Rule 833, Haryana Prisons Rules 2022: New construction of main gate and blocks near to the main gate shall ordinarily be based on the following norms, namely
Haryana Prisons Rules 2022 - Rule 833
Text of rule 833
New construction of main gate and blocks near to the main gate shall ordinarily be based on the following norms, namely
833. New construction of main gate and blocks near to the main gate shall ordinarily be based on
the following norms, namely: –
(a) dimension of main gate shall be at least fourteen feet in width and sixteen feet in height
so that a fire tender, concrete mixer truck vehicle or a borewell rig shall pass through
it. The main gate shall be a double gate arrangement made up of a strong steel frame
having vertical round or square steel bars of twenty-five mm diameter or thickness.
Space between two gates will not be less than sixty feet in length and fifty feet in width
and eighteen feet in height to facilitate gate operations. Each gate shall have a wicket-
gate of at least three feet in width and seven feet in height. The main gate and the
wicket-gates shall have strong locking arrangements from inside. Both gates shall have
arrangements for easy opening and closing of shutters. The gates shall be covered with
iron sheet from outside up to the height of ten feet. The wicket-gates shall have
peepholes covered with lead at eye level;
(b) there shall be a properly designed administrative block for each category of prison
adjacent to the main gate and shall have office rooms, record rooms, store room,
conference hall, common rooms and control rooms for efficient functioning of the
administration. Adjacent to the administrative block shall be the interview room and
visitor’s hall with cloak-room and toilet with a separate entrance to the hall from
outside;
HARYANA GOVT. GAZ. (EXTRA.), DEC. 30, 2022 (PAUS. 9, 1944 SAKA) 1395
(c) there shall be a reception ward, near the main gate which shall have necessary
facilities for proper implementation of admission-quarantine-orientation-classification
programme. It shall have separate barracks for under trial prisoners and convicts, few
individual cells, open working shed, and an office;
(d) The main gate shall be suitably painted with colours.
Central control
room.
834. A central control room with sufficient infrastructure to conduct daily prison routine and to
control movement of prisoners in a proper and disciplined manner shall be constructed in every
prison. A central watch tower shall also be constructed in each prison for surveillance of all prison
premises.
Norms for
construction of
new wards and
cells.
Previous and next
Questions people ask
Is rule 833 of Haryana Prisons Rules 2022 still in force?
No repeal of Haryana Prisons Rules 2022 is recorded.