LawGrids logoLAWGRIDS.ORG

Rule 39, Bihar Fire Service Act Rule 2021: List of schedule

Bihar Fire Service Act Rule 2021 - Rule 39

Text of rule 39

List of schedule

39. List of schedule:- (i) Schedule - 'A"- Under section-4, 5 (a) and 12 of the Act, under rule-9 of the Rules, Duties and Responsibilities of Officers / Employees of various cadres of Fire Service. (ii) Schedule - "B'- Under section-4, 5(a) and 12 of the Act, under rule- 10 of the Rules, Standard Operating Procedure for Fire Station Officer & Operating Members. (iii) Schedule - "C"- Under section-2 (g), 20(1), 33/34/35/43 (2) (3)of the Act, under rule- 15(d) , 22(k) & 27(a) of the Rules, prescribed rate of fee for provisional No Objection Certificate,final No Objection Certificaterenewal ofNo Objection Certificate. AnnualFire Audit & Fire consultation. (iv) Schedule _0t1_ Under section-2 (g)of the Act, under rule- 16(e) of the Rules, Procedure of Online No Objection Certificate. (v) Schedule - "E'- Under section-25, 26 & 27 of the Act, under rule- 18(a) of the Rules, firc safety measures during construction of pandal & temporary structures (Indian Standard Burcau. iS. 8758-1993) & procedure of preparation of fire retardant pandal/ availability of materials. (vi) Schedule - "F'- Under scction-30of the Act, under rule- 20(g) of the Rules,prescribedrate of training fee for training of Fire Safety Officers in Fire Training Academy. (vii) Schedule - C"- Under section-32o1 the Act, under rule-21of the Rules. Ruhs / Application /Fee etc. for registration of fire consultant. (viii) Schedule - "H- Under section-33, 34,35 & 43 (l)(2)(3) of the Act, under rule-22(c) of the Rules, Advice regarding minimum fire safety measures in existing buildings. (ix) Schedule - "I"- Under section-22(l) of the Act, under rule- 28(a) of the Ru!es, Prescribed charges payable in case of deputation of members of Bihar Fire Service with necessary equipments out of State jurisdiction. (x) Schedule - "F'- Under rule- 32of the Rules, standbyduty charges on deputation of members of Bihar Fire Service with necessary equipments and instruments during any public ceremony, on request of any person or institution (xi) Schedule - "K'- Under section-3,4.5(a), 6 &9 of the Act, under rule- 04of the Rules, Organizational structure of Bihar Fire Service. FORM--A Appointment certificate (1 ndcr so h-sect I) olseelion ID of he Biliar Fire Ser\ cc Ac. 2014. under ride 06 of he I3iIiar Fite Service R ilcs.2C2 I). Office of the State Fire Officer-cum-flirector, Bihar, Patna Lefter number Dated It is certified that Shri Fathers Name Passport size Residence photo of the member, attested by the Assistant Director Whose photograph is located in the right part of the certificate, has been appointed on the post under the Bihar Fire Service Act, 2014 (Bihar Act 6,2014) and has been vested with powers, privileges and immunities of the member of Bihar Fire Service with the effect from the date The date of compulsory retirement of is (date) Name and signature oftlie member by whom attested Location: Patna Director Bhar Fire Service. FORM--B Application for Provisional No Objection Certificate (with enclosures) (UndcrscIion- 2(g) of Bihar I-Sire Scr'icc Ac'. 2014. Lllider rule-I5 (0(i) ofUiliar Fire ScriccRu(e. 2021) Ref no.- From, Date To, Sub:- Sir, The Director, State Fire Service, Bihar, Patna. For Provisional fire prevention and fire safety no objection certificate for building construction. lJWe am/are proposing for building construction which shall be started only after clearance from concerned Authorities. As per requirement of Bihar Fire Service Act. 2014. Bihar Fire Service Rules. 2021. Bihar Building Bylaws 2014 as amended from time to time, National Building code, 2016 as amended from time to time. I / we require fire prevention & fire safety no objection certificate, I / We swear to abide by all the provisions of fire prevention and Lire safety measures provided in all concerned Acts and Rules and follow the guidelines given as per local requirements. TI We request for Provisional Fire prevention and fire safely no objection certificate for proposed construction of building as per following details- I. Details of Plot marked for proposed building construction:- (a) Area (in sq. meter)- (b) Name of matiza/Ward No- (c )MS/CS/Plot No.- (d) Khata No/Sheet No- (e) Tauji No/Circle No.- (t) Thana No./Mohalla- 2. Name of concerned Police Station/District- 3. Name of concerned Fire Station- 4. Route details to approach on the proposed construction site- 5, Nearest source of water with distance (river/lake/pond/well/municipal water source/public- private water hydrants). 6. Designation and Address of Licensing Authority issuing building permit to whom NOC has to be sent- 7. Name and Address of Land Owner (property-owa/rented/leased) 8. Name and Address of Arch itect with contact No/fax/e-mail id etc.- 9. Name and Address of Builder with contact No./faxle-niail id etc.- Signature Enclosure with application A. Building Plan-- • Two Scts of building plan (Not less than 1200 scale) signed by a qualified Civil or Structural Engineer, an Architect and the Owner/Builder, showing abutting Street, dead end, occupancy of all parts! floors, air-conditioner and dampers, stair cases, corridors, lifts, ramps. 2, 2 sets of Site plan duly marked open places on all sides. 3. 2 sets of Floor wise plans including Basements! Stilts duly marked fire safety systems 4. 2 sets of Terrace plans 5. 2 sets of Section plans of two sides. 6. 2 sets of Elevation plans of two sides. 7. Two section drawings, through stairs (NBC-Part 2-12.2.5.l.b/e) 8. Bank draft of Fixed charges for NOC. B. Checklist - 9. Neatly typed check list without any corrections and interpolations. C. Undertakings- 10. Affidavit I1Jndertaking regarding followings- (a)Compliance of instructions as per provisional NOC. (b) Information regarding commencement of work, (e) Submission of periodical progress report. (d )Submission of completion certificate of construction in all respect. (e) Receiving of final NOC for taking occupancy certificate. (I) Maintenance of fire fightingequipments. (g )Training of slaff& occupants to carry out regular mock drill. (Ii) Calling for periodical fire audit, (i)Suhmission of estimates towards tile provision of fire safety systems and 15% of the estimate of Fire Safety System as Bank Guarantee. (j) Compliance of National Building Code of India. 2016 as amended from time to time, I3ihar Building Byelaws, 2014 as amended from time to time, Bihar Fire Service Act, 2014,Bihar Fire Service Rules. 2021. Bihar Municipality Act, 2007 and all applicable Building Laws! Rules! Regulations/Guidelines as per local situations. FORM--c CHECK LIST RELATED TO BUILDING PLAN (For provisional NOC/Final NOC) (Uiidersection- 2 (g) of Bihar Fire Service Act. 2014, underrule-15 (f)(i) ofBiliar Fire Service Rules. 202 Abbreviation-National Building Code of india, 2005 Part-4(NBC-p-4)INational Building Code of India, 2016 as amended from time to time Part-4(NBC-P-4)/Bihar Building Byelaws. 2014(131.) as amended from time to time, Provisions in National Building Code of India. 2016 as amended from time to time 'vi I prevail over National Building Code of India, 2005. which has been referred only for gudelines. Type of proposed building occupancy- Proposed! complete! NA. 2 Type of Sub- Occupancy- 3 Name of Proposed Building- 4 Height of proposed building from ground level Ref- NBC-P-4-3,4.4 Table-7 (in meters) Height of Construction in surroundings of proposed site (The minimum distance between two buildings will not be less than 1/3 of the height of the taller building or 3 meter whichever is Iower(BL-7). Direction Meters North South East West 6 Distance of building from Electric Lines (BL-3 I ) Vertical Meters Horizontal Meters 7 Covered area of proposed building Sq. meters Total built- up area ofall tloors including basements and stilts (in sq meters) sq. meter 8 A Number of floors- B Number of Basements- C Number ofStilts/Cround Floor 0 Number of Blocks- E Average Occupant load per floor F Floor Area in Sq. Meters. Classificat ion of occttpancv No. of Occupants as declared by the Builder No. ofOccupants based on Table of NBC i.e., floor area . . divided by occupant load Total Aggregate vidth ofslair case in Meters. (as declared bvthe Bull cler) Basement-I Basement-2 Stilt-I G Floor Stilt-2 Floor-I Floor-2 Floor-3 Floor-4 Otlle!s 9 Means of Access A Building abutting to road- Number of Roads.the p emLes is abutting.. B Abutting Street (Name and idth) Abutting Street Name- (The Abutting Road width should be minimum 12 ft/20 ft.—BL-33, 34. Abutting Street I (Width in meters) (nbc-p-3-4.6.a;4.8/ p-4-7.4. I .a) Abutting Street 2 (Width in meters) C Whether it is hard suriheed and motorable D Whether terminating in dead end (nbc-p-3 4.7;! p-3.4.6) 10 A Access /Open space and set back front Side Meters and other 3 sides of the Block: North (BL-3 5,36,3 7)(n bc-p-3 -4.6:4.2.4.6 South 8.2.3.1:84.1:9.4.1 .a'p-4- East 3,4.6:5.1.6:7.4.1) West Front side direction East/WestNorthiSo uth B Motorable access to and around building and turning radius at building Corners. (nbe-p-2-12.2.5. l.a / p3-4.6/7) C Approach to building. and6 metersaccess space on all sides shall be hard surfaced for movement of45 ton lire vehicles. This space of 6 meters for access shall be maintained free ofparking and kept free ofany obstructions, structures or Fixtures up to height of 4.5 meters above which 1.25 meters. Unenclosed balconies are allowed. D If water tank or bridge, has roofand it is in access route then the roofshould withstand a load o145 ton fire vehicle. (nbc-p-4-5. 1.6) F The open space around a building shall be in accordance with building height. It shall be kept in mind that maneuvering offire vehicle for fire fighting and rescue is ensured. F Minimum driveway for movement of fire tenders and aerial ladders around the building shall be available G The compulsory open spaces around he building shall not be used as parking space. I-f In order to ensure easy entry and exit of fire vehicles be minimum 4.5 meters width and 5 meters heigh requird height clearance (5 meters.) all along the driveway. needed for free movement oflarge fire tenders, and es,ecially he main entrance and exit gate shall . There shall be no obstruction of This is the minimum height the large aerial ladders. Carparldug :(nbc-p-2-12.2.51.g/p-3-lO/Appendix .B) Details Na of Cars Basement Stilt Ground floor 12 Projections into open space:- direction Meters Front Side I Side 2 Rear 3 Entrances/Exit-(nbc-p-3-4.6) L A Number of entry doors Number ofexit doors B Entrance Exit details — Entrance Ab Itt ng Road side width in Ui eters. Entrance I Entrance 2 ;Tead room clearance meters. 4. 14 STAIRCASES A No. of Internal staircase (M inimuni I) B No. of External staircase (Minimum I) Internal Staircase ( NBC-P-1-4.4.2.4.3.I 4.4.2.4.3.2/ 4.4.2 4.3.3) A No. anti wi diii ut interna] sta "cases No. of Location Widt Ii ui (nbc-p-4-4.9.6) Staircase From floor no. To tloo r no. Staircase Inmeters. 3 Others B Width of the Treads (nbc-p-4-4.9.7) cm C Height of the riser (nbc-p-4-4.9.S) cm D Number of riser (nbc-p-4-4.9.9) per flight E Height of the hand rails (Hand rails at 100cm height)(rbc-p-4-4.9.9) meter. F Gap between two vertica's... cm G Ucad room clearance .., meter. H Construction should be with non-combustibles materials (NBC- p-4-4.9.1) I There shall be a self contained unit along with at least one external wall and should be completely enclosed. (NBC p-4-4.9.2) J It shall not be around lift (NBC- p-4-4.9.3) K It shall be so designed that the number, of people in between floor landings. is not less than those on each floor. (NBC- p-4-4.9.1 0) in 01) L No electrical panels! AC ducts or gas pipes shall be allowed siaircase(NBC- p44.9.4!1 M Access to stairs shall be through two hours, rated fire! smoke door (NBC- p-4-4.9.IOb) N Travel distance I Distance from the farthest point ... . meter. 2 Distance from the turning dead-end of the corridor to the staircase meter. E,ternal staircase (NBC-P-4-4.4.2.4.4.4.3) A No. and width of staircase No. of Location Width of (nlinimum one) staircases From floc no. To floor no. staircase in meters. 2 Olhers B Width ofthe Treads cm C I leight ofthe riser cm U Number ofriser ... per flight E I Icight of the hand rails ... meter F ftc gap between two verticals... . em r 0 Head room clearance ,,, meter. i-I It shall terminate at Groundl Stilt floor only. It should not extend to the basement. It shall have emote and separate gate entrance from the internal staircase. I Pressurization N13C-P-4-4.2.5) ofstaircase ( The pressurization of staircases shall be adopted for high rise buildings and hui ding having mixed occupancy / multiplexes having covered area more than 500 nY, IS Exit Doorways: (NBC-P-4-4.2.4.l) Every exit cloonvay having width as per occupancy class requirements shall open into an enclosed stairway or a corridor or a horizontal exit for transit or providing continuous arid protected means of egress. 16 10) Ramps :(NBC-P-4-4.42.4,3,5) (NBC- p-4-4.I4/ p-3- A Number of Ramps- B Width Ramps Width of ramp in meters. Ramp I Ramp 2 C Steep should not be more than in 10 and in no case I in 8. Surface to be skid proof 17 Li t- NBC-P-8-7,l. to 7.2.4/ NBC-P-2-Annexure-E) (NBC- p-4-Annax-C-1 .5) A No. of passenger lift and capacity No. Capacity(kg) 2 Others B No. ofservice liftand capacity No. Capacity(kg) 2 Others C Lift motor room shall be located preferably on top of ti e shaft and separate from the shaft by the floor ofthe room, However, for M.R.L. Lifts, this is not applicable. D Landing doors in lift enclosures shall have a fire resistance of not less than I hour. E The number of lifts in one row for a lift hank shall not exceed 4 and the total number of lifts in the bank (of two rows) shall not exceed 8. A 'vail of 2 hour fire resistance shall separate individual shaft in a bank F Lift car door shall have a fire resistance rating of hal fan hour. 0 Collapsible gates shall not be permitted 'or lifts and shall have solid lift doors with fire resistance of at least I hour. If Ifthe lift shaft and lobby is in the main portion oithe building, a positive pressure o150 Pascal shall be nia inta i ned in the Ii ft shaft, The mechanism for pressurization shall act automatically with the fire alarm: it shall be operable mechanically also. I Exit from the lift lohb> if located in lie main portion of the building, shall be through a seltclosing snioIc stop door of hal I an hour fire resistance. J Lifts shall not normally coni 'ii un icote with the haseme nt i C ho ever, Ii fis a c in st'c Ii conim tin cat ion, he Ii fi lobby of t lie basements shall he pressurized ith sd f-ci using door as above. K Switch(cs) at ground floor level, shall be provided on all the lifts to enable the fire service from rouiid to the lifts. L Telephone or other comm tin i cation bc ii ties shall be ploy ided iii lifI a' rs lbr build Jig of 30 m height and aho e. Coinmtinication system for lifts shall he connected to fire control room 'or the bu I di M Suitable arrangements, for providing slope in the floor oil ifi lobby shall be made to prevent 'ater. used during fire fighting at ally landing, from entering the lift shafts. N A sign shall be posted and maintained on cveiy floor at or neLr the lift indicating that in case of fire, occupants shall use the stairs unless instructed orhenvise, The sign shall a iso contain a plan for each floor showing the locations of the stairways. 0 Alternate source of poer supply shall be provided for all tl e lifts through a manuatly operated changeover s" itch. IS Fire Lift- (NBC-P-2-4.4,2.5)(NBC- p.4-annex-C-i .5) No. - A Minimum one Fire Lift with capacity not less than 545 kg/S persons lift for every 1200 sq. meters. area. Details Capacity Fire Liftl Fire Lift2 B For every type of high rise buildings, fire lift is essential. Following details shall apply for a fire lift I To enable fire services personnel to reach the tipper floors with the minimum delay, one fire lift per 1200 sq meter of floor area shall be provided and shall be available for the exclusive use ofthe fireman in emergency. 2 The lift shall have a floor area of not less than I .4m2. It shall have luadhig capacity of not less than 545 kg (S persons lift) with automatic closing doors of minimum 0.Srn width. 3 The electric supply shall he on a separate service from electric supply mains in a building and the cables run in a route safe from fire, that is - ithin the lift shaft. Lights and fans in the elevators having wooden paneling or sheet steel construction shall be operated on 24 V supp1y 4 Fire fighting lift should be provided vith a ceiling hatch for use ir case of emergency. so that when the car gets stuck, it can be easily opened. In case of failure of normal electric supply, it shall automatically trip o'er to I alternate supply. For apartment houses, this changeover of supply could be done through marntally operated changeover switch. Alternatively, the lift shaH be so wired that in case of pJ'ver fhilure. ii comes down at the ground level and comes to stand still with door open. 6 The operation of a fire lift is by a simple toggle or two-button sv itch situated in a glass-fronted box adjacent to the lift at the entrance level. When the s itch is on. landing cull-points will become inoperative and the lift vili he on car control only I or OIl a priority control device. 'heri Hi e switch is off, the lift vill return to normal working- [h is lift is usable by the occ impants in normal tin] es. 7 The words Fire Lift shall he conspicuously displayed in florescent paint on the lift landing doors at each floor level. 8 The speed of he fire lift shall be such that it can each the top floor or any refige floor from ground level with in I miii. 19 Refuge area (NBC-P-2-3.4.5.5/Annexurc-E-1) Sq Meters. (NBC- p 4-4 113 & appcndix-D) At floor No-. ....... 2{) Fire Tower- (NBC- p4-3 and 4.13)At height-Meters 21 Arrangement of Exits and Other Exit Requirements / 4-4.4.2.2 / 4.42.3) 4 Appendix-C) (NBC -P-4.4,2 (NBC p4 A Exits shall be so arranged hat the travel distance on the floor shall be within the Stipulated limits as per National Building Code for a particular class of occu pari and should not be more than half of that travel distance from the dead end of r corridor with the exception that for assembly and institutioria occupancies it shall not exceed 6 meters. B Lift and escalators shall not be considered as exits. C Every public place to have sufficient safe exits — without passing through another occupied unit. D Capacity (aggregate width) of exits shall be based on occupani load (in the affected floor (s)) and occupants that can be safely evacuated per 50cm of exit. E Fire-check doors for fire resistance of two hour to prevent spread of fire! smoke, in escape routes, particularly at entrance to lifts and stairs which are prone to fire ismoke effect. F Number of persons ithin any floor area or occupant load shall be based on actual. G Travel distance of exit stairs should be according to occupancy. These should be at distance to one another and should provide exit in different directions, For basements travel distance should not exceed I 5 meters. F! For continuous safe exit, it shall open into corridor or in enclosed staircase through landing. I Staircases slial I be of enclosed type J Exit doors to be openable without keys. K Route to be always lee ofany obstructions. 22 Enclosed vertical openifigs (NBC-P-3.4.5.6) Every vertical opening between the floors of a building shall be suitably enclosed or protected to prevent spread of fire, smoke, or fumes through vertical openings from floor to floor so that occupants car use the same as means olegress in case of ire. 23 Corridors and Passageways( NBC-P-4.4.4.2.4.2)(NBC 4-4.8.1/4.8.3) p A The width ofthe corridors and passageways shall not be less than the aggregate required width of exit doors. B The above (and stairs/lifts) shall have fire! smoke resistance doors. C Exit corridors and passageways shall have adequate width as stipulated for a particular class of occupancy. 1) Nave adequate ventilation F Adequate light to ensure safe travel 24 Horizontal Exits( NBC-P-4-4.2.4! Annexure-E-4) 4-4.12.1125) (NBC p A To have with the same width at least one fire door of self closing type 3 Doors to be openable at all times from served side(s) C The width of horizontal exit shall be same as for the exit doorways. A horizontal exit shall be fitted with at least one lie smoke check door of ni inimum I hr fire ratin. 25 E, cape Lighting and Exit Signage NRC-P-4-3.4.7XNBC- p-4-4.?.7:4.l6.3/4/l0.Cl.l4bi4.l6:appendxDl .141 Emergency lighting shall bc pow cred from a source i midependent of that sup pi) imig I lie normal lighting. Escape lighting shall he capable of: a) Indicating clearly the escape routes, b) Providing adequate ill urn i nation a long such routes to allow sa ma' ement of persons towaids and through the exits, c)Ensurfng the access of firemen or equipments to the Fire alani call points and the escape routes. d) The em ergencv I iglit in g should automat cal ly a cti vale wit hiri secon U of the fail tire of the normal lighting system. e)The emergency lighting system shall be capable of continuous operation for a minimum duration of I hour and 30 minutes even for the smallest premises. B AU escape Exit routes to have clearly visible & illuminated signs (auto glow sinages) with battery backup elliergency alternate power supply. C It should be powered by source independent of normal power, for stairs! exit routes & fire alarm with one and halfhrs. battervbackup. 26 Basemcnts( NBC-P-4-4.2. 19) (NBC- p-3-12.9.3 & p-4-C. 1.6) A Every basement shall be, in even part, at least 2.4 m in height from the floor to the underside oldie roofslab or ceiling. B The minimum height ofthe ceiling of any basement shall be 0.9 m and the maximum 1.2 m above the average surrounding ground level. C The access to the basement shall be separate from the main and alternative staircase providing access arid exit from higher floors. D Where the staircase is continuous in the case of buildings served by more than one staircase, the same shall be of enclosed type serving as a fire separation from the basement floor and higher floors. F The staircase of basements shall be of enclosed type situated at the periphery of the basement to be entered at ground level only from the open air. F It shall he in such positions Ihat smoke from any fire in the basement shall not obstruct any exit serving the ground and upper stores of the building U It shall be connected with basement tkough a lobby provided with fire resisting self closing doors of hour resistance. H Open camps shall be permitted ifthcy are constructed within the building line. I Ifthe travel distance exceeds as required, additional Staircases shall be provided at proper p'aceS. i Adequate ventilation shall he provided for the basement. The ventilation requirements shall be the same as required by the particulars occupancy accordimz to bve1aws K kny deficiency may be met by providing adequate mechanical ventilation in the form of i owers. exhaust fans, air conditioning system etc. L Each Basement shall be separately ventilated. NI Alternatively, a system of air inlets shall be provided at basement floor level and smoke outlets at basement ceiling level. N Stall board and pavement lights should be in positions easily accessible to the Fire brigade and clearly marked. 0 lii Multi-storey bascitients, intake ducts may serve all basement levels, hut each basement level and basement conipartrnenl shall have separate smoke outlet duct or ducts. P Ducts so provided shall have the same fire resistance rating as the compartment itse If. Q Smoke from hasenieifl fire shall in no case ingress into any exit path /staiis serving upper floors. R Mechanical extractors for smoke venting system from lower basement levels shial I aso he provided S ihe system shall be of such design as to operatc on act Liii t ion of heat stoke sens ti detectors or sprii Lii I cr5, if installed. 1 Ni cc hanica I extractors slia II have an internal locking arrangeritent, so th at extractors shall continue to operate and supply fans shall stop automatically with the actuation of fire detectors. U It shall also have an arrangement to operate it manually. V Use of LPG Pressure stove in basement is prohibited, liile iI other areas 4 liotirs ire- resistant enclosures are pennitted. W Adequate arrangements shall be made so that surface drainage does not enter in tobasement. X The walls and floors ofthe basement shall be water tight. 27 Fire Rating-(NBC-P-4-Annexure-C) (NBC-p-4-3.4.7/3.4.8/3.4.8.I/3.4.8.2/3 andCl.9) A [ía building has more than one occupancy it shall comply with requirements ofthe most hazardous one, unless 4 hours rated separating wall is provided B There should be lire resistant doors ofl hour rating, in escape routes, particularly at entrance to lifts, staircases. C To prevent the spread of fire, there should be 2 hours rating fire resistance doors! steel rolling shutters. D There shall be 2 hour fire resistance cable of wall and floor inside the duct! shaft with 1 hour rating fire resistance in inspection door. E All fire safety items like fire resistant doors shall be provided. F Surface finishing on walls / ceilings/facade shall minimize the spread of fire or toxic fumes. G Finishing material used for interior surfaces and decoration shallnot generate toxic smoke. H Use IS 2777 "Class I flame-spread", surfacing material, and fabric materials used for decoration. camets curtains etc. I Wafls, partitions or floors lined with combustible material, to have surfaces conforming to IS 1642, to prevent rapid fire spread, hampering escape of occupants. 28 Compartmentalization (NBC-P-4-4.5) A High Rise Buildings should be suitably compartmentalized so that fire/smoke renlains confined to the area where fire incident has occurred and does not spread to the remaining part ofthe building B Compartmentation (ifany). speci the specific detail of fire resistant doors/stops. C All floors to be compartmented into 750 sq. meters area through 2 hours rated fire separation walls. D Whether compartmentation is proposed to confine the fire/smoke to the area where fire incident has occuned (Cl C.9 Annexure C, Pad 4. NBC. 2005) 29 Smoke NBC venting ( -P-4-4.4.2.5!4.6) (NBC-p-4-3.4.1/124.2.9.C.I.63.4.6.4.2.64.4,6.4.6.11,3.4.6.4.4.54,5) A Automatic smoke vents, with minimum 3.3% of floor area, in assembly areas and balconies, shall be installed. B Automatic smoke vent may be substituted with po ereci exhausters with department's permission. C Automatic dampers shouJd be closed, to prevent spreading ofsnioke in case offire or smoke at AC's outlet. D Mechanical ventilation & smoke exhaust system E Vents for smoke to minimize their spread F Vents should be minilutini 25% of floor area of basement to prevent spread of smoke. 30 Electrical Installation ( NRC-P-4-3.4.63.4.5.4 and Part-8) Section-? of National Electric C de. 2011(NBC- S-3.9.I.5 9.2) A II lectrica I I nsta I lat on s shal be by licensed electrical coni i-actor and supervised by the holder of competency-certificate/permit issued by Governnicnt. B Complete drawings showing all circuits to enable functional checking. C [he e}cctric power distribution cable. wiring shall be laid in a separate duct. [he duct shalt be sealed at every floor with non-combustible materials having the same fire resistance as that of the duct. Low and mediimni voltage wiring running in shaft and in false ceiling shall run in separate conduits. D Water mains, telephone lines, intercom lines, gas pipes or ally oilier service Ii pie shah not be laid in the duct for electrical cable: use of bus ducts/ solid rising mains instead of cables is preferred. E Fire Alarm/PA. Systems (Note: Auto start and auto switch over from normal to emergency source should be ensured) F Separate circuits for firefighting pumps, lifts, staircases, corridor lighting and blowers for pressuring system shall be provided directly from the mail, switch gear panel and these circuits shall be laid in separate conduit pipes, so that Fire in one circuit will not affect the others. G Such circuits shall protect as automatic circuit breaker at main point. H Master switches controlling essential service circuits shall be clearly labeled. I At every floor level seal space between cables etc and shaft with fillers, to stop fire. .1 The inspection pan& doors and any other opening in the shaft shall be provided with airtight fire doors having fire resistance ofnot less than I hour. K Periodical verification of efficacy of emergency/alternate power supplies and related escape and fire safety equipment (IS- 1646-3.6 andl 1.6) 1, Electrical fires being common cause of fires, strict compliance I.E.R.30 (ISI, electrical material) and 15-737 and NBC-P-8-2. (electrical wiring), is essential. Compliance with IS. 1646; 732, 10028, regarding fire safety of buildings, electrical wiring and transformers as are mandatory. For electrical Safety compliance of Indian Electrical Rules, including related Indian standards/ Codes stipulated there in is also mandatory (N.E.C-Part 3-3 and lS-4878-14: IS-1646 and 732). 31 Sub- Station ITransformers (NBC-P-4-3.4.6.3! Part-8) A Transformers room! enclosure, location and ventilation/exhaust to be such that no smoke firmes there from can ingress into exit/escape routes or parking or other parts of the building. B Transformer plinth should be at least 15 cm. above grade and if oil filled, provision should be made to prevent egress of leaking oil into any parking area. C Indoor transformers should have auto high velocity water spray or emulsifying system (IS-15.lO.3) D Transformer shall have soak pit. fencing and provided with 45 Ltr. foam trolley E A sub-station or a switch-station with oil filled equipment shall not be located in the building. F The sub-station structure shall have separate fire resisting walls! surroundings G The sub-station structure shall necessarily be located at the periphery ofthe flow having separate access from fire escape staircase. H The outside walls, ceiling, floor. openings including doors and windows of the sub- station area shall be provided with a fire resisting door of 2 hours fire rating. I Direct access to the transformer room shall be providcd. preferably from outside the fire escape staircase. 32 Stand by source of power supply- ( NBC-P-4-3.4.6.2) Automatic — N1anuziI — 33 Air-Conditioning System( NI3C-P-4-3.4.8) A Escape routes like stai'cases. common corridors, Iii lobbies, etc - shall not he used as return air passage. B The ducring shall be constructed of adequate gauge metal. C Wherever the ducts pass through fire wall or floors, opening around the ducts shall be sealed with materials having tire resistance rating ofthe compartment D Where a duct crosses a compartment, which is tire rated, the duct shall be fire rated for same fire rating. E The material s used for insulating the diet system (i ii5 de or outside) shall he o t 'ion- combustible materials. Glass wool shall not be wrapped or secured by any material of conibustible nature. - F Area more than 750 m2 on single floor shall be separated by a fire wall and automatic fire dampers. 0 Air duet serving main floor area, corridors. etc., shall not pass through the staircase enclosure. H The air-handling units shall be separate for each floor and air ducts for every floor shall be separated and in no case inter-connected with the ductin&of any other floor, I The veffical shaft for fresh air shall be of non-combustible materials. J The air filters ofthe air-handling units shall be ofnon-conibustible materials. K The air handling unit rooms shall not be used for storage ofany combustible materials. L Inspection panels shall be provided in the main trunk to facilitate the cleaning ofducts, M Fire Dampers (a These shall be located in conditioned air ducts and return air ducts! passages at the fo owing points: (i) at the fire separation wall (ii where ducts pass through floors, and; (ii')at the inlet ofsupply air duct and the return air duct ofeach compartment on every floor: (b) The dampers shall operate automatically and shall simultaneously switch off the air- handling fans, Manual operation facilities shall also be provided. 34 Provisions of rroteetion against lightening- -( NBC-P-4-3.4.6.5) 35 Minimum Fixed Fire Fighting installatioms( able No.07 oFNBC-P-4} (minimum fixed fire fighting installations as prescribed in table 07 of NBC-Part 4 should be rovided. A Detector & Alarm System - (NBC4-4.9)All building with height of IS meters or above shall be equipped with Manually Operated Electrical Fire Alarm (MOEFA) system and automatic fire alarm system in accordance with good practice. A-I Manually operated electrical fire alarm system (MOEFA (Tahle-07) A-2 Manual Call Alarm Points in the entire building. Total Number .... A-3 MOEFA shall be installed in the building with one or more call boxes located at each floor. The call boxes shall conform to Rood practice A-4 The installation of call boxes in hostel arid such other places where these are likely to he misuses shall be avoided. Location ofall boxes in dwelling units shall preferably he inside the building. B Automatic Detection & Alarm System ( NBC-P-4-4.9 arid 1able-07) B-I Smoke Detectors Total Number B-2 1-leat detectors. Total Number B-3 Beam Detectors (Please relèr IS 2189:1999) Total Number B-4 Fire detection control panel in floor- Total Number C Automatic Sprinl:ler Svstem( NBC-P-4-2.6.4.2 5 1.3 and lable-07)(Refer IS 15 05:2002) lotal Number D Hose Reels. ( NBC-I'-4-5. I. and Tablc-07) Total Number F Wet Risers (NBC-P-4-2.6.5 and fable-07) local Number F Dry Risers (As per requirement of local authority dry risers amy be used in hilly areas. industrial areas or as required). (3 Down Corner I Yard Hvdrant(NBC-P-4-26.4. land [able07)ITor the F Total Nu nbcr buildings fire pump I !nternal Hydrants on each floor including hasement(s) and terrace Number State Water Storage Resenoirs ( NBC-P-1-5. I .2.1 and Tablc-07) Adequate supply of water for the purpose of fire fighting shall always be available in the form ofunderground I terrace level static storage tank with specified capacity. There shall be arrangements for replenishment by means ofalternative source of supply at the rate of 1000 liters per minute for underground static tank. When this is not practicable, the capacity of static storage tank (s) shall be increased proportionately in consultation with the local fire brigade. K Underground static water tankl tanks, Details trs Total capacity ltrs.. Underground Static Water tank I Underground Static Water Tank 2 L Terrace tank! tanks, Details Ltrs. total capacity ltrs., Terrace Tank I Terrace Tank 2 M Stationary Fire Pumps for pressurizing the wet risen (NBC-P-4-5. 1.2.2 and Table-07) I Pumps : Detai!s ltrsJrn in. capacity Jockey Pump I Jockey Pump 2 2 Electrical Main Pump Details ltrs]min Capacity Pump I Pump 2 3 Standby Diesel Pump Details ltrs.Imin. Capacity Pump I Pump 2 4 Electrica' Pump for Sprinkler Details ltrs./ mm. capacity System ElectricalPunip I EIectricalPump2 5 Booster Pump Details: Itrs 1mm capacity Booster Pump I Booster Pump 2 36 First Aid Fire Fighting equipments / Ex inguishers( NBC-P-4-5.l,l and Table-07) Number- First aid fire extinguishers should he provided as per IS 2190: 1992 Note: - The lhJ I ow Jig ni i ni mum number 0111 re exti ugh i sh cr5 sli ou Id he provided:- I One ABC powder extiiitzuishers of 5 kgs. capacity and 2 no- of lire buckets filled with clean, diy, line sand should be provided for every 8 cal-s. (2) One extinguishers of2 kgs. capacity should be provided near the entrance to each main sw itch board room - (3) ABC poder extinguishers of 5 kgs. capacity should be provided near transformer. il installed. (4) ABC powder extinguishers of5 k!z5 capacity should be provided inside each lift room (5) water pipe gas cartridge extinguisher of 9 ltrs capacity should be kept near each staircase landing on every floor. (6) Scale of suitable extinguishers for other areas shall he fixed separately- After collection oi[ the scales of suitable fire extinguishers for every areas and finalization of the shape of utility in each area ThaI approval shall be obtained from the Fire Service. (7) AU the extinguishers suggested above should be with BIS Mark and should be located at an easily accessible position without obstructing the normal passage Sr. No. 1 pent Exti nguishrs Capacity Quality Make Sr.No ./Explosi' e No. Year or N tanuthcturing Year of Purchase 151 mark Rem i-ks' Re Ii rn Date 37 Helipad (NBC-P-4- Annexure-E-8) For Buildings ofrnore than 200 meters. height, whether helipad is provided 38 Fire Control Room: - (In the entrance lobby)( NDC-P-4-3.4.12) I. with public address system between the various floors and the fire control room 2.Provision of intercom between various floors and the fire control room- 39 Fire Safety Officer- ( NBC-P-4-4.I0.1/4.10.2)(under section 29 of the Bihar Fire Service Act, 2014) Provided individually- Provided with other builders- 40 Fire Drills & Fire Orders :-( NBC-P-4-4. II & Annexure-D) A Provision ofsysternatic training ofoccupants in fire prevention B Fire notice / orders shall be prepared to fulfill the requirements of fire fighting and evacuation from the buildings in the event of emergency. The occupants shall be made thoroughly conversant with their actions in the event of emergency by disp{aying fire notices at vantage points and also through regular training. Such notices should he displayed prominently in broad letter. 4! Fire and Life Safety Audit - ( NBC-P-4- Annexure-E-7) Date ofFire Audit- 42 Whether estimates for Fire Safety System (Certified by the architect) is submitted? 43 Whether 15% ofthe estimates ofFire Safety System as Bank Guarantee is submitted?Rs 44 Whether bank draft for obtaining NOC is submitted? 45 Provide name address, license No.. signature oftechnical staff uilaer B Archilect C Structural Engineer D Electrical Contractor E Fire Safety Systems Contractor It is certified that the information given above are correct. No information has been concealed, misrepresented or falsiFied. I understand that in the event of any wrong information provided in the above check list. Ihe provisional/ final NOC is liable to be withdrawn/ cancelled by State Fire Set-vice. Signature ofArchitect! Engineer! Builder! Electrical contractor! Fire Safetj System Coordinator. I FORM-il Affidavit I Undertaking regarding compliance of provisions of various Acts and Rules Jzuarantee of expenditure in tire safety system and equipmentsand others. (I nder seclloil- 02 (g) of Bihar F ire Ser ice Ac', 20 14. tinder ruic- 5 I) (i ) of Ui har Fire service Rules. 2(12 I Folloing undertaking is given in favour of the State Fire Officer-cum-Director, Bihar Fire Service:- We declare that we are Builders, Promoters and Developers of the building situated at We undertake to comply with all the passive & active fire system measures as stipulated in National Building Code, 2016 as amended from time to time, Multi storied Building Regulation,19l. Bihar Building Byclaws, 2014 as amended from time to time, Bihar Fire Service Act.20l4, Biliar Fire Service Rules,2o2land advice contained in provisional NOC. 2. We undertake to give information regarding commencement of work under section 10 of I3ihar Building Byelaws, 2014 as amended from time to time. 3, We undertake to give periodic report of construction under sectionl2 of Bihar Building Byelaws, 2014 as amended from time to time. 4. We undertake to give notice to the Authorised officer in prescribed form, in pursuance of Section 15 of the Bihar Building Byelaws, 2014 as amended from time to time. afler completion of building construction work. 5. We undertake to obtain Final NOC for taking occupancy certificate. 6. We undertake to impart training to 40% of the occupants and employees working at building in fire prevention and fire fighting at Bihar Fire Safely Training Academy, Anandpur, Bilita within 6 months from the date of occupation. 7. We undertake to call Fire Service for Fire Audit at regular intervals. S. We underlake to maintain and keep the fire fightingequipmentsinstalled at building in good orking condition at all times by regularly servicing and replacing the obsolete equipments. 9. We state that we have prepared the estimate of Rs towards the provision of all fire fighting systems and the estimate in original along ' ith the check list of fire safety measures is being submitted for approval. 10. We undertake to furnish Bank Guarantee for 15% of the total estimated cost of fire safety 5' siems as above in favour of Director, State Fire Services, obtained from the Nationalised Bank. II. We agree that the above Bank Guarantee can he invoked by Director, StaleFire Services at ally time in the event of non-provision or noll-mainlcnanlce of firefighting systems in our building as per concerned Code, Act, Rules, Regulations or fl the event of non-compliance of any other fire safety measures suggested in the provisional no objection Certificate, Signature of the Bu i ide r/Pro mote r/Deve loper Name Designation:- Place Address for Correspondence- Date:- Contact Telephone number- FORM--E Provisional Fire Prevention and Fire Safeh No Objection Certificate (Uiidcrsetlion-2 g)otI3ihar Fire Scr'iceAcc 2014. under rulc-I5 (fl(iii) ofRiharFire SericeRuIes. 2021) Office of the Director, State Fire Service, Bihar, Patna From, To, Director, State Fire Service Bihar. Patna. SI.. No Dated Application of MIs (Unique ID. No Sub:- Issue of provisional No Objection Certificate for Construction of Building. Sir, As per recommendations of Building Plan Advisory Committee of the State Fire Service, Bihar the Provisional No Objection Certificate is issued for construction of the Building I Block proposed by MIs. as per Rule 15 (f)(iii) of Bihar Fire Service Rules, 2021. The name of the building of the proposed building plan is of occupancy sub-occnpancy with a height of meters, floor area Sq meters,number of Floors number of basements number of stilts / ground floors number of blocks average occupant load per floor number of lift ......number of Fire lift number of ramp ......number of refugee area number of Fire tower We approved the plan after giving following advice/suggestions/ recommendations based on NBC guideline, local building byciaws and the local circumstances which must be followed by the concerned Architect / Developer/ Land owner as the case may be. The building plans are forwarded herewith after countersigning the same for your approval, (I) The builder has proposed open spaces (in meters) for the building (North South East West ) and for Means of Escape (Internal Staircases- number .....width meters/External Staircases- number...., width .......meters) (2) Open Space &Approach: (a) The open space around the building shall conform to the relevant bu ding hyelaws and other concerned Act! Rules! Rcgulations/ local requirement as s elI as permit the accessibility and maneuverability of Fire appliance with turning facility 3.60 m/s (minimum) (to be changed according to building categories and construction). (h) The approach roads shall be wide and sufficiently strong to withstand the load of Fire Engine weighting up to 20 MT. (c) The ddtli and height ofthe access gates into the premises shall not be less than 4.5 M and 5M respectively. (3) Construction: (a) The "hole constrtiction of the proposed building shall he carried out as per approved plan drawing conforming the relevant building rules of local Municipal Corporation and Biliar Building B>elays. 2014 as amended from time to time. (b) The floor area exceeds 750 m 2 slia II he suitably couipartiiiented by sept rat ion walls up to ceiling level having at least t o hours Fire resisting capacity. (c) The interior finish decoration of the building shall he made of low flame spread materials conthrming IS. specifications. (d) Provision of ventilation at the crown of the central core-duct of the building shall be provided, Arrangements shall have to be made for sealing all the vertical ducts by the materials of adequate fire resisting capacity. (4) Staircase (a) The Staircase of the building shall be of enclosed type. Entire construction shall be made of brick / R.C.C. type having Fire resisting capacity not less than 4 hours. (b) The Staircase of the building shall have permanent vents at the top equal to 5% of the cross sectional area of the staircase. Operable sashes at each floor level equal to 15% of the cross section area shall have to he provided in the external wall of the building. (c) All the Staircase of the building shall be accessibleto each other in each floor without entering into any room and shall be extended up to respective terrace. The roofof the Stair wall shall he Imeter above the surrounding roof area. (d) The width of the Staircases and corridor and travel distance of different categories of occupancies shall have to confirm the relevant building rules. (e) In case of two staircases, one must be on outer wall. (t) Both staircases should not go down to basement floor, for approach to basement. There should be another staircase for approach. (5) Fire Safety Systems-The approved plans are forarded subject to provision of the following tire safety measures to be provided as per reqturement in National Building Code, 2016 as amended from time to time- (a) Hose Reel (b) Wet Riser-curn-down coiner system ( .....Nos.) (c) Yard 1-lydrant system. (d) Manually operated electrical fire alarm system (e) Automatic Detection and Alarm System in the entire building (1) Sprinkler System (as required) (g) The Underground static water tank of litres capacity (h) Overhead lank of litres capacity (i) A pump house LPM Electrical and Diesel. LPM. Jockey Pump and LPM Booster pump 6) Fire E3xtingu slier (6) Other condilions to be followed as per the relevant Act/Rules/Regulations like Bihar Building Bvelaws. 2014 as amended from lime to time. National Building Code of India. 2016 as amended from time to time. Multi-Storicd Building Regulations. 1981 Bihar Fire Service Act. 2014. Bihar Fire Scrvice Rules. 21)2! as required in concerned occupancy. Some of the cond it ions are as fbI lows- (a) LIFT:- (i) 'Ihe walls of the lift enclosure of the building shall be at least of two hours fire resisting tYpe. (ii) The lift of the building shall be designed at high speed Fire Lift and cIearlmarked in the plan. (iii) In case of failure of normal electric supply. there should be automatic aherriate arrangement, For apartment muses these changeover of supply could be done through manna I ly operated change over switch, Alte natively, the lift shall be so w red that in ease of power failure, it comes down at the ground level and comes to stand still with door open. (iv) Arrangement shall be provided for extraction of smoke in the entire lift shaft by incorporating smoke venting system designed to permit 30 air changes per hour in case of lire. It shall be so designed as to operate on actuation of sprinkler or Fire Alarm. In case of failure of normal electric suppiy. it shall automatically trip to alternate supply. (v) All other requirements shall conform the IS. specification including the communication facility in the lift cars connecting to the Fire Control Room of the building. (vi) Fire Lifts, complying with concerned clause of National Building Code of India, 2016 as amended from time to time shall be provided i.e. one Fire Lift for 1200 sq. meters of floor area. (b) There should be active fire protection system such as down coiner system with landing valve and hose reel at each floor ith 900 LPM pump at Terrace level. IS! marked fire extinguishers as per relevant specification and 1,5 2190/1992, firecheck door, manual call alarm point,fire safety luminescent sign and other fire precautionary measures as mentioned in NBC should be provided before occupancy. (c) The basement should be equipped with automatic sprinkler's installation and mist have two separate exits. (d) An underground water static tank of not less than 20.000 Ltrs. capacity with automatic refilling arrangements where Fire Brigade vehicles can reach easily. Overhead water static tank of not less than 10,000 Ltrs. capacity should be made available before occupancy (may exceed as per construct ion). (e) The electric cables must be sealed at each floor. (0 The building shall be suitably compartmentalized so that fire/smoke remain confined to the area 'here fire incidcnt has occurred and does not spread to the other paris of the building. (g) Openings in separating walls and floors-Attention shall be paid to all such factors as they will limit fire spreading to these openings and maintain fire rating of the structure. Every wall opening shall be protected with fire resisting doors having fire rating of not less than two hours. All openings in the floors shall be protected by vertical enclosures and the wall of such enclosures shall he ofa fire resistance of not less than two hours. (h) Every vertical opening of the floors shall he suitably enclosed and protected, and folloving shall be provided:- (i) Adequate salëty has to be provided to prevent spread of fire and smoke from floor to floor open space for the occupant "hile using the escape path. Further it shall be ensured to provide a clear height of2 1.00 MM in the escape path of the occupants. (ii) Fire doors with 2 hours fire resistance shall he provided at appropriate places ofihe escape route, and particularly at the cntrance to the lift lobby and on stair to prevent spread of fire and smoke (iii) Smoke venting facilities for safe use of exits shall he provided. (iv) Smoke retardant material only should be used for interior decoration to prevent generation of toxic smoke. (v) Ill wnination of rileajis of exit in staircase and corridors. pressurization of st air cases and basements ventilation shall comply with National Building Code of India, 2016 as amended from time to time. (vi) Air conditioning and ventilating systems slia II be so installed that spread of fire, smoLe or fumes from one floor to other or from outside to any occupied building or structure could be restricted. In case of tire in air filter, (here should be smoke sensitive device in the building tbr restricting the spread of smoke. There should he separate air handling unit on each floor for protection from smoke hazard on each floor. Fire dampers should be provided in the AC system so that in case fire it might be closed automatically and spread of fire and smoke can he kept within limit. (vii) Electrical Installation- Electrical safety shall comply with Indian Electrical Rules. including related Indian standards / Codes stipulated therein. Electrical installation shall be done by licensed electrical contractor. Special attention should be given to cable I wiring in a separate duct, separate circuits, automatic circuit breaker, master switches, inspection panel doors, periodical verification of emergency / alternate power supplies etc. (viii) That Fire exit drill be carried out regularly at least twice in a year after occupation (ix) Fire Safety Officer- as per NBC-2016 and Bihar Fire Service Act, 2014. (x) AMC should be done by a qualified firm or person for the maintenance of Fire equipments. (xi) The setback shall be checked by the Architect! Passing authority as per the established rule. lianything wrong, the Architect / Passing authority shall be held responsible. (xii) It is hereby made clear that in case of any legal dispute arising in future, in which above recommendations have not been complied, the responsibility will fall entirely upon the Developers/ Architect! Landowner and not on the Govt. authority( i.e. State Fire 0111cc, Biliar), (xiii) It is hereby made also clear that this office (i.e. the office of the State Fire Officer- corn-Director, Biliar, Patna) is not respoi1sible for any legal dispute of the land upon which the proposed building shall be constructed. (7) Shall compulsorily follow the undertakings. (8) This shall be treated as provisional. On compliance of all the above Fire and Life Safety recomnmendations this office shall be approached for necessary inspection and testing of the installation. Final no objection certificate shall he issued on being satisfied on all points. (9) Any deviation or changes in respect of the approved plan drawing, without obtaining prior permission from this office, this provisional NOC will be treated as cancelled. (10) The maps are being returned with sign arid stamnp/ being cleared online. Yours faithfully, ( ) Director. State Fire Services B ihar, Pat na. Copies o(as required): M/s. ii) The Chairman Municipal Corporation W itli a set of countcrsigned plans) FORM--F Instructions for remedy of default, if default found in building construction scheme (I nder section 2(g) oithe Bihur Fire Sen ice .Act. 2014. under rule 5 (I) (IV) ci Bihar Fire Service Rules. 1O2l Letter No Office of the State Fire Officer-cum-Director, Bihar, Patna. Date / To, Re!: - Your letter no Date Sub: - For remedy of default found in building construction plan. Sir. With respect to the above reference and subject, it is said that the records related to the building construction plan submitted by you, has been examined by the building construction plan advisory committee. Following defaults have been found after examination: - Hence all the records related to the building construction plan submitted by you are being returned. Please submit the fair and clear copy of the related records, without any type of cutting / overwriting / interpolation, after remedy of defaults found, tothe State Fire Headquarter within 0 days. so that the issue of fire prevention and fire safety no-objection certificate related to your building construction plan may be considered by the building construction plan advisory committee. State Fire officer-rum-Director, Bihar, Patna. FORM--C Information of work progress by the builder Under seclion-2{g) of 3ihar Fire Ser'ice Act. 2014. under njle-15 (1) ( ot flilmr lire Service Rules. 2021) To The Slate Fire Officer-curn-Director Bihar, Patna. Ref.: - Your Letter No Date Sub: - Notice of progress in building construction on the basis of fire prevention and fire safely provisional no-objection certificate. Sir. With respect tithe above subject it is 10 inform that the provisional fire prevention and fire safety no objection certificate no. date has been issued, vide your above referred letter, on the basis of winch the proposed building is being constructed from date keeping in mind the provisions related to fire safety measures. The present condition of construction of the said building is as follows: - (a) Building construction: - Construction completed up to the bottom / plinth / basement / surface floor! (b) Fire Safety measures in the building construction: - Underground tank I is constructed! under construction. Yours faithfully, Address of Building under construclion: - Signature of the Architect Name - Listing number— Signature of the Engineer Name - Listing number— Signature of Structural Engineer Name - Listing number— Date: - Owner! Applicant's Name: - Owner/ Applicant Signzitui- FORM--H instructions to the builder for remedy of default in case of finding of lapses in compliance of conditions in provisional no objection certificate or difference from conditions by the builder. (Under section- 2(g) ofBihar Fire Scricc Act. 2014. under rule-IS (0 (vi) of Rihar Fire Ser'icc Rules. 2021) Letter no / Office of the State Fire Ofricer-cum-Dircctor, Bihar, Patna Date To. Ref. - Your letter no.- date Sub: - For remedy of defaults in building construction, found after verification of work progress. Sir. With respect to the above reference and subject. ii is to say that progress in building construction 'york has been informed b' you. After verification.short comings in compliance of certain conditions of provisional no objection certificate I variations in conditions has been found. which are follows:- So please inform the undersigned quickly after resolving the above defaults found in the order of building construction, otherwise the final fire prevention and fire safety no objection certificate ma' not be issued, State Fire Officer-cum-Director, Bihar. Patna. FORM--I Information regarding completion of building construction to be given Lw the builder for obtaining final fire prevention anti fire safety no obiection certificate. (Lnderscction-2(g) ofBEli FireSericc Act. 2014. under ruc-I5 M(i) olBiliar Fire Serdcc kulcs. 2(121) To, The State Fire Officer-cum-Director. F3ihar, Patna, Ref: - Your letter no.- date Sub:- Information of completion of building construction work on the basis of provisional fire prevention and fire safety no objection certificate. Sir, With respect to (lie above mentioned subject, it is to be informed that the provisional fire prevention and fire safety no objection certificate rio.- date had been issued vide the referred letter, for construction of the building, on the basis of hich the construction of the proposed building was started from dale keeping in view the concerned provisions of fire safety measures. The information of progress in building construction work had been given vide letter no.- date The construction work of that building has been completed. It is certified that the provisions of fire safety measures has been done according to the advice and conditions mentioned in provisional fire prevention and fire safety no objection certificate and in the light of the provisions of National Building Code. 2016 (Part-4). The concerned check list with up to date position is attached for convenience. It is requested to issue final tire prevention nd flre safety no objection certificate after checking of arrangements regarding fire safety measures in the constructed building. so that further action might be done in the direction of obtaining the occupancy certificate. Enclosure- checklist Yours faithfully Address of the building under-construction date Signature of the Architect- Name: - Listing number: - Signature of the Engineer: - Name, - Listing number: - Signature of the Structural enginee Name: - Listing number: - Name of the Oner I Apphcaut. - S gnat nrc of the Owner / A pp ca ii : - (nntd Checklist for final no objection certificate (I) Copy of the previously passed map concerned with provisional no objection certificate. (2) Approval of the municipal authority for construction of the building in which following points concerned with the site should be clearly mentioned- (a) Open space andparking place (b) Access path of 6 meters with vertical clearance of 5 meters for approach to the building (requiredas per building category). (c) Section sketch of the stairs, from which its construction and arrangement of smoke extraction might be clear. (d) Actual site of check doors for preventing the fire and smoke to the evacuation path, lift, stair and compartmentalization. (e) Location of fire indicator, manual call points, sprinklers, hose reel, yard hydrant and wet riser. (f) Basement ventilation,smoke extraction / extractor, exit stair. (g) Location of transformer and generator and arrangement of drainage of air/smoke out. (h) Capacity and location of water tank and pump for firefighting. (i) means of approach to higher floors and refugee area of buildings without windows, for fire fighting and rescue work. (3) Regarding technical statement, specifications, related papers of the vendor and related records for confirmation of ISI in the following: - (a) The various models of fire resistant doors used to prevent the spread of fire and smoke. (b) Pump, hose reel, fire/smoke detectors, sprinkler, hydrant system, fire extinguisher. (c) The smoke evacuation system, written documents of engineers/technical persons elated to installation of ventilation/air conditioning system. (4) Diagram of single electric line for showing separate circuit (certified by the electrical engineer/contractor)- (a) Fire pump, fire alarm lift and PA system. (b) Smoke control/extraction equipment and related ventilation (c) Illumination of the evacuation route showing battery back up. (d) Emergency generator system changeable from normal to an emergency situation. (5) Certificate of electrical engineer/contractor regarding compliance of electrical regulations. (6) Fire control rooms and fire personnels - (a) Alarm detection and communication systems forwarning the occupants and Fire service. (b) Emergency evacuation plan (c) Display at conspicuous locations regarding do's / donts, in case of fire incidents. (d) Instructions for firefighting. (e) Organization of fire personnel/trained occupants for fire fighting. (fl Conduction of fire drills and list of responsible persons for maintenance of concerned records. (7) Name/telephone no/license number/signature of the builder/architect/engineer/electrical contractor/contractor of fire protection system. FORM--J Final No Objection Certificate (Underseelion- 2(g)ofBiliarFire ServiecAc. 2014. under rute-I5 gHii)ofBihar Fire Serice Rules. 2021) Office of the State Fire Officer-cum-Director, Bihar, Patna. (Authorized officer) Letter no.- Date From, State Fire Officer-cum-Director, Bihar, Patna! Authorized Officer To. Ref:- your letter no.- date. - Letter no.- date.- of provisional fire prevention & fire safety no objection certificate. Sub:- For Final fire prevention & fire Safety no objection certificate. Sir, With respect to the above mentioned reference and subject, it is to inform that the information of completion of building construction submitted by you, has been checked in the light of check list enclosed by you. Final tire prevention & fire safety no objection certificate is being issued, in the event of fire safety measures found satisfactory, with following conditions: - (I) The compliance shall be done of the provisions of National Building Code. 2016 as amended from time to time. Bihar Building Byelaws. 2014 as amended from time to time. Bihar Fire Service Act. 2014. Bihar Fire Service Rules. 2021, Bihar Municipality Act. 2007. Bihar Apartment Ownership Act. 2006, Multi-storied Building Act. 1981 and other Act / Rules / Instructions for the time being in force in the light of category of building. (2) The compliance shall be done of check list1 undertakiigs enclosed with the application related to provisional fire prevention & fire safety no objection certificate. (3) A minimum 6 meters (according to building category and building construction) wide access for approach to the building line around the building, shall always be maintained free of any parking obstruction / generator / transformer / security forces / post office I petty vendors / miscellaneous! other constructions / fixtures / 5 meters height of balcony (legally as required). (4) The capacity and width of exit stairs shall be ensured for safe evacuation of the occupants, in the light of the provisions of National Building Code, 2016 as amended from time to time. (5) The fire resistant doors shall be kept in good condition for lini iling the spread of fire and for preventing the entry of smoke in the external stairs / lift. (6) The sprinklers of parking in ground floor! basement shall he kept in perfect orking condition. (7) [he stairs and lift shall be kept in perfect orking condition. (8) [he installed fire extinguishers. alarm etc shall be kept in working condition, by regular checking on the basis of tlw concerned provis oils. (9) Fire safet3 drills shall be done trimonthly in the first 2 years and afler that half yearly. (JO) The emergency generator etc and the concerned equipments shall be checked according to the National Building Code. 2016as amended from time to time and IS-I 644. (II) Installed lire equipments (according to the table no.- 7 of part-4 the National Building Code. 20 6 as amended from time to time). (a) Capacity of the ground water tank- (b) Capacity of terrace water tank- (c) Capacity of electric / diesel /jockey pump at the ground- (d) Capacity of electric / other pump at the roof- (e) Automatic fire detector and alarm system- (f) Manually operated fire alarm system- (g) Automatic srinkler system- (Ii) Hose real- (i) wetriser- U) Down corner- (12) Number of portable fire extinguishers (separate according to the type and capacity). (13) Evacuation plan showing exit routes shall be displayed at conspicuous locations. (14) Fire Safety Officer shall be kept (according to the category of the building). (IS) Fire Control Room, (16) In the event of any type of change to be done in the category of the building, no objection certificate shall be obtained afresh. State Fire Officer-cum-Director, Bihar, Patna A utli orizedOffi c er FORM--K Notice to be given to the builder for remedy in case of not constructing buildino according to the conditions of provisional no objection certificate, found after verification of building after receipt of building construction completion information. (1ndcr section- 2(g) niBiliar Firc Senice Act. 2011. under rule-b (g) (ii) ofRihar Fire Sen ice RUILS. 2021) Letter no. - Office of the Stale Fire Officer-cum-Director, Bihar, Patna Date To, Re Sub: - Sir, Letter no.- date.- of this office and yourletterno.- date. - Regarding removal of default found in fire safety measures, after verificatioD of the building, after receipt of information of completion of building construction. With respect to the above mentioned subject it is to say that the provisional fire prevention and fire safety no objection certificate for building constructions had been issued vide the above referred letter. The information of completion of building construction work was given by you and it has been certified by you that the provisions of fire safely measures has been done in that building according to the ad ice and conditions mentioned in the provisional fire prevention and fire safety no objection certificate and in the light of the provisions of National I3uildin Code. 2016, but after verifications of the arrangements regarding the fire safety measures in that constructed building. folloing deficiencies hae been found in compliance of advice and conditions mentioned in provisional fire prevention and fire safitv no objection certificate:- So please inform the undersigned alter immediate remedy of the above mentioned deficiencies found in the construction of the building . so that final fire prevention and fire safety no objection certificate nay be issued properly after re- verification. Slate Fire Olficer-cuni- Director. I3ihar. Patna FORM--L Notice for ensurina fire safety measures, to the owner of the building, constructed or under construction, without NOC (I nt setioii-2( g) of B I bar F ire Sen ice Act, 201 4. tmder rule- I 5 i) of 13 ihar H re 5cr' ice Ru] Cs, 202 Ij Letter no.- / Office of the State Fire Oflicer-cum-Director, Bihar, Patna. Date.- / To, Sub: - Notice to ensure the desired firesafety measures due to construction of the building without obtaining fire prevention and fire safely no objection certificate and remaining of occupants in risky conditions. Sir, With respect to the above subjeclit is toinform that- I. You are the owner / occupant / builder / office bearer of the associalion of the apartment (building) 2. The fire prevention and fire safety no objection certificate has not been obtained by you for the construction of the above mentioned building. 3. After the fire audit of that building, it has been found Ihat there is severe lackings is arrangements regarding fire safety measures in the buildings, due to which the risk of life & property of the occupants of the building, in the light of fire disaster, in continuing. Under section-35 of the Bihar Fire Services Act, 2014,it is directed to ensure the installation of fire safety measures according to the advice written in the enclosed fire audit report, within days. After that, submit formal application form for obtaining fire prevention and fire safety certificate regarding tire safety measures in that building under rule IS (0(i) of Bihar Fire Service Rules, 2021. In the event of ion-compliance of instructions, legal action shall be done under section-37 and 44 of Bihar Fire Service Act. 2014 and byelaws- 16 (7) of Bihar Building Byelaws, 2014 and rules 22(c) (g) (Ii) (i) of flihar Fire Service Rules, 202!. Enclosure—Fire audit report State Fire Officer-cum-Director. Bihar, Patna. a F'ORM—M Application format to be submitted by owner or occupant of building for Renewal of Fire Prevention anti Fire Safety No Objection Certificate Undcr scciioii- 2 (g ulBihar Fire Sen ice Ac!. 2014. under rule-IS i (Ii) of Rihar Fire Sen ice Rules. 202 To, The State Fire Oflicer-cum-Director. Bihar, Patna. Sub: - For renewal of Final prevention anti fire safety no objection certificate. Sir. With respect to the above mentioned subject, it is to inform that the final fire prevention and fire safety no objection certificate had been issued vide your office letter rio.- date.- after checking of the site of building construction, n the tight of the information of completion of building construction work, whose validity period is fixed till date.- It is certified that the provisions of the fire safety measures had been done according to the advice and conditions mentioned in final fire prevention and fire safety no objection certificate and in the light of provisions of National Building Code, 2005 (part-4)/ National Building Code, 2016( part-4) which is in working condition. It has been checked by the fire expert. ihe check list (in check list format prescribed for provisional and final fire prevention and tire safety no objection certificate) related to present arrangements of fire safety measures has been prepared b tilling in it. The checking report of the fire expert and check list are being enclosed. The photocopy of the chcck list, submitted earlier, for obtaining final fire prevention and fire safety no objection certiFicate, is also attached for convenience. It is certified that no change has been done in the category of the building after issue of the final fire prevention and tire safety no objection certificate. it is requested kindly to renew the final fire prevention and fire safety no objection ceilificate after checking of arrangements related to fire safety measures in the subjeAed building. Enclosure: - lChecklist Yours faithfully 2.The checking report of the tire expert Signature of building owner /nianager Address of the building: - Name- Address - date FORM--N Renewal ofNo Objection Certificate of building nder sect ioii 02 { g) of 13 liar F re Sen ice Act, 20 4. under rule- 5 (j ) (I) ui J ihar Fire Service Rulec. 202 I Letter no.- I Office of the State Fire Officer-cuni-Director, Bihar, Patna Date.- / To, Ref: - Your letter no.- date - Sub: - Renewalof the fire prevention and fire safety no objection certificate. Sir, With respect to the above mentioned reference and subject, it is 10 inform that the application form submitted by you, with check list in prescribed format and checking report of fire expert related to fire safety measures, for renewal of fire prevention and fire safety no objection certificate ,has been checked! made checked. After checking, the renewal of fire prevention and fire safety no objection certificate related to your building is being done with conditions for period. Please, the advice and conditions mentioned in the fire prevention arid fire safety no objection certificate shall be complied with and the fire safety measures, according to the check list submitted, shall be kept in working condition, In additions to this, the provisions related to fire safety measures of National Building Code, 2005, (part-4)/ National Building Code. 2016 part-4). Bihar Building Byelaws, 2014. Bihar Fire Service Act. 2014, Bihar Fire Service Rules, 2021 and related other Act! Rules/ Regulations shall be complied withEspecial!y, the checking of fire safety measures by fire expert and checking of electrification by elecirical engineer or competent authority shall be done at regular interval. Again, it will be compulsory to obtain no objection certificate from the Fire Service, in the light of fire safety, before any type of change in the category of the building. State Fire Oflicer-cuni-Director Bihar. Paftia, FORM--O Notice for cancellation of No Obiection Certificate of buildinz in case of failure in maintenance of fire safely measures according to NOC. tindcrseclion- 2 (g)oifliharlire ServiceAci. 2014. inderrul-I5 (k)(IohI3iIiarFire Scr'kc Rules. 202!) Letter '10.- / Office of the State Fire Officer-cum-Director, Bihar, Patna Date- / [0, Sub: - Notice regarding cancellation of no objection certificate due lo default in maintaining fire prevention and fire safely measures. Sir. With respect to the above mentioned subject, it is to say that the fire prevention and fire safety no objection certificate, related to your building! premises, had been issued vide letter no.- date- Renewal had been done vide letter no.- date- The fire audit of your building, in the light of fire safety, has been done/ made done, from which it has been found that default has been done by you in compliance of advice related to fire safety measures, which are as follows:- (I) (2) (3) (4) Due to lapses done hvyou in compliance of fire safety measures, there is probability of risk of life and pronerty of the occupants of that building I premises arid nearby building / premises from fire disaster. Please, explain within days that why not the fire prevention and fire safety no objection certificate related to your building / premises, should be cancelled. In case of cancellation of theno objection certificate, the public or commercial uses of that building will not be done. State Fire Officer-cum-Director [3har. Patria. I FORM--P Appeal by owner or occupants of the building after cancellation of No Objection Certificate ofbuilding. U' Jcrsection-2 (g)otI3ih3r Eke Servfce Act. 2014. underrule-15 (k) (iii)ntBihrFire Scr'ice Rules. 2021) To, The Director General. Bihar fire service, Bihar, Patna. The State Fire Officer-cum-Director, Bihar. Patna. Ref Letter no.- date- of the State Fire Offleer-cum- Director, Bihar, Patna. Letter no.- date- of the (Authorized Officer) Sub:- Appeal against notice regarding cancellation of no objection certificate, due to default in maintaining fire prevention and fire safety measures. Sir. With respect to the above mentioned subject, it is to say that the notice has been given by the vide letter no.- date - for cancellation of fire prevention and fire safety no objection certificate (lelter no.- date- / renewal (letter no.- date- ) related to the building/ premises of the undersigned (name/ address In that notice, it has been mentioned to cancel the no objection certificate on the basis of default in maintaining the fire prevention and fire safety measures, after the fire audit done/ made done in the light of fire safety. of the building / premises of the undersigned. The time limit of days has been fixed for reply of the concerned notice. It is hereby appealed against that notice for hearing on the following points:- (I) (2) (3) (4) It is requested please to take necessary action afier hearing immediately. on (he above mentioned points. Name / address / contact telephone and mobile no. oft heapp tic ant FORM--Q Self- appraisal format to be submitted to the Fire Station Officer, by the owner or occupant or both of the building regarding minimum fire safety measures in the buildings. (Under section-I g) of Riliar Fire Sen ice Ad. 2014. under rule-I 7 (b) olBilrnr Fire Scr ice Rules. 202 (The building onner / oecurjants/ rnanazer / society is responsible for the safety from fire, of the life and property of occupants of the huildirm. The Fire Service will ive advice after fire audit which is to be complied with. The maximum fire safely arrangements can be done vide monthly self appraisal by the building owner / occupants! manaEer / society, before the fire audit done by the Fire Station Officer. Please provide the following format after filling it, every month to the Fire Station Officer of your area and take necessary advice from him, so that maximum fire safety arranzements in the building! premises niight be operational) To, (I) Namecithe building owner: - (In case of apartment,the name of the secretary of the Association of occupants of the apartment) (2) Name ofthe building / address/year of construction: - (3) Type of building (residential / commercial / educational / institutional, etc.): - (4) Height of the building arid floor (basement present or not):- (5) Approach of firefighting vehicles to the building ( hether all-around orjust near the building): - (6) Number of stairs in the building: - SI. No The fire fighting systems done iii the building Month First Second Third I Type / capacity of tire extinguishers:- Expirydate I Refilling dare 2 Down corner system active (Yes or No): - 3 Wet risingsystem active ( Yes or No):- 4 I fuse re& workinu Yes or No) - Number of Fire l-Ivdrant valve ( ) / Number of yard Ii) drants and eftective (Yes or No): - 6 Number ofhose and branch in the hose box: - 7 Sprinkler working (Yes or No): - 8 Smoke detection s stem active (Yes or No): - 9 Fire alarm system active (Yes or No): - 10 Public Address s' stern (Yes or No): - I F ire Conlroi Room ( Yes or No): - 2 (ilo sinage (EXI I sign. eEc) in the building (Yes or No). - 13 Capacity of under wound water tank ( fr) with water (Yes or No): - 14 (apacit' of over head 'at Cr ta uk ( itt) wit Ii 'vater (Yes or No): - 5 Number oftypes ol'air conditioners (split! window / centralize): - 16 Electric connection according to po Cr load capacity ( K VA) in the btuiEdiiig (Yes or No): - 17 Alternate electrical system (Yes or No): - I S Date of fire safety mock drill to be done with occupamits/ workers Nuniber of lifts in 11w building: - Distance of the electric "ire from the bui Wi hg: - Whether advice has been taken from the Fire Service before construction of the building or riot: - Date oIchecking In the Fire Station Officer: - Signature of ownerl Date: - FORM--R Declaration regarding Panda! safety, to be exhibited by the Pandal erectors at the °ate of Pandal and at main visible places. (Under seclion- 26(21 ofRiliar Fire Service Act. 2014. under rule- IS (h) ofl3ihar ire Service Rules. 202 To, I (name of the panda! maker), place of registered office registration no declare that the panda!! temporary structure of square meters made at (P!ace) vill remain on that place from (Date) to (Date). [he arrangements for fire prevention and fire safety measures has been done during panda! construction as per instructions in Bihar Fire Service Act, 2014 and Indian Standard Bureau, 15-8758-1993. In addition to this, the provisions of Explosive Substances Act and Indian Electricity Rules has been fully complied. It is also declared that following trained personnel will he present in paiidal/ temporary structure for fire safety:- 3, Date Place Signature of Pandal maker/owner Copy - Fire Station Officer sent for information p!ease. FORM--S Notice to Pandal erectors for removing defaults or sealing of Panda! in case of defaults found in Fire Safety measures of Pandal. Under sect 011-26 2) ci I B ihar Fire Sen ice Act. 2014. tinder rule-I S (C) of lflhar Fire Sen ice Rules. 202 I) Letter no.- / Office of the State Fire Officer-cum-Director, Bihar, Patna Office of (Authorized Officer) Date - To, Ref:- Letter no .- date- of this office. Sub: - For remedy of default found after enquiry about the veracity of displayed declaration regarding safely of pandal. Sir, With respeetto the above reference and subject it is to say that the pandal has been constructed by you at (sites) and declaration in respect of fire safety in pandal has been made available to the undersigned. Checking of the built pandal was done by After checking, it has been found that the declaration is not true and the following defaults have been found in it: - Soit is directed to inform immediately after resolving the default found above within iours.otherwise action like legally removal! seizure! auction etc of your pandal will be done under rules 19 of Bihar Fire Service Rules, 2021 under section -27 of the Bihar Fire Service Act, 2014. Signature of Director / Authorized officer Name Designation - Seal - a' FORM—T Notice for removing things or goods or encroachment which are probable factors of Fire risk or causing obstruction in fire fighting. Under sec' ion- 27 uI B ii ur F ire Sr' ice Act. 201 4. LLnjcr rule- 9 (a) ui B i bar Fire Service Rules, 2(12 I) Letter no. - Office of the State Fire Officer-cum-Director, L3ihar, f'atna. Office of (Authorized Offleer).- Date- To. (Name and address of the owner! occupants of the buildingspremises.pandal) Ref: - Letter no.- date- of this office. Sub: - Instructions for removing probable factors of fire risk. Sir. With respect to the above reference arid subject ii is to saythat- (I) stuff/objects are present in building! premises owned! occupied by youi pandal made by you, due to which there is probability of fire risk in that premises! building! pandal or nearby premises! building! pandM or 'viii be the reason ofobstruction in conirolling fire in case of fire incident. (2) Under the pcvers conferred vide section-27(l) of the Bihar Fire Service Act, 2014, and rule — 19(a) of Bihar Fire Service Rules. 2021 it is directed that remove those stuffs/ objects or encroachment immediately / within hours! days. (3) In case of iioncornpIiance of the above instruction, report 'sill be submitted to Sub- Divisional Magistrate for legal action tinder section 27 (2)(3)(4)(5) & (6) of Bihar Fire Service Act. 2014. Signature of the Director! Authorised officer Name Designation - Seal- FORM--U Information to the Sub Divisional Magistrate, for legal action, in case of non- compliance of notice regarding removal of things or goods or encroachment which are probable factors of Fire risk or causing obstruction in fire fighting. (Under seeriori.27 ofBihar Fire Service Act. 2014. under rule-I9 (b olBihar Fire Service Rules. 2021) Letter no. - Office of the State Fire Oflicer-cum-Direclor, Bihar, Patna Office of (Authorized Officer) Date - To, Sub:- Sir, The Sub-Divisional Magistrate Request for legal action due to lapses in compliance of instructions, given to the owner/ occupant of the building, premises, pandal for removal of probable factors of fire risk. With respect tothe above subject, it is to say that- (I) stuff! goods have been found during checking on date- at hours, in the premises! building / pandal under ownership / occupancy of / erected by due to which there is probability olfire risk in that premises! building! pandal or nearby premises! building! pandal or will be the reason of obstruction in controlling fire in case of fire incident. (2)Under the powers conferred vide section 27(l) of the Bihar Fire Service Act. 2014 and rule 19(h) of Bihar Fire Service Riles. 2021 direction "as given to the owner/ occupant of the premises/ building / pandal vide letter no- date- to remove those stuffs/ objects or encroachment immediately! within hours! days. In addition to this, he was made acquainted with the report to be submitted to the Sub-Divisional Magistrate for egal action under section- 27 (2) (3) (4) (5) & (6) of the Bihar Fii'e Service Act. 2014, in case of non-compliance of the above direction but the above probable factors of fire ! encroachment has not been removed by him, The petition submitted by hini vide letter no.- date- has been found unsatisfactory. The probable factors of fire risk or encroachments are still present on that site, due to which risk of security of life and property of the common people has arisen. (3) Requested for legal action under section- 27(2) (3) (4) (5) & (6) of the Bihar Fire Service Act, 2014, Signature of Director! authorized officer Name Designation: - Seal:- FORM--V Show cause to be asked from the owner or occupant of the building or premises or Pandal erectors by the Sub-Divisional Magistrate after receiving information regarding non-compliance of notice for removal of things or oods or encroachment which are probable factors of Fire risk or causing obstruction in fire fighting. Under section- 37 of 3 illar Fire Set' ice Act. 20 14. under rule- 19 (c) of 13 ihar Fire S<n ice Rules. 2(12 I Letter no. - Office of the Sub Divisional Magistrate, Date - •!0, (Name and address of the owner/occupant of the building/premises! panda!) Ref:- Letter no.- Date- of this office. Sub:- Show-cause for default in compliance of instructions, given by (lie Fire Service, for removing the probable factorsof risk of fire. Sir. With respect to the above mentioned reference and subject, it is informed that- (1) The premises! building under your ownership! occupancy! the pandal erected by you was verified by the Director! authorized officer, Bihar Fire Service on date - at hour. regarding which a report has been subni [ted by him vide letter rio.- date- During verilication by him stuft/ goods have been found in the premises! building tinder your o" nership! occupancy! in the panda! erected by you or encroachment has been found, due to which there is probability of risk of fire in that premises! building) pandal or nearby premises! building! pandal or will be reason of obstacles in control of tire in case of fire incident. (2) Under the powers conferred vide section 27 (I) of the Bihar Fire Service Act. 20!4. and ruk !9 (c) of Bihar Fire Service Ru!es. 202!. the direction was given by him to you to remove those stuffs or goods or encroachment immediately! within hours! days. In addition to this, you were made acquainted with the report to be submitted to the Sub-Divisional Magistrate for lega! action under section-27 (2)(3)(4)(5) & (6) oi the Bihar Fire Service Act, 2014 in case of non-compliance of the above direction, but the above probable factors of tire incident! encroachment has not been removed by you. The petition submitted by ou vide letter no.- date- "as found unsatisfactor b the authorized officer. (3) Under section- 27(2) of the Bihar Fire Sen ice Act. 20! 4. submit your own show a use within d as from the receipt of this notice, that ' Ii y not action related to re lie al etc. of that stuff or goods or encroachment be taken under section- 27 (2)(3)(1)(S) & (6) of I3iliar Fire Sen ice Act. 2014, Sub-Divisional Magistrate, FORM--W Order of Sub-Divisional Magistrate regarding confiscation, detention or removal in case of non-receipt of show cause served after default in removing probable factors of fire risk or show cause received found unsatisfactory. (tinder section- 27 oi[3ihar Fire Seivice Act. 2014. under rulc-I9 (1) ol l3Lhar Fire Service Rules. 2021 Letter no. - Office of the Sub-Divisional Magistrate Date - To. Sub:- Sir, (Name and address of owner! occupant of the building! premises/ panda!) Order for confiscation, dctention or removal of probable factors of fire risk, due to non receipt / finding unsatisfactory the show cause asked due to default in compliance of directions given by Fire Service for removal of probable factors of fire risk. With respect to the above mentioned reference and subject, it is informed that- (I) The premises/building under your ownership! occupancy! the panda! erected by you was verified by the DireetorlAuthorizedOf(icer, State Fire Service on date - at hours, regarding which a report has been submitted by him vide letter no.- date- During verification by him, the stuffs! object were found in the preniises!building tinder your ownership! occupancy/in the pandal erected by you, due to which there is probability of risk of fire incident in that preniises/buildingtpandal or nearby premises/ bui!ding!pandal or will be reason of obstacles in contro! of fire in case of fire incident. (2) Under the powers conferred vide sub-seclion- I of section- 27 of Bihar Fije Service Act, 20!4 and rule ! 9(a) of Bihar Fire Service Rules, 202! the direction was given by him to you for removing those stuffs or goods or encroachment immedialelv/ within hours/days. In addition to this, you were made acquainted with the report to be submitted to the Sub-Divisional Magistrate for !egal action under section 27 (2)(3)(4)(5) & (6)of Bihar Fire Service Act, 2014 in case of non-compliance of the above direction, but the above probable factors of fire incident! encroachment has not been removed by you. The petition submitted by you vide letter no.- date- was found unsatisfactory by the authorized officer. (3) You had been informed under section 27(2) of Bihar Fire Service Act. 2014. to submit your own show cause within das from the date of receipt of the notice that why not action elated to removal etc of that stuff or goods or encroachment be taLen under section- 27 (2)(3)(4)(5) & (6) of Bihar Fire Service Act. 2014. (4) The sIio; cause has not been filed by voulthe show cause submitted b' you has been Iburid uhlsat%sfactory after proper consideration. Due to keeping of factor of fire risk in that building/premises/pandal/encroachment (lone by you, the risk of life and property oF common people has arisen. (5) By using powers conferred under rule 19 (d) oF [3 liar Fire Service Ru!es, 2021. tinder section 27 (3) of Bihar Fire Ser ice Act. 2014. I (name of the authoruy (designation) hereby gis e order to seize/Leep detained tile fo!Iowing stuffs! goods! to remove the encroachment due to the above mentioned reasons:- SI jo. Place of seizure J Details of seized goods: ijovable properties (vfth amount nu nibe r) Reason of sIzt're or Lecpiug detained Sub-Divisional Magistrate. FORM--X Seizure list of probable Fire risk factors (Uiidersectioii-27 otl3iImrFiLeServiceAct. 201-!, uclderrL'le-IY (e)ot't3iha1' Fire SerUec Rules. 202!) I. Case no - 2. Place - 3. Date - 4, Time - 5. Name & address of the owner I occupant - 6. Name & address of the persons present - 7. Name & address of witnesses - (A) (a) Sri/smt (b)Sonl daughter! wife of (c) Resident of (d) Age (in year) - (e) Business - (B) (a) Sri/smt (b) Son! daughter/ wife of (c) Resident of (d) Age (in year) - (e) Business - We, the above written all the witnesses Sri/suit called by (designation) at the address (p!ace) of the building/premises/panda! are witnesses during seizure of certain movable properties or goods, which was kept by the owner/occupani in the premises/building/panda! and brought before us. That (The name and address of the office) has seized the following stuffs/goods, in our presence, which we found correct:- SI. no. Place of seizure List of seized movable properties/goods Amount Reason to seize & keeping detained The seizure ist was read before us and made clear before us and it "as bound correct in Our sigh I. Signature of the witnesses (Signature or the officer seizing goods) (I) (2) Received the copy of the seizure list Signature of the owner occupant FORM--v Notice for auction in case of non-removal of probable factors of Fire risk from place kept after seizure and default in claim Under section. 27 ofBihar Fire Sen ice Act. 2014. LLnder rLlle-I9 (1) olBihar Fire Sen ice Rules. 2021) Letter no,- / Office of the Sub-Divisional Magistrate Date- / To, Ref:- Letter no,- date- of this office. Subject:- Notice for action in case of default in removing and claiming the prohable factors olfire risk, Sir. With respect to the above mentioned reference and subject, it is to say that- (1 ) Certain goods! movable properties had been seized (from premises siluated on the address of the premises) on date- in case no.- date- tinder seizure list no.- date- under section-27 of Bihar Fire Service Act, 2014. (2) That movable properties/goods has been presently kept in (address the premises) (3) Now, (hat's hy I (Name) (designation) (office address) hereby instruct 'mu to remove Ihat goods/movable properties au any working day from hour to hours within days, at your own risk and cost. In case of default done in it by you, it viIl be understood that you have not any desire of claim on those goods/ movable properties and further, without giving any notice. the disposal of those goods! movable properties will he tone by public auction under sub section (5) of section-27 of Bihar Fire Service Act. 2014. (Signature) Date Name - Place Designation- FORM--Z Appeal by the affected person against auction of probable factors of Fire risk items. (Under section- 27 ol Hihar Fire Service Act. 2014. Llnder rule-! 9(g) ol Bihur Fire Service Rules 2021 To, The Appellate Authority (should be officer of senior rank from Sub-Divisional Magistrate) Ref:- Letter no.- date.- of Sub- Divisional Magistrate. Sub:- Appeal against the auction on default done inremoving or claiming the probable factors of rire risk. Sir, With respect to the above mentioned reference and subject, it is to say that- (I ) The certain goods! movable properties concerned with building! premises under me has been seized in case no date under seizure list no date under section-27 of the Bihar Fire Service Act. 2014. (2) The action of those movable properties! goods has been don&fixed to be done on date by the Sub-Divisional Magistrate (3) In this regard, I request for consideration on following facts and release of seized goods in my favour b cancellation of that auction procedure. (a) (b) (c) (d) a N a me!addrcss!d ate FORM--A-I Notice for appointment/ training of Fire Safety Officer. Inder sect on-29o1 Rihrr Fire Service Act. 2014. under rid e-20 (b ui I illar Fire Service Rti let 202 I . wider crion- 30 ,fBihur Fix-c Seniec Act. 2014. under rule-20 (c) a! 13ihur Fire Service Rules. 20211 Letter no.- / Office of the State Fire Officer-cum-Director, Bihar, Patna. Officeof the (Authorized Officer), Date - To, (Name and address of the owner/ occupants of the building, premises) Sub:- Regarding appointment/training of Fire Safety Officer. Sir, With respect to the above mentioned subject. it is to say that- (I) Your building! premises has basement and floors which is covered by the provisions of section 29 and 30 of the Bihar Fire Service Act, 20k. It has been expected from the osner of the building or occupant or their association for appointment of Fire Safety Officer under section 29 and the Fire Safety Officer to be trained under section 30. (2) The verification of your building! premises has been done by officer on date After verification, it has been found that the Fire Safety Officer has not been appointed in that building! premises. (3) After verification of your buildind premises it has been found that the Fire Safety Officer appointed in that building! premises is not properly trained. So that, I expect from you that the Fire Safety Officer should he appointed for that building! premises within 30 days from the date of receipt of the notice! should make available the certificate concerned with the appointed Fire Safety Officer being trained or the appointed untrained Fire Safety Officer should he adniitted for training in Fire Training Academy, Anandpur. Bihta, In case of not doing so. action for penalty will he done under section 31 of Bihar Fire Service Act. 2014 and rule 20(e)(f) of Bihar Fire Service Rules, 2021. Signature of Director! Authorized Officer, Name- Designation- Sea I- FORM--B-I Notice regarding imposition of penalty in case of default in appointment of Fire Safety Officer, in spite of notice served for appointment of Fire Safety Officer. (Vndcr scction-29 and 3! oF Rihar lire Service Act. 2014. u'ider rule-20 N) (eR fl of B ihar F ic Service Ru es. 202 I) Letter no.- I Office of the State Fire Officer-cum-Director, Bihar, Patna. Office of the (AuthorizedOfficer) Date- I To, (Name and address of the owner! occupants of the building, premises) Ref:- Letter no.- date- of this office. Sub:- Regarding non-compliance of the notice given, related to appointment / training of the Fire Safety Officer. Sir, With respect to the above mentioned reference and subject. ii is to say that:- (I) Your huildinglprernises is covered by the provisions of section 29 and 30 of the Bihar Fire Service Act. 2014. The appointment of Fire Safety Officer under section-29 of the Bihar Fire Service Act, 2014 arid the Fire Safety Officer being trained under section 30 of (he Act had been expected. (2) It had been directed lawfully on date- by the undersigned to appoint Fire Safety Officer in that building or for providing training to him, but the Fire Safety Officer has not been appointed in that building/premises by you tifl date, 'hile the period of 30 days had been fixed in the notice. (3) Neither any certificate has been made available, regarding being trained of Fire Safety Officer appointed in that building/premises nor has been admitted for training in Fire Training Academy. Bihta, within the stipulated period, by you. (4) Action to be done for penalty under section 31 of Biliar Fire Service Act. 2014 and rule-20 (e) (f) of Bihar Fire Service Rules, 2021. in case of non-compliance of the above direelion had been mentioned in the notice. So. submit show cause thai why not action should be done for recovery of prescribed penalty under rule 20 (d)(e)(t) of Bihar Fire Service Rules, 2021 under section 31 of I3ihar Fire Service Act, 2014 due to non-compliance of notice served under rule 20 (h)(c) of Biliar Fire Service Rules. 2021. under section 29 and 30 of Biliar Fire Service Act. 2014. In case of non-receipt of your show cause, it will be understood that you have nothing to say regarding this arid aclion for recovery of penalty will be started. Signature ofDireetor/ AuthorizedOfflce r Name- Designation- Sea I- FORM--C-i Notice for Fire Audit of Building or Premises (Undcrscctiori-33and 43(I) olI3iIiar Eii-eScrvcAct. 2014. under rulc-22 (a) ofIflIiar Hrc Scrvice Ru]cs.2021) I efter no.- / Office of the State Fire Officer- turn-Director, Bibar, Patna. Officeof the (Authorized Officer), Dale - To, (Name and address of the owner! occupant of the building, premises) Sub:- Notice for fire audit of the building or premises. Sir, With respect to the above mentioned subject, it is to say that- (I ) There are basements and floors in your buildiniz/ premises. (2) The fire audit of the building/ premises is necessary for verification of adequacy/inadequacy of the fire prevention and fire safety measures for the safety of life and property from fire disaster. (3) Under rule-22(a) of 13ihar Fire Service Rules, 202! under section 33 and 43(1) of Bihar Fire Service Act, 2014. the power for fire audit is conferred, for ensuring the fire prevention and fire safety measures, after entering in any type of building or premises beteeri sunrise to sunset, after notice of3 hours or at any time without notice in case of thinking of urgency. That's why. the fire audit of your building! premises will be done oil date at hours under the above mentioned coufelTed powers. Please. will retnain/presetit for fire audit yourself/vide your represenlative with necessary documcnts, Signature of Director / Authorized011icer Name- Designation- Seat- FORM-D-I Check points for Fire Audit of different categories of buildings and notice for necessary action regarding compliance of Fire Safety measures after the fire audit. (Under section- 33aud 43(2) (3) offlilmr Fire Service Act, 2014,under ru!e-22 bxe) (d} (g) (Ii) (i)U) oli3ihar 'ire Service Rules. 202 I) I Name of the building / address/a specially marked building for the identification: - 2. Year of construction of the building: - 3. No objection certificate (year of provisional / final / renewal) 4. Date of last fire audit: - 5. Type of building occupancy: - 6. Types of sub-occupancy: - 7. Height of the building (in meters) from ground level: - 8. Height of constructions in the surroundings of the building: - 9. Distance of the building from the electric lines (vertical and horizontal distance- in meters): - 10. The covered area of the building (in square meters)(of floors including basement and stilt) II. Number of floors: - 12. Number of basements: - 13. Number of stilts! ground floor: - 14. Number of blocks: - 15. Average occupants load per floor: - 16. Floor wise (area! number of occupants): - 17. Approach road! street (name and width): - (Minimum width of approach road should be 12 feet -20 feet) 18. Is this of hard surface and worthy for vehicle movement. 19. Is ending in the dead end. 20. Width of the approach! open space and width in front of the block and the other three sides set back:- 21. Vehicle acces all around the building and for movement at the angle of the building:- 22, Is there a minimum width and height of main entrance and cxii door to ensure easy entry and exit of fire fighting vehicles? 23. Car parking (site and number of vehicles): - 24, Projection in the open space (distance from four sides of the building): - 25. Number of entrance doors: - 26. Number of exit doors: - 27, Open space above the head in entrance /exit door: - 28. Internal stair (height /width of treads! height and number of risers/height of hand rail): - 29. Number of exit stair (height/width of treads/height and number ol' riscrs/ height of hand rail):- 30. Travel distance (distance from the farthesi poirii / distance from turning end of corridor to the stair): - 3 . Ramps (number/width !steep): - 32. Number and capacity of traveller lift: - 33. Number and capacity of service lift: - $4. Number and capacity of flre lift: - 35. Refugee Area (on which floor / area): - 36. Fire to" Cr (or which floor / area): - 37. Closed vcrtical open space: - 38. Corridor and route (according to he desi red idth / path not affected): - 39. Position of horizontal exit: - 40, llluminised exit symbol for exit: -

Previous and next

All provisions of Bihar Fire Service Act Rule 2021

Questions people ask

Is rule 39 of Bihar Fire Service Act Rule 2021 still in force?

No repeal of Bihar Fire Service Act Rule 2021 is recorded.