coverage.
(8) Other parameters.- Except for the above said specific provisions, the developments shall conform to these rules in respect
of all other parameters.
Schedule – VIII
Tamil Nadu Electricity Board and Fire and Rescue Service standards
(1) Electrical rooms in Special building, Group development and Multi-storeyed building developments shall conform to the
following:-
(a) Tamil Nadu Electricity Board standards.-
(i) Indoor space required within the premises for installing floor mounted Distribution Transformer and associated
switchgear.
334 TAMIL NADU GOVERNMENT GAZETTE [Part II—Sec. 2
(a) An electrical room for accommodating the transformers and associated switchgears shall be provided at the ground
floor, either within the built up space of the multi-storeyed buildings or outside the building and within the premises of the multi-
storeyed buildings nearer the main entrance of the building. The associated switchgear shall be separated from the transformer
bays by a fire-resisting wall with a fire resistance of not less than 4(four) hours.
(b) The width of the approach road to the above said electrical room shall not be less than 3.0 metres.
(c) The electrical room with RCC roof shall have clear floor area 6m. x 4m. with a vertical clearance of 2.75m.
(d) Three sides of this room shall be covered with brick walls. The fourth side, towards the approach road shall be covered
with M.S. Rolling Grill Shutter of width not less than 3 metre with locking facility.
(e) The electrical room shall be fitted with 2 Nos. exhaust fans in the wall facing the approach road, one on either side
of the shutter.
(f)The electrical room shall have raised cement flooring with cable duct of 450-mm. width and 750 mm. depth, all around
inside the room and close to the exterior wall shutters. The flooring shall slope towards the cable duct. The cable duct shall be
covered with RCC slabs of thickness not less than 75mm (3 inches). The covered slabs shall flush with the cement flooring. The
radius of curvature of the cable ducts at the turnings inside the electrical room shall not be less than one metre.
The open space within the premises for installation.
A clear space of 10m. x 4m. or 5m. x 5m. open to the sky and having an approach road of width not less than 3 metres,
upto the public road shall be provided within the consumer premises, preferably at the main entrance.
(b) Directorate of Fire and Rescue Services standards:
(i) No transformer shall be located below the first basement or above the ground floor
(ii) A sub station or switch station with apparatus having more than 2000 litres oil shall not be allowed in the case of indoor
transformer.
(iii) The indoor transformer should preferably be housed in a fireproof room with walls and doors sufficient fire rating.
The room in the ground floor of the basement housing the transformer shall have a free access to the outside.
There shall be a curb or a dwarf wall around the transformer so that oil spills if any, is contained within the curb. There
shall also be a suitable drain with a ‘flame-arrester’.
If in the basement, the transformers shall be adequately protected against fire by a high velocity water spray or a CO2
flooder of suitable capacity, depending upon the size of the transformer.
The switchgears, if any shall be housed in a separate room with suitable fire resistance walls.
The transformers shall be located only in the periphery of the basement or ground floor, observing suitable clearances.
DCP or CO2 portable fire extinguishers of a minimum capacity of 10kg. shall be kept near the doorway housing the transformer.
All indoor transformers shall be subjected to periodic inspection and shall be replaced in good time so that there is no fire
risk.
The room shall be well ventilated so that the transformer remains cool.
The room shall have emergency and automatic lighting with independent power supply”.
June 16, 2010] TAMIL NADU GOVERNMENT GAZETTE 335
Variation to the Master Plan for Vellore Local Planning Area.
[G.O.Ms. No. 130, Housing and Urban Development (UD4-1), 14th June 2010.]
No. II(2)/HOU/370/2010.—In exercise of powers conferred by sub-section (4) of section 32 of the Tamil Nadu Town and
Country Planning Act, 1971 (Tamil Nadu Act 35 of 1972), the Governor of Tamil Nadu hereby makes the following variation
to the master plan for Vellore Local Planning Area approved under the said Act and published with the
Housing and Urban Development Department Notification No.II(2)/HOU/3322/92 at page 419 of Part II—Section 2 of the
Tamil Nadu Government Gazette, dated the 22nd July 1992.
VARIATION.
In the said master plan, the following Development Control Regulations shall be added at the end, namely:—
DEVELOPMENT CONTROL REGULATIONS
1. Short title.—These regulations may be called Development Control Regulations for Vellore Local Planning Area.
2. Definition. –—“Act” means the Tamil Nadu Town and Country Planning Act, 1971 (Tamil Nadu Act 35 of 1972) as
amended from time to time.
The words and expressions used in these regulations but not expressly defined herein shall have the meaning assigned to them
in the Act and various rules applicable in the said area.
3. Regulation for Special building. - (1) “Special buildings” means -
(a) a residential or commercial buildings with more than two floors; or
(b) a residential building with more than four dwelling units; or
(c) a commercial building exceeding a floor area of 300 square metre:
Provided that any construction in the second floor with prior permission as an addition to an existing ground and first storeyed
authorised ordinary residential building which is three years old shall not be construed as a “Special Building”.
(2) The minimum width of the public road on which the site abuts or gains access shall be 9 metres.
Explanation.—
(i) The qualifying road width for permitting special building shall be available atleast for a reasonable stretch about 250 metres
along the length of the road abutting the site and the stretch from a junction can be straight or a curve or zigzag or combination
of the above. Over this length minor variation in road width at two ends may be considered provided width average outs to 9 metres.
To cite examples:-
(a) If the general road is of width less than 9 metres width, but only widens opposite to or nearer to the site is more than
9 metres, is not acceptable.
(b) If the road is generally of 9 metres width upto a considerable length on one side, but discontinues and narrows into
a road of smaller width on the other side of the site in question and the plot owner is willing to leave enough space
for continuity of 9 metres road in front of his site, this will have to be checked and decided on case-by-case. Reference
in such cases may be made to Empowered Committee.
(c) If the general road width is less than 9 metres and the site owner merely agrees to leave enough space to have 9
metres in front of his site only, this is not acceptable.
(ii) Road width measurements for the above purpose shall be of the road as designed and laid and the existence
of unauthorised encroachments, for which no patta has been given, will not normally affect adversely provided the
shortage in width in the minimum stretch stated above does not exceed 10% of the minimum prescribed width.
336 TAMIL NADU GOVERNMENT GAZETTE [Part II—Sec. 2
However permissibility or otherwise in such specific situations will be decided case-by-case. Reference in such
cases may be made to Empowered Committee.
(3) Planning Parameters.- The extent of the site, plot coverage, FSI, set back etc. for the developments shall be regulated
according to the Table below:—
THE TABLE.
Explanations.—(1) Additional FSI of 20% will be permissible for stilt parking. (2) All those buildings which are otherwise
classified into public and semi-public category qualifying for the definition of ‘commerce’ in section 2(10) and used for ‘commercial
Sl.
No. Description Residential Commercial
Institutional zone
Educational,
Public and Semi
public
Industrial
1. Minimum plot
extent
220 sq.m. 300 sq.m.
---
2. Minimum plot
width/frontage
9m 9m ---
3. Minimum road
width
9m 9m 9m 9m.
4. Maximum height of
building
15m or G+3 floors
or stilt + 4 floors
15m or G+3 (or)
Stilt+4 floors
15m or G+3 (or)
Stilt+4 floors
15m. Provided
that water tank,
chimneys,
bunkers, silos
etc. which are
not intended to
human habitation
may be permitted
subject to a
ceiling of 30m.
from the ground
level.
5. Maximum Floor
Space Index (FSI)
1.5 1.5 1.5 1.00
6. Maximum plot
coverage
70% 65% 60% 50%
7. Front set back Min – 3m.
Upto 18m–3m.
18m to 24m –
4.5m.
More than 24m, NH
& SH – 7m
Min – 3m.
Upto 18m–3m
18m to
24m – 4.5m.
More than 24m &
NH & SH –
7m.
Min – 3m.
Upto 18m–3m
18m to
24m – 4.5m.
More than 24m &
NH & SH – 7m.
Min – 3m.
Upto 18m–3m
18m to
24m – 4.5m.
More than 24m &
NH & SH –
7m.
8. Side set back 3m or 1/4th height
whichever is higher
3m. or 1/4th
height whichever
is higher
3m. or 1/4th height
whichever is
higher
3m or 1/4th height
whichever is
hiher
9. Rear set back . 3m. or 1/4th height
whichever is higher
3m. or 1/4th
height whichever
is higher
3m. or 1/4th height
whichever is
higher
3m. or 1/4th
height whichever
is higher
10. Open Spare
Reservation (OSR)
It shall be followed as per Schedule-I.
11. Parking space As mentioned in Schedule-II will be followed.
use’ as defined in section 2(11) of the Act, shall be eligible for FSI permissible for commercial use. This shall be decided by the
technical committee of the directorate on case to case basis.
(3) For public buildings such as theatres, kalyana mandapams, assembly halls, exhibition halls, hospitals, nursing homes,
hotels, lodging houses, etc. set back all around shall not be less than 6 metres.
(4) The reservation of land for community recreational purposes such as parks or play ground required in these regulations
shall be as given in Schedule-I.
June 16, 2010] TAMIL NADU GOVERNMENT GAZETTE 337
(5) Information Technology buildings shall comply with all the provisions mentioned in Schedule-VII.
4. Group development.—(1) Group Development means accommodation for residential, commercial or institutional building
in two or more blocks of buildings in a particular site irrespective of whether these structures are interconnected or not. Any inter
link between the structures in terms of connecting corridors shall not be construed as making any two structures into one block.
However, if these blocks are connected solidly atleast for one-third the width of any one block on the connecting side, then such
block shall be construed as a single block.
(2) (a) The minimum width of the public road on which the site abuts or gains access shall be 9 metres.
Explanation.- The qualifying road width for permitting Group development shall be available for a reasonable stretch say about
250 metres along the length of the road abutting the site and the stretch from a junction can be straight or a curve or zigzag or
combination of the above. Any deviation on road width shall be referred to Empowered Committee whose decision shall be final.
To cite examples.–
(i) If the road over its general length is of 9 metres width, but because of some kinks in front of the site the two ends show
a minor variations, reasonable allowance for such variation may be given so that it averages out to 9 metres.
(ii) If the general road is of width less than 9 metres width, but only widens opposite to or nearer to the site is more than
9 metres, is not acceptable.
(iii) If the general road is of 9 metres width upto a considerable length on one side, but discontinues and narrows into a
road of smaller width on the other side of the site in question and the plot owner is willing to leave enough space for continuity
of 9 metres road in front of his site, this will have to be checked and decided on case-by-case and such cases may be referred
to Empowered Committee.
(iv) If the general road width is less than 9 metres and the site owner merely agrees to leave enough space to have 9
metres in front of his site only, this is not acceptable.
(v) Road width measurements for the above purpose shall be of the road as designed and laid and the existence of
unauthorised encroachments, for which no patta has been given, will not normally affect adversely provided the shortage in width
in the minimum stretch stated above does not exceed 10% of the minimum prescribed width. However permissibility or otherwise
(in exceptional cases) in such specific situations will be decided case-by-case and these may be referred to Empowered
Committee.
(b) If the site does not directly abut a public road but gains access through a private exclusive passage or through a part
of the plot which can be treated as a passage from a public road of minimum width as prescribed above, the minimum width of
such passage shall be as follows:—
(3) The extent of site, FSI, Set back etc. for Group development shall be regulated according to the Table below:-
Sl.
No. Description Minimum width
(1) When it is intended to serve 8 dwelling or upto 600 square metres of
commercial building and the length of the passage does not exceed 80
metres
3.6 metres
(2) When it is intended to serve upto 10 dwellings or upto 2,400 square
metres of commercial building and the length of the passage does not
exceed 100 metres
4.8 metres
(3) When it is intended to serve not more than 15 dwellings or upto 3000
square metres of commercial building and the length of passage does not
exceed 120 metres
7.2 metres
(4) When it is intended to serve more than 15 dwellings or more than 3000
square metres of commercial building
9.0 metres
338 TAMIL NADU GOVERNMENT GAZETTE [Part II—Sec. 2
THE TABLE.
Note: (i) For public buildings such as theatres, kalyana mandapams, assembly halls, exhibition halls, hospitals, nursing homes,
hotels, lodging houses, etc. setback all around shall not be less than 6 metres.
(ii) In case of hospital buildings an additional FSI of 0.25 is allowable over and above the normally permissible FSI.
(iii) Additional FSI of 20% shall be permissible if stilt parking is provided.
(iv) Buildings otherwise meant as public buildings but qualify the definition of ‘commerce’ in section 2(10) and ‘commercial
use’ in section 2(11) of the Act shall be eligible for FSI meant for commercial use. This shall be decided by the technical committee
of the directorate on case-by-case basis.
(v) In case of Information Technology buildings, further regulations as detailed in Schedule – VII shall prevail and complied
with.
(vi) Cases involving exemptions, clarification etc. may be referred to Empowered Committee.
(4) Structures permissible in the minimum prescribed Front setback, side setback and rear setback are given in
Schedule – III.
(5) The minimum width of corridor shall be as given below:—
(6) Parking spaces shall be provided within the site conforming to the regulations given in Schedule – II.
(7) Special regulations for physically disabled shall be adhered to as given in the Schedule – IV.
Sl.
No. Description General area
(1) (2) (3)
A Minimum plot extent 500 square metres.
B Minimum plot width / frontage 12 metres.
C Maximum FSI 1.5
D Minimum setbacks
(i) Front setback Based on road width
(i) NH/SH – 7m.
(ii) Other road upto 12 m – 3 m
12 m to 18 m – 4.5 m.
more than 18 m – 6 m.
(ii) Side setback G+2 or Stilt + 3 floors
subject to a maximum of
12 m.
3.5 m on either side
G+3 or Stilt + 4 floors
subject to a maximum of
15 m.
4.5 m on either side
(iii) Rear setback 3.5 metres 4.5 metres
(iv) Spacing between blocks 6 metres
Sl.
No. Building use or type Minimum width of
corridor
(i) Residential buildings 1.0 metres
(ii) Assembly buildings such as Auditoriums, Kalyanamandapams, cinema
theatres, Religious buildings, temples, mosques or churches and other
buildings of public assembly or conference
2.0 metres
Institutional building such as:
a) Government offices 2.0 metres
b) Hospitals 2.4 metres
c) Educational buildings such as schools, colleges, research institutions 2.0 metres
d) Commercial buildings such as private offices, nursing homes, lodges, etc. 2.0 metres
(iii)
e) All other buildings 1.5 metres
June 16, 2010] TAMIL NADU GOVERNMENT GAZETTE 339
(8) Rain water conservation given in Schedule – V.
(9) Solar energy capture provisions shall be provided where applicable as given below:
New buildings in the following categories shall be provided with the ancillary solar assisted solar heating system and it shall
be shown in the plans for developments applied for planning permission:
a) Nursing homes / hospitals exceeding 500 square metres in the floor area;
b) Hotels and lodges exceeding 500 square metres in floor area;
c) Hostels exceeding 50 rooms; and
d) Kalyanamandapams exceeding 500 square metres in floor area.
(10) The reservation of land for community recreational purposes such as park or play ground required in these regulations
shall be as given in Schedule – I.
(11) Internal vehicular access way including passage if any within the site shall be a clear width of 7.2metre and such vehicular
access shall be available for every building block in the site within a distance of 50 metres. Further, it shall be a clear open
to sky and no projection of structure over it is permissible.
(12) If the building is constructed on stilts and the stilt floor is to be used for parking, the minimum clear height of the floor
(between the lower floor and the bottom of the beam) shall not exceed 3.0 metres and it shall not be enclosed for use
as garages; if it is enclosed it shall be counted for FSI and number of floors for the purpose of defining Group development
/ Multi-storeyed building.
(13) If a Group development contains more than one use and the allowability of the building space with reference to the abutting
road width and exclusive passage width shall be decided based on the number of dwellings for a residential use and the
equivalent floor area allowable for commercial and other uses.
(14) Every Group development exceeding 900 square metre in floor area shall be provided with electrical room in ground floor
or open space at ground level within the premises to accommodate electrical transformer conforming to the Tamil Nadu
Electricity Board standard and Fire Rescue Service standard as mentioned in Schedule – VIII.
(15) Vehicular ramp in set back spaces around building blocks may be permitted subject to the condition that the clearance
of the proposed ramp from the property boundary/street alignment shall be minimum 1.5 metres and a clear motorable
driveway of minimum 3.5 metres in width is available around the building block.
(16) The structures incidental to the main activities such as water closet/pump room, transformer room, transformer yard,
electric room shall not be construed as transformer room, transformer yard, electric room shall not be construed as
individual block for the purpose of these rules. However, these structures may be permitted in the prescribed set back
space provided that they do not fall in the drive way and its height does not exceed 4 metres provided further that
transformer and electrical rooms floor area does not exceed 15 square metres and water closet and pump room per block
does not exceed 6 square metres.
(17) In cases of residential developments exceeding 100 dwelling units in primary residential use zone, commercial and
institutional uses not exceeding 10 per cent of the floor area of the building at lower habitable floor levels, may be allowed
(not for any industrial use) as incidental uses required for the occupants of the remaining residential developments within
the premises.
(18) In all such developments, sewage treatment plant shall be provided and maintained for the disposal of the sewage within
the site itself;
(19) Any construction with roof cover it in the terrace floor for A.C. Plant/ structures shall be counted, as a floor and
categorisation of type of building shall be done accordingly.
(20) In cases where the extent of the site where residential or predominantly residential developments proposed exceeds 10000
square metres (1 hectare), the developer shall reserve minimum ten per cent of the site area (excluding roads if any
handed over to local body) and provide housing thereon for lower income groups with dwelling units not exceeding 45
square metres in floor area each, either within the site proposed for group development or in a location within a radius
of 5 k.m. from the site under reference. The developer or promoter or owner shall sell these small dwellings only for this
purpose. No conversion or amalgamation shall be permissible in these cases of lower income group dwellings.
(21) In residential / predominantly residential developments with dwelling units exceeding 20 in number, the design should
include waste management infrastructure and atleast a closed non polluting storage provision for solid waste storage
within the premises preferably with direct access from the abutting road shall be provided so that the local body can collect
340 TAMIL NADU GOVERNMENT GAZETTE [Part II—Sec. 2
this stored waste from it.
(22) In the interest of the public for better circulation in the area and also to ensure the proposed development does not block
access to the properties around, in cases of large developments where link roads have to be provided for connectivity to
the adjoining lands/areas, through the site applied for development, the Authority reserves the right to insist the applicant
to set apart such road spaces within the site and the applicant shall hand over the same free of cost through a registered
gift deed to the authority or Local body designated by it for declaring it as public road. In such cases set back from these
roads to the buildings proposed shall be provided as prescribed in these regulations.
(23) The space set apart for formation of a new road proposal in Master Plan/Detailed Development Plan or road widening/
street alignment shall be transferred to the relevant Authority or the Agency or the Local Body through a registered Gift
Deed before actual issuance of planning permission. The exact mode of conveyance of the land shall be consistent with
the relevant enactment and regulations.
(24) Basement Floor;-
(a) The height of basement floor shall not exceed 1.2 metres above ground level and the headroom shall be minimum
2.4 metres.
(b) No part of the basement shall be constructed in the minimum required set back spaces, required for the movement
of fire fighting vehicles/equipments.
(c) In cases where second basement is proposed for parking and incidental uses, sufficient provision for lighting and
ventilation and also for protection from fire to the satisfaction of Directorate of Fire and Rescue Services shall be
made.
(d) During the construction of the basement floor, it shall be sole responsibility of the planning permission holder to ensure
that the building / structure in the adjoining sites are not weakened / damaged.
(25) Display Board.-—The details of the development for which planning permission issued, date of expiry of permit etc. shall
be displayed in the format prescribed by the Authority on a board of size at least 60cm x 120cm.
5. Multi-storeyed Building.—“Multi-storeyed building” means a building exceeding 4 floors (including ground floor or if this
ground floor is used for parking under stilts, stilt floor + 4 floors) whose height is 15 m or more.
(1) (a) Site Extent.—The minimum extent of site for construction of multi-storeyed building shall not be less than 1500
square metres.
(b) Road width.—The site shall either abut on a road not less than 18 metres in width or gain access from public
road not less than 18 metres in width through a part of the site which can be treated as an exclusive passage
of not less than 18 metres in width.
Provided further that multi-storeyed building may be permitted with limitations on maximum FSI and maximum height of
the building on a site abutting or gaining access from a public road of minimum 12 metres / 15 metres in width, or gain access
from public road not less than 12metres / 15metres in width through a part of the site which can be treated as an exclusive
passage of not less than 12 m / 15 metres in width, subject to compliance of the planning parameters stated in the Table sub-
regulation (2) below.
(c) Minimum road width of 12 metre or above shall be permissible with Multi-storeyed buildings without any further
procedures. The height of Multi-storeyed buildings will be technically correlated with the width of the abutting
road. Once the road width is established based on records, these areas may be permitted with Multi-storeyed
buildings. Special consideration may be given to any specific recommendation to the contrary of above rule. No
further resolutions or otherwise will be required. In case of doubts or clarification or any related issue
Empowered Committee shall take a final decision.
Explanation.—Road width means whole extent of space within the boundaries of the road / street measured at right angles to
the course of direction of such road / street. The qualifying road width for permitting multi-storeyed building shall be available atleast
for a stretch of 500 metres along the length of the road abutting the site and the stretch from a junction can be straight or a curve
or zigzag or combination of the above.
To cite examples-
(a) If the road over its general length is of 18 metres width, but because of some kinks in front of the site one end is
17.8 metres and the other end is 18.2 metres is acceptable.
(b) If the general road is of width less than 18 metres width, but only widens opposite to or nearer to the site is more
than 18 metres, is not acceptable.
(c) If the road is generally of 18 metres width upto a considerable length on one side, but discontinues and narrows into
June 16, 2010] TAMIL NADU GOVERNMENT GAZETTE 341
a road of smaller width on the other side of the site in question and the plot owner is willing to leave enough space
for continuity of 18 metres road in front of his site, this will have to be checked and decided on case-by-case. This
should be referred to Empowered Committee for appropriate decision.
(d) If the general road width is less than 18 metres and the site owner merely agrees to leave enough space to have
18 metres in front of his site only, this is not acceptable.
(2) The extent of the site, FSI, set back etc., for Multi-storeyed Building shall be regulated according to the Table below:—
Note: (i) The space specified above shall be kept open to sky and free from any erection / projection (such as sunshade /
Sl.
No. Description Category I(a) Cateogry
I(b) Category II Category III
A. Minimu
Previous and next
Questions people ask
Is regulation 11 of Development Control Regulations still in force?
No repeal of Development Control Regulations is recorded.