48. Electrical hazards. - (1) Before commencement of any building or other construction work, the
employer shall take adequate measures to prevent any worker from coming into physical
contact with any electrical equipment or apparatus, machines or live electrical circuit which
may cause electrical hazard during the course of his employment at a building or other
construction work.
25
(2) The employer shall display and maintain suitable warning signs at conspicuous places at a
building or other construction work in Hindi and in a local language understood by the
majority of the building workers.
(3) In workplaces at a building or other construction work where the exact location of
underground electric power line is not known, the building workers using jack hammers,
crow bars or other hand-tools which may come in contact with a live electrical line, shall
be provided by the employer with insulated protective gloves and foot-wear of the type in
accordance with the national standards.
(4) The employer shall ensure that, as far as reasonably practicable, no wiring which may
come in contact with water or which may be mechanically damaged is left on ground or
floor at a building or other construction work.
(5) The employer shall ensure that all electrical appliances and current carrying equipment
used at a building or other construction work are made of sound material and are properly
and adequately earthed.
(6) The employer shall ensure that all temporary electrical installations at a building or other
construction work are provided with earth - leakage circuit breakers.
(7) The employer shall ensure that all electrical installations at a building or other
construction work comply with the requirements of any law for the time being in force.