Rule 50, The Karnataka Cinemas (Regulation) Rules, 2014.: Passages, Corridors, etc
The Karnataka Cinemas (Regulation) Rules, 2014. - Rule 50
Text of rule 50
Passages, Corridors, etc
50. Passages, Corridors, etc.- (1) The Auditorium shall have, 1[a verandah or a covered
corridor wherever there are side entrances ]. No corridor, verandah, passage or staircase
landing lobby, not being an internal passage between rows of seats intended for use as exist
shall be less than 1.83 meters clear in width and there shall be no projection of lights in the
wall of such corridors, verandahs, passages or staircase landing lobby within 2.1 meters height
from the floor.
(2) Wherever possible, gradients or inclined planes shall be used instead of steps, but
no such gradients or inclined planes shall be steeper than 1 in 10.
(3) No corridor, verandah or passage or gangway shall be used as a cloak room and no
pegs for hanging hats or cloaks shall be allowed therein. No such corridor, verandah, passage
or gangway shall be used for storage purpose or for any purpose whatever except for exit and
entrance from and to the auditorium.
(4) Where cloak rooms are provided it shall be so situated that the use of them shall not
obstruct the free use of any corridor, verandah, passage or exit.
(5) Whenever show windows, show-cases and slotting machines are permitted in the
verandahs, corridors and lounges, the Licensing Authority shall satisfy himself, before issuing
the license and regranting the same that there remains the clear space specified under sub-
rule(1) and they are not located near the entrances and exits so as to avoid concentration of
public and obstruction of easy movement.