LawGrids logoLAWGRIDS.ORG

Rule 25, DELHI FIRE SERVICE RULES 2010: Security deposit

DELHI FIRE SERVICE RULES 2010 - Rule 25

Text of rule 25

Security deposit

25. Security deposit. – (1) Every external trainee shall on admission to a course deposit a sum of rupees one thousand only to the Principal through a bank draft as security deposit if he is allotted accommodation. (2) The security deposit shall be refunded at the end of course after making good any losses to the exchequer caused during the training. 12 Chapter V GENERAL MEASURES FOR FIRE PREVENTION 26. Fire Prevention Wing. Fire Prevention Wing’ in the Fire Service under the charge of a Chief Fire Officer assisted by a Deputy Chief Fire Officer, two Divisional Fire Officers, six Assistant Divisional Fire Officers, twelve Station Officers and one Assistant Law officer,: Provided that the Government may, depending upon work load increase the number of fire officers in any of the categories. (2) Examination of Plans. ilding plans referred to Fire Service by local authority or any other statutory authority from fire prevention and fire safety point of view and issue directives relating to fire prevention and fire safety measures for compliance by the builder, owner or occupier. (3) Assistance in Framing Policies. Fire Prevention Wing shall study the trends in fire accidents in the National Capital Territory of Delhi and assist in framing the policies in the matters connected therewith for the fire prevention and fire safety and similar other matters incidental thereto, requirement and deployment of fire fighting equipment and appliances, planning for new fire stations and prepare training requirements for Fire Service. (4) Study of Laws. to fire prevention and fire safety as contained in other Acts, Statues, Rules and Regulations for the time being in force. 5) Court Matters. Fire Prevention Wing shall, in consultation with the government counsel, defend the cases in various courts of law. (6) Mass Awareness Programs. awareness programs on fire prevention and fire safety and prepare leaflets and other advertisement material in electronic form for distribution to the public free of any charges. 27. Classes of occupancies likely to cause a risk of fire. occupancies for the purposes of sub-section (1) of section 25 of the Act shall be construed to likely cause a risk of fire, namely:- (1) Pandal having seating capacity more than 50 persons or covered area more that 50 square meters. (2) Residential buildings (other than hotels and guest houses) having height more than 15 meters or having ground plus four upper stories including mezzanine floor. (3) Hotels and guest houses having height more than 12 meters having ground plus three upper stories including mezzanine floor. (4) Educational buildings having height more than 9 meters or having ground plus two upper stories including mezzanine floor. (5) Institutional buildings having height more than 9 meters or having ground plus two upper stories including mezzanine floor. (6) All Assembly buildings. (7) Business buildings having height more than 15 meters or having ground plus four upper stories including mezzanine floor. (8) Mercantile buildings having height more than 9 meters or having ground plus two upper stories including mezzanine floor. (9) Industrial buildings having covered area on all floors more than 250 square meters. (10) Storage buildings having covered area on all floors more than 250 square meters. 13 (11) All Hazardous buildings having covered area on all floors more than 100 square meters. (12) Underground Structures. 28. Height of building. ldings for the purposes of sub-section (1) of section 33 and sub-section (1) of section 35 of the Act shall be as specified in rule 27. 29. Minimum standards for fire prevention and fire safety for pandal. minimum standards for fire prevention and fire safety for Pandal for the purposes of sub-section (2) of section 25 shall be in accordance with IS 8758:1993 published by Bureau of Indian Standards, New Delhi and National Building Code of India, 2005 relating to the following matters:- (1) Access to pandal (2) Open space around the pandal. (3) Distance from medium and high voltage electrical wires and hazardous installations. (4) Means of exits. (5) Material of construction. (6) First-aid fire fighting arrangements. (7) Water Storage for fire fighting. (8) Electrical Wiring. (9) Availability of trained fire fighting staff. 30. Form of declaration. The erector of pandal shall, for the purposes of sub-section (2) of section 26 of the Act, make declaration in Form ‘D’ in First Schedule. 31. Removal of encroachments or objects or goods likely to cause a risk of fire or any obstruction to fire fighting. (1) The Sub-Divisional Magistrate having jurisdiction after giving reasonable opportunity under sub-section (2) of section 27 of the Act may order to seize, detain or remove goods or objects under sub-section (3) of section 27 of the Act. (2) The order under sub-rule (1) shall be made in Form ‘E’ of First Schedule and the panchnama shall be made in Form ‘F’ of First Schedule. (3) The notice under sub-section (4) of section 27 the Act shall be made in Form ‘G' of First Schedule. 32. Appointment of Fire Safety Officer under section 29 of the Act. (1) The Director or nominated authority shall issue notice in Form ‘M’ in First Schedule to the owner or occupier or an association of owner and occupiers of buildings or premises identified under section 29 of the Act to appoint a fire safety officer within a period as may be specified in the notice. (2) If the owner or occupier or an association of such owner and occupiers of building or premises fails to comply with the notice issued by the Director or nominated authority under sub-rule (1) the Director shall raise a demand on the owner or occupier or an association of such owner and occupiers of building or premises determined under sub-section (2) of section 31 of the Act and the owner or occupier or an association of such owner and occupiers of building or premises shall deposit the same through bank draft/pay order to the DDO (Headquarters), Delhi Fire Service payable at Delhi within a period of 15 days. (3) In case the owner or occupier or an association of such owner and occupiers of building or premises fails comply with the direction of the Director the same shall be reported to the Sub-Divisional Magistrate having jurisdiction to recover the same as the arrear of land revenue under sub-section (3) of section 31 of the Act. 14 33. Minimum standards for fire prevention and fire safety for buildings. (1) The minimum standards for fire prevention and fire safety for buildings as may be applicable with reference to the height of the building and class of occupancy for the purposes of section 32 and section 35 of the Act shall be as are provided in the building bye-laws or National Building Code of India 2005 relating to the following matters:- (1) Access to building (2 Number, Width, Type and Arrangement of exits. (3) Protection of Exits by means of fire check door (s) and or pressurization. (4) Compartmentation. (5) Smoke Management System. (6) Fire Extinguishers. (7) First-Aid Hose Reels. (8) Automatic fire detection and alarming system. (9) MOEFA. (10) Public Address System. (11) Automatic Sprinkler System. (12) Internal Hydrants and Yard Hydrants. (13) Pumping Arrangements. (14) Captive Water Storage for fire fighting. (15) Exit Signage. (16) Provision of Lifts. (17) Standby power supply (18) Refuge Area. (19) Fire Control Room (20) Special Fire Protection Systems for Protection of special Risks,: Provided that classes of occupancies or buildings or premises for which fire prevention and fire safety measures are not provided in the building bye-laws or National Building Code of India 2005, the Director may require owner or occupier of such occupancies or buildings or premises to provide fire prevention and fire safety measures in accordance with international standards as may be provided by the Fire Prevention Wing,: Provided further that where the Government is of the opinion that it is necessary or expedient so to do, it may, by order, for reasons to be recorded in writing, relax or modify or annul any requirement concerning fire prevention and fire safety measures under these rules with respect to any class of occupancy in any building or premises in special areas or in respect of any building or premises in any area that was constructed or which was under construction prior to the date of enforcement of these rules. (2) Where the Director is of the opinion that it is necessary or expedient so to do, it may, for reasons to be recorded in writing, require the owner or occupier of the buildings or premises to provide additional fire prevention and fire safety measures. 34. Issue of fire prevention and fire safety measures. (1) On receipt of a reference from the local authority or any other statutory authority under clause (s) of section 2 of the Act the Fire Prevention Wing shall issue fire prevention and fire safety measures under these rules to be incorporated in the design of the building for the safety of the occupants. (2) The Fire Prevention Wing may require the owner or occupier to make presentation through Architect (s) on a specified date. (3) The Fire Prevention Wing shall direct the Architect to modify the building plans received under sub-rule (1) above to ensure the compliance of these rules and the architect shall abide by such instructions failing which building plans are liable for rejection. 15 (4) The fire prevention and fire safety measures shall be issued within three weeks from the date of presentation under sub-rule (2) or modification of building plans as may be required under sub-rule (3) if any. 35. Fire Safety Certificate to be issued. authorized by him in this behalf by a general or special order shall issue a Fire Safety Certificate in Form ‘H’ in First Schedule to the owner or occupier of the building or premises with such conditions as may be specified in the Fire Safety Certificate for compliance of fire prevention and fire safety measures as specified under these rules. (2) The application for grant of Fire Safety Certificate shall be made to the Director in Form ‘I’ in First Schedule and shall be accompanied with a certificate from the architect and owner or occupier that all the fire prevention and fire safety measures as required under rule 33 have been incorporated in the building or premises. (3) On receipt of application under sub-rule (2), the building or premises shall be inspected by a team of fire officers to ascertain the availability and operability of the fire prevention and fire safety measures who shall recommend to the Director for grant or refusal of fire safety certificate. (4) On receipt of the recommendations under sub-rule (3) the Director shall grant the fire safety certificate or reject the same for reasons to be recorded in writing and communicated to owner or occupier as the case may be. (5) In case of rejection of application for grant of fire safety certificate under sub- rule (4), a fresh application shall be made by the owner or occupier under sub-rule (2) duly complying with the requirements as communicated under sub-rule (4). (6) The buildings or premises that have already been issued No Objection Certificate for the occupancy of the building or premises shall deemed to have been issued Fire Safety Certificate under rule 35 subject to verification of compliance of fire prevention and fire safety measures on which the No Objection Certificate was issued on the last occasion. 36. Duration of Fire Safety Certificate. rule 35 unless sooner cancelled shall be valid for a period 5 years for residential buildings (other than hotels) and 3 years for non-residential buildings including hotels from the date of issue. 37. Renewal of Fire Safety Certificate. Fire Safety Certificate granted under rule 35 as valid under rule 36 shall be made to the Director in Form ‘I’ in First Schedule along with a copy of the Fire Safety Certificate six months before the expiry of the Fire Safety Certificate. (2) On receipt of application under sub-rule (1) the Nominated Authority shall inspect the building or premises to verify the compliance of rules and forward the report of the compliance or otherwise to the Director. (3) On receipt of report under sub-rule (2) the Director or any other officer authorized by him in this behalf by a special or general order renew the Fire Safety Certificate for a period specified under rule 36 or reject the application duly recording the reasons therefor. 38. Liability to maintain fire safety measures. premises, as the case may be, shall maintain the fire prevention and fire safety measures provided in the building or premises at all times in best repairs for use by the occupants or members of Fire Service or both in the event of an out break of fire. (2) The occupier of the building or premises or the Fire Safety Officer appointed under section 29 of the Act, as the case may be, shall declare every year in Form ‘J’ in First Schedule that fire prevention and fire safety measures provided in the building or premises as the case may be are in best repairs. 16 (3) It shall be lawful for the Director, or Nominated Authority to enter and inspect the building or premises, as the case may be, with a view to verifying the correctness of the declaration made under sub-rule (2) above and to point out the shortcomings, if any, with directions to remove them within a specified time. If the directions of the inspecting officer are not complied within the time so given, the inspecting officer with the previous approval of the Director shall declare the building or premises unfit from fire safety point of view and direct the local body or any other authority concerned to disconnect the electricity and water supply to the building or the premises, as the case may be, and the local body or the other authority shall comply with the directions of the inspecting officer. (4) The occupier of the building or premises or the Fire Safety Officer appointed under section 29 of the Act, who falsely declares under sub-rule (2), shall be deemed to be in default. 39. Time for Completion of measures. indicate the time not exceeding 90 days within which fire prevention and fire safety measures should be provided as per the requirements of sub-section (1) of section 34 of the Act. (2) The Director may review the time allowed by the Nominated Authority under sub-rule (1) above and grant extension of time once or several times if he is satisfied with the progress of the work subject to maximum of 180 days. (3) The Fire Safety Certificate issued under rule 35 shall remain suspended from the date of notice of the Nominated Authority issued under sub-rule (1) till the compliance is made to the satisfaction of the Director or the Nominated Authority and this shall be duly recorded on the Fire Safety Certificate. (4) The occupancy of the building or premises during the time allowed for completion of work under sub-rule (1) and sub-rule (2) above shall be at the risk and liability of the owner or occupier. 40. Cancellation of Fire Safety Certificate. (1) If the owner or occupier fails to comply with the direction given under rule 39 within the specified time, the Director or any other officer authorized by him in this behalf may, without prejudice to any other action under the Act or rules, after giving owner or occupier an opportunity to show cause, why such an order should not be passed by an order in writing stating the reasons therefor, cancel the Fire Safety Certificate issued under rule 35. (2) The owner or occupier of the building or premises whose fire safety certificate has been cancelled by the Director or any other officer authorized by him in this behalf under sub- rule (1), may within 90 days of the receipt of a copy of the order by him prefer an appeal in the manner laid down under rule 42 to the Appellate Authority who may after giving the owner or occupier an opportunity of being heard, confirm, reverse or modify such order. 17 Chapter VI

Previous and next

All provisions of DELHI FIRE SERVICE RULES 2010

Questions people ask

Is rule 25 of DELHI FIRE SERVICE RULES 2010 still in force?

No repeal of DELHI FIRE SERVICE RULES 2010 is recorded.