Rule 24, The West Bengal Lift, Escalator And Travelator Rules, 2022: Liftwells
The West Bengal Lift, Escalator And Travelator Rules, 2022 - Rule 24
Text of rule 24
Liftwells
24. Liftwells. -(1) Every Lift well intended for the installation ofthe Lift or any equipment necessary for its maintenance
shall be exclusively reserved for that purpose and shall not be used for any other purpose;
(2) The inner sides ofa Lift well shall, so far as practicable, form a smooth, continuous flush surface devoid of
projections or recesses. Where any projections extending inwards from the general surface ofthe enclosure
at or near openings or landing cannot be rendered flush, then they shall be leveled on the underside to an angle
ofnot less than 60 degree from the horizontal by means ofmetal plates, cement rendering, or other suitable
fire resisting materials.
(3) Where there is more than one Lift in common well, a width ofminimum allowance of 100 millimeters for
separator beam shall be made.
(4) Where there is more than one Lift in common well, a suitable separator screen throughout the whole height
ofLift well having adequate strength shall be fixed in the Lift well to protect the person working in the Lift
well or in the Lift car, from accidental contact with counter weights and other Lift car at any state of their
travel.
(5) No room, passage or thorough fare shall be provided under any Lift well except in case of the Lift having
counter weight fitted with over speed governor safety device.
(6) Where a Lift car leveling device is operative with the Lift car gate opening such interior surfaces shall always
form a smooth flush surface below each landing level for a depth to at least the depth ofthe car leveling zone
plus distance through which the Lift car may travel of its own momentum when power is cut off.
(7) Sufficient space shall be provided between the guides for the car and the side walls ofthe Lift well enclosure
to allow safe and easy access to the parts of the safety gear for their maintenance and repairs.
e
14 TIIEKOLKATAGAZETIE,EXTRAORDlNARY, NOVEMBER 11, 2022 [PARrI
(8) Every Lift well, together with the whole ofthe equipment and apparatus contained therein, shall be rendered
fire resisting to the greatest possible extent.
(9) A notice with the word "Lift" shall be placed on the outside of each landing door.
(10) (10) The Lift well shall conform to specifications laid down by Bureau of Indian Standards specification
BIS-14665 (Part-1)-2000.
Previous and next
All provisions of The West Bengal Lift, Escalator And Travelator Rules, 2022
Questions people ask
Is rule 24 of the West Bengal Lift, Escalator And Travelator Rules, 2022 still in force?
No repeal of the West Bengal Lift, Escalator And Travelator Rules, 2022 is recorded.