5. Multi-storeyed Building.--
"Multi-storeyed building" means a building exceeding 4 floors (including ground
floor or if this ground floor is used for parking under stilts, stilt floor + 4 floors)
whose height is 15 m. or more.
https://www.manupatrafast.com/pers/viewdoctoc.aspx?sPath=Bare%20Acts%20and%20Rules/State/tamil%20nadu/Rules/tamil%20nadu/tamil%20nadu%20town%20and%20country%20planning%20act%201971/DeCoReErVeGuKaSaChTiLoPlAr/DeCoReErVeGuKaSaChTiLoPlAr.htm&col=8Vmp9ozFMb/2ISz1SdixCIRVngsjs/j1lxFukHhUlVjtLjdB0bd4mmFTJWUx/aBSKBdGFQIME6VoesAFaCGBewHrWR8ddcNQuL7JwN7hYU7qHizMrFQj4LFUvb7Bkchar(43)6o706GyNkh4BCUcuVcjmbGhejF08ykNubEvKW4zqo890cktJ88vxBo32cc1YJmu9Dc/5IUlIm3BdNjSABchar(43)2R9TRHZChuWg9X1a6Zdqtl8E2/Y=#F2
https://www.manupatrafast.com/TOC/TocDisplay.aspx?col=8Vmp9ozFMb/2ISz1SdixCIRVngsjs/j1lxFukHhUlVjtLjdB0bd4mmFTJWUx/aBSKBdGFQIME6VoesAFaCGBewHrWR8ddcNQuL7JwN7hYU7qHizMrFQj4LFUvb7Bkchar(43)6o706GyNkh4BCUcuVcjmbGhejF08ykNubEvKW4zqo890cktJ88vxBo32cc1YJmu9Dc/5IUlIm3BdNjSABchar(43)2R9TRHZChuWg9X1a6Zdqtl8E2/Y=&path=Bare%20Acts%20and%20Rules/State/tamil%20nadu/Rules/tamil%20nadu/tamil%20nadu%20town%20and%20country%20planning%20act%201971/DeCoReErVeGuKaSaChTiLoPlAr/Toc.htm#to
(1) (a) Site Extent.--
The minimum extent of site for construction of multi-
storeyed building shall not be less than 1,500 square
metres.
(b) Road width.--
The site sh3all either abut on a road not less than 18 metres
in width or gain access from public road not less than 18
metres in width through a part of the site which can be
treated as an exclusive passage of not less than 18 metres
in width:
Provided further that multi-storeyed building may be
permitted with limitations on maximum FSI and
maximum height of the building on a site abutting or
gaining access from a public road of minimum 12
metres/15 metres in width, or gain access from public
road not less than 12metres/15metres in width
through a part of the site which can be treated as an
exclusive passage of not less than 12 metres/15
metres in width, subject to compliance of the
planning parameters stated in the Table sub-
regulation (2) below.
(c) Minimum road width of 12 metre or above shall be permissible
with multi-storeyed buildings without any further procedures. The
height of multi-storeyed buildings will be technically correlated with
the width of the abutting road. Once the road width is established
based on records, these areas may be permitted with multi-
storeyed buildings. Special consideration may be given to any
specific recommendation to the contrary of above rule. No further
resolutions or otherwise will be required. In case of doubts or
clarification or any related issue, Empowered Committee shall take
a final decision.
Explanation.-- Road width means whole extent of space
within the boundaries of the road/street measured at right
angles to the course of direction of such road/street. The
qualifying road width for permitting multi-storeyed building
shall be available at least for a stretch of 500 metres along
the length of the road abutting the site and the stretch from
a junction can be straight or a curve or zigzag or
combination of the above.
To cite examples:--
(a) If the road over its general length is of 18 metres
width, but because of some kinks in front of the site
one end is 17.8 metres and the other end is 18.2
metres is acceptable.
(b) If the general road is of width less than 18 metres
width, but only widens opposite to or nearer to the
site is more than 18 metres, is not acceptable.
(c) If the road is generally of 18 metres width upto a
considerable length on one side, but discontinues and
narrows into a road of smaller width on the other side
of the site in question and the plot owner is willing to
leave enough space for continuity of 18 metres road
in front of his site, this will have to be checked and
decided on case-by-case. This should be referred to
Empowered Committee for appropriate decision.
(d) If the general road width is less than 18 metres
and the site owner merely agrees to leave enough
space to have 18 metres in front of his site only, this
is not acceptable.
(2) The extent of the site, FSI, set back, etc., for multi-storeyed Building
shall be regulated according to the Table below:--
Sl.
No.
Description. Category
1(a).
Category
1(b).
Category
II.
Category III.
A: Minimum plot
extent.
1200 sq.
m.
1200 sq.
m.
1500 sq.
m.
2500 sq. m.
B. Minimum Plot
width/frontage.
25 m. 25 m. 25 m. 40 m.
C. Minimum road
width.
12 m. 15 m. 18 m.
P. Maximum FSI. 1.5 1.75 2.50 2.25 2.00
E. Maximum
coverage.
30% 30% 30% Above
30%
upto
40%.
Above
40%
upto
50%.
F. Maximum
height above
Ground Level.
G + 6 or
Stilt + 7
floors
subject to
a
maximum
24 m.
G+8 Stilt
+ 9 floors
subject to
a
maximum
30 m.
60 metre where the width
of the abutting road is
minimum 18 metre, and
exceeding 60 metre where
the width of abutting road
is minimum 30.5 metres,
subject to such conditions
as may be necessary. 2[In
case of Hospital buildings,
the maximum permissible
height is 30 metres.]
Height of the building
above ground level
Minimum required setback
space from the property
boundary.
G. Minimum set
back all
around.
Above 15 m. up to 30
m.
7 m.
Above 30 m. For every increase in
height of 6 m. or part
thereof above 30 m.
minimum extent of setback
space to be left additionally
shall be one metre.
H. Spacing
between block
in case of
group
developments.
Height of the building
above ground level.
Minimum required spacing
between blocks.
Above 15 m. up to 30
m.
7 m.
Above 30 m. For every increase in
height of 6 m. or part
thereof above 30 m. space
to be left additionally shall
be one metre.
Note: (i) The space specified above shall be kept open to sky and
free from any erection/projection (such as sunshade/balcony) of
any building other than a fence or compound wall provided that
these open yards may be used for the provision of access ways to
the building's parking facilities.
https://www.manupatrafast.com/pers/viewdoctoc.aspx?sPath=Bare%20Acts%20and%20Rules/State/tamil%20nadu/Rules/tamil%20nadu/tamil%20nadu%20town%20and%20country%20planning%20act%201971/DeCoReErVeGuKaSaChTiLoPlAr/DeCoReErVeGuKaSaChTiLoPlAr.htm&col=8Vmp9ozFMb/2ISz1SdixCIRVngsjs/j1lxFukHhUlVjtLjdB0bd4mmFTJWUx/aBSKBdGFQIME6VoesAFaCGBewHrWR8ddcNQuL7JwN7hYU7qHizMrFQj4LFUvb7Bkchar(43)6o706GyNkh4BCUcuVcjmbGhejF08ykNubEvKW4zqo890cktJ88vxBo32cc1YJmu9Dc/5IUlIm3BdNjSABchar(43)2R9TRHZChuWg9X1a6Zdqtl8E2/Y=#F2
(ii) A watchman or caretaker booth or Kiosk not exceeding
2.5 m. x 2.5 m. in size at each gate and not exceeding 3
metre in height, or power/transformer room not exceeding 4
metre in height shall be permitted in the set backspace at
ground level after leaving 7 metres clear set back from the
main structure. Provided that the height restriction shall not
apply for an open transformer.
(iii) Gate pillars without or with arches with a minimum
headroom clearance of 5.50 metre at least to a width of 3.5
metre, may be permitted in the set back space after leaving
7 metres clear set back from the main structure.
(iv) In the cases where street alignment has been
prescribed, the front open space shall be left from the street
alignment.
(v) In cases of hospital buildings, an additional Floor Space
Index of 0.25 is allowable over and above the normally
permissible FSI.
(vi) The Floor Space Index for Information Technology
development shall be allowed at 1.5 times of the FSI
ordinarily permissible for respective use of that zone
provided the site extent is not less than 2,000 sq. m. This
benefit will not be available for primary residential use zone.
Explanations.--
(1) Parking and par3king facilities.
For the use of the occupants and of persons visiting
the premises for the purposes of profession, trade,
business, recreation or any other activity, parking
spaces and parking facilities shall be provided within
the site to the satisfaction of the Authority and
conforming to the standards specified in Schedule-II.
(2) Vehicular access within the site.
Internal vehicular access way including passage, if
any, within the site, shall have a clear width of 7.2
metre and such vehicular access shall be available for
every building block in the site. Further, it shall be a
clear width of open to sky and no projection in
structure over it is permissible.
(3) Corridor width.-- The corridor serving as access
for units in the development in whichever floor they
may be situated shall not be less than the standards
prescribed in the Table below:--
TABLE
Sl.
No.
Building use or type. Minimum
width of
corridor.
(i) Residential buildings. 1.0 metres.
(ii) Assembly buildings such as Auditoriums,
Kalyanamanda-pams, cinema theatres, religious
buildings, temples, mosques or churches and
other buildings of public assembly or
conference.
2.0 metres.
(iii) Institutional building such as--
(a) Government offices ; 2.0 metres.
(b) Hospitals ; 2.4 metres.
(c) Educational buildings such as schools,
colleges, research institutions ;
2.0 metres.
(d) Commercial buildings such as private
offices, nursing homes, lodges, etc.;
2.0 metres.
(e) All other buildings. 1.5 metres.
(4) Basement Floor.-
(a) The height of basement floor shall not exceed 1.2
metres above ground level and the headroom shall be
minimum 2.4 metres.
(b) No part of the basement shall be constructed in
the minimum required set back spaces required for
the movement of snorkel.
(c) In cases where second basement is proposed for
parking and incidental uses, sufficient provision for
lighting and ventilation and also for protection from
fire to the satisfaction of Directorate of Fire and
Rescue Services shall be made.
(d) During the construction of the basement floor, it
shall be sole responsibility of the planning permission
holder to ensure that the building/structure in the
adjoining sites are not weakened/damaged.
(5) The reservation of land for community
recreational purposes such as park or play ground
required in these regulations shall be as given in
Schedule-I.
(6) Conformance to National Building Code of India.--
(a) In so far as the determination of sufficiency of all
aspects of structural designs, building services,
plumbing, fire protections, construction practice and
safety are concerned, the specifications, standards
and code of practices recommended in the National
Building Code of India shall be fully conformed to and
any breach thereof shall be deemed to be a breach of
the requirements under these regulations.
(b) Every multi-storeyed development erected shall
be provided with,--
(i) lifts as prescribed in National Building Code ;
(ii) a stand-by electric generator of adequate capacity
for running lift and water pump, and a room to
accommodate the generator;
(iii) an electrical room of not less than 6 metres by
4.0 metres in area with a minimum head room of
2.75 metres to accommodate electric transformer in
the ground floor ; and the space for installation of
transformers shall conform to the regulation given in
Schedule-VIII; and
(iv) at least one metre room of size 2.4 metres by 2.4
metres for every 10 consumers or 3 floors whichever
is less. The metre room shall be provided in the
ground floor.
(7) Fire safety, detection and extinguishing systems.-
-
(a) All building in their design and construction shall
be such as to contribute to and ensure individually
and collectively and the safety of life from fire,
smoke, fumes and also panic arising from these or
similar other causes.
(b) In building of such size, arrangement or
occupancy that a fire may not itself provide adequate
warning to occupants, automatic fire detecting and
alarming facilities shall be provided where necessary
to warn occupants or the existence of fires, so that
they may escape, or to facilitate the orderly conduct
of fire exit drills.
(c) Fire protecting and extinguishing system shall
conform to accepted standards and shall be installed
in accordance with good practice as recommended in
the National Building Code of India, (amended from
time to time) and to the satisfaction of the Director of
Fire and Rescue Services by obtaining a no objection
certificate from him.
(8) In cases of residential developments exceeding 50
dwelling units in primary residential use zone,
commercial and institutional uses not exceeding 10
per cent of the floor area of the building at lower
habitable floor levels, may be allowed (not for any
industrial use) as incidental uses required for the
occupants of the remaining residential developments
within the premises.
(9) The design and plans of the building shall be
made and signed by a qualified Civil or Structural
Engineer and an Architect who should possess the
qualification referred to in the Architects Act, 1972
(Central Act 20 of 1972), so as to become a member
of the profession of Architects under the provisions of
the said Act. The qualified Engineer or Structural
Engineer should also be Class I Licensed Surveyor
registered with the Corporation/Local Body
concerned.
(10) Display Board.--
The details of the developments for which planning
permission issued, date of expiry of permit, etc. shall
be displayed in the format prescribed by the Authority
on a board of size at least 60 cm. x 120 cm.
(11) In all the development, sewage treatment plant
shall be provided and maintained for the disposal of
the sewage with design clearance from Pollution
Control Board. For smaller development, as per
direction of planning authority, septic tank with up-
flow filters shall be provided and maintained for the
disposal of the sewage within the site itself.
(12) In cases where the extent of the site where
residential or predominantly residential developments
proposed exceeds 10,000 square metre (1 hectare),
the developer shall reserve minimum ten per cent of
the site area (excluding roads, if any, handed over to
local body) and provide housing thereon for lower
income groups with dwelling units not exceeding 45
square metre in floor area each, either within the site
proposed for Multi-storeyed Building development or
in a location within a radius of 5 kilometres from the
site under reference. The developer or promoter or
owner shall sell these small dwellings only for this
purpose. No conversion or amalgamation shall be
permissible in these cases of lower income group
dwellings.
(13) In residential/predominantly residential
developments with dwelling units exceeding 20 in
number, the design should include waste
management infrastructure with segregation at
source and at least a closed non-polluting storage
provision for solid waste storage within the premises
preferably with direct access from the abutting road
shall be provided so that the local body can collect
this stored waste from it.
(14) In the interest of the public for better circulation
in the area and also to ensure that the proposed
development does not block access to the properties
around, in cases of large developments where link
roads have to be provided for connectivity to the
adjoining lands areas, through the site applied for
development, the relevant Authority reserves the
right to insist the applicant to set apart such road
spaces within the site and the applicant shall hand
over the same free of cost through a registered gift
deed to the Authority or local body designated by it
for declaring it as public road. In such cases, set back
from these roads to the buildings proposed shall be
provided as prescribed in these regulations.
(15) The space set apart for formation of a new road
as per Master Plan or Detailed Development Plan or
road widening/street alignment shall be transferred to
the respective Authority or the Agency or the Local
Body through a registered Gift Deed before actual
issuance of planning permission. The exact mode of
conveyance of the land shall be consistent with the
relevant enactment and regulations.
(16) Rain water conservation shall be provided as
given in Schedule-V.
1(17) Solar Photo Voltaic system shall be mandatory
and shall be provided as prescribed in Schedule IX.]
(18) Civil Aviation height and activity restrictions shall
be adhered to. In cases where helipads are proposed
at terrace of commercial/industrial multi-storeyed
buildings, clearance of civil aviation department shall
be produced.
(19) Special regulations for physically disabled shall
be adhered to as in Schedule-IV.
(20) Scrutiny of the plan.--
The plan shall be scrutinised as per rule 15 of the
Tamil Nadu Multi-storeyed and Public Building Rules,
1973.
3(21) Special Regulation for Hospital buildings shall
be adhered to as given in Schedule-XIL]
https://www.manupatrafast.com/pers/viewdoctoc.aspx?sPath=Bare%20Acts%20and%20Rules/State/tamil%20nadu/Rules/tamil%20nadu/tamil%20nadu%20town%20and%20country%20planning%20act%201971/DeCoReErVeGuKaSaChTiLoPlAr/DeCoReErVeGuKaSaChTiLoPlAr.htm&col=8Vmp9ozFMb/2ISz1SdixCIRVngsjs/j1lxFukHhUlVjtLjdB0bd4mmFTJWUx/aBSKBdGFQIME6VoesAFaCGBewHrWR8ddcNQuL7JwN7hYU7qHizMrFQj4LFUvb7Bkchar(43)6o706GyNkh4BCUcuVcjmbGhejF08ykNubEvKW4zqo890cktJ88vxBo32cc1YJmu9Dc/5IUlIm3BdNjSABchar(43)2R9TRHZChuWg9X1a6Zdqtl8E2/Y=#F1
https://www.manupatrafast.com/pers/viewdoctoc.aspx?sPath=Bare%20Acts%20and%20Rules/State/tamil%20nadu/Rules/tamil%20nadu/tamil%20nadu%20town%20and%20country%20planning%20act%201971/DeCoReErVeGuKaSaChTiLoPlAr/DeCoReErVeGuKaSaChTiLoPlAr.htm&col=8Vmp9ozFMb/2ISz1SdixCIRVngsjs/j1lxFukHhUlVjtLjdB0bd4mmFTJWUx/aBSKBdGFQIME6VoesAFaCGBewHrWR8ddcNQuL7JwN7hYU7qHizMrFQj4LFUvb7Bkchar(43)6o706GyNkh4BCUcuVcjmbGhejF08ykNubEvKW4zqo890cktJ88vxBo32cc1YJmu9Dc/5IUlIm3BdNjSABchar(43)2R9TRHZChuWg9X1a6Zdqtl8E2/Y=#F3
Previous and next
Questions people ask
Is regulation 5 of Development Control Regulations for Erode/Veuore/Tiruveuore/Coimbatore/Madurai/Gummudipoondi/Kancheepuram/Salem/Chengalpattu/Tiruppur/Tiruchirappalli Local Planning Area still in force?
No repeal of Development Control Regulations for Erode/Veuore/Tiruveuore/Coimbatore/Madurai/Gummudipoondi/Kancheepuram/Salem/Chengalpattu/Tiruppur/Tiruchirappalli Local Planning Area is recorded.