4. Recognition of Laboratories.- (1) Every laboratory desirous or obtaining
recognition under.these rules for carrying out tests for the approval of the model of any
weight or measure shall make an application to the Director in the form as may be
notified from time to time. .
(2) Every application referred to in sub-rule (1) shall be made by the Principal officer of
the laboratory.
(3) When an application is made under sub-rule (1) for the recognition of a laboratory,
the Director shall, before issuing the certificate of recognition send one or more of his
officers to the laboratory and obtain a report whether the laboratory,
(a) has the necessary measuring equipment; testing facilities and buildings maintained
in a proper conditions;
(b) has the necessary qualified staff, component to undertake the tests for
recommending the approval of model of the concerned weight or measure;
(c) is situated in an appropriate environment;
(d) has an adequate recording system;
(e) is likely to give expeditious efficient and adequate service; and
(f) is ready and willing to get its equipment verified periodically by such other
appropriate laboratory, as may be specified by the Director.
(g) has the certificate issued by the National Accreditation Board of Laboratories (NABL)
in the parameter or field in which model test is proposed to be undertaken.
(4) The Director shall, after considering the information supplied to him by his officer,
or officers referred in sub-rule (3) and if necessary, after a visit to the laboratory, shall
issue to the applicant laboratory a certificate of recognition specifying therein the terms
and conditions subject to which the recognition is granted, and the code number which
has been assigned to the laboratory.
(5) Where no application for the recognition of a laboratory has been made, or where
such application having been made has not been disposed of, the Director may if he is
satisfied that it is urgently necessary so to do, issue, with the consent of the principal
officer in-charge of the laboratory a provlsional certificate of recoqnltlon to a laboratory
which, in the opinion of the Director fulfils all the requirements of sub-rule(3) and the
provisional certificate so issued shall be valid for one year.
(6) The certificate of recognition granted to laboratory may be suspended by the
Director in the event of the omission or failure on the part of the laboratory to observe
the terms and conditions specified under sub-rule (4): .
Provided that no such suspension .shall be made except after giving to the laboratory
.reasonable opportunity of showlnq cause against the proposed action.
.
(7) Where any certificate of recognition to a laboratory is suspended under sub-rule (6),
the order of suspension shall not be vacated unless the omission . or of
compliance of terms and conditions for which such suspension was made ·has been
made good. .
(8) The Director or his authorised officer may visit the laboratory as and when required
and the Principal Officer will permit inspections and render all assistance for the
THE GAZETTE OF INDIA: EXTRAORDINARY [PART II-SEC. 3(i)]18
_ _ _ " 0 ' - -+ _. _
purpose including the production of records with regard to model testing.
(9) The Principal Officer shall submit annually to the Director a report in respect of the
models tested by them, the fee collected, time taken for each testing and such other
relevant particulars.
(10) The Principal Officer, while testing the models adopt such procedures as may be
prescribed by the Director from time to time. '
(l1)The certificate of recognition granted to a laboratory may be cancelled by the
Director if the circumstances of the laboratory are such that it cannot be reasonably
expected to function properly as a recognized laboratory or if there are sufficient
reasons to suspect that the laboratory has been guiltyof corrupt practices.
Provided, that no certificateof recognition shall be cancelled except after to the
concerned laboratory a reasonable opportunity of showing cause against the proposed
action.
CHAPTER III
APPROVAL OF MODELS
Application for the approval of models.- (1) An application for the approval of
model shall be made to the Director and shall contain.
(a) the full name and ,address of the applicant or where the model is imported from
other countries, the name and address of the manufacturer as well as the dealer in
India.
(b) a brief description of the weight or measure the class to which it belongs and the
probable uses for which the weight or measure is intended to be produced;
(c) data regarding metrological and technical characteristics and qualities of the weight
or measures;
(d) test procedure followed by the manufacturer;
(e) trade name or brand name and type of the weight or measure, and
ef) the requisite fees specified in rule 19.
(2) Every application shall be accompanied by not less than two copies of,
(a) a sketch and section-wise drawings of general arrangements and installation of such
weight or measures including therein the details of construction of the weight or
measure in such manner as to enable the visualization of the weight or measures in its
finished form, and;
(b) a document describing the follOWing namely:
(i) the principles of construction and the method of operation of the weight or measure;
(ii) the safety devices provided to prevent any fraudulent or inaccurate operation of the
weight or measure;
(iii) the manner in which and the extend to which the weight or measure may be
adjusted or corrected;
(iv) the place where the verification stamp or seal, or both, may be affixed;
(v) plans of general arrangements and installations drawinqs of the weight or measure
and, where necessary detailed installation instructions;
(Vi) two photographs of the model clearly indicting the mandatory declarations to be
. .
... - ----_.. --- -_ ..
19 3(0]
included as a part of the certificate of approval of the model;
(vii) actual circuit diagram (for digital type);
(viii) place/places on the instrument where the verification stamp or seal or both have
to be applied to prevent fraudulent practices;
(ix) copies of the user's manual, printed pamphlets and other literatures;
(x) any other information which the applicant may consider to be useful for assessing
the performance, and facilitating the approval of the model;
(3) If the weight or measures is provlded with supplementary or additional devices, full
information with regard to such supplementary or additional devices, such as drawing,
descriptions in relation to the said weight or measures, shall also be given along with
) the application.
Previous and next
← Rule 3General provisrons relating to laboratoriesRule 6 →Submission of the models of weight or measure
All provisions of Legal Metrology (Approval of models) Rules 2011
Questions people ask
Is rule 4 of Legal Metrology (Approval of models) Rules 2011 still in force?