Rule 86, The West Bengal Municipal (Building) Rules, 2007: Structural design
The West Bengal Municipal (Building) Rules, 2007 - Rule 86
Text of rule 86
Structural design
86. Structural design.—
(1) The structural design of foundation, masonry timber, plain concrete, reinforced concrete, pre-stressed concrete
and structural steel shall be in accordance with the provisions of the latest edition of National Building Code of India
(NBCI) and/or Bureau of Indian Standard (BIS).'
(2) For earthquake protection, a structural engineer shall design the structure taking into consideration the Indian
standard codes as given below:—
(i) BIS : 1893 — 2002 "Criteria for Earthquake Resistant Design of Structures (Fifth Revision)",
(ii) BIS : 13920-1993 "Ductile Detailing of Reinforced Concrete Structures subjected to Seismic Forces —
Code of Practice",
(iii) BIS : 4326 — 1993 "Earthquake Resistant Design and Construction of Buildings — Code of Practice (Second
Revision)",
(iv) BIS : 13828-1993 "Improving Earthquake Resistance of Low Strength Masonary Buildings — Guidelines"
(v) BIS : 13827 — 1993 " Improving Earthquake Resistance of Earthen Buildings — Guidelines",
(vi) BIS :13935-1993 "Repair and Seismic Strengthening of Buildings — Guidelines":
Provided that the provisions of National Building Code is also to be taken into consideration for design purpose.
Previous and next
← Rule 85Requirements of special occupancies under any other law in forceRule 87 →Quality of materials and workmanship
All provisions of The West Bengal Municipal (Building) Rules, 2007
Questions people ask
Is rule 86 of the West Bengal Municipal (Building) Rules, 2007 still in force?
No repeal of the West Bengal Municipal (Building) Rules, 2007 is recorded.