LawGrids logoLAWGRIDS.ORG

Form A4, Karnataka Lifts, Escalators and Passenger Conveyors Rules, 2015: FORM-A4

Karnataka Lifts, Escalators and Passenger Conveyors Rules, 2015 - Form A4

Text of form A4

FORM-A4

FORM-A4 . I/We hereby declare that I/We undertake the work of erection of lift or escalator or passenger conveyor for which permission to install may be granted under the Karnataka Lifts, Escalators and passenger conveyors Act, 2012(Karnataka Act No.09 of 2013). I/We also undertake the responsibility to extend full co-operation during the inspection of works of lift or escalator or passenger conveyor installation by the Inspector of Lifts, Escalators and Passenger conveyors and rectify the defects pointed out by him. The lift or escalator or passenger conveyor installed by me/us shall be handed over to the respective owner after the license to use the lift or escalator or passenger conveyor is issued under section 4 of the Act. Date: Signature of the Authorized Signatory with seal of the Li f t /escalator/Passenger Conveyor erect ion and/ maintenance regis tered person [See sub-rule (2) of rule 3] GOVERNMENT OF KARNATAKA (Department of Electrical Inspectorate) Letter No………………… To ……………………….. ……………………….. ………………………... Sir, SUB: Permission for erection of ………….no. of …………make Lift or Escalator or passenger conveyor having…………….. No. of landings / stops of ………………………………………………………..at …………………….. Ref: ……………………………….. ---------------- Under sub-section (3) of Section 3 of the Karnataka Lifts, Escalator and Passenger conveyors Act, 2012 (Karnataka Act No. 9 of 2013), permission is hereby granted to erect …………..no. of……….make Lift or Escalator or Passenger conveyor having…………. no of landings at the premises……………………………………………………………….........................................owned by ………………………………………………………………………………...subject to the provisions of the Karnataka Lifts, Escalator and Passenger conveyors Act, 2012 (Karnataka Act No. 9 of 2013) and the Karnataka Lifts, Escalator and Passenger conveyors Rules, 2015. This permission is valid for a period of one year from the date on which it is granted. The Lift or Escalator or Passenger conveyor shall not be used until a license is granted by the Chief Inspector of Lifts, Escalators and Passenger conveyors for use of the Lift or Escalator or Passenger conveyor in accordance with section 4 of the Karnataka Lifts, Escalator and Passenger conveyors Act, 2012. After completion of the Lift or Escalator or Passenger conveyor erection work following documents shall be furnished to ……………………………. to arrange for inspection. 1. Work completion report in Form-B2 and/or B3 from the registered person to whom the lift or escalator or passenger conveyor erection work is entrusted for having carried out the installation as per the Karnataka Lifts, Escalators and Passenger conveyors Act, 2012 , Karnataka Lifts, Escalators and Passenger conveyors Rules, 2015 and Bureau of Indian Standards. 2. Form-B1 from the Owner of the Lift or Escalator or passenger conveyor 3. An original treasury challan or receipt of Rs…….. for having remitted inspection fee for lift/escalator/passenger conveyor as per sub rule (2) (ii)of rule 4. 4. A copy of electrical safety certificate/approval if the building height exceeds 15 mtrs. Signature Authorized officer / Inspector of Lifts, Escalators and Passenger conveyors 14 FORM – B1 [See sub-rule(1) of rule 4 ] To Application for a license to use the Lift/Escalator/Passenger conveyor. The Inspector of Lifts, Escalators and Passenger conveyors ………………………. Sir, Subject : Work Completion of Erection of Lift/Escalator/Passenger conveyor at the……………………………………………………………………………………… …………………… Ref: (1) Erection permission no………………………….. I, With reference to your letter No……..….dated……… by which permission has been granted to erect a Lift/Escalator/Passenger conveyor at the above mentioned premises. I/We, have to state that the work of erection of the Lift/Escalator/Passenger conveyor completed on........................... The completion report/s of the registered person in Form-B2 for Lift/s and/ form-B3 for escalator and passenger conveyor are enclosed here with. I/We, further request that a license for using the Lift/Escalator/Passenger conveyor may be granted. The work of erection of Lift/Escalator/Passenger conveyor has been carried out in accordance with the Karnataka Lift, Escalator and Passenger conveyor Act, 2012 and Rules 2015 made there under. Challan/receipt for having paid the prescribed inspection fees of Rs.........................vide Challan/Receipt No ....................dt .....................at .................................... is enclosed. Date : Yours faithfully, Signature of the Owner of the premises Note: The form should also accompany the work completion report of erector in Form-B2 for Lift/s and form-B3 for escalator and passenger conveyor] FORM – B2 [See clause (i) sub-rule (2) of rule 4] The Inspector of Lifts, Escalators and Passenger conveyors Lift erection completion report of registered person authorized under section 6 To, …………………………………………………………….. Sir, Subject: Work completion of Erection of Lift at the …………………………………. Ref: 1) Erection permission letter no………………………………………………………. 2) Our Contract No:……………..dated…………with M/s………………………Lift at…………………… ******** The work of installation of Lift/s at M/s.................... have been carried out by me/us having Registration No ......................... and Electrical contractor license No ....................as per the provisions of the Karnataka Lifts, Escalators and Passenger conveyor Rules 2015 and Indian Electricity Rules, 1956 / Central Electricity Authority (Measures relating to safety and electric supply) Regulations, 2010, Bureau of Indian Standards and/ International Electro Technical Commission standards. The motors, controllers, governors and ropes have been tested and confirm to IS and/ International Electro Technical Commission specifications. We further certify that the Lift/s installation is ready for inspection which is required to be made for the purpose of issuing license under the Karnataka Lifts, Escalators and Passenger conveyors Act, 2012 for operating the same. The following are the details/specifications of Lift/s. Part-1 Sl.No Description Lift-1 Lift-2 …….lift n 1 No. of floors of the building 2 Type and Make of lift erected (i.e., Passenger, Hospital, Goods cum Passenger etc) 3 No. of stops / lift landings 4 Type of doors; (a) Car (b) Landing 5 The rated maximum speed of the lift car in metre/second 15 6 The makers or designers rated capacity in weight (kg) 7 Details of emergency stop switch, floor leveling switch, floor selectors and car door switch 8 Lift car dimension in mm 9 Dimensions of Lift well in mm, and details of lift well enclosures. 10 The maximum No of passengers in addition to the lift operator which the lift can carry. 11 The total weight of the lift Car/Cage carrying the maximum load in kilo grams. 12 The weight of the counter weight (kilo grams) 13 The number of supporting Ropes/cables and Size in sq. mm 14 Type of roping ( i.e 1:1, 2 : 1 etc) 15 Bottom clearance (a) Car (b) Counter weight 16 Top clearance (a) Car (b) Counter weight 17 Details of the constructed overhead arrangement with the weight and sizes of the beams. 18 Total travel height in mm from lowest landing floor level to top most landing floor level 19 Number and Type of car buffers with name plate details 20 Number and type of counter weight buffers 21 Method of Control 22 Drive /Type of lift operation with its devices 23 Details of over speed governor 24 Whether emergency light and phone provided or not 25 Whether Alarm bell provided or not 26 Lift hoist motor make 27 Capacity of motor in KW/HP 28 Speed of motor in rpm 29 Serial number of hoist motor 30 Type and Make of controller with Sl. No. 31 Over load device provided or not 32 Automatic Rescue Device (ARD) provided or not. 33 Any other information 16 Part-2 DETAILS OF ELECTRICAL INSTALLATION WORK 1 Name plate details of each and individual equipments (make, Specification, Serial number) separate sheet shall be enclosed for Multiple installation 2 Details of wiring / cabling size, numbers of run, length ( UG cable, HT / LT main cable, distribution, sub distribution and load side cables ) 3 Details of Earthing schedule (size of earth leads) 4 Details of Insulation test results (Equipment / Circuit wise), date of Test (a) Between phases (b) Between each phase and earth 5 Details of Earth test results (Equipment / Earth electrode wise), date of test and measured earthing resistance of installation 6 Remarks I certify that the above installation work is carried out under my direct supervision by the qualified wiremen under the Karnataka (Licensing of Electrical contractors and grant of certificates and permits to electrical supervisors and wiremen) Rules 2012 and the installation has been tested with the above test results are furnished for your kind perusal and inspection. Name of Electrical Supervisor = Permit No = S Valid upto = License Number and Class = Valid Upto = Date : Signature along with seal of the Authorised Signatory of the Registered person. Enclosures:- Copy of License, copy of Supervisor permit with Endorsement. FORM – B3 [See clause (i) sub rule (2) of Rule 4] Escalator/Passenger conveyor erection completion report of registered person authorized The Inspector of Lifts, Escalators and Passenger conveyors under section 6 To, ………………………………………………………………. Sir, Subject: Completion of erection of Escalator/Passenger conveyor at the …………………………………………………… Ref: 1) Erection permission letter no………………………. 2) Our Contract No:……………………………..dated…………………… with M/s……………………………….Escalator/Passenger conveyor at……………………………………….. ******** 17 The work of installation of Escalator/s / Passenger conveyor/s at M/s.................... have been carried out by me/us having Registration No ......................... and Electrical contractor license No ....................as per the provisions of the Lift, Escalator and Passenger conveyor Rules 2015 and the Indian Electricity Rules, 1956/Central Electricity Authority (Measures relating to safety and electric supply)Regulations 2010, Bureau of Indian Standards and/ International Electro Technical Commission standards. The motors, controllers, governors and ropes have been tested and confirm to Bureau of Indian Standards and/ International Electro Technical Commission specifications. We further certify that the Escalator/Passenger conveyor installation is ready for inspection which is required to be made for the purpose of issuing license under the Karnataka Lifts, Escalators and Passenger conveyors Act, 2012 for operating the same. The following are the details/specifications of Escalator/Passenger conveyors. Part-1 Sl.No Description Escalator/Passen ger conveyor -1 Escalator/Pass enger conveyor-2 …….Escalator/pas senger conveyor 1 Type of escalator/ Passenger Conveyors (moving walks or travalletor) 2 No. of floors of the building 3 Floor Location of the escalator or passenger conveyor 4 The rated speed of the escalator or Passenger conveyor 5 The makers or designers rated load in weight (kg) 6 The maximum No of passengers per hour which the escalator or Passenger conveyor can carry. 7 Angle of inclination of the escalator or Passenger Conveyors (moving walks or travalletor) 8 The type of balustrading 9 The width between balustrades 10 The Vertical Rise of the escalator in mm 11 The number, description, weight and size of main drive chain, hand rail drive chain and governor drive chain. 12 Details of construction of the stresses and step treads together with weight and size of all structural members and supporting beams in connection therewith. 13 Escalator or passenger conveyor nominal width /discharge area (Z1) 14 Dimensions of Steps 15 Make, capacity in kW/HP of the motor 16 speed in rpm of the motor 17 Serial number of the motor 18 Part-2 DETAILS OF ELECTRICAL INSTALLATION WORK 1 Name plate details of each and individual equipments (make, Specification, Serial number) separate sheet shall be enclosed for Multiple installation 2 Details of wiring / cabling size, numbers of run, length ( UG cable, HT / LT main cable, distribution, sub distribution and load side cables ) 3 Details of Earthing schedule (size of earth lead) 4 Details of Insulation test results (Equipment / Circuit wise), date of Test (a) Between phases (b) Between each phase and earth 5 Details of Earth test results (Equipment / Earth electrode wise), date of test and measured earthing resistance of installation 6 Remarks I certify that the above installation work is carried out under my direct supervision by the qualified wiremen under the Karnataka (Licensing of Electrical contractors and grant of certificates and permits to electrical supervisors and wiremen) Rules 2012 and the installation has been tested with the above test results are furnished for your kind perusal and inspection. Name of Electrical Supervisor = Permit No = S Valid upto = License Number and Class = Valid Upto = Date : Signature along with seal of the Authorised Signatory of the Registered person. Enclosures:- Copy of License, copy of Supervisor permit with Endorsement. FORM – B4 [See sub-rule (3) of Rule 4] To, The Chief Inspector Lifts, Escalators and Passenger conveyors Bangalore. Sir, Sub: Recommendation for issue of license to run the lifts or escalator or passenger conveyor installed at…………… Ref: ******* With reference to the above the installation of ____ no. of Lifts or Escalator or Passenger conveyor was inspected on…………….and found that it is in conformity with Karnataka Lift, Escalator and Passenger conveyor Act, 2012 (Karnataka Act No. 9 of 2013), and rules made there under and also with the Indian Electricity Rules, 1956 /Central Electricity Authority (Measures relating to safety and Electric supply) Regulations 2010. Hence, I hereby recommend the said installation for issue of license to run the same with the following details, namely:- 19 1. Full name and address of the applicant with email ID and Contact No 2. Address of Lift/Escalator/Passenger conveyor installation 3. Reference of erection permission of Lift/Escalator/Passenger conveyor 4. Inspection fee paid details 5. Date of Inspection 6. Type (passenger/service/goods/hydraulic/hospital lift) and number of Lifts/Escalators/Passenger conveyors 7. Make of Lift/Escalator/Passenger conveyor and Registration details of registered person. 8. Bangalore Electricity Supply Company (BESCOM) Sub-division/ DEI Area where the lift/escalator/passenger conveyor is installed. 9. Number of floors of the building 10. Number of Landings 11. Whether approval for the multistoried building has been obtained? If so copy of the approval has been enclosed or not? R.R No. to be mentioned. 12. Test results (1) Earth test (2) Megger test 13. Whether ELCB provided? 14. (a) The maximum Number of passengers and their weight in kg in addition to the lift operator which the lift can carry/ maximum Number of passengers per hour which the escalator or passenger conveyor can carry. (b) The rated speed of the Lift car /Escalator/Passenger conveyor (c) Angle of inclination of Escalator/passenger conveyor (d) Details of the hoisting motor / driving motor 15. Type of doors (a) lift car (b) landing door 16. Whether alarm circuit in Lift car is effectively functioning or not? 17. Whether bottom and upper limit switches have been provided in the Lift shaft or not? 18. Whether switch with plug has been provided on the top of the lift car 19. Nature (Government, Private, Commercial, residential, commercial cum residential, industrial, etc.) of the building in which the lift/escalator/passenger conveyor is installed. 20 20. Whether the building is Multistoried building? if yes, whether it is Yes/no 1. HT MSB less than 24 mtrs 2. HT MSB more than 24 mtrs 3. LT MSB less than 24 mtrs 4. LT MSB more than 24 mtrs 21. Whether the Governor is working properly or not 22. Whether over load device is provided for the Lift or not 23. Whether ARD provided for the Lift or not 24. Whether Machine Room Or Machine room less/gearless lift/s 25. General notes on Inspections and Tests 1. From the lift pit 2. From inside of the lift car 3. From top of the lift car 4. From the machine room 5. From each and every landing of the lift 6. Others. etc…… 26. Remarks (detailed remarks if any use separate sheet). Date :…… Signature of the Inspector of lifts, escalator and passenger conveyors FORM – B5 [See sub rule (4) of Rule 4] Government of Karnataka Details of Equipments License to use Lifts Mr/Messrs. …………………………. is/are hereby authorized to use the ……….Lift/s (particulars of which are given below) installed in the premises …………….. owned by…………… and situated at ………. ……………….. This license shall remain valid from……….to………..and is issued subject to the conditions mentioned in Karnataka Lift, Escalators and Passenger conveyor Rules, 2015 and here under. Inspection fee of Rs………… has been paid vide challan/receipt no…………., dated……… drawn at………………is hereby acknowledged. Sl.No Particulars Details 1 Make of the Lift 2 Type of Lift 3 Capacity 4 Building/ Multistoried building details 5 Nature of the building 6 Type of landing door 7 Type of car door 8 No. of landings 9 Rated load of lift 10 Rated speed 11. Motor details 12. Others Chief Inspector of Lifts, Escalators and Passenger conveyors Karnataka state Bangalore Date : ………………. 21 Renewal of License [see sub rule (3) of rule 5] To, Owner of the Lift ……………………. …………………… Copy to, (1) Additional Chief Electrical Inspector………….. (2) Deputy Chief Electrical Inspector……………… (3) Electrical Inspector……….. (4) Deputy Electrical Inspector…………………….. (5) …………….Operations and Maintenance (O&M) sub-division of ESCOM. (6) Registered person (7) Master file. Conditions: (1) The Lift/s shall be operated and maintained in conformity with the provisions of the Karnataka Lift, Escalators and Passenger conveyor Act, 2012 and the rules made there under. (2) If the holder of this license does not normally reside in the town or village in which the Lift/s has been erected, he shall within one month from the date of this license appoint an agent who shall be resident in the same town, or village. The agent so appointed shall be responsible for the operation and maintenance of the Lift/s in conformity with the provisions of the Karnataka Lift, Escalator and Passenger conveyor Act, 2012 and the rules made there under. The name of every such agent shall be communicated to the Chief Inspector of Lifts, Escalators and Passenger conveyors and also to Inspector of Lifts, Escalators and Passenger conveyors. Any change of agent shall be similarly intimated. (3) Owner of the Lift/s installation shall enter into a maintenance agreement with the Lift/s erection and / maintenance person registered with the Chief Inspector of Lifts, Escalators and Passenger conveyors. (4) A copy of the Lift/s license shall be displayed in the lift machine room. (5) If any fatal/non-fatal accident occurs in the operation of Lift/s, the owner or the agent appointed by the owner shall give notice with full details in the prescribed format to the Inspector of lifts, Escalators and Passenger conveyors and to the Commissioner of Police and District Magistrate. (6) No additions or alterations to the Lift/s and its installation shall be carried out without prior approval of the Chief Inspector of Lifts, Escalators and Passenger conveyors. (7) Trained lift/s operator shall be appointed for operation of the Lift/s. Sl. No License renewed Renewal fee Paid details Initials of Chief Inspector of Lifts, Escalators and Passenger conveyors From valid up to Amount Challan/R eceipt Date 1 2 3 4 5 6 7 22 FORM – B6 [See sub rule (4) of Rule 4] Government of Karnataka Details of Equipments License to use Escalators/Passenger conveyors Mr/Messrs. …………………………. is/are hereby authorized to use the Escalator/Passenger conveyor (particulars of which are given below) installed in the premises …………….. owned by…………… and situated at ………. ……………….. This license shall remain valid from……….to………..and is issued subject to the conditions mentioned in Karnataka Lift, Escalators and Passenger conveyor Rules, 2015 and here under. Inspection fee of Rs………… has been paid vide challan/receipt no…………., dated……… drawn at………………is hereby acknowledged . Sl.No Particulars Details 1 Make of the Escalator/Passenger conveyor 2 Capacity 3 Building/ Multistoried building details 4 Nature of the building 5 Angle of inclination of escalator/passenger conveyor with the horizontal 6 Width of the escalator/passenger conveyor 7 Vertical rise of the escalator 8 Rated load of escalator/passenger conveyor 9 Rated speed 10 Motor details 11 Others Chief Inspector of Lifts, Escalators and Passenger conveyors Karnataka state Bangalore Date : ………………. Renewal of License [see sub rule (3) of rule 5] To, Owner of the Escalator/Passenger conveyor ………………………………………………………. ………………………………………………………. Copy to, (1) Additional Chief Electrical Inspector………….. (2) Deputy Chief Electrical Inspector……………… (3) Electrical Inspector……….. (4) Deputy Electrical Inspector…………………….. (5) …………….Operations and Maintenance (O&M) sub-division of ESCOM. (6) Registered person (7) Master file. Sl. No License renewed Renewal fee Paid details Initials of Chief Inspector of Lifts, Escalators and Passenger conveyors From valid up to Amount Challan/ Receipt Date 1 2 3 4 5 6 7 23 Conditions: (1) The Escalator/Passenger conveyor shall be operated and maintained in conformity with the provisions of the Karnataka Lift, Escalators and Passenger conveyor Act, 2012 and the rules made there under. (2) If the holder of this license does not normally reside in the town or village in which the Escalator/Passenger conveyor has been erected, he shall within one month from the date of this license appoint an agent who shall be resident in the same town, or village. The agent so appointed shall be responsible for the operation and maintenance of the Escalator/Passenger conveyor in conformity with the provisions of the Karnataka Lift, Escalator and Passenger conveyor Act, 2012 and the rules made there under. The name of every such agent shall be communicated to the Chief Inspector of Lifts, Escalators and Passenger conveyors and also to Inspector of Lifts, Escalators and Passenger conveyors. Any change of agent shall be similarly intimated. (3) Owner of the Escalator/Passenger conveyor installation shall enter into a `maintenance agreement with the lift/Escalator/Passenger conveyor erection and / maintenance person registered with the Chief Inspector of Lifts, Escalators and Passenger conveyors. (4) A copy of the Escalator/Passenger conveyor license shall be displayed in the lift machine room. (5) If any fatal/non-fatal accident occurs in the operation of Escalator/Passenger conveyors, the owner or the agent appointed by the owner shall give notice with full details in the prescribed format to the Inspector of lifts, Escalators and Passenger conveyors and to the Commissioner of Police and District Magistrate (6) No additions or alterations to the Escalators/ Passenger conveyor and its installation shall be carried out without prior approval of the Chief Inspector of Lifts, Escalators and Passenger conveyors. (7) Trained operator shall be appointed for operation of the Escalator/Passenger conveyor. FORM – C1 [See sub-rule (1) of rule 5] Application for renewal of license to use Lift/Escalator/Passenger conveyor To, The Inspector of Lifts, Escalators and Passenger conveyors Sir, Sub: Renewal of License to use Lift/Escalator/Passenger conveyor With reference to above, it is stated that the license to use Lift/Escalator/Passenger conveyor installed at ……………………………… is sent herewith for renewal thereof as required under section 5 of the Karnataka Lifts, Escalators and Passenger conveyors Act, 2012 and it is requested to return the same after renewal. An original copy of Treasury challan of Rs……… being the renewal fee and a test report in form- C2 for Lifts and/ form-C3 for Escalators and/passenger conveyor are also enclosed. Date:…… Enclosing: As above Yours faithfully, Signature of the owner FORM – C2 [See sub-rule (1) of rule 5] Test Report of Lift Installation To, The Inspector of Lifts, Escalators and Passenger conveyors, Sir, Sub: Test report of lift installation, rope etc -reg. As required by sub-rule (1) rule 5 of the Karnataka Lifts, Escalators and passenger conveyors Rules, 2015, I/we here by certify that the Lift /s installed at………………….. and owned by ……………………………………… is/are under my/our maintenance. We have conducted the following checks/examination/tests and the results are here under. Sl. No Particulars Details of tests performed and results 1 Distinguishing number or mark (if any) and description sufficient to identify the lifting machine, chains, rope or the lifting tackel Type of lift: Serial No: Make: 24 2 Date and number of the certificate relating to any test and examination made ; (a) Electric traction lifts (1) Oil buffer tests (a) Annual Tests (2) Governor and safety (3) Test of slack rope device or winding drum machine (4) Test of normal terminal stopping device (5) Test of final terminal stopping device (6) Standby power operation (7) Power door operation closing force and speed (8) Broken rope, tape or chain switch (9) Electrical protective devices test (10) Ascending car and unintended motion device test (b) Five year tests.- (1) Governor test (over speed switch setting and Governor trip setting) (2) Types “A”, “B” and “C” safeties (3) power test (4) Test of oil buffer (5) Brake for passenger elevators and freight elevators authorized to carry passengers (6) Test of emergency terminal stopping device (speed limiting device) (7) Test of leveling speed and leveling zone (8) Inner landing zone test (static controls) (b) Hydraulic Elevator tests (a) (1) Working pressure and Relief valve Annual Tests (2) Pressure test of Flexible hose and fitting (3) Hydraulic cylinder leak test (4) Terminal speed reducing (5) Standby power operation (6) Power operation of doors (7) Normal terminal stopping device (8) Low oil and RPR protection (9) Supply line and valve (10) Slack rope device (11) Emergency operation FFS (12) Pressure switch (13) Oil buffers (14) Car safety (15) Governor (1) Car oil buffer (b) Five year tests (2) Plunger gripper (3) Over speed valve (seismic valve) 25 3 Date of periodical examination made 4 Particulars of any defects affecting the safe working load found at such through examination or after annealing and of the steps taken to remedy such defect. We certify that on…………… , we have thoroughly examined the lift/s and that above is a correct report of the result. Further the installation of the aforesaid Lift/s satisfies the entire requirement as laid down under the Karnataka Lifts, Escalators and passenger conveyors Act, 2012, and rules made there under. I/we maintain log book as required under rule 9(5) of Karnataka Lifts, Escalators and passenger conveyors Rules, 2015. Date: Signature of the registered person Registration No and validity FORM – C3 [See sub-rule (1) of rule 5] Test Report of Escalator/Passenger conveyor Installation To, The Inspector of Lifts, Escalators and Passenger conveyors, Sir, Sub: Test report of Escalator/s and/ passenger conveyor/s installation-reg. As required by rule 5(1) of the Karnataka Lifts, Escalators and passenger conveyors Rules, 2015, I/we here by certify that the Escalator(s)/Passenger conveyor(s) installed at………………….. and owned by ……………………………………… is/are under my/our maintenance. We have conducted the following checks/examination/tests and the results are here under. Sl. No Particulars Details of tests performed and results 1 Distinguishing number or mark (if any) and description sufficient to identify the lifting machine, chains, rope or the lifting tackel Type of Escalator and passenger conveyor: Serial No: Make: 2 Date and number of the certificate relating to any test and examination made ; a) Escalators (1) Escalator skirt obstruction devices Annual Tests.- (2) Operating devices (3) Egress restriction (rolling shutter device) (4) Speed test (5) Machine space, access, lighting, receptacle and condition (6) Machine space stop switch (7) Controller wiring and fuses (8) Brake torque test (9) Speed governor 26 (10) Broken drive chain device (11) Driving machine brake test (12) Reversal stop device (13) Broken step chain device or treadway device (14) Escalator Step upthrust device (15) Missing step device or pallet device (16) Step level device (17) Pallet level device (18) Steps, pallets, step or pallet chain trusses (19) Handrail safety system entry device and speed monitoring (20) Heaters outdoor units (21) Stretch of step chain (22) Disconnected motor device (23) Response to smoke detectors (24) Comb-step/comb-pallet impact devices (25) Step/skirt performance index (26) Clearance between step and skirt (loaded gap) (27) Inspection controls (28) Step lateral displacement device. (29) Combplate load test (b) Moving Walk/passenger conveyor tests (1) Machine space Annual Tests.- access (2) Machine space stop switch (3) Controller wiring and fuses (4) Brake torque test (5) Speed governor (6) Broken drive chain device (7) Reversal stop device (8) Broken step chain device (9) Missing pallet device (10) Pallet level device (11) Pallet, chain and trusses (12) Handrail safety system entry device and speed monitoring (13) Heaters outdoor units 27 (14) Disconnected motor device (15) Response to smoke detectors (16) Comb/pallet impact device (17) Inspection controls 3 Date of periodical examination made 4 Particulars of any defects affecting the safe working load found at such through examination or after annealing and of the steps taken to remedy such defect. We certify that on…………… , we have thoroughly examined the Escalators and/or Passenger conveyors and that above is a correct report of the result. Further the installation of the aforesaid Escalators and/or Passenger conveyors satisfies the entire requirement as laid down under the Karnataka Lifts, Escalators and passenger conveyors Act, 2012, and rules made there under. I/we maintain log book as required under rule 9(5) of Karnataka Lifts, Escalators and passenger conveyors Rules, 2015. Date: Signature of the registered person Registration No and validity FORM – D1 [See sub-rule (1) of rule 6] Application for registration of manufacturer or maker or other Person who intends to either erect or install and / or carryout maintenance of Lifts or Escalators or Passenger conveyors. To, The Chief Inspector of Lifts, Escalators and Passenger conveyors. Bangalore. 1. Name of the applicant 2. Legal status (whether individual firm or company) (Registration number and names of partners or directors to be given in case of firm or company, as the case may be) 3. Proof for independent office (commercial) located within the state (Details about possession to be enclosed) 4. Whether Certificate of Registration was obtained in the past. If so, give number and date of certificate of Registration : 5. Firm/company Profile along with particulars relating to erection or maintenance of lifts/escalators/passenger conveyors. (Details of lifts/escalators/passenger conveyors erected or maintained to be furnished) 6. Manufacturing activities of the firm/company (Details to be given). If not, outsourcing vendors list to be furnished for each and every lift/escalator/passenger conveyor auxiliary component or equipments and their recommendations for supply of ISI standard materials. 28 7. Whether employed have the following Qualification,- (a) B.E /Diploma holder in Electrical engineering. (b) B.E/Diploma holder in Mechanical Engineering (c) ITI technicians one each in Electrician, Fitter and Electronic mechanic/Instrumentation trade 8. List of entire staff employed along with their Qualification and Designation details with experience certificates and certified copy of testimonials (to be enclosed separately) 9. The Electrical Contractor License issued in the name of firm/company with number and validity (attested copy to be enclosed) 10. Details of (i) Electrical Supervisors (ii) Electrical Wiremen Endorsed to your Electrical contractor license (attested copies to be enclosed) 11. Bank Guarantee certificate is enclosed or not? (1) Name of the Bank: (2) Bank Guarantee certificate No. (3) Date: 12. VAT Registration certificate enclosed or not? ( attested copies to be enclosed) 13. Service Tax Registration, etc., enclosed or not? ( attested copies to be enclosed) 14. Details of erecting, testing instruments As per Annexure-2 15. Details of safety gadgets/tools as per Annexure-3 16. Address of logistic centre /workshop and the list of machineries and equipments /materials maintained. 17. Details of facilities of vehicles available 18. Details of Group Insurance policy (proof to be enclosed) 19. Proof for having land telephone connection with Contact Number 20. Product catalogue of the firm/company 21. Registration fee paid details (an original Treasury Challan or receipt to be enclosed) 22. Remarks I/we hereby declare that the particulars given above are correct to the best of my/our knowledge. I/We will abide by all the Rules and Conditions for issue of Registration failing which our registration may be cancelled. Date :………….. Signature: Place:……….. Name: Designation: Note: (1) Any person who makes, procures to be made or assist in making any false statement for the purpose of obtaining for himself or any other person a certificate of registration for erection and maintenance of lifts/escalators shall render himself liable to prosecution. (2) If additional space is required for completing any items, additional sheet may be attached to this form. 29

Previous and next

All provisions of Karnataka Lifts, Escalators and Passenger Conveyors Rules, 2015

Questions people ask

Is form A4 of Karnataka Lifts, Escalators and Passenger Conveyors Rules, 2015 still in force?

No repeal of Karnataka Lifts, Escalators and Passenger Conveyors Rules, 2015 is recorded.