Rule 18, Bio-Medical Waste Management Rules, 2016.: Liability of the occupier, operator of a facility
Bio-Medical Waste Management Rules, 2016. - Rule 18
Text of rule 18
Liability of the occupier, operator of a facility
18. Liability of the occupier, operator of a facility.- (1) The occupier or an operator of a common
bio-medical waste treatment facility shall be liable for all the damages caused to the environment or the
public due to improper handling of bio- medical wastes.
(2) The occupier or operator of common bio-medical waste treatment facility shall be liable for action
under section 5 and section 15 of the Act, in case of any violation.
SCHEDULE I
[See rules 3 (e), 4(b), 7(1), 7(2), 7(5), 7 (6) and 8(2)]
Part-1
Biomedical wastes categories and their segregation, collection, treatment, processing and
disposal options
Category Type of Waste Type of Bag or
Container to be
used
Treatment and Disposal options
(1) (2) (3) (4)
Yellow (a) Human Anatomical
Waste:
Human tissues, organs,
body parts and fetus
below the viability
period (as per the
Medical Termination of
Pregnancy Act 1971,
amended from time to
time).
Yellow coloured
non-chlorinated
plastic bags
Incineration or Plasma Pyrolysis or
deep burial*
(b)Animal Anatomical
Waste :
Experimental animal
carcasses, body parts,
organs, tissues,
including the waste
generated from
animals used in
experiments or testing
in veterinary hospitals
or colleges or animal
houses.
(c) Soiled Waste:
Items contaminated
with blood, body fluids
like dressings, plaster
casts, cotton swabs and
Incineration or Plasma Pyrolysis or
deep burial*
In absence of above facilities,
autoclaving or micro-waving/
12
bags containing residual
or discarded blood and
blood components.
hydroclaving followed by shredding or
mutilation or combination of
sterilization and shredding. Treated
waste to be sent for energy recovery.
(d) Expired or
Discarded Medicines:
Pharmaceutical waste
like antibiotics,
cytotoxic drugs
including all items
contaminated with
cytotoxic drugs along
with glass or plastic
ampoules, vials etc.
Yellow coloured
non-chlorinated
plastic bags or
containers
Expired 'cytotoxic drugs and items
contaminated with cytotoxic drugs to be
returned back to the manufacturer or
supplier for incineration at temperature
>1200 0C or to common bio-medical
waste treatment facility or hazardous
waste treatment, storage and disposal
facility for incineration at >12000C Or
Encapsulation or Plasma Pyrolysis at
>12000C.
All other discarded medicines shall be
either sent back to manufacturer or
disposed by incineration.
(e) Chemical Waste:
Chemicals used in
production of biological
and used or discarded
disinfectants.
Yellow coloured
containers or
non-chlorinated
plastic bags
Disposed of by incineration or Plasma
Pyrolysis or Encapsulation in
hazardous waste treatment, storage and
disposal facility.
(f) Chemical Liquid
Waste :
Liquid waste generated
due to use of chemicals
in production of
biological and used or
discarded disinfectants,
Silver X-ray film
developing liquid,
discarded Formalin,
infected secretions,
aspirated body
fluids, liquid from
laboratories and floor
washings, cleaning,
house-keeping and
disinfecting activities
etc.
Separate
collection
system leading
to effluent
treatment system
After resource recovery, the chemical
liquid waste shall be pre-treated before
mixing with other wastewater. The
combined discharge shall conform to
the discharge norms given in Schedule-
III.
(g) Discarded linen,
mattresses, beddings
contaminated with
blood or body fluid.
Non-chlorinated
yellow plastic
bags or suitable
packing material
Non- chlorinated chemical disinfection
followed by incineration or Plazma
Pyrolysis or for energy recovery.
In absence of above facilities, shredding
or mutilation or combination of
sterilization and shredding. Treated
waste to be sent for energy recovery or
incineration or Plazma Pyrolysis.
13
(h) Microbiology,
Biotechnology and
other clinical
laboratory waste:
Blood bags, Laboratory
cultures, stocks or
specimens of micro
organisms, live or
attenuated vaccines,
human and animal cell
cultures used in
research, industrial
laboratories, production
of biological, residual
toxins, dishes and
devices used for
cultures.
Autoclave safe
plastic bags or
containers
Pre-treat to sterilize with non
chlorinated chemicals on-site as per
National AIDS Control Organisation or
World Health Organisation guidelines
thereafter for Incineration.
Red Contaminated Waste
(Recyclable)
(a) Wastes generated
from disposable items
such as tubing, bottles,
intravenous tubes and
sets, catheters, urine
bags, syringes (without
needles and fixed needle
syringes) and
vaccutainers with their
needles cut) and gloves.
Red coloured
non-chlorinated
plastic bags or
containers
Autoclaving or micro-waving/
hydroclaving followed by shredding or
mutilation or combination of
sterilization and shredding. Treated
waste to be sent to registered or
authorized recyclers or for energy
recovery or plastics to diesel or fuel oil
or for road making, whichever is
possible.
Plastic waste should not be sent to
landfill sites.
White
(Translucent)
Waste sharps
including Metals:
Needles, syringes with
fixed needles, needles
from needle tip cutter or
burner, scalpels, blades,
or any other
contaminated sharp
object that may cause
puncture and cuts. This
includes both used,
discarded and
contaminated metal
sharps
Puncture proof,
Leak proof,
tamper proof
containers
Autoclaving or Dry Heat Sterilization
followed by shredding or mutilation or
encapsulation in metal container or
cement concrete; combination of
shredding cum autoclaving; and sent for
final disposal to iron foundries (having
consent to operate from the State
Pollution Control Boards or Pollution
Control Committees) or sanitary
landfill or designated concrete waste
sharp pit.
Blue (a) Glassware:
Broken or discarded and
contaminated glass
including medicine vials
and ampoules except
those contaminated with
cytotoxic wastes.
Cardboard boxes
with blue
colored marking
Disinfection (by soaking the washed
glass waste after cleaning with
detergent and Sodium Hypochlorite
treatment) or through autoclaving or
microwaving or hydroclaving and then
sent for recycling.
14
(b) Metallic Body
Implants
Cardboard boxes
with blue
colored marking
*Disposal by deep burial is permitted only in rural or remote areas where there is no access to
common bio-medical waste treatment facility. This will be carried out with prior approval from the
prescribed authority and as per the Standards specified in Schedule-III. The deep burial facility
shall be located as per the provisions and guidelines issued by Central Pollution Control Board
from time to time.
Part -2
(1) All plastic bags shall be as per BIS standards as and when published, till then the prevailing Plastic
Waste Management Rules shall be applicable.
(2) Chemical treatment using at least 10% Sodium Hypochlorite having 30% residual chlorine for
twenty minutesor any other equivalent chemical reagent that should demonstrate Log104 reduction
efficiency for microorganisms as given in Schedule- III.
(3) Mutilation or shredding must be to an extent to prevent unauthorized reuse.
(4) There will be no chemical pretreatment before incineration, except for microbiological, lab and
highly infectious waste.
(5) Incineration ash (ash from incineration of any bio-medical waste) shall be disposed through
hazardous waste treatment, storage and disposal facility, if toxic or hazardous constituents are
present beyond the prescribed limits as given in the Hazardous Waste (Management, Handling and
Transboundary Movement) Rules, 2008 or as revised from time to time.
(6) Dead Fetus below the viability period (as per the Medical Termination of Pregnancy Act 1971,
amended from time to time) can be considered as human anatomical waste. Such waste should be
handed over to the operator of common bio-medical waste treatment and disposal facility in yellow
bag with a copy of the official Medical Termination of Pregnancy certificate from the Obstetrician
or the Medical Superintendent of hospital or healthcare establishment.
(7) Cytotoxic drug vials shall not be handed over to unauthorised person under any circumstances.
These shall be sent back to the manufactures for necessary disposal at a single point. As a second
option, these may be sent for incineration at common bio-medical waste treatment and disposal
facility or TSDFs or plasma pyrolys is at temperature >1200 0C.
(8) Residual or discarded chemical wastes, used or discarded disinfectants and chemical sludge can be
disposed at hazardous waste treatment, storage and disposal facility. In such case, the waste should
be sent to hazardous waste treatment, storage and disposal facility through operator of common
bio-medical waste treatment and disposal facility only.
15
(9) On-site pre-treatment of laboratory waste, microbiological waste, blood samples, blood bags
should be disinfected or sterilized as per the Guidelines of World Health Organisation or National
AIDS Control Organisation and then given to the common bio-medical waste treatment and
disposal facility.
(10) Installation of in-house incinerator is not allowed. However in case there is no common biomedical
facility nearby, the same may be installed by the occupier after taking authorisation from the State
Pollution Control Board.
(11) Syringes should be either mutilated or needles should be cut and or stored in tamper proof, leak
proof and puncture proof containers for sharps storage. Wherever the occupier is not linked to a
disposal facility it shall be the responsibility of the occupier to sterilize and dispose in the manner
prescribed.
(12) Bio-medical waste generated in households during healthcare activities shall be segregated as per
these rules and handed over in separate bags or containers to municipal waste collectors. Urban
Local Bodies shall have tie up with the common bio-medical waste treatment and disposal facility
to pickup this waste from the Material Recovery Facility (MRF) or from the house hold directly,
for final disposal in the manner as prescribed in this Schedule.
SCHEDULE II
[See rule 4(t), 7(1) and 7(6)]
STANDARDS FOR TREATMENT AND DISPOSAL OF
BIO-MEDICALWASTES
1. STANDARDS FOR INCINERATION.-
All incinerators shall meet the following operating and emission standards-
A. Operating Standards
1) . Combustion efficiency (CE) shall be at least 99.00%.
2) . The Combustion efficiency is computed as follows:
%C02
C.E. = ------------ X 100
%C02 + % CO
3) . The temperature of the primary chamber shall be a minimum of 800 0C and the secondary
chamber shall be minimum of 10500C + or - 500C.
4) . The secondary chamber gas residence time shall be at least two seconds.
B. Emission Standards
16
Sl.
No.
Parameter Standards
(1) (2) (3) (4)
Limiting concentration
in mg Nm3 unless
stated
Sampling Duration in minutes,
unless stated
1. Particulate matter 50 30 or 1NM3 of sample volume,
whichever is more
2. Nitrogen Oxides NO and
NO2 expressed asNO2
400 30 for online sampling or grab
sample
3. HCl 50 30 or 1NM3 of sample volume,
whichever is more
4. Total Dioxins and Furans 0.1ngTEQ/Nm3 (at 11%
O2)
8 hours or 5NM3 of sample volume,
whichever is more
5. Hg and its compounds 0.05 2 hours or 1NM3 of sample volume,
whichever is more
C. Stack Height: Minimum stack height shall be 30 meters above the ground and shall be attached with
the necessary monitoring facilities as per requirement of monitoring of ‘general parameters' as notified
under the Environment (Protection) Act, 1986 and in accordance with the Central Pollution Control
Board Guidelines of Emission Regulation Part-III.
Note:
(a) The existing incinerators shall comply with the above within a period of two years from the date of
the notification.
(b) The existing incinerators shall comply with the standards for Dioxins and Furans of 0.1ngTEQ/Nm3,
as given below within two years from the date of commencement of these rules.
(c) All upcoming common bio-medical waste treatment facilities having incineration facility or captive
incinerator shall comply with standards for Dioxins and Furans.
(d) The existing secondary combustion chambers of the incinerator and the pollution control devices shall
be suitably retrofitted, if necessary, to achieve the emission limits.
(e) Wastes to be incinerated shall not be chemically treated with any chlorinated disinfectants.
(f) Ash from incineration of biomedical waste shall be disposed of at common hazardous waste treatment
and disposal facility. However, it may be disposed of in municipal landfill, if the toxic metals in
incineration ash are within the regulatory quantities as defined under the Hazardous Waste
(Management and Handling and Transboundary Movement) Rules, 2008 as amended from time to
time.
(g) Only low Sulphur fuel like Light Diesel Oil or Low Sulphur Heavy Stock or Diesel, Compressed
Natural Gas, Liquefied Natural Gas or Liquefied Petroleum Gas shall be used as fuel in the
incinerator.
17
(h) The occupier or operator of a common bio-medical waste treatment facility shall monitor the stack
gaseous emissions (under optimum capacity of the incinerator) once in three months through a
laboratory approved under the Environment (Protection) Act, 1986 and record of such analysis
results shall be maintained and submitted to the prescribed authority. In case of dioxins and furans,
monitoring should be done once in a year.
(i) The occupier or operator of the common bio-medical waste treatment facility shall install continuous
emission monitoring system for the parameters as stipulated by State Pollution Control Board or
Pollution Control Committees in authorisation and transmit the data real time to the servers at State
Pollution Control Board or Pollution Control Committees and Central Pollution Control Board.
(j) All monitored values shall be corrected to 11% Oxygen on dry basis.
(k) Incinerators (combustion chambers) shall be operated with such temperature, retention time and
turbulence, as to achieve Total Organic Carbon content in the slag and bottom ashes less than 3% or
their loss on ignition shall be less than 5% of the dry weight.
(l) The occupier or operator of a common bio-medical waste incinerator shall use combustion gas
analyzer to measure CO2, CO and O2.
2. Operating and Emission Standards for Disposal by Plasma Pyrolysis or Gasification:
A. Operating Standards:
All the operators of the Plasma Pyrolysis or Gasification shall meet the following operating and emission
standards:
1) Combustion Efficiency (CE) shall be at least 99.99%.
2) The Combustion Efficiency is computed as follows.
% CO2 C.E =
.................................. X 100
(% CO2 + % CO)
3) The temperature of the combustion chamber after plasma gasification shall be 1050 ± 50 o C with
gas residence time of at least 2(two) second, with minimum 3 % Oxygen in the stack gas.
4) The Stack height should be minimum of 30 m above ground level and shall be attached with the
necessary monitoring facilities as per requirement of monitoring of ‘general parameters' as
notified under the Environment (Protection) Act, 1986 and in accordance with the CPCB
Guidelines of Emission Regulation Part-III.
B. Air Emission Standards and Air Pollution Control Measures
(i) Emission standards for incinerator, notified at Sl No.1 above in this Schedule, and revised from
time to time, shall be applicable for the Plasma Pyrolysis or Gasification also.
18
(ii) Suitably designed air pollution control devices shall be installed or retrofitted with the ‘Plasma
Pyrolysis or Gasification to achieve the above emission limits, if necessary.
(iii) Wastes to be treated using Plasma Pyrolysis or Gasification shall not be chemically treated with
any chlorinated disinfectants and chlorinated plastics shall not be treated in the system.
C. Disposal of Ash Vitrified Material: The ash or vitrified material generated from the ‘Plasma
Pyrolysis or Gasification shall be disposed off in accordance with the Hazardous Waste (Management,
Handling and Transboundary Movement) Rules 2008 and revisions made thereafter in case the
constituents exceed the limits prescribed under Schedule II of the said Rules or else in accordance with
the provisions of the Environment (Protection) Act, 1986, whichever is applicable.
3. STANDARDS FOR AUTOCLAVING OF BIO-MEDICAL WASTE.-
The autoclave should be dedicated for the purposes of disinfecting and treating bio-medical
waste.
(1) When operating a gravity flow autoclave, medical waste shall be subjected to:
(i) a temperature of not less than 121° C and pressure of 15 pounds per square inch (psi) for an
autoclave residence time of not less than 60 minutes; or
(ii) a temperature of not less than 135° C and a pressure of 31 psi for an autoclave residence time of
not less than 45 minutes; or
(iii) a temperature of not less than 149° C and a pressure of 52 psi for an autoclave residence time
of not less than 30 minutes.
(2) When operating a vacuum autoclave, medical waste shall be subjected to a minimum of three
pre-vacuum pulse to purge the autoclave of all air. The air removed during the pre-vacuum, cycle should
be decontaminated by means of HEPA and activated carbon filtration, steam treatment, or any other
method to prevent release of pathogen. The waste shall be subjected to the following:
(i) a temperature of not less than 121°C and pressure of 15 psi per an autoclave residence time of
not less than 45 minutes; or
(ii) a temperature of not less than 135°C and a pressure of 31 psi for an autoclave residence time of
not less than 30 minutes;
(3) Medical waste shall not be considered as properly treated unless the time, temperature and
pressure indicators indicate that the required time, temperature and pressure were reached during the
autoclave process. If for any reasons, time temperature or pressure indicator indicates that the required
temperature, pressure or residence time was not reached, the entire load of medical waste must be
autoclaved again until the proper temperature, pressure and residence time were achieved.
19
(4) Recording of operational parameters: Each autoclave shall have graphic or computer recording
devices which will automatically and continuously monitor and record dates, time of day, load
identification number and operating parameters throughout the entire length of the autoclave cycle.
(5) Validation test for autoclave: The validation test shall use four biological indicator strips, one shall
be used as a control and left at room temperature, and three shall be placed in the approximate center of
three containers with the waste. Personal protective equipment (gloves, face mask and coveralls) shall be
used when opening containers for the purpose of placing the biological indicators. At least one of the
containers with a biological indicator should be placed in the most difficult location for steam to
penetrate, generally the bottom center of the waste pile. The occupier or operator shall conduct this test
three consecutive times to define the minimum operating conditions. The temperature, pressure and
residence time at which all biological indicator vials or strips for three consecutive tests show complete
inactivation of the spores shall define the minimum operating conditions for the autoclave. After
determining the minimum temperature, pressure and residence time, the occupier or operator of a
common biomedical waste treatment facility shall conduct this test once in three months and records in
this regard shall be maintained.
(6) Routine Test: A chemical indicator strip or tape that changes colour when a certain temperature is
reached can be used to verify that a specific temperature has been achieved. It may be necessary to use
more than one strip over the waste package at different locations to ensure that the inner content of the
package has been adequately autoclaved. The occupier or operator of a common bio medical waste
treatment facility shall conduct this test during autoclaving of each batch and records in this regard shall
be maintained.
(7) Spore testing: The autoclave should completely and consistently kill the approved biological
indicator at the maximum design capacity of each autoclave unit. Biological indicator for autoclave shall
be Geobacillusstearothermophilus spores using vials or spore Strips; with at least 1X106 spores. Under no
circumstances will an autoclave have minimum operating parameters less than a residence time of 30
minutes, a temperature less than 121o C or a pressure less than 15 psi. The occupier or operator of a
common bio medical waste treatment and disposal facility shall conduct this test at least once in every
week and records in this regard shall be maintained.
4. STANDARDS OF MICROWAVING.-
(1) Microwave treatment shall not be used for cytotoxic, hazardous or radioactive wastes,
contaminated animal carcasses, body parts and large metal items.
(2) The microwave system shall comply with the efficacy test or routine tests and a performance
guarantee may be provided by the supplier before operation of the limit.
(3) The microwave should completely and consistently kill the bacteria and other pathogenic
organisms that are ensured by approved biological indicator at the maximum design capacity of each
microwave unit. Biological indicators for microwave shall be Bacillus atrophaeusspores using vials or
spore strips with at least 1 x 104sporesper detachable strip. The biological indicator shall be placed with
waste and exposed to same conditions as the waste during a normal treatment cycle.
20
5. STANDARDS FOR DEEP BURIAL.- (1) A pit or trench should be dug about two meters deep.
It should be half filled with waste, then covered with lime within 50 cm of the surface, before filling the
rest of the pit with soil.
(2) It must be ensured that animals do not have any access to burial sites. Covers of galvanised iron
or wire meshes may be used.
(3) On each occasion, when wastes are added to the pit, a layer of 10 cm of soil shall be added to
cover the wastes.
(4) Burial must be performed under close and dedicated supervision.
(5) The deep burial site should be relatively impermeable and no shallow well should be close to the
site.
(6) The pits should be distant from habitation, and located so as to ensure that no contamination
occurs to surface water or ground water. The area should not be prone to flooding or erosion.
(7) The location of the deep burial site shall be authorised by the prescribed authority.
(8) The institution shall maintain a record of all pits used for deep burial.
(9) The ground water table level should be a minimum of six meters below the lower level of deep
burial pit.
6. STANDARDS FOR EFFICACY OF CHEMICAL DISINFECTION
Microbial inactivation efficacy is equated to “Log10 kill” which is defined as the difference
between the logarithms of number of test microorganisms before and after chemical treatment. Chemical
disinfection methods shall demonstrate a 4 Log10 reduction or greater for Bacillus Subtilis (ATCC
19659) in chemical treatment systems.
7. STANDARDS FOR DRY HEAT STERILIZATION
Waste sharps can be treated by dry heat sterilization at a temperature not less than 1850C, at least
for a residence period of 150 minutes in each cycle, which sterilization period of 90 minutes. There
should be automatic recording system to monitor operating parameters.
(i) Validation test for Shaprs sterilization unit
Waste shaprs sterilization unit should completely and consistently kill the biological indicator
GeobacillusStearothermophillus or Bacillus Atropheausspoers using vials with at least log10 6 spores per
ml. The test shall be carried out once in three months
(ii) Routine test
21
A chemical indicator strip or tape that changes colour when a certain temperature is reached can
be used to verify that a specific temperature has been achieved. It may be necessary to use more than one
strip over the waste to ensure that the inner content of the sharps has been adequately disinfected. This
test shall be performed once in week and records in this regard shall be maintained.
8. STANDARDS FOR LIQUID WASTE.-
(1) The effluent generated or treated from the premises of occupier or operator of a common bio
medical waste treatment and disposal facility, before discharge into the sewer should conform to the
following limits
PARAMETERS PERMISSIBLE LIMITS
pH
Suspended solids
Oil and grease
BOD
COD
Bio-assay test
6.5-9.0
100 mg/l
10 mg/l
30 mg/l
250 mg/l
90% survival of fish after 96 hours in 100% effluent.
(2) Sludge from Effluent Treatment Plant shall be given to common bio-medical waste treatment facility
for incineration or to hazardous waste treatment, storage and disposal facility for disposal.
Schedule III
[See rule 6 and 9(3)]
List of Prescribed Authorities and the Corresponding Duties
Sl.
No
Authority
(2)
Corresponding Duties
(3)
(1)
1 Ministry of Environment, Forest
and Climate Change, Government
of India
(i) Making Policies concerning bio-medical waste
Management in the Country including notification
of Rules and amendments to the Rules as and
when required.
(ii) Providing financial assistance for training and
awareness programmes on bio-medical waste
management related activities to for the State
Pollution Control Boards or Pollution Control
Committees.
(iii) Facilitating financial assistance for setting up or
up-gradation of common bio-medical waste
treatment facilities.
(iv) Undertake or support operational research and
assessment with reference to risks to environment
and health due to bio-medical waste and
22
previously unknown disposables and wastes from
new types of equipment.
(v) Constitution of Monitoring Committee for
implementation of the rules.
(vi) Hearing Appeals and give decision made in Form-
V against order passed by the prescribed
authorities.
(vii) Develop Standard manual for Trainers and
Training.
(viii) Notify the standards or operating parameters for
new technologies for treatment of bio medical
waste other than those listed in Schedule- I.
2 Central or State Ministry of Health
and Family Welfare, Central
Ministry for Animal Husbandry
and Veterinary or State Department
of Animal Husbandry and
Veterinary.
(i) Grant of license to health care facilities or nursing
homes or veterinary establishments with a condition
to obtain authorisation from the prescribed authority
for bio-medical waste management.
(ii) Monitoring, Refusal or Cancellation of license for
health care facilities or nursing homes or veterinary
establishments for violations of conditions of
authorisation or provisions under these Rules.
(iii) Publication of list of registered health care facilities
with regard to bio-medical waste generation,
treatment and disposal.
(iv) Undertake or support operational research and
assessment with reference to risks to environment
and health due to bio-medical waste and previously
unknown disposables and wastes from new types of
equipment.
(v) Coordinate with State Pollution Control Boards for
organizing training programmes to staff of health
care facilities and municipal workers on bio-medical
waste.
(vi) Constitution of Expert Committees at National or
State level for overall review and promotion of clean
or new technologies for bio-medical waste
management.
23
(vii) Organizing or Sponsoring of trainings for the
regulatory authorities and health care facilities on
bio-medical waste management related activities.
(viii) Sponsoring of mass awareness campaigns in
electronic media and print media.
3 Ministry of Defence (i) Grant and renewal of authorisation to Armed Forces
health care facilities or common bio-medical waste
treatment facilities (Rule 9).
(ii) Conduct training courses for authorities dealing with
management of bio-medical wastes in Armed Forces
health care facilities or treatment facilities in
association with State Pollution Control Boards or
Pollution Control Committees or Central Pollution
Control Board or Ministry of Environment, Forest
and Climate Change.
(iii) Publication of inventory of occupiers and bio
medical waste generation from Armed Forces health
care facilities or occupiers
(iv) Constitution of Advisory Committee for
implementation of the rules.
(v) Review of management of bio-medical waste
generation in the Armed Forces health care facilities
through its Advisory Committee (Rule 11).
(vi) Submission of annual report to Central Pollution
Control Board within the stipulated time period (Rule
13).
4. Central Pollution Control Board (i) Prepare Guidelines on bio-medical waste
Management and submit to the Ministry of
Environment, Forest and Climate Change.
(ii) Co-ordination of activities of State Pollution Control
Boards or Pollution Control Committees on bio
medical waste.
(iii) Conduct training courses for authorities dealing with
management of bio-medical waste.
(iv) Lay down standards for new technologies for
24
treatment and disposal of bio-medical waste (Rule 7)
and prescribe specifications for treatment and
disposal of bio-medical wastes (Rule 7).
(v) Lay down Criteria for establishing common bio
medical waste treatment facilities in the Country.
(vi) Random inspection or monitoring of health care
facilities and common bio-medical waste treatment
facilities.
(vii) Review and analysis of data submitted by the State
Pollution Control Boards on bio-medical waste and
submission of compiled information in the form of
annual report along with its observations to Ministry
of Environment, Forest and Climate Change .
(viii) Inspection and monitoring of health care facilities
operated by the Director General, Armed Forces
Medical Services (Rule 9).
(ix) Undertake or support research or operational
research regarding bio-medical waste.
5. State Government of Health or
Union Territory Government or
Administration
(i) To ensure implementation of the rule in all health
care facilities or occupiers.
(ii) Allocation of adequate funds to Government health
care facilities for bio-medical waste management.
(iii) Procurement and allocation of treatment equipments
and make provision for consumables for bio-medical
waste management in Government health care
facilities.
(iv) Constitute State or District Level Advisory
Committees under the District Magistrate or
Additional District Magistrate to oversee the bio
medical waste management in the Districts.
(v) Advise State Pollution Control Boards or Pollution
Control Committees on implementation of these
Rules.
(vi) Implementation of recommendations of the Advisory
Committee in all the health care facilities.
25
6. State Pollution Control Boards or
Pollution Control Committees
(i) Inventorisation of Occupiers and data on bio-medical
waste generation, treatment & disposal.
(ii) Compilation of data and submission of the same in
annual report to Central Pollution Control Board
within the stipulated time period.
(iii) Grant and renewal, suspension or refusal cancellation
or of authorisation under these rules (Rule 7, 8 and
10).
(iv) Monitoring of compliance of various provisions and
conditions of authorisation.
(v) Action against health care facilities or common bio
medical waste treatment facilities for violation of
these rules (Rule 18).
(vi) Organizing training programmes to staff of health
care facilities and common bio-medical waste
treatment facilities and State Pollution Control
Boards or Pollution Control Committees Staff on
segregation, collection, storage, transportation,
treatment and disposal of bio-medical wastes.
(vii) Undertake or support research or operational research
regarding bio-medical waste management.
(viii) Any other function under these rules assigned by
Ministry of Environment, Forest and Climate
Change or Central Pollution Control Board from
time to time.
(ix) Implementation of recommendations of the Advisory
Committee.
(x) Publish the list of Registered or Authorised (or give
consent) Recyclers.
(xi) Undertake and support third party audits of the
common bio-medical waste treatment facilities in
their State.
7 Municipalities or Corporations,
Urban Local Bodies and Gram
Panchayats
(i) Provide or allocate suitable land for development of
common bio-medical waste treatment facilities in
their respective jurisdictions as per the guidelines of
26
Central Pollution Control Board.
(ii) Collect other solid waste (other than the bio
medical waste) from the health care facilities as
per the Municipal Solid Waste ( Management and
handling) Rules, 2000 or as amended time to time.
(iii) Any other function stipulated under these Rules.
27
SCHEDULE IV
[See rule 8(3) and (5)]
Part A
LABEL FOR BIO-MEDICAL WASTE CONTAINERS or BAGS
CYTOTOXIC HAZARDSYMBOL
HANDLE WITH CARE HANDLE WITH CARE
Part B
LABEL FOR TRANSPORTING BIO-MEDICAL WASTE BAGS OR CONTAINERS
Waste category Number .......
Waste quantity..............
Sender's Name and Address
Phone Number .......
Fax Number..............
Contact Person .......
In case of emergency please contact :
Name and Address :
Day ...........Month .............
Year ..........
Date of generation ..................
Receiver's Name and Address:
Phone Number ..............
Fax Number ................
Contact Person ........
Phone No.
Note :Label shall be non-washable and prominently visible.
Previous and next
Questions people ask
Is rule 18 of Bio-Medical Waste Management Rules, 2016. still in force?
No repeal of Bio-Medical Waste Management Rules, 2016. is recorded.