Regulation 110, Central Electricity Authority (Measures relating to Safety and Electric Supply) Regulations, 2023.: Portable and transportable machines
Central Electricity Authority (Measures relating to Safety and Electric Supply) Regulations, 2023. - Regulation 110
Text of regulation 110
Portable and transportable machines
110. Portable and transportable machines. – The person designated to operate an electrically driven coal-cutter, or
other portable or transportable machine, shall not leave the machine while it is in operation and shall, before
leaving the area in which such machine is operating, ensure that the supply is disconnected from the flexible
cable which supplies electricity to the machine and when any such machine is in operation, steps shall be taken
to ensure that the flexible cable is not dragged along by the machine:
Provided that all portable and transportable machines used in underground mines shall operate on
remote control from the concerned switchgear with pilot core protection:
Provided further that the portable and transportable machines used in open cast mines shall have the
provision such that the power supply to the machine from concerned switchgear is remotely controlled from the
machine:
Provided also that the portable or transportable machines used in open cast mine, provision of tripping
device or switch device from the operator‟s cabin shall be provided to disconnect power supply to such machine
from the field switchgear.