2. Definitions.- In these rules, unless the context otherwise requires,-
(a) "Act" means the Building and Other Construction Workers (Regulation of
Employment and Conditions of Service) Act 1996 (Central Act 27 of 1996);
(b) "access" or "egress" means passageways, corridors, stairs, platforms,
ladders and any other means to be used by a building worker for normally entering or leaving
the workplace or for escaping incase of danger;
(c) "approved" means approved in writing by the chief inspector of building
and other construction works or the Government as the case may be;
(d) "base plate" means a plate for distributing the load from a standard in the
case of metal scaffolds;
(e) "bay" in relation to scaffolds, means that portion of the scaffold between
horizontal and vertical supports whether standards or supports from which the portion is
suspended, which are adjacent longitudinally;
(f) "brace" means a member incorporated diagonally in a scaffold for stability;
officers
Typewritten text
1 vide the Tamil Nadu Government Gazette,Pt.III, Sec.1 (a) (Supplement), Issue No. 47, dated the 6th
December, 2006, at p.1.
officers
Typewritten text
THE
officers
Typewritten text
1[
-2-
(g) "bulkhead" means an airtight structure separating the working chamber
from free air or from another chamber under a lower pressure than the
working pressure;
(h) "caisson" means an air and watertight chamber in which it is possible for
men to work under air pressure greater than atmospheric pressure at sea
level to excavate material below water level;
(i) "cofferdam" means a structure constructed entirely or in part below the level
of the water table in the ground and intended to provide a place for work that
is free of water;
(j) "competent person" means a person so approved by the Chief Inspector of
Inspection of building and construction, possessing adequate qualification,
experience and skill as specified under Rule 2-A of the Tamil Nadu
Factories Rules, 1950 for the purposes of testing, examination or annealing
and certification of lifting appliances, lifting gears, wire ropes or pressure
plant or equipment;
(k) ''compressed air" means air mechanically raised to a pressure higher than
atmospheric pressure at sea level;
(1) "construction site" means any site at which any of the processes or
operations, related to building or other construction work, are carried on;
(m) "conveyor" means a mechanical device used in building or other
construction work for transport of building material, articles, or packages or
solid bulk from one point to another point:
(n) "danger" means danger of accident or of injury or to health;
(o) "decanting" means the rapid decompression of persons in a man-lock to
atmospheric pressure at sea level followed promptly by their recompression
in a decant lock, where they are then decompressed according to the
appropriate decompression table in accordance with approved
decompression procedures:
(p) "demolition work" means the work incidental to or connected with the total
or partial dismantling or racing of a building or a structure other than a
building and includes the removing or dismantling of machines or other
equipment;
(q) "excavation" means the removal of earth, rock or other material in
connection with construction or demolition work;
(r) "falseworks" means the structural supports and bracing for formworks or forms;
(s) "flash point" means the minimum liquid temperature at which a spark or flame
causes an instantaneous flash in the vapour space above the liquid;
(t) "frame or modular scaffold" means a scaffold manufactured in such a way that the
geometry of the scaffold is pre-determined and the relative spacings of the
principal members are fixed;
-3-
(u) "Government" means the State Government;
(v) "guard rail" means a horizontal rail secured to uprights and erected along the
exposed sides of scaffolds, floor openings, runways and gangways to prevent
persons from falling;
(w) "hazard" means danger or potential danger;
(x) "hazardous substance" means any substance which due to its explosiveness,
inflammability. radio-activity, toxic or corrosive properties, or other similar
characteristics, may,-
(i) cause injury; or
(ii) affect adversely the human system; or
(iii) cause loss of life or damage to property on work-environment, while handling,
transporting or sorting and classified as such under the national standards or in case such
national standards do not exist to the generally accepted international standards;
(y) "high pressure air" means air used to supply power to pneumatic tools and
devices;
(z) "independent tied scaffold" means a scaffold, the working platform of which is
supported from the base by two or more rows of standards and which apart from
the necessary ties stands completely free of the building;
.
(za) "ledger" means a member spanning horizontally and tying scaffolding
longitudinally and which acts as a support for putlogs or transoms;
(zb) "lifting appliance" means a crane, hoist, derrick, winch, gin pole, sheer legs.
jacks. pulley block or other equipment used for lifting materials, objects or building worker;
(zc) "lifting gear" means ropes, chains, hooks, slings and other accessories of a "lilting
appliance":
(zd) " lock attendant" means the person in charge of a man-lock or medical lock and
who is immediately responsible for controlling the compression, recompression or
decompression of persons in such locks:
(ze) "low pressure air" means air supplied to pressurise working chambers and man-
locks and medical locks;
(zf) "magazine" means a place in which explosives are stored or kept, whether above
or below ground:
(zg) "man-lock" means any lock, other than a medical lock. used for the compression
or decompression or persons entering or leaving a working chamber;
-4-
(zh) "material hoist" means a power or manually operated and suspended platform or
bucket operating in guide rails and used for raising or lowering material exclusively and
operated and controlled from a point outside the conveyance;
(zi) "materials lock" means a chamber through which materials and equipments pass
from one air pressure environment into another;
(zj) "medical lock" means a double compartment lock used for the therapeutic
recompression and decompression of persons suffering from the ill-effects of decompression;
(zk) "national standards" means standards as approved by Bureau of Indian Standards
and in the absence of such standards of Bureau of Indian Standards, the standards approved
by the Government for a specific purpose;
(zl) "outrigger" means a structure projecting beyond the facade of a building with the
inner end being anchored and includes a cantilever or other support;
(zm) "plant or equipment" includes any plant, equipment, gear. machinery, apparatus
or appliance, or any part thereof:
(zn) "pressure" means air pressure in bars above atmospheric pressure;
(zo) "pressure plant" means the pressure vessel along with its piping and other fittings
operated at a pressure greater than the atmospheric pressure;
(zp) "putlog" means a horizontal member on which the board, plank or decking of a
working platform are laid:
(zq) 'responsible person' means a person appointed by the employer to be responsible
for the performance of specific duty or duties and who has sufficient knowledge and
experience and the requisite authority for the proper performance of such duty or duties;
(zr) "reveal tie" means the assembly tube and a fittings tube used for tightening
between two opposite surfaces:
(zs) "right angle coupler" means a coupler other than a swivel or putlog coupler used
for connecting tubes at right angles:
(zt) "rock bolt" means a mechanical expansion bolt or a bolt used with cementations or
resin anchoring system which is set in drilled hole in the arch or wall of a tunnel to improve
rock competency;
(zu) "roofing bracket" means a bracket used in sloped, roof construction and having
sharp points or other means for fastening to prevent slipping;
(ZV) "safety screen" means an air and water tight diaphragm placed across the upper
part of a compressed air tunnel between the face and bulkhead, in order to prevent flooding
the crown of the tunnel between the safety screen and the bulkhead to provide a safe means
of refuge and exit from a flooding or flooded tunnel;
(zw) "safe working load", in relation to an article of lifting gear or lifting appliance,
means the load which is the maximum load that may be imposed on such article or appliance
with safety in the normal working conditions as assessed and certified by a competent person;
(zx) "scaffold" means any temporarily provided structure on or from which building
workers perform work in connection with building or other construction work to which these
-5-
rules apply, and any temporarily provided structure which enables building workers to obtain
access to or which enables materials to be taken to any place at which such work is
performed, and includes any working platform, gangway, run. ladder or step-ladder (other
than a ladder or step-ladder which does not form part of such structure) together with any
guardrail, toe board or other safeguards and all fixings, but does not include lifting appliance
or a lifting machine or a structure used merely to support such an appliance or such a-
machine or to support other plant or equipment;
(zy) "schedule" means a schedule appended to these rules;
(zz) "segment" includes cast iron or precast concrete segmented structure formed to the
curvature of the tunnel cross-section and used to support the ground surrounding the tunnel;
(zza) "service shaft" means a shaft for the passage of building workers or materials to
or from a tunnel under construction:
(zzb) "shaft" means an excavation having a longitudinal axis at an angle greater than
forty five degree from the horizontal,—
(i) for the passage of building workers on materials to or from a tunnel; or
(ii) leading to an existing tunnel:
(zzc) "shield" means a movable frame which supports the working face of a tunnel and
the ground immediately behind it and includes equipment designed to excavate and support
the excavated areas in a tunnel:
(zzd) "sole plate" means a member used to distribute the load from the base plate or the
standard of wooden scaffolds to the supporting surface;
(zze) "sound or good construction" means construction conforming to the relevant
national standards or in case such national standards do not exist, to other generally accepted
international engineering standards or code of practices;
(zzf) "sound or good material" means materials of a quality confirming to the relevant
national standards or in case such national standards do not exist, to other generally accepted
international engineering standards or code of practices
(zzg) "standard" means a member used as a vertical support or column in the
construction of scaffolds which transmits a load to the ground or to the solid construction;
(zzh) "standard safe operating practices" means the practice followed in building and
other construction activities for the safety and health of workers and safe operation of
machinery and equipment used in such activities and such practices conforms to all or any of
the following, namely;-
(i) relevant standards approved by Bureau of Indian Standards;
(ii) national building code:
(iii) manufacturer's instructions on safe use of equipment and machinery:
-6-
(iv) code of practice on safety and health in construction industry
published by International Labour Organisation and amended from
time to time:
(zzi) "State" means the State of Tamil Nadu;
(zzj) "steel rib" includes all steel beams and other structural members shaped to
conform to the requirements of a particular tunnel cross section used for the
purpose of supporting and stabilising the excavated areas:
(zzk) "suspended scaffold" means a scaffold suspended by means of ropes or chains
and capable of being raised or lowered but does not include a boatswain's chair or
similar appliance;
(zzl) "testing establishment" means an establishment with testing and examination
facilities, as approved by the Government for carrying out testing, examination, annealing or
similar other test or certification of lifting appliances or lifting gear or wire rope as required
under these rules;
(zzm) "tie" means an assembly used to connect a scaffold to a rigid anchorage;
(zzn) "toe board" means a member fastened above a working platform, access, landing,
access way, wheel barrow run, ramp or other platform to prevent building workers and
materials falling therefrom:
(zzo) "transom" means a member placed horizontally and used to tie transversely one
ledger to another, or one standard to another in an independent tie scaffold;
(zzp) "trestle scaffold" includes a scaffold in which the supports for the platform are
any of the following which are self-supporting, namely:-
(i) split heads;
(ii) folding:
(iii) step-ladder:
(iv) tripods: or
(v) movable contrivances similar to any of the foregoing:
(zzq) "tubular scaffold" means a scaffold constructed from tubes and couplers;
(zzr) "tunnel" means a subterranean passage made by excavating beneath the over-
burden into which a building worker enters or is required to enter to work;
(zzs) "underground" means any space within the confines of a shaft, tunnel, caisson or
cofferdam:
-7-
zzt) "vehicle" means a vehicle propelled or driven by mechanical or electrical power
and includes a trailer, traction engine, tractor, road-building machine and transport
equipment:
(zzu) "working chamber" means the part of the construction site where work in a
compressed air environment is carried out. but does not include a man-lock or medical lock:
(zzv) "working platform" means a platform which is used to support building workers
or materials and includes a working stage;
(zzw) " working pressure" means pressure, in working chamber, to which building
worker is exposed: and
(zzx) " workplace" means all places where building workers are required to be present
or to go for work and which are under the control of an employer.
3. Interpretation of words not defined-Words and expressions not defined in these rules but
defined or used in the Act shall have the same meaning as assigned to them in the Act.
Previous and next
Questions people ask
Is rule 2 of Tamil Nadu Building And Other Construction Workers (Regulation Of Employment And Conditions Of Service) Rules,2006 still in force?
No repeal of Tamil Nadu Building And Other Construction Workers (Regulation Of Employment And Conditions Of Service) Rules,2006 is recorded.