APPENDIX A-12

APPENDIX A-12 [See rule 115] SPECIAL PLANNING NORMS FOR LOW INCOME HOUSING (ECONOMICALLY WEAKER SECTION AND LOWER INCOME GROUP) 222 (281) 1. GENERAL.-( 1) The planning and general building requirements in case of Low Income Housing (EWS and LIG] developed as clusters shall be as provided herein. These norms shall be applicable to all such housing projects undertaken by the Government departments and all Public/ Private agencies. (2) Such development should be as far as possible in clusters of 400 dwelling units, so distributed to maintain the overall densities of the Development Scheme for the area . 2. PLANNING.-(1) Type of Development. The type of development for low income housing may be:- (a) plotted development; (b) flatted /Group Housing. (2) Density.- The maximum .· density in terms of dwelling units/hectare shall be as provided in the following table - TABIE MAXIMUM DENSITIES OF ECONOMICALLY WEAKER SECTION AND S.No. EWS (1) (i) (ii) (iii) . (iv) Note:- LOW INCOME GROUP HOUSING [See clause 2 (2) 1 Density ( dwelling Units/hectare) LIG (2) (3) 130 85 250 170 300 225 350 260 No. of Storey's (4) 1 2 3 4 1. Vertical incremental housing shall be permitted m single ownership plot. 222 (282) 2. 3. 4. 1l~ ~, ~ 14 1lfif 2016 These densities include provision for open spaces, convenient shopping, nursery and all internal roads and pathways, but do not include peripheral road around the cluster. The minimum density shall be 75 per cent of the above. The height of the building having four storeys as above shall not exceed 12.5 mtrs. (3) (i) Size of Plot / built up Area : The plot area or the built up area for Economically Weaker Section and Lower Income Group houses shall be such, as may be decided by the agency. The ground coverage may extend to a maximum of75 per cent. (ii) Minimum Frontage.-The minimum frontage of the plot shall be 3.6 mtrs. (4) Height of building: The height of a building shall be as mentioned in clause of the Appendix 2 (note-4) above, which shall not exceed 12.5 mtrs. In case the height has to be increased beyond 12.5 mtrs. lifts shall be provided. The density in terms of dwelling units per hectare shall be accordingly determined. 3. General building requirements.-The following norms shall also be adhered (1) Plinth.- The minimum height of plinth shall be 30 centimetres from the surrounding ground level. (2) Size of room. (a) Habitable Room- • (i) In the case of one-roomed house, the size of the multipurpose room including space for cooking shall be not less than 10 square meters with a minimum width of 2.4 meters. (ii) In the case of two roomed house, the size of a room shall not be less than 6.5 square meters with a minimum width of 2.1 meters: Provided that total area of both rooms is not less than 15 square-meters. In case of incremental housing to be developed as a future two roomed house, the total area of rooms to be provided in the initial and later stages shall not be less than 16 square meters. (b) Water Closet/Bath Room. (i) Size of independent water closet shall be 0.9 x 1.0 meters. 222 (283) (ii) Size of independent bath shall be 1.0 x 1.2 meters. (iii) Size of combined bath and water closet shall be 1.0 x 1.8 meters and this may be permitted in one roomed house. (c) Kitchen: The size of cooking alcove serving as cooking space shall not be less than 2.4 square meters with minimum width of 1.2 meters. The size of individual kitchen provided in two- roomed house shall not be less than 3 .3 square meters with a minimum width of 1.5 meters. ( d) Balcony - The minimum width of individual balcony, where provided, shall be 0.9 meter (3) (a) Minimum Height -The minimum height of rooms/spaces shall be as follows:- (i) Habitable Room - 2.6 meters. (ii) Kitchen - 2.4 meters. (iii) Bath/Water Closet - 2.2 meters. (iv) Corridor-2.1 meters. (b) In the case of slopping roofs, the average height of roof for habitable rooms shall be 2.6 meters and the minimum height at eaves shall be 2.0 meters. ( 4) Lighting and Ventilation. The openings through windows, ventilators and other for lighting and ventilation shall be as • provided in sub-rule (3) of rule 98. Note: The window and other opening shall abut on to open spaces either through areas left open within the plot or the front, side and rear spaces provided in the layouts which shall be treated as deemed to be sufficient for light and ventilation purposes. (5) Stairs: The following criteria shall be adopted for internal individual staircase:- (a) Minimum Width (i) 2 storeyed - straight (ii) 2 storeyed - winding (iii) 3 or more storeyed - straight (iv) 3 or more storeyed - winding (b) Riser (c) Tread (i) 2 storeyed (ii) 3 storeyed or more 0.60 meter 0.75 meter 0.75 meter 0.90 meter 20.0cmmax. 22.5 cm min. 25.0 cm min. 222 (284) Note: This could be reduced to 20 centimetre as the clear tread between perpends with possibility of open rise as well as nosing and inclined riser to have an effective going of 22.5 centimetre. ( d) Head Room. The minimum clear head room shall be 2.1 meters. ( 6) Circulation Area - Circulation area on any floor including staircase shall not exceed 2.0 square meters/unit where 4 dwelling units are grouped around a staircase and 4.0 square meters/unit where 2 dwelling units are grouped. 4. Roads and pathways.- (1) The area under roads and path-ways in such housing projects shall not ordinarily exceed 25 per cent, of the total land area of the project. Access to the dwelling units, particularly where motorised vehicles are not normally expected shall be by means of paved footpaths with right of way of 6 meters and paved-way of minimum 2 meters only. The right of way shall be adequate to allow for the plying of emergency vehicles and also for road side drains and plantation. Where motor able access-ways are not provided and pedestrian path-ways are provided, the minimum width of such pedestrian pathway shall be 3 meters with maximum length of 100 meters. (2) The community open spaces shall not be less than 0.2 Hectares per thousand persons, one nursery school of 0.1 hectare shall be provided for a population of 1500 and shopping centers at 4 shops per thousand population will be provided. 5. Other requirements.- (1) One water tap per dwelling unit may be · provided where adequate drinking water supply is available. If supply is inadequate, public hydrants shall be provided. In the absence of piped water supply, it could be done through hand pumps. (2) The infrastructural services shall be provided before the plots are handed over to the individual owners. 6. Site and services schemes.-(1 ). Services would have to be laid by the agency concerned as per the provisions of these rules. (2) The agency may instead of building the houses provide for site and services schemes. Such scheme shall provide for the following:- (a) infrastructure needed for a permanent housing in accordance with the provisions hereinabove; (b) a service sanitary core in the plot; and ( c) temporary construction on a developed plinth. l{~ ~, ~ 14 lfM' 2016

Previous and next

All provisions of MP Investment Region Development and Management Rules 2016

Questions people ask

Is appendix A-12 of MP Investment Region Development and Management Rules 2016 still in force?

No repeal of MP Investment Region Development and Management Rules 2016 is recorded.