Regulation 3, Development Control Regulations for Erode/Veuore/Tiruveuore/Coimbatore/Madurai/Gummudipoondi/Kancheepuram/Salem/Chengalpattu/Tiruppur/Tiruchirappalli Local Planning Area: Regulation for special building
Development Control Regulations for Erode/Veuore/Tiruveuore/Coimbatore/Madurai/Gummudipoondi/Kancheepuram/Salem/Chengalpattu/Tiruppur/Tiruchirappalli Local Planning Area - Regulation 3
Text of regulation 3
Regulation for special building
3. Regulation for special building.--
(1) "Special buildings" means--
(a) a residential or commercial buildings with more than two floors ; or
(b) a residential building with more than four dwelling units ; or
(c) a commercial building exceeding a floor area of 300 square metre:
Provided that any construction in the second floor with prior
permission as an addition to an existing ground and first storeyed
authorised ordinary residential building which is three years old
shall not be construed as a "special building".
(2) The minimum width of the public road on which the site abuts or gains access
shall be 9 metres.
Explanation.--
(i) The qualifying road width for permitting special building shall be
available at least for a reasonable stretch about 250 metres along
the length of the road abutting the site and the stretch from a
https://www.manupatrafast.com/TOC/TocDisplay.aspx?col=8Vmp9ozFMb/2ISz1SdixCIRVngsjs/j1lxFukHhUlVjtLjdB0bd4mmFTJWUx/aBSKBdGFQIME6VoesAFaCGBewHrWR8ddcNQuL7JwN7hYU7qHizMrFQj4LFUvb7Bkchar(43)6o706GyNkh4BCUcuVcjmbGhejF08ykNubEvKW4zqo890cktJ88vxBo32cc1YJmu9Dc/5IUlIm3BdNjSABchar(43)2R9TRHZChuWg9X1a6Zdqtl8E2/Y=&path=Bare%20Acts%20and%20Rules/State/tamil%20nadu/Rules/tamil%20nadu/tamil%20nadu%20town%20and%20country%20planning%20act%201971/DeCoReErVeGuKaSaChTiLoPlAr/Toc.htm#to
https://www.manupatrafast.com/TOC/TocDisplay.aspx?col=8Vmp9ozFMb/2ISz1SdixCIRVngsjs/j1lxFukHhUlVjtLjdB0bd4mmFTJWUx/aBSKBdGFQIME6VoesAFaCGBewHrWR8ddcNQuL7JwN7hYU7qHizMrFQj4LFUvb7Bkchar(43)6o706GyNkh4BCUcuVcjmbGhejF08ykNubEvKW4zqo890cktJ88vxBo32cc1YJmu9Dc/5IUlIm3BdNjSABchar(43)2R9TRHZChuWg9X1a6Zdqtl8E2/Y=&path=Bare%20Acts%20and%20Rules/State/tamil%20nadu/Rules/tamil%20nadu/tamil%20nadu%20town%20and%20country%20planning%20act%201971/DeCoReErVeGuKaSaChTiLoPlAr/Toc.htm#to
junction can be straight or a curve or zigzag or combination of the
above. Over this length, minor variation in road width at two ends
may be considered provided width average outs to 9 metres.
To cite examples:--
(a) If the general road is of width less than 9 metres
width, but only widens opposite to, or nearer to, the
site is more than 9 metres, is not acceptable.
(b) If the road is generally of 9 metres width upto a
considerable length on one side, but discontinues and
narrows into a road of smaller width on the other side
of the site in question and the plot owner is willing to
leave enough space for continuity of 9 metres road in
front of his site, this will have to be checked and
decided on case-by-case. Reference in such cases
may be made to Empowered Committee.
(c) If the general road width is less than 9 metres
and the site owner merely agrees to leave enough
space to have 9 metres in front of his site only, this is
not acceptable.
(ii) Road width measurements for the above purpose shall be of the
road as designed and laid and the existence of unauthorised
encroachments, for which no patta has been given, will not
normally affect adversely, provided the shortage in width in the
minimum stretch stated above does not exceed 10% of the
minimum prescribed width. However, permissibility or otherwise in
such specific situations will be decided case-by-case. Reference in
such cases may be made to Empowered Committee.
(3) Planning Parameters.--
The extent of the site, plot coverage, FSI, set back, etc. for the
developments shall be regulated according to the Table below:--
Sl.
No.
Description. Residential. Commercial. Institutional
zone
Educational,
Public and
Semi-
public.
Industrial.
1. Minimum plot
extent.
220 sq. m. 300 sq. m.
2. Minimum plot
width/frontage.
9 m. 9 m.
3. Minimum road
width.
9 m. 9 m. 9 m. 9 m.
4. Maximum
height of
building.
15 m. or
G+3 floors
or stilt + 4
floors.
15 m. or
G+3 (or)
Stilt + 4
floors.
15m. or
G+3 (or)
Stilt + 4
floors.
15 m.
Provided
that
water
tank,
chimneys,
bunkers,
silos, etc.
which are
not
intended
to human
habitation
may be
permitted
subject to
a ceiling
of 30 m.
from the
ground
level.
5. Maximum Floor
Space Index
(FSI).
1.5 1.5 1.5 1.00
6. Maximum plot
coverage.
70% 65% 60% 50%
7. Front set back. Min -3 m.
Upto 18 m.
-3 m. 18
m. to 24
m. -4.5 m.
More than
24 m., NH
Min -3 m.
Upto 18 m-
3 m. 18 m.
to 24 m. -
4.5 m. More
than 24 m.
& NH & SH-
Min -3 m.
Upto 18 m.-
3 m. 18 m.
to 24 m.-
4.5 m. More
than 24 m.
& NH & SH-
Min -3 m.
Upto 18
m.-3 m.
18 m. to
24 m.-4.5
m. More
than 24
& SH-7 m. 7m. 7 m. m. & NH
& SH-7
m.
8. Side set back. 3 m. or
l/4th,
height
whichever
is higher.
3 m. or
l/4th, height
whichever is
higher.
3 m. or
l/4th,
height
whichever
is higher.
3 m. or
l/4th,
height
whichever
is higher.
9. Rear set back. 3 m. or
l/4th,
height
whichever
is higher.
3 m. or
l/4th, height
whichever is
higher.
3 m. or
l/4th,
height
whichever
is higher.
3 m. or
l/4th,
height
whichever
is higher.
10. Open Spare
Reservation
OSR).
It shall be followed as per Schedule-I.
11. Parking space. As mentioned in Schedule-II will be followed.
Explanations.--
(1) Additional FSI of 20% will be permissible for stilt parking.
(2) All those buildings which are otherwise classified into public and
semi-public category qualifying for the definition of "commerce" in
section 2(10) and used for "commercial use" as defined in section
2(11) of the Act, shall be eligible for FSI permissible for commercial
use. This shall be decided by the technical committee of the
Directorate on case-to-case basis.
(3) For public buildings such as theatres, kalyana mandapams,
assembly halls, exhibition halls, hospitals, nursing homes, hotels,
lodging houses, etc. set back all around shall not be less than 6
metres.
(4) The reservation of land for community recreational purposes
such as parks or play ground required in these regulations shall be
as given in Schedule-I.
(5) Information Technology buildings shall comply with all the
provisions mentioned in Schedule-VII.
1(6) Solar Photo Voltaic system shall be mandatory and shall be
provided as prescribed in Schedule IX.]
https://www.manupatrafast.com/pers/viewdoctoc.aspx?sPath=Bare%20Acts%20and%20Rules/State/tamil%20nadu/Rules/tamil%20nadu/tamil%20nadu%20town%20and%20country%20planning%20act%201971/DeCoReErVeGuKaSaChTiLoPlAr/DeCoReErVeGuKaSaChTiLoPlAr.htm&col=8Vmp9ozFMb/2ISz1SdixCIRVngsjs/j1lxFukHhUlVjtLjdB0bd4mmFTJWUx/aBSKBdGFQIME6VoesAFaCGBewHrWR8ddcNQuL7JwN7hYU7qHizMrFQj4LFUvb7Bkchar(43)6o706GyNkh4BCUcuVcjmbGhejF08ykNubEvKW4zqo890cktJ88vxBo32cc1YJmu9Dc/5IUlIm3BdNjSABchar(43)2R9TRHZChuWg9X1a6Zdqtl8E2/Y=#F1
2(7) Special Regulations for Hospitals buildings shall be adhered to
as given in Schedule-XIL]
Previous and next
Questions people ask
Is regulation 3 of Development Control Regulations for Erode/Veuore/Tiruveuore/Coimbatore/Madurai/Gummudipoondi/Kancheepuram/Salem/Chengalpattu/Tiruppur/Tiruchirappalli Local Planning Area still in force?
No repeal of Development Control Regulations for Erode/Veuore/Tiruveuore/Coimbatore/Madurai/Gummudipoondi/Kancheepuram/Salem/Chengalpattu/Tiruppur/Tiruchirappalli Local Planning Area is recorded.