Rule 18, TAMIL NADU WINE (MANUFACTURE) RULES, 2006: Arrangement of Manufacturing Units
TAMIL NADU WINE (MANUFACTURE) RULES, 2006 - Rule 18
Text of rule 18
Arrangement of Manufacturing Units
18. Arrangement of Manufacturing Units:-
(1) The building used for the manufactory shall be
constructed with brick or stone and the roof of the
building shall be of reinforced cement concrete or Madras
Terrace or shall be of non-inflammable material.
(2) All windows, ventilators and sky lights in the building
other than those in the ware-house and store room shall
be fitted with rods spaced not more than 10 centimeters
apart, centre, to centre. All the windows, ventilators and
sky lights in the ware-house and store room shall be
covered with galvanized wire net or square mesh, not
more than ½ centimeters apart.
(3) All the doors which are to be fitted with excise ticket locks
shall be free from tampering of the hinges from outside.
(4) All doors fitted to the building shall open outwards.
(5) There shall be no thatched shed with in the manufactory
or ware house compound.
(6) All the openings in the external walls intended for the
efflux of waste water shall be covered with grills affixed
to the wall.
(7) There shall be separate rooms or compartments isolated
by grills embedded in cement concrete provided for the
following purposes and no such room or compartment
shall be used for more than one of the said purpose:-
(a) manufacturing;
(b) storage of wine in build and bottling operation;
(c ) Storage of wine in sealed bottles, casks,
barrels and other receptacles.
(8) There shall be separate tanks for fermentation, storage
and fortification.
12
(9) Each tanks used for fermentation, storage or
fortification shall be marked with a permanent serial
number and the capacity of such tanks accurately
gauged by the Department of Weights and Measures
under the Standard of Weights and Measures
(Enforcement) Act, 1985 (Central Act 54 of 1985).
(10) Every room or compartment in the manufactory shall
be well-ventilated and shall bear on the outside a sign
board denoting the purpose for which the
compartment or room is used for.
(11) All gas and electric connections with the manufactory
shall be fixed in such a manner as to ensure that the
supply of gas or electricity can be cut off and all the
regulator or switch shall be securely locked at the end
of each day‟s work.
(12) Unless, otherwise directed by the Commissioner in
writing, there shall be only one entrance and one exit
to the manufactory and one emergency exit and one
door to each of its rooms or compartments. All the
doors which are provided shall be secured with excise
ticket locks. The emergency exit doors shall be kept
closed with the excise ticket locks and shall be
opened only on emergency occasion.
(13) Necessary air condition arrangements shall be made
within the manufacturing unit as may be specified by
the Commissioner from time to time.
(14) Necessary Fire Extinguishing equipment shall be kept
in the manufacturing unit.