Rule 91, The West Bengal Municipal (Building) Rules, 2007: Plumbing services
The West Bengal Municipal (Building) Rules, 2007 - Rule 91
Text of rule 91
Plumbing services
91. Plumbing services.—
(1) The planning, design, construction and installation of water supply, drainage and sanitation, and gas supply
system shall be in accordance with the provisions of Water Supply, Drainage and Sanitation, Gas Supply or Plumbing
Services, of the latest edition of National Building Code of India. Septic tank, pits of pit privy shall be so located in a
premises or holding, that the same is easily accessible from the means of access to the plot.
(2) The underground reservoir shall be constructed in such a way that the manhole portion must be raised 300 mm.
or more above ground level to avoid surface contamination. The inlet supply pipe shp.11 always be kept above the higher
level of the stored water surface.
4.- PART I] THE KOLKATA GAZETTE, EXTRAORDINARY, FEBRUARY 14, 2007 45
(3) The depth of the Underground Water Reservoir or Septic Tank or Inspection Pits or manholes shall not be more
than the shallowest foundation depth and the minimum distance between edge of foundation and such underground
structure shall not be less than 50% width of the underground structure.
Note: All other services, which are not mentioned in this part, shall conform to the provisions of the latest edition of
National Building Code of India.
Previous and next
All provisions of The West Bengal Municipal (Building) Rules, 2007
Questions people ask
Is rule 91 of the West Bengal Municipal (Building) Rules, 2007 still in force?
No repeal of the West Bengal Municipal (Building) Rules, 2007 is recorded.