Rule 8, THE RAJASTHAN PRISONS RULES, 2022: Norms of Prison Building
THE RAJASTHAN PRISONS RULES, 2022 - Rule 8
Text of rule 8
Norms of Prison Building
8. Norms of Prison Building.- (1) New Prison buildings a f t e r co m m en c em e n t
o f t h e s e r u l e s shall have to be constructed with the following norms and old prison
buildings shall as far as possible modified or renovate to fulfill the said norms,
namely:-
(a) the minimum dimension of the main gate and second gate of all the closed
prisons shall be three meters in width and four meters in height;
(b) dimension of main and rear gates shall be so wide that in case of fire
exigencies a fire tender, a bore well rig to dig bore well a lorry to transport
raw material or logs for factory and ration articles shall be able to pass
through these gates;
(c) the gate shall be made of a strong steel frame having vertical round or
square steel bars of twenty five millimeters diameter or thickness;
(d) each gate shall have a wicket gate of at least of 0.6 meters in width and 1.5
meters in height;
(e) the main gate and the wicket gates shall have strong locking arrangements
from inside and both gates shall have arrangements for easy opening and
closing of shutters;
(f) the gates shall be covered with iron sheet from outside up to the height of
two and half meters;
(g) the wicket gates shall have peepholes covered with lead at eye level;
(h) the main gate may be painted with colours identical to that of departmental
flag if prescribed by the Government;
(i) space between two gates shall not be less than twelve meters in length and
five meters in width to facilitate gate operations and it shall have the
following facilities; namely : —
(i) a cabin;
(ii) search room, and
(iii) space for security equipments;
भाग 4 (ग) राजस्ााू राज-पत्र दिसम् बर 12 2022 496
(j) entry to the prison shall only be through the main gate and all other entry
points, if existing, shall be closed permanently.
(2) There shall be a properly designed administrative block for each category of prison
and the said block shall be located adjacent to the main gate and shall have office rooms,
record rooms, conference hall, common rooms, enquiry cabins and control rooms,
interview rooms for male and female prisoners for efficient functioning of the
administration.
(3) So far as other units are concerned, the following norms are to be followed, namely:-
(a) a court room may also be constructed inside the Jail separately to dispose
of cases of under-trials involved in petty offences;
(b) the reception unit shall have necessary facilities for proper implementation
of admission-quarantine and orientation classification programmes and
physical facilities shall be set up in accordance with the number and type
of inmates to be received and the programme to be followed for proper
segregation of various types of inmates;
(c) for the purpose of housing, all accommodation provided for use of
prisoners, particularly for sleeping, shall meet basic requirements of
healthy living and due regard shall be paid to climatic conditions, cubic
contents of air, minimum floor space, lighting and ventilation.
(4) There shall be four types of living accommodations as mentioned below, namely:-
(a) barracks with accommodation for not more than eighty prisoners;
(b) single room accommodation for prisoners needing privacy for pursuing
studies, if possible;
(c) cells for segregation of prisoners for the purpose of security and
contagious diseases;
(d) provision for separate accommodation for transgender prisoners;
(e) the norms of prison building shall be applicable for construction of new
building/additional wards, as the case may be and if required, the existing
prison building shall be modified subject to budgetary provision;
(5)The minimum accommodation capacity of dormitories or barracks, cells and hospitals
per prisoner shall ordinarily be according to the following scale, namely:-
Sleeping Barracks Cells Hospitals
1 2 3
Sq. mtrs of
ground areas
Cu. mtrs of
air space
Sq. mtrs of
lateral
ventilation
Sq. mtrs
of
Ground
areas
Cu.
Mtrs of
air
space
Sq. mtrs of
lateral
ventilation
Sq. Mtrs
of ground
area
Cu. Mtrs
of air
space
3.71 15.83 1.12 8.92 33.98 2.23 5.58 23.75
(6) Over the door of every ward there shall be an inscription either in letters painted on
the wall or on a tablet of wood or metal, showing the class of prisoners for which it is
intended, the number of cubic and superficial feet it contains and the number of prisoners
which it is capable of accommodating.
(7) Temporary accommodation shall be provided for any prisoners in excess of this number
and care shall be taken to see that the Lock-up Register shows the accommodation available
in each ward, so as to enable the Superintendent to judge at a glance whether any particular
ward is overcrowded or not.
497 राजस्ााू राज-पत्र दिसम् बर 12 2022 भाग 4 (ग)
(8) The height of the main or perimeter wall shall be eighteen feet with electric wire fencing
and all corners shall be rounded.
(9) Partition walls around female wards shall be eleven feet high with concertina wire
fencing and in other cases it must be eight feet.
(10) No building shall be nearer than fifty meter from the main wall and in the case of double-
storied buildings, the distance from the main wall must be thirty meter.
(11) No inside building, latrine, shed, etc. shall be built against an outer wall and all such
buildings must be fifty feet away from the wall.
(12) An individual secure storage compartment sufficient in size to hold personal belongings
of the prisoners shall be provided to each prisoner.
(13) The barracks and cells shall be constructed on the following norms mentioned below,
namely:-
(a) if a barrack is flat-roofed, there shall be ceiling ventilation that is, opening
at intervals close to the junction of wall and ceiling 30 x 12.5 meters and
if the barrack is gable-roofed, there shall be a ridge ventilator having the
minimum height of roofs or ceilings not less than ten feet from the floor;
(b) the floor of the barrack shall be made of impermeable material such as
cement concrete;
(c) in prisons situated in cold regions or during cold seasons, appropriate
flooring should be provided to ensure habitable conditions in the barracks;
(d) all barracks shall, if possible, be provided with verandas not less than two
meters in width;
(e) though ventilation of the sleeping barracks is of the greatest importance,
prisoners shall not be permitted to close the windows and ventilation
openings with shutters or curtains at their discretion;
(f) in new barracks, the ventilating area per head will be half a window and
the standard grated window shall be 7 feet x 3 ½ feet, half a window will
mean 1 square meter;
(g) the ventilation shall, however, be controlled according to the season
wherever necessary or otherwise the barracks shall be too cold and damp
during winter and rainy season;
(h) the structural arrangements of fittings and fixtures and locking devices of
barracks shall be secure enough to prevent escapes and the existing
wooden frames of the doors, windows and ventilators if any shall be
replaced by iron or steel frames;
(i) the iron bars used in doors, windows and ventilators shall be of twenty
five millimeter diameter and the clear distance between two bars shall be
of seven and half centimeter;
(j) a barrack shall have only one door of 2.2’ x 1 meter and shall have a single
shutter;
(k) the door of the barrack shall have clear opening of 1 meter and the iron
frame be made of angle- iron of minimum of ten millimeter thickness
and should open in outer side of barrack;
(l) sufficient artificial light shall be provided to enable the prisoners to work
and read without difficulty in their barracks after dusk;
भाग 4 (ग) राजस्ााू राज-पत्र दिसम् बर 12 2022 498
(m) each barrack shall be provided with a first-aid kit which will be in the
custody of an authorized prisoner and the first-aid kits supplied to each
barrack should not have any sharp-edged items, long gauze rolls or tapes or
other such items;
(n) a looking mirror may be fixed outside each barrack for use of prisoners and
a wall clock may be fixed inside each barrack;
(o) adequate fire safety systems must be installed in the barracks or cells;
(p) the barrack shall be free from tobacco, smoke and excessive noise;
(q) each barrack or cell shall be provided with a flush toilet;
(r) there shall be thorough ventilation of every cell and at the back of the cell,
there may be a clerestory window;
(s) the floor of the cell shall be made of impermeable material;
(t) each cell shall have a yard attached to it where a prisoner can have the
benefit of sufficient air and light; and
(u) each cell shall be provided with a flush latrine and the existing cells shall
not be put into use till this facility is provided therein.