Rule 2, Tripura Fire Safety Rules 2026: DEFINITIONS

Tripura Fire Safety Rules 2026 - Rule 2

Text of rule 2

DEFINITIONS

2. DEFINITIONS:- In these rules, unless the context otherwise requires: (1) “Act” means the Tripura Fire and Emergency Services Act,2022; (2) “authorized fire officer” means a Fire Officer of Tripura Fire and Emergency Services Department who is authorized by a special or general order to conduct fire inspection in a building or premise or issue a permission to erect a pandal or seal the pandal; (3) “area”, in relation to a building, means the superficies of a horizontal section thereof made at the plinth level, inclusive of the external walls and such portion of the party walls as belongs to the building; (4) “Assisted Evacuation” means strategy that exists during which designated persons provide assistance, during an emergency, to another person to leave a building or a specific part of the built environment and to reach a final place of safety. (5) “Atrium” means a large-volume space created by a floor opening or series of floor openings connecting two or more stories that is covered at the top of the series of openings and is used for purposes other than an enclosed stairway; lifts hoist-way; an escalator opening; or as a utility shaft used for plumbing, electrical, air conditioning, or communications facilities. (6) “Authorities Concerned” an organization, office, or individual responsible for enforcing the requirements of a notification or standard, or for approving or accepting equipment, materials, an installation, or a procedure. (7) “Automatic Fire Detection and Alarm System” A system comprising components and sub-systems required for automatically detecting smoke, heat or fire initiating an alarm and other actions as appropriate. This system also includes manually operated electronic fire alarm (MOEFA) system. MOEFA system (with or without automatic fire detection and alarm system) includes all or some of the components such as manual call stations (initiating an alarm for fire and other actions as required), talk- back system and public address system. (8) “Building” means any structure for whatsoever purpose and of whatsoever materials constructed and every part thereof whether used as human habitation or not and includes foundation, plinth, walls, floors, roofs, chimneys, plumbing and building services, fixed platforms, Veranda, balcony, cornice or projection, part of a building or anything affixed thereto or any wall enclosing or intended to enclose any land or space and signs and outdoor display structures. Tents, Shamianahs, tarpaulin shelters, etc, Tripura Fire Safety Rules, 2026 Page 2 of 169 erected for temporary and ceremonial occasions with the permission of the Authority shall not be considered as building. (9) “Building Height” means the vertical distance measured in the case of flat roofs, from the average level of the ground around and contiguous to the building or as decided by the Authority to the terrace of the last livable floor of the building adjacent to the external wall; and in the case of pitched roofs, up to the point where the external surface of the outer wall intersects the finished surface of the sloping roof; and in the case of gables facing the road, the mid-point between the eaves level and the ridge. Where the building is located in a sloped terrain, height shall be determined from the lowest level (that is approachable by the fire service vehicles) to the terrace level. Architectural features serving no other function except that of decoration shall be excluded for the purpose of measuring heights. (10) “Basement” means the lower storey of a building partly or wholly below the ground level or the abutting road level, whichever is higher; (11) “competent authority” means the Director, Tripura Fire and Emergency Services, or any officer as may be authorized by the State Government, by issuing notification. (12) “Combustible Material” means a material which either burns itself or adds heat to a fire, when tested for non-combustibility in accordance with the list of standards as specified in Schedule V(1). (13) “Common Path of Travel” means the portion of the exit access which the occupants are required to traverse before two (or more) separate and distinct routes or two (or more) exits become available. Common paths of travel are part of travel distance. (14) “Covered Area” means a area covered by the building immediately above the plinth level. The area covered by the following in the open spaces is excluded from covered area (see Table 9) of Schedule I: (i) Garden, rockery, well and well structures, plant nursery, water pool, swimming pool (if uncovered), platform round a tree, tank, fountain, bench, Chabutara with open top and unenclosed on sides by walls and the like; (ii) Drainage culvert, conduit, catch-pit, gully pit, chamber, gutter and the like; (iii) Compound wall, gate, unstoreyed porch and portico, slide, swing, uncovered staircases, ramp areas covered by Chhajja and the like; and (iv) Watchman’s booth, pump house, garbage shaft, electric cabin or substations, and such other utility structures meant for the services of the building under consideration. Explanation: For the purpose of this Part, covered area equals the plot area minus the area due for open spaces in the plot. (15) “Down-comer” means an arrangement of firefighting within the building by means of down-comer pipe connected to terrace tank through terrace pump, gate valve and non-return valve and having mains not less than 100 mm internal diameter with landing valves on each floor/landing. It is also fitted with inlet connections at ground level for charging with water by pumping from fire service appliances and air release valve at roof level to release trapped air inside. (16) “Dry Riser” means an arrangement of firefighting within the building by means of vertical rising mains not less than 100 mm internal diameter with landing valves on each floor/landing which is normally dry but is capable of being charged with water usually by pumping from fire service appliances. (17) “Department” means Home (Fire & Emergency Services) Department, Government of Tripura; (18) “dwelling” means an independent unit with separate living, cooking and sanitary facilities; (19) “engineer” means a person having a degree in civil, electrical or fire engineering from a recognized university or institute; (20) “Emergency Lighting” means lighting provided for use when the supply to the normal lighting fails. (21) “Emergency Lighting System” means a complete but discrete emergency lighting installation also fed from the standby power source to the emergency lighting lamp(s), for example, self-contained emergency luminaries or a circuit from central battery (with or without monitoring system) connected through wiring to several escape lighting luminaries. Tripura Fire Safety Rules, 2026 Page 3 of 169 (22) “Escape Lighting” means that part of the emergency lighting which is provided to ensure that the escape route is illuminated at all material times, for example, at all times when persons are on the premises, or at times the main lighting is not available, either for the whole building or for the means of egress. (23) “Evacuation Lift” means lift that can be used, during an emergency, for self-evacuation. (24) “Exit” means that unobstructed component of means of egress which is between the exit access and the exit discharge or public way. Exit components include exterior exit doors at the level of exit discharge, interior exit stairways, exit passageways, exterior exit stairways and exterior exit ramps (see Fig. 1 of Schedule I). (25) “Exit Access” means that portion of a means of egress that leads to an exit (for example, doorways, staircase lobby, ramps, Veranda, corridor or passageway leading to an exit) (see Fig. 1 of Schedule I). (26) “Exit Access Corridor” means a corridor in exit access which may not necessarily have the requirement of exits being met. (27) “Exit Discharge” means the component of a means of egress between the termination of an exit and a public way (see Fig. 1 of Schedule I). (28) “floor” means unless otherwise specifically provided in these rules, the lower surface in a storey, after the finishing of which one normally walks in a building; (29) “Form” means a form appended to these rules; (30) “Fire Barrier (or Fire Resisting Barrier)” means a fire barrier is a vertically or horizontally aligned member such as a wall or a fire curtain, or a floor. These may be with discontinuities created by openings with a specified fire resistance rating, where such members are designed and constructed with a specified fire resistance rating to limit the spread of fire that also restricts the movement of smoke. (31) “Fire Compartment” means a space within a building that is enclosed by fire barrier or fire resistant walls on all sides, including the top and bottom. (32) “Fire Door and Fire Door Assembly” means any combination of fire door, frame, hardware and other accessories that together provide a specific fire resistant rating to the opening in terms of its stability, integrity and insulation properties, when installed in the openings in fire separation walls. Fire door is a component of fire door assembly. Explanation: (i) Wherever reference has been made to fire door or fire check door in this Rule, the same shall be construed as fire door assembly. (ii) Fire doors in exits shall have fire rating as required in this Rule to meet the requirement of integrity and stability; and the insulation criteria shall be 20 min. (iii) Fire doors in exits shall be provided with intumescent seal. (iv) Fire doors in exits shall not be allowed to be on hold open position and kept closed and to close by ‘door closure – spring mechanism’. (v) Fire curtains shall not be allowed as fire exits. If so provided for compartmentation, independent fire door shall be provided meeting the requirement for fire door in exits as above (of the width as required) within the prescribed travel distance requirement. (33) “Fire Exit” a way out leading from exit access with or without panic bar provided on the door. (34) “Firefighting Shaft (Fire Tower)” means an enclosed shaft having protected area of 120 min fire resistance rating comprising protected lobby, staircase and fireman’s lift, connected directly to exit discharge or through exit passageway with 120 min fire resistant wall at the level of exit discharge to exit discharge. These shall also serve the purpose of exit requirement/strategy for the occupants. The respective floors shall be approachable from fire-fighting shaft enabling the fire fighters to access the floor and also enabling the fire fighters to assist in evacuation through fireman’s lift. The firefighting shaft shall be equipped with 120 min fire doors. The firefighting shaft shall be equipped with firemen talk back, wet riser and landing valve in its lobby, to fight fire by fire fighters (see Fig. 2 for a typical firefighting shaft). Tripura Fire Safety Rules, 2026 Page 4 of 169 (35) “Fire Load” means calorific energy, of the whole contents contained in a space, including the facings of the walls, partitions, floors and ceilings. (36) “Fire Load Density” means fire load divided by floor area. (37) “Fireman’s Lift” means a lift or a group of lifts invariably associated with all the features and requirements of a fire-fighting shaft. Such lift(s) are installed to enable fire services personnel to reach different floors with minimum delay, and shall meet the additional features as required in accordance with this Rule. This lift also serves the purpose of meeting the requirement of evacuation lift for assisted evacuation. (38) “Fire Resistance” means fire resistance is a property of an element of building construction and is the measure of its ability to satisfy for a stated period, some or all of the following criteria: (i) “Load bearing capacity (Stability) (R)” means the ability of a load bearing element to withstand fire exposure without any loss of structural stability. (ii) “Integrity (E)” means resistance to penetration of flame and hot gases. (iii) “Insulation (I)” means resistance to temperature rise on the unexposed face up to a maximum of 180°C at any single point and average temperature of 140°C. (39) “Fire Resistance Rating” means the time that a material or construction will withstand the standard fire exposure as determined by fire test done in accordance with the standard methods of fire tests of materials/structures in accordance with the list of standards as specified in Schedule V (2)]. Explanation: (i) The requirement of rating of various building elements as given in this Rule shall be applicable in accordance with the provisions given in accordance with the list of standards as specified in Schedule V (2)]. (ii) The fire resistance rating shall be specified in terms of minutes. (iii) Fire resistance rating for non-structural material/assembly shall bear a label of compliance to such rating as per the approval of competent authority based on testing and evaluation. The label shall be permanently affixed to the material/assembly and may carry other relevant details such as name and type of the product, and manufacturer’s details. (40) “Fire Resistant Wall” means fire resistance rated wall, having opening(s) with specified fire resistant rating, which restricts the spread of fire from one part of a building to another part of the same building. (41) “Fire Separation” means the distance in metre, measured from the external wall of the building concerned to the external wall of any other building on the site, or from other site, or from the opposite side of street or other public space for the purpose of preventing the spread of fire. (42) “Fire Stop” means a fire resistant material, or construction, having a fire resistance rating of not less than the fire separating elements, installed in concealed spaces or between structural elements of a building to prevent the spread/propagation of fire and smoke through walls, ceilings and the like as per the laid down criteria. Explanation: (i) Fire stop assembly for through penetrations is a combination of firestop compatible for use with the penetrant, penetration items such as cables, cable tray, conduits, ducts, pipes, etc, and their means of support through the wall or opening that together restores the fire resistance rating of the fire separating elements in terms of its integrity and/or insulation properties. (ii) Fire stop assembly for joints is the one where fire stop with movement capability is used to seal the linear joints between adjacent fire separating elements, to maintain the fire resistance of the separating elements, which should be installed within its tested design limits with regard to size of the joint, type of assembly, and anticipated compression and extension of the joint. (43) “Fire Suppression Systems” means (i) “Gas based systems” means systems that use gaseous agents as fire suppression media, such as, all agents alternate to Halon gases, listed and approved for use by relevant Indian Standards; other methods/types of gas based systems where their protection is equal to or better than what is Tripura Fire Safety Rules, 2026 Page 5 of 169 suggested above for the type of application subject to the acceptance of Authorities concerned may also fall under such systems. (ii) “Water based systems” means systems that use mainly water as firefighting media such as hydrant system, sprinkler system, water spray system, foam system and water mist system. (44) “Fire Wall or Fire Separating Wall” means a fire resistance rated wall having fire protected openings, which restricts the spread of fire and extends continuously from the foundation to the roof (and through the roof at least 1m above the roof in case of combustible roof), with sufficient structural stability under fire conditions to allow collapse of construction on one side or either side without collapse of the wall. (45) “Floor Area (Gross)” means the area of the floor within the inside perimeter of the outside walls of the floor of the building under consideration with no deductions for corridors and passage-ways, stairs, closets, thickness of interior walls, columns, lifts and building shafts or other features. (46) “Floor Area Ratio (FAR)” means the quotient obtained by dividing the total covered area (plinth area) on all floors by the area of the plot: Total covered area of all floors FAR--------------------------------------------- Plot area (47) “Fire Exit Hardware” means a door-latching assembly incorporating an actuating member or panic bar that releases the latch bolt upon the application of a force in the direction of egress travel, provided on exits. (48) ”good practices” means the list of standards as specified in Schedule V. (49) “High Rise Building” means a building 24 m or above in height, irrespective of its occupancy. (50) “Horizontal Exit” means a defend in place or a staging arrangement, providing safety from fire and smoke originating from the area of incidence, by allowing alternative egress from a compartment to an area of refuge or another compartment at or near the same level. This also includes such egress from a compartment to an adjoining building. A horizontal exit shall be through a fire door of 120 min rating in a fire resistant wall. Horizontal exit require separation with the refuge area or adjoining compartment through 120 min fire barrier. The adjoining compartment of the horizontal exit should allow unlocked and ease of egress and exits for the occupants using defend in place strategy. (51) “Lift Lobby” means a space from which people directly enter a lift car(s) and into which people directly enter upon exiting a lift car(s). (52) “Means of Egress” means a continuous way of travel from any point in a building or structure to a public way, consisting of three separate and distinct parts, that is, exit access, exit and exit discharge. (53) “Means of Escape” means a way out of a building or structure that does not conform to the strict definition of ‘means of egress’ but does provide an alternate way out. (54) “Mixed Occupancy” means a multiple occupancy where the occupancies are intermingled. (55) “Multiple Occupancy” means a building or structure in which two or more classes of occupancy exist. (56) “Occupancy or Use Group” means the principal occupancy for which a building or a part of a building is used or intended to be used; for the purpose of classification of a building according to the occupancy, an occupancy shall be deemed to include subsidiary occupancies which are contingent upon it. (57) “Occupant Load” means maximum number of persons that might occupy a building or portion thereof at any one time. (58) “Place of Comparative Safety” means places within a building where people can stay little longer until evacuation, for example, refuge areas, terrace, fire/smoke separated compartments, etc. (59) “Pressurization” means the establishment of a pressure difference across a barrier to protect exit, stairway, lobby, exit passageway or room of a building from smoke penetration. (60) “Pressurization Level” means the pressure difference between the pressurized space and the adjoining area served by the pressurized space expressed in Pascal (Pa). Tripura Fire Safety Rules, 2026 Page 6 of 169 (61) “Public Way” means a street, alley, or other similar parcel of land essentially open to the outside air, dedicated, or otherwise permanently appropriated to the public for public use and having a clear width and height of not less than 3 m. (62) “Ramp” means the construction, in the form of an inclined plane that is steeper than or equal to 1 : 20 (5 percent) from the horizontal, together with any intermediate landing, that makes it possible to pass from one level to another. (63) “Refuge Area” means an area within the building for a temporary use during egress. It generally serves as a staging area which is protected from the effect of fire and smoke. (64) “Roof Exits” means a means of escape on to the roof of a building, where the roof has access to it from the ground through alternative stair case or adjacent building. (65) “Site (Plot)” means a parcel (piece) of land enclosed by definite boundaries. (66) “Smoke Barrier” means a continuous membrane, or a membrane, where such membrane is designed and constructed to restrict the movement of smoke. (67) “Smoke Compartment” means a space within a building enclosed by smoke barriers on all sides. (68) “Stack Pressure” means pressure difference caused by a temperature difference creating an air movement within a duct, chimney or enclosure. (69) “standards” means standards contained in Schedule V. (70) “Travel Distance” means the distance to be travelled from any point in a building to a protected exit or external escape route or final exit measured along the line of travel. (71) “Ventilation” means supply of outside air into, or the removal of inside air from an enclosed space. (72) “Venting Fire” means the process of facilitating heat and smoke to leave a building as quickly as possible by such paths so that lateral spread of fire and heat is checked, firefighting operations are facilitated and minimum fire damage is caused. (73) “Visual Strobes/Flashing” means it is an audio-visual fire alarm for alerting persons with hearing impairment with flashing light. The strobe frequency should be from 0.5 Hz to 4.0 Hz. Explanation — Care should be taken to ensure that overlapping strobes do not combine to result in a higher frequency of flashing. (74) “Volume to Plot Area Ratio (VPR)” means the ratio of volume of building measured in cubic metre to the area of the plot measured in square metre and expressed in metre. (75) “Water Based Systems” means (i) “Hydrant System” means a distribution system having a network of piping installed underground/above-ground around and/or through inside of a building with internal and/or external hydrants fitted with landing valves at regular intervals according to the occupancy. The distribution system is connected to water supply system for firefighting. (ii) “Automatic Sprinkler System” means a system of water pipes fitted with sprinkler heads at suitable intervals and heights and designed to actuate automatically, control and extinguish a fire by the discharge of water. (iii) “Automatic Water Spray Systems” means a special fixed pipe system connected to a reliable source of fire protection water supply and equipped with water spray nozzles for specific water discharge and distribution over the surface or area to be protected. The piping system is connected to the water supply through an automatically actuated deluge valve which initiates flow of water. Automatic actuation is achieved by operation of automatic detecting equipment installed along with water spray nozzles. There are two types of systems namely high velocity and medium velocity systems. (iv) “Water Mist Systems” means a distribution system connected to a pumping and water supply system that is equipped with nozzles capable of delivering water mist to the part/entire enclosure or area, intended to control, suppress, or extinguish fire and is capable of meeting the specified performance requirements. (v) “Foam Protection System” means firefighting systems where foam is made by mechanically mixing air with a solution consisting of fresh water to which a foaming agent (liquid concentrate) has been Tripura Fire Safety Rules, 2026 Page 7 of 169 added. Firefighting foam is a stable aggregation of small bubbles of density lower than oil or water, and shows tenacious qualities for covering horizontal surfaces. There are three types of foam applications that is, low, medium and high expansion foams depending upon the application. (76) “Wet Riser” means an arrangement for firefighting within the building by means of vertical rising mains not less than 100 mm nominal diameter with landing valves on each floor/landing for firefighting purposes and permanently charged with water from a pressurized supply.

Previous and next

All provisions of Tripura Fire Safety Rules 2026

Questions people ask

Is rule 2 of Tripura Fire Safety Rules 2026 still in force?

No repeal of Tripura Fire Safety Rules 2026 is recorded.