Rule 64, .lharkhand Building Bye-laws 2016: Cinema, Multiplex and Theatre building
.lharkhand Building Bye-laws 2016 - Rule 64
Text of rule 64
Cinema, Multiplex and Theatre building
64. Cinema, Multiplex and Theatre building.-
64.1 The relevant provisions of the Jharkhand Cinemas (Regulation) Act,
1954 or any other relevant act sha 11 apply for planning, designing and
construction of Cinema and Theatre buildings.
64.2 No permission for construction of a building to be used as a cinema
hail, theatre or auditoria for cultural show shall be granted unless the
construction of such buildings conforms to the provisions of the
Jharkhand Cinemas (Regulation) Act, 1954 or any other law in the
subje~t for the time being in force in the State.
<>">
CHAPTER -VII
REQUIREMENT FOR SPECIAL OCCUPANCIES
Jharkhand Building Bye-Laws-2016
- 97 -
Only for filling stations -30m x 20rn
~~,f
A.
66.3
,.
A. For minor roads having less than 30 m. width - 50 m.
B. For major roads having width 30 m. or more -100 m.
The minimum distance of the property line of petrol pump from the
centre I ine of the road shal I not be less than 15 meters on roads having
less than 30 m width. In case of roads having 30 m or more width, the
width of the road shall be protected.
Plot size:-
66.2
66.1 Minimum distance from the road intersections shall be:
66. Petrol Pump
65.2 ot withstanding anything contained in the conditions specified above,
cylinders containing liquefied petroleum gas exceeding 100 Kilograms
but not exceeding 300 Kilograms may be kept in a storage shed
forming part of, or attached to building, if it is separated there from by
a substantial partition and the only means of access to it is from
outside. Such a storage shed shall not be situated under any staircase or
near other entrances to or exits from the rest of the building or other
buildings. A shed used for storage of liquefied petroleum gas cylinders
shall be surrounded by a suitable fence to prevent unauthorized persons
from having access to the shed.
Quantity of Compressed Gas in Minimum Clear Distance to be Kept
Cvlinders (Ke..) (meters)
0-100 I
101-1000 3
1001-4000 5
4001-8000 7
8001-12000 9
12001-30,000 12
Over 30,000 15
Table - 21: Minimum distances required for storage shed of' liquefied petroleum gas cylinders
Previous and next
Questions people ask
Is rule 64 of .lharkhand Building Bye-laws 2016 still in force?
No repeal of .lharkhand Building Bye-laws 2016 is recorded.