Rule 126, The West Bengal Municipal (Building) Rules, 2007: Syphon-trap and Anti-syphonage Pipe
The West Bengal Municipal (Building) Rules, 2007 - Rule 126
Text of rule 126
Syphon-trap and Anti-syphonage Pipe
126. Syphon-trap and Anti-syphonage Pipe.—
(1) Every connected privy and connected urinal shall be provided with a syphon trap which shall be proof against
syphonage.
(2) In all cases where a connecter privy or connected urinal is more than one storey high, an anti-syphonage pipe
having an internal diameter of not less than fifty millimetres shall be provided, and such pipe shall be carried independently
to a height of at least sixty centimetres above the roof of the privy or urinal or the roof of the building in which such privy
or urinal is situated.
(3) No 'container' or other similar fittings shall be placed under the pan of a connected privy or connected urinal
and no trap of the kind known as a 'D trap' shall be used with any such privy or urinal.
Previous and next
← Rule 125Flushing of connected privies and urinalsRule 127 →Soil pipe for connected privies and connected urinals
All provisions of The West Bengal Municipal (Building) Rules, 2007
Questions people ask
Is rule 126 of the West Bengal Municipal (Building) Rules, 2007 still in force?
No repeal of the West Bengal Municipal (Building) Rules, 2007 is recorded.