Rule 37, Tamil Nadu Combined Development and Building Rules, 2019: Planning Parameters of Institutional Buildings

Tamil Nadu Combined Development and Building Rules, 2019 - Rule 37

Text of rule 37

Planning Parameters of Institutional Buildings

37. Planning Parameters of Institutional Buildings.— Including nursery schools, Primary schools and religious buildings with floor area exceeding 300 sq.m. Secondary schools, Colleges, Higher Educational, Technical & Research Institutions, Students hostels & Dormitories, Research Institutions, Broadcasting, Telecasting & Telecommunication centers, Government & Quasi Government Offices, and Institutions, Government Archives, Museums, Art galleries and Public libraries, Foreign Missions, Consulates and Embassies. Sl.No. Description Continuous Building Areas Other areas 1 2 3 4 A. Minimum road width 7.20m Minimum 7.2m for schools upto higher secondary level and industrial training institutes. For others, min. 9 m B. Maximum Height 18.30m. C. 2.0 D. Minimum Setbacks Where Street Alignment/new road is prescribed, it shall be from that street alignment/narrow line. In the case of others, it shall be from the property boundary. (i) Front Setback 6m 6m (ii) Side Setback Nil 6m For schools - 2m (iii) Rear Setback Nil 6m For schools - 2m E. a) Structures permissible in the minimum prescribed Front set back, Side setback and Rear set back are given in the rule 28 b) In addition, Gate pillars, gopurams, and incidental structures (with height not exceeding 4m) such as servant room, cloak room, and watch man booth, cycle stand, Kitchen and toilets are permissible in these minimum prescribed setback spaces. F. Parking spaces shall be provided within the site conforming to standards prescribed in the Annexure - IV. G. Rainwater harvesting provisions as prescribed in the Annexure - XXII. H. The minimum width of corridor shall be as given in rule 42 I. The reservation of Land for community recreational purposes such as park or play ground required in these regulations shall be as given in the rule 41. J. The applicant not being a government department or agency shall deposit a sum at the rate of 50% of the infrastructure and amenity charges as a refundable non-interest earning security and earnest deposit. The deposit shall be refunded on completion of development as per the approved plan as certified by Competent Authority; if not, it would be forfeited. K. Special regulations for physically disabled stated in the rule 43 shall be adhered to. Normally Permissible FSI 40 TAMIL NADU GOVERNMENT GAZETTE EXTRAORDINARY Note: (i) In Continuous Building Area (CBA), there shall be atleast 1m wide internal passage from rear to front in ground level or ground floor, directly accessible to road. (ii) In the case of schools, the development shall confirm to the additional safety standards stated in the Annexure - XV. (iii) The maximum height of the building shall not exceed 18.30 metres provided water tanks, chimneys, Architectural features such as flag masts, gopurams, minarets, steeples and other ornamental structures which are not intended for human habitation may be permitted subject to a ceiling of 30.5 metres from ground level. (iv) In cases of Hospital Buildings with Ground Floor/Stilt Floor + First Floor and above and floor area exceeding 300 sq.m. in each floor, the special provisions for Hospital Buildings prescribed in Annexure – IX shall be adhered to.

Previous and next

All provisions of Tamil Nadu Combined Development and Building Rules, 2019

Questions people ask

Is rule 37 of Tamil Nadu Combined Development and Building Rules, 2019 still in force?

No repeal of Tamil Nadu Combined Development and Building Rules, 2019 is recorded.