Annexure 3, Rule-2017-The Central Government may, by notification in the official Gazette, make rules for carrying out the purposes of this Act.: ANNEXURE - 3
Rule-2017-The Central Government may, by notification in the official Gazette, make rules for carrying out the purposes of this Act. - Annexure 3
Text of annexure 3
ANNEXURE - 3
ANNEXURE - 3
Sanitation Requirements
Sanitation requirements for Shops and Commercial Offices
Sr. Sanitary Unit / Fittings For Personnel
No.
1 Water closet One for every 25 persons or part thereof exceeding 15
(including employees and customers). For female personnel 1
for every 15 persons or part thereof exceeding 10.
2 Drinking Water Fountain One for every 100 person with a minimum of one on each
floor.
3 Wash Basin One for every 25 persons or part thereof.
4 Urinals Nil upto 6 persons
1 for 7-20 persons
2 for 21-45 persons
3 for 46-70 persons
4 for 71-100 persons
From 101 to 200 add @ 3%;
For over 200 persons add @ 2.5%.
5 Cleaners‘ Sink One per floor minimum, preferably in or adjacent to sanitary
rooms.
Note: Number of customers for the purpose of the above calculation shall be the average number of persons in the
premises for a time interval of one hour during the peak period. For male-female calculation a ratio of 1: 1 may be
assumed.
Page | 104
Sanitary Requirements for Hotels
Sr. Sanitary Unit For Residential For non residential Staff
No. Public staff For male For female
1 Water Closet (W.C.) One per 8 Persons 1 for 1-15 2 for 1-12 persons
omitting occupants of persons 4 for 13-25
the attached water 2 for 16-35 persons
closet minimum of 2 if persons 6 for 26-40
both sexes are lodged 3 for 36-65 persons
persons 8 for 41-57
4 for 66-100 persons
person 10for 58-77
persons
12for78-100
persons
Add 1 for every 6
persons or part
thereof.
2 Ablution Taps One in each W.C. One in each W.C. One in each W.C.
3 Urinals Nil Nil upto 6 Nil
persons
1 for 7-20
persons
2 for 21-45
persons
3 for 40-70
persons
4 for 71-100
persons
4 Wash Basins One per 10 persons 1 for 15 persons 1 for 1-12
omitting each basin 2 for 16-35 2 for 13-25
installed in the room / persons 3 for 26-40
suite 3 for 36-65 4 for 41-57
persons
4 for 66-100
persons
5 Baths One per 10 persons, Nil Nil
less occupants of room
with bath in suite
6 Cleaner‘s Sinks One per 30 Bed rooms Nil Nil
(one per floor
minimum)
7 Kitchen Sink One in each Kitchen One in each One in each
Kitchen Kitchen
Page | 105
Contd: For Public Rooms
Sr. Sanitary Unit For Male For Female
No.
1 Water Closet One per 100 persons upto 400 Two for 100 persons upto 200
persons; for over 400 add at the persons;
rate of one per 250 persons or part over 200 add at the rate of one
thereof. per 100
persons or part thereof.
2 Ablution Taps One in each W.C. One in each W.C.
3 Urinals One for 50 persons or part il, upto 6 persons 1 for 7-20
thereof. persons
2 for 21-45 persons
3 for 46-70 persons
4 for 71-100 persons
4 Washbasins One per WC/Urinal One per WC
5 Kitchen Sink One in each Kitchen One in each Kitchen
6 Baths (showers) One per 10 persons
7 Cleaner‘s Sinks One per 30 Bed rooms (one per floor minimum)
Note:
i) It may be assumed that the two-thirds of the number are males and one- third females.
ii) One water tap with drainage arrangements shall be provided for every 50 persons or part thereof in the vicinity of
water closet and urinals.
Sanitation Requirements for Educational Occupancy
Sr. Sanitary Unit Boarding Institution Other Educational Institution
No.
For Boys For Girls
For Boys For Girls
1 Water Closet One for 8 boys One for 6 girls ne for 40 boys or One for 25
or part thereof or part thereof part thereof girls or part
thereof
2 Ablution Taps One in each One in each One in each W.C. One in each
W.C. W.C. W.C.
3 Urinals One per every _____ One per every 20 _____
25 pupils or part pupils or part
thereof thereof
4 Wash basins One for every 8 One for every 6 One for every 60 One for every
pupils or part pupils or part pupils or part 40
thereof thereof thereof pupils or part
thereof
5 Baths One for every 8 One for every 6 _____ _____
pupils or part pupils or part
thereof thereof
6 Baths One for every 50 One for every One for every 50 One for every
(showers) pupils or part 50 pupils or pupils or part 50
thereof part thereof pupils or part
thereof thereof
7 Cleaner‘s One per Floor One per Floor OneperFloor One per Floor
Sinks minimum minimum minimum minimum
Page | 106
Contd: Nursery Schools
Sr. Sanitary Unit Requirement
No.
1 Water Closet One for 15 boys, one for 6 girls
2 Ablution Taps One in each W.C.
3 Urinals One for 12 boys
4 Wash Basins One for every 15 pupils or part
thereof
5 Baths One bath per 40 pupils
6 Drinking Water Fountains One for every 50 pupils or part
thereof
7 Cleaner‘s Sink One per Floor minimum
Note:
1. One water tap with draining arrangements shall be provided for every 50 persons or part thereof, in the vicinity of
water closets and urinal.
2. For teaching staff, the schedule of sanitary units to be provided shall be the same as in case of office Buildings
Page | 107
Sanitation Requirements for Institutional (Medical) Occupancy- Hospital
Sr. Sanitary Unit Hospitals With Hospitals With outdoor Patient Wards
No. indoor Patient
Ward For Males & For Males For Females
females
1 Toilet Suite Private room upto 4 For upto 4 patients
(1WC+1Washbasin+ persons
1shower)
2 Water Closet (W.C.) One for every 8 beds One for every 100 O ne for every 25
or part thereof persons or part persons
thereof or part thereof
3 Ablution taps One in each W.C. One in each W.C. One in each W.C.
4 Wash Basins Two upto 30 bed; add one One for every 100 One for every 25
for every additional 30 persons or part thereof persons or part
beds; or part thereof thereof.
5 Baths with Shower One bath with shower for -- --
every 8 beds or part
thereof.
6 Bed pan washing One for each ward -- --
sink
7 Cleaner‘ Sinks One for each ward One per floor One per floor
minimum minimum
8 Kitchen sinks & dish One for each ward -- --
Washers (where
Kitchen is provided)
9 Urinals One for 30 beds One for every 50
(male wards) persons or part
thereof
10 Drinking water One for each ward One for 500 persons or part thereof
fountain
Page | 108
Contd: Administrative Buildings
Sr. Sanitary Unit For Males For Females
No.
1 Toilet Suite (1WC+1Washbasin+ For individual doctor‘s/officer‘s rooms
1shower)
2 Water Closet (W.C.) One for every 25 persons or part Two for every 25
thereof persons or part thereof
3 Ablution Taps. One in each W.C One in each W.C
4 Wash Basins One for every 25 persons or part One for every 25
thereof persons or part thereof
5 Baths with Shower One on each floor One on each floor
6 Cleaner‘s Sink One per floor minimum One per floor minimum
7 Kitchen sinks & dish One for each floor One for each floor
Washers (where Kitchen
is provided)
8 Urinals Nil upto 6 persons
1 for 7-20 persons
2 for 21-45 persons --
3 for 46-70 persons
4 for 71-100 persons
From 101 to 200 persons add at
the rate of 3%; for over 200
persons add at the rate of 2.5%.
9 Drinking water fountain One for 100 persons or part thereof
Sanitation Requirements for Institutional (Medical) Occupancy- (staff quarters and Hostels)
Sr. No. Sanitary Unit Doctor‟s Dormitories Nurses Hostel
For Male Staff For female staff
1 Water Closet (W.C.) One for 4 persons One for 2 One for 2
persons persons or
part thereof
Two for 13-25
2 Ablution Taps. One in each W.C. One in each One in each
W.C. W.C. O
3 Wash Basins One for every 8 One for every 8 One for every 8
persons or part persons or part persons or part
thereof thereof thereof
4 Baths with Shower One for every 4 One for every 4 One for every 4
persons or part persons or part persons or part
thereof thereof thereof
5 Cleaner‘s Sink One per floor One per floor One per floor
minimum minimum minimum
6 Drinking water One for 100 persons or part thereof One for 100
fountain persons or part
thereof
Page | 109
Sanitation Requirements for Governmental and Public Business Occupancy and Offices.
Sr. Sanitary Unit For Male Personnel For Female Personnel
No.
1 Water Closet One for 25 persons or part thereof Two for 15 persons or part
thereof
2 Ablution Taps One in each W.C. One in each W.C.
3 Urinals Nil upto 6 persons -------
1 for 7-20 persons
2 for 21-45 persons
3 for 46-70 persons
4 for 71-100 persons
From 101 to 200 add @ 3%;
For over 200 persons add @ 2.5%.
4 Wash basins One for every 25 persons or part One for every 25 persons or
thereof part thereof
5 Drinkingwater One for every 100 persons with a One for every 100 persons
fountains minimum of one on each floor with a
minimum of one on each
floor
6 Cleaner‘s Sinks One per floor minimum; preferably in -------
or adjacent to sanitary rooms.
7 Executive Room / Toilet Suite (1 WC, 1 washbasin, optional shower for 24 hr usages) Unit could
Conference Halls be common for Male/Female or separate depending on the number of user
of each facility
Note: One water tap with drainage arrangements shall be provided / 50 persons or part thereof in the vicinity.
Segregated sanitation facilities for Visitors in Public Buildings
Sr. Sanitary Unit For Male Personnel For Female Personnel
No.
1 Public toilet near Railway Stations (24x7) a) One for 100 users a) One for 50 users
a) Water Closet(W.C) b) One unit per 300-500 b) --
b) Urinals users c) One in each W.C.
c) Ablution taps c) One in each W.C.
2 Public Toilet near market place/offices a) One for 100 users a) One for 50 users
(for working hours) b) One unit per 200-300 b) --
a) Water Closet users c) One in each W.C.
b) Urinals c) One in each W.C.
c) Ablution taps
3 Public toilets near Public Buildings a) One for 100 users a) One for 50 users
a) Water Closet b) One unit per 200-300 b) --
b) Urinals users c) One in each W.C.
c) Ablution taps c) One in each W.C.
Page | 110
The recommended enclosure-sizes for different facilities at visitors‟ toilets
Sr. Description Optimum (mm) Minimum (mm)*
No.
1 Water Closet enclosures 900x1200 750x900
2 Urinals (divided by partition walls) 575x675 500x600
*In case of space constraint, the minimum sizes may be adopted
The recommended areas for different facilities at visitors‟ toilets
Sr. Sanitary Unit Dwelling with Dwelling without individual
No. individual conveniences
conveniences
1 Bath Room One provided One for every two tenement
with water tap
2 Water Closet (W.C.) One One for every two tenement
3 Sink (or Nahani) in One -----
the Floor
4 Water Tap One One with drainage arrangement in
each tenement
One in common bath rooms and
common water closet.
Note: Where only one water closet is provided in a dwelling, the bath and water closet shall be separately
accommodated.
Sanitation Requirements for Assembly Occupancy Buildings (Cinema, Theaters, Auditoria. Etc.)
Sr. No. Sanitary Unit For Public For Staff
For Male For female For Male For female
1 Water Closet One for 100 Four for 100 One for 15 Two for 1-
(W.C.) persons upto 400 persons upto persons. 12 persons.
persons. For 200 persons. Two for 16-35
over 400 For over 200 persons Four for 13-
persons, persons 25 persons
add at the rate add at the rate add at the
of 1 per 250 of 1 per 50 rate of 1 per
persons or part persons or part 6 persons or
thereof thereof part thereof
2 Ablution Taps. One in each W.C. One in each One in each One in each
W.C. W.C. W.C.
3 Urinals One for 50 ------ Nil upto --------
persons or part 6 persons
thereof One for 7-20
persons
Two for 21-45
persons
4 Wash Basins One for every One for every One for 1-15 One for 1-
Page | 111
200 persons or 200 persons or persons 12
part thereof part thereof Two for 16-35 persons
Two for 13-
25
persons
5 Drinking Water One for 100 persons or part thereof
Fountain
6 Cleaner‘s Sink One per floor
7 Shower/Bathing As per trade requirements
Note: i) One water tap with draining arrangements shall be provided for every 50 persons or part thereof in the vicinity
of water closets and urinals.
Sanitation Requirements for Assembly Buildings (Art, Galleries, Libraries and Museums).
Sr. Sanitary Unit For Public For Staff
No. For Male For female For Male For female
1 Water Closet ne for 200 persons Four for 100 One for 1-15 Two for 1-
(W.C.) upto 400 persons. persons upto persons. 12
For over 400 persons, 200 Two for 16-35 persons.
add at the rate of 1 persons. persons. Four for 13-
per 250 persons or For over 200 25
part thereof persons, add at persons, add
the at
rate of 1 per 50 the rate of 1
persons or part per 6
thereof persons.
2 Ablution Taps. One in each W.C. One in each One in each W.C. One in each
W.C. W.C.
3 Urinals One for 50 persons or ------ Nil upto 6 persons --------
part thereof One for 7-20
persons
Two for 21-45
persons
4 Wash Basins One for every 200 One for every One for 1-15 One for 1-
persons or part 200 persons 12 persons
thereof. For over 400 persons or part Two for 16-35 Two for 13-
persons, add at the thereof. For over 25
rate of 1 per 250 200 persons, add persons
persons or part at
thereof. the rate of 1 per
150
persons or part
thereof
5 Drinking Water One for 100 persons or part thereof
Fountain
6 Cleaner‘s Sink One per floor, minimum
7 Shower/Bathing As per trade requirements
Note: It may be assumed that two thirds of the numbers are males and one third females.
Page | 112
Sanitation Requirements for Restaurants
Sr. No. Sanitary Unit For Public For Staff
For Male For female For Male For female
1 Water Closet One per 50 seats One per 25 One for 15 Two per 1-
(W.C.) upto 200 seats upto 200 persons. 12 persons.
seats. For over seats. For over 2 for 16-35 4 for 13-25
200 seats, add 200 seats, add persons. persons.
at the rate of 1 at the rate of 1 3 for 36-65 6 for 26-40
per 100 seats per 50 seats or persons. persons.
or part thereof part 4 for 66-100 8 for 41-57
thereofthereof persons. persons.
10 for 58-77
persons.
12 for 78-
100
persons.
thereof
2 Ablution Taps. One in each W.C. One in each One in each One in each
W.C. W.C. W.C.
3 Urinals One for 50 ------ Nil upto 6 --------
persons or part persons.
thereof 1 for 7-20
persons.
2 for 21-45
persons.
3 for 46-70
persons.
4 for 71-100
persons.
4 Wash Basins One for every 200 persons or
part thereof
5 Kitchen Sinks & One per each Kitchen
Dish Washer
6 Cleaner‘s Sink One per floor
7 Service Sink One in the restaurant
Note:
i) It may be assumed that two thirds of the numbers are males and one-third females.
ii) One water tap with draining arrangements shall be provided for every 50 persons or part thereof in the vicinity of
water closets and urinal.
Page | 113
Sanitation Requirements for Factories
Sr. Sanitary Unit For Male Personnel For Female Personnel
No.
1 Water Closet 1 for 15 persons 2 for 1-12 persons
(W.C.) 2 for 16-35 persons 4 for 13-25 persons.
3 for 36-65 persons. 6 for 26-40 persons.
4 for 66-100 persons. 8 for 41-57 persons.
For 101 to 200 persons add at 10 for 58-77 persons.
rate of 3%. From over 200 12 for 78-100 persons.
persons, add at the rate of 2.5% For 101 to 200 persons, add at the
rate of 3%. From over 200 persons
add at the rate of 2%..
2 Ablution Taps. One in each W.C. One in each W.C.
3 Urinals Nil upto 6 persons ----------
1 for 7-20 persons
2 for 21-45 persons
3 for 46-70 persons
4 for 71-100 persons
From 101 to 200 persons add at
the rate of 3%; for over 200
persons add at the rate of 2.5%.
4 Washing Taps with One for every 25 persons or part thereof
draining
arrangement
5 Drinking Water One for every 100 persons with a minimum of one on each floor
Fountains
6 Baths Preferably As required for particular trade or occupation
Showers
7 Emergency shower One per every shop floor per 500 person
and eye wash
fountain
Note:
i) For many trades of a dirty or dangerous character, more extensive provisions are required.
ii) One water tap with draining arrangement shall be provided for every 50 persons or part thereof in the
vicinity of water closet and urinal.
iii) Creche where provided shall be fitted with water closets (One for 10 persons or part thereof), wash basins
(1 for 15 persons or part thereof) and drinking water tap with drinking arrangement for every 50 persons
or part thereof.
Page | 114
Sanitary Requirements for Large Stations and Airports.
Sr. Place W.C. for Males W.C. for Females Urinals for Males
No. only
1 Junction Stations, 3 for first 1000 8 for first 1000 4 for every 1000
Intermediate Stations persons, add 1 for persons, add 1 for person,
and Substations subsequent 1000 every additional 1000 add 1 for every
persons or part persons or part additional 1000
thereof. thereof. persons
or part thereof.
2 Terminal Stations and for first 1000 persons 6 for every 1000
Bus Terminals and 1 for 10 for every 1000 person
every additional person and 1 for every and 1 for every
1000 persons or part additional 1000 additional 1000
thereof. persons or part persons
thereof. or part thereof.
3 Domestic Airports 2* 16 1 per 40 persons or
Minimum. 5 30 part
For 200 persons 9 40 thereof.
For 400 persons 12 52
For 600 persons 16 58
For 800 persons 18
For 1000 persons
4 International Airports 6 20 1 per 40 persons or
For 200 persons 12 40 part thereof.
For 600 persons 18 58
For 1000 persons
Note:
i) Provision for wash basins, baths including shower stalls, shall be in accordance with part IX Section 2-Drainage and
Sanitation of National Building Code of India.
* At least one Indian style water closet shall be provided in each toilet. Assume 60 % males and 40 % females in any
area.
* At least 50 % of female WCs may be Indian pan and 50% EWC.
General Standards/Guidelines for Public Toilets in Public Area.
Public Toilet On roads and for open areas: At every 1 km, including in parks, plaza, open air theatre,
Swimming area, car parks, and fuel stations. Toilets shall be disabled-friendly and in 50-
50 ratio (M/F). Provision may be made as for Public Rooms (Table 4.10 Contd)
Signage Signboards on main streets shall give directions and mention the distance to reach the
nearest public convenience. Toilets shall have multi-lingual signage for the convenience
of visitors. Helpline number shall be pasted on all toilets for complaints/queries.
Modes And use or free. In pay and use toilets entry is allowed on payment to the attendant or by
inserting coin and user gets 15 minutes.
Maintenance/ The toilet should have both men and women attendants. Alternatively automatic cleaning
Cleaning cycle covering flush, toilet bowl, seat, hand wash basin, disinfecting of floor and
complete drying after each use can be adopted, which takes 40 seconds.
Public toilet shall be open 24 hours.