LawGrids logoLAWGRIDS.ORG

Form VI, The West Bengal Lift, Escalator And Travelator Rules, 2022: FORMVI

The West Bengal Lift, Escalator And Travelator Rules, 2022 - Form VI

Text of form VI

FORMVI

FORMVI [See Rule 4(2) & Rule 21] GENERALCHECKLISTFORLIFTINSTALLATIONS (JOBNO.) [PARrI SI. Description Yes No Remarks No. 1 Whether permanent supply upto the dedicated Main Switch MCCB for Lift is available 2 Whether separate & dedicated single phase main switch'MCCB has been provided for Lift shaft light 3 Whether Lift main switch provided at nearest convenient location in Lift loby 4 Whether the Lift Main Switches at Ground Floor have been earthed with 8 SWG G.I wire at two distinct points 5 Whether main switch earthings are done to the building earth bar 6 Whether building earth bar is connected with minimum two earth pits and those are proper and marked as earth pits 7 Whether earth resistance at building earth bar measured & is within acceptable limit 8 Whether proper marking on Lift main switch done 9 Whether civil jobs at each flow Lift landing positions completed 10 Whether each landing has a proper Lift lobby with Fire exit 11 Whether staircase hand rail guard at each floor provided 12 Whether staircase hand rail for machine room provided 13 Whether pit is cleaned and waterproof 14 Whether pit stop switches are available 15 Whether Pit light is working 16 Whether pit ladder is provided 17 Whether Shaft lights are working 18 Whether limit switches earthing done 19 Whether buffer foundations are properly done with R.C.C 20 Whether Lift lobby lights are provided at each floor 21 Whether counter-weight clamping or tie split pins provided 22 Whether counter guard net provided upto required height 23 Whether TOE-guard ofminimum 750 mm provided 24 Whether proper pit depth maintained as per IS 14665 25 Whether proper counter-weight run-by maintained as per IS 14665 26 Whether proper bottom clearance maintained as per IS 14665 27 Whether landing gate seal sap checked & found ok PARrI] THEKOLKATAGAZETTE,EXTRAORDINARY, NOVEMBER 11, 2022 43 SI. Description Yes No Remarks No. 28 Whether Facia for automatic door provided 29 Whether finishing done below the landing door seal for manual door 30 Whether car lights are kept direct 31 Whether alarm bell checked and found ok 32 Whether all LEDs of floor indicator etc are working 33 Whether all lights, fan inside car are working 34 Whether gate locks at each flow checked & found ok 35 Whether proper top clearance maintained as per IS 14665 36 Whether machine room door is outside opening and made ofFire Proof weather proof as per IS 14665 37 Whether metal 415 V danger plate outside machine room door provided 38 Cheeked for any water ingress source to machine room through window, exhaust etc 39 Machine room main switch properly earthed at two distinct points with 8 swg G.I 40 Whether proper light & ventilation in machine room provided 41 All earthing wires, controller wiring etc are properly dressed 42 Lift machine properly installed &fastner bolt provided 43 Whether rope end are property seated 44 All limit switched (up-down final, governor safety) installed at requisite location 45 Whether Governor name plate with tripping speed fixed on governor body 46 Whether extra cut-out on machine room floor has been properly covered 47 Whether UP & Down final limit checked & found ok 48 Governor safety (both electrical & mechanical) checked and found ok 49 Whether load balancing checked & found in order 50 Load test (if done on the hook at machine room) has been tagged 51 Whether governor switch and car safety switch or both the switches aremanually operable 52 Whether Governor actuation facility from control panel provided for MRL Lift 53 WhetherManual Rescue Device provided forMRL Lift 54 Whether controller maintenance access panel besides top floor landing forMRLLift 55 Whether separate brake contactor provided in case ofMetal metal contact 56 Whether clear laminated safety glass used & certificate available in case ofglass Lift/shaft 57 Whether dynamic brake incorporated in case of drive 58 Whether cover for the dynamic resistance provided in case of installation outsidepanel 59. Whether Stop Switch provided in Car and found working 44 THE KOLKATAGAZETTE,EXTRAORDINARY, NOVEMBER 11, 2022 [PARrI

Previous and next

All provisions of The West Bengal Lift, Escalator And Travelator Rules, 2022

Questions people ask

Is form VI of the West Bengal Lift, Escalator And Travelator Rules, 2022 still in force?

No repeal of the West Bengal Lift, Escalator And Travelator Rules, 2022 is recorded.