Rule 123, Punjab Building and Other Construction Workers ( (Regulation of Employment and Conditions of Service) Rules, 2008.) Rules, 2008: Ventilation
Punjab Building and Other Construction Workers ( (Regulation of Employment and Conditions of Service) Rules, 2008.) Rules, 2008 - Rule 123
Text of rule 123
Ventilation
123. Ventilation.—The employer shall ensure at a construction site of
a building or other construction work that all working areas in a free air tunnel
are provided with ventilation system as approved by the Chief Inspector and the
fresh air supplied in such tunnel, is not less than six cubic metres per minute for
each building worker employed underground in such a tunnel and the free air-
flow movement inside such tunnel is not less than nine cubic metres per minute.