Rule 821, Haryana Prisons Rules 2022: The construction of all new prison buildings shall ordinarily be based on the following norms namely

Haryana Prisons Rules 2022 - Rule 821

Text of rule 821

The construction of all new prison buildings shall ordinarily be based on the following norms namely

821. The construction of all new prison buildings shall ordinarily be based on the following norms namely:– (a) no building, other than the prison, shall be constructed within hundred meters of the prison wall of a Central prison and within seventy five meters of the prison wall of a District and sub prison. Prison premises shall be demarcated as ‘Out of Bound Area’ as a sterile zone and the right of entry in the prison premises shall be reserved with the Superintendent; (b) area enclosed within the four walls of a prison shall not be less than eighty-five square meters per head of total capacity. Where land is scarce, like in big cities, the minimum area shall be sixty square meters per prisoner; (c) prison shall have perimeter walls. The height of the perimeter wall shall be twenty-one feet. The height of the wall of the female’s section inside the prison shall be eighteen feet. The other internal walls shall be minimum ten feet in height; (d) no building inside a prison shall be nearer than hundred feet to the outer perimeter wall; (e) barracks shall have a permanent structure capable of protection of the personnel in case of any hostile situations. There shall be provisions for necessary lighting and fan arrangements with a power back up from the stand-by generator/invertor inside the prison. There shall also be provision for a sanitary type toilet with flushing arrangements and cubicle type bathrooms within the barracks; (f) energy efficient lighting source shall be used inside the prison building. Renewable energy dependent lighting may be considered for the purpose of street lighting; (g) right from the designing phase of construction, ‘Green Building’ concept shall be considered to ensure an environmentally responsible and resource-efficient prison premises; (h) all prison buildings shall have rain water harvesting system and sewerage treatment plant; (i) all constructions shall adhere to BIS standards; (j) it shall be ensured that there is no structural defect in the exclosure wall grantings or in any other part of the building which can be source of support to any convict who intends to escape. NOTE. - CCTV cameras shall be installed in every prison at all sensitive and vulnerable points including living areas of the prisoners, except in bathrooms/toilets and living areas in female enclosure. Outer periphery wall. 822. (1) The prison premises shall be a closed area. An outer wall at least six feet in height and further having two feet six inches concertina wire on top of it shall be constructed around the prison premises. Watch towers at four corners may also be constructed for security and observation purposes. There shall be single point entry to the prison premises with sentry post and proper barricading. (2) As far as feasible, an outer wall at least eight feet in height shall be constructed around the residential complex of staff members. There shall be a single point entry to the residential complex with a manned gate. HARYANA GOVT. GAZ. (EXTRA.), DEC. 30, 2022 (PAUS. 9, 1944 SAKA) 1393 Walls of prisons. 823. (1) The outer walls of every prison shall be rounded on top: cornices, projections of any sort or broken glass, which shall not afford a hold for a blanket or cloth. At every junction of a partition wall with the outer wall and at every angle in the outer wall, a sufficient addition shall be made to the height to prevent the possibility of any prisoner scaling the wall at these places. The main enclosure wall of a prison shall ordinarily not be less than twenty feet high and a clear space of hundred feet shall be left between it and any building on either side of it. (2) A second wall of similar architecture and minimum eighteen feet of height shall be constructed at every prison. The distance between these walls shall not be less than thirty feet. (3) A suitable road shall be constructed along these walls on both sides to enable easy patrolling. Construction of residential complex for staff members. 824. In every prison a residential complex for staff members shall be constructed. The houses/hostel shall be constructed as per policy of the Government/Department. A Community Centre-cum- Gazetted Officers Mess, Warder Hostel-cum- Non Gazetted Officers Mess and Health and Wellness Centre shall be constructed at every prison. Watch Tower. 825. (1) At least six watch towers shall be constructed in every Central and District Prisons. Provided that the distance between two watch towers shall not be greater than hundred meters. (2) Watch towers shall be in circular with minimum radius of eight feet. (3) As far as feasible, watch tower shall have circular cemented staircase. (4) As far as feasible, the distance between outer wall and centre of watch tower shall be thirteen feet. (5) Toilet and washbasin shall be provided in each watch tower. (6) Mesh grill shall be installed in every watch tower. Capacity of wards and cells. 826. (1) The accommodation capacity of wards, cells and other compartments intended for occupation by prisoners shall ordinarily be regulated by the scale of superficial and cubical space and lateral ventilation in respect of each prisoner shall be as shown in the following table, - SLEEPING BARRACKS CELLS HOSPITALS Square meters of ground areas Cubic meters of air space Square meters of lateral ventilation Square meters of ground areas Cubic meters of air space Square meters of lateral ventilation Square meters of ground area Cubic meters of air space 3.71 15.83 1.12 8. 92 33. 98 2.23 5.58 23.75 (2) The doors and windows shall be provided to the barracks, cells and hospitals in prisons to protect the prisoners from rain and cold. The shutters shall be fixed outside the iron gratings. (3) Arrangements for double locks are required for security cells but single lock is all that is required for other cells. Combined locking arrangements for cells are unnecessary. (4) Each prison shall have a proper interview room of suitable size according to the total capacity of the institution and the average number of visitors coming every day for interviews with the prisoners. Transparent toughened glass with intercom facility for visitors who have interview with prisoners shall be preferred. 1394 HARYANA GOVT. GAZ. (EXTRA.), DEC. 30, 2022 (PAUS. 9, 1944 SAKA) (5) In each prison, a waiting room with facilities like toilet, drinking water supply, seating arrangements etc. shall be constructed along with an enquiry office outside the main gate but not too close to it for the convenience of people coming for interviews and other purposes. (6) A control room under the supervision of the Superintendent shall be established in or near the main gate in each prison. It shall function as the nerve center for the entire prison. (7) Each prison shall have video conferencing rooms with adequate infrastructure and connectivity for trial of prisoners. Verandas. 827. All barracks and cells shall, if feasible, be provided with verandas not less than two meters in width. Ventilation of wards and cells. 828. There shall be ceiling ventilation that is opening at intervals close to the junction of wall and ceiling. The minimum height of roofs or ceilings shall not be less than eleven feet from the floor. Certificate for fitness for occupation. 829. No newly constructed ward, cell or other compartment shall be occupied by any prisoner until the Medical Officer and the Superintendent have certified that such ward, cell or other compartment is, in all respect, fit to be so occupied. Capacity of wards to be inscribed over the door.

Previous and next

All provisions of Haryana Prisons Rules 2022

Questions people ask

Is rule 821 of Haryana Prisons Rules 2022 still in force?

No repeal of Haryana Prisons Rules 2022 is recorded.