Rule 7, The Tamil Nadu Lifts and Escalators Rules,1997: Terms and conditions of licence for working of lift or escalator
The Tamil Nadu Lifts and Escalators Rules,1997 - Rule 7
Text of rule 7
Terms and conditions of licence for working of lift or escalator
7. Terms and conditions of licence for working of lift or escalator.- Every lift or
escalator shall be operated, subject to the following terms and conditions, namely,-
(1) The licensee shall forthwith report to the Inspector on any defect in the
operation of lift or escalator;
(2) The licensee shall not carry out any additions or alterations to a lift or an
escalator erected without obtaining permission in that behalf from the
Inspector as required under these rules;
(3) The licensee shall not use the lift or escalator which is not in a safe condition
and shall be solely responsible for the safe maintenance of lift or an
escalator, so that these rules are always complied with;
(4) The maintenance of the lift or an escalator shall be done by a manufacturer
of lifts or escalators or company of Electrical and Mechanical Engineers
approved by the Inspector;
(5) The licensee shall produce test reports obtained from the competent person
authorised under rule 14 for the lift or escalator installation at the end of
every year from the date of grant or renewal of licence;
(6) No other person shall wilfully interfere with any mechanism of the lift or
escalator;
5
(7) Every lift or escalator operator, if appointed in case of manually operated lift
or escalator, must have attained the age of eighteen years and shall be a
person who has been trained in the correct operation of the lift or escalator;
(8) When a lift or escalator erected at any place ceases to be used as such, the
owner shall either remove it or maintain it in safe mechanical condition after
disconnecting it entirely from the electric supply; all gates and doors shall be
securely locked, so as to prevent the accidental entry to lift well or escalator
and to prevent inadvertent use;
(9) All electrical works in connection with erection of lift or escalator shall be
carried out in accordance with the provisions of the Electricity Act, 2003
(Central Act 36 of 2003) and the rules made there under and the Central
Electricity Authority (Measures Relating to Safety and Electric Supply)
regulations, 2010;
(10) All apparatus and components of lifts or escalators shall be of sufficient
ratings and of sufficient mechanical strength for the duty which they may be
required to perform under the environmental conditions of installation and
shall be constructed, installed, protected, worked and maintained to ensure
safety of human beings and property;
(11) The code of practices prescribed by the Bureau of Indian Standards including
National Electrical Code shall be followed in respect of the lift or an
escalator and their installation and wherever relevant specification of Bureau
of Indian Standard does not exist, they shall conform to the relevant
International Standards;
(12) The material and apparatus used shall conform to the prescribed
specifications of Bureau of Indian Standards and wherever relevant
specification of Bureau of Indian Standard does not exist, they shall conform
to the relevant International Standards; and
(13) The lift or escalator shall be tested in the manner specified in specifications
and Codes of Bureau of Indian Standards and wherever relevant specification
of Bureau of Indian Standard does not exists, they shall conform to the
relevant International Standards;”
Previous and next
All provisions of The Tamil Nadu Lifts and Escalators Rules,1997
Questions people ask
Is rule 7 of the Tamil Nadu Lifts and Escalators Rules,1997 still in force?
No repeal of the Tamil Nadu Lifts and Escalators Rules,1997 is recorded.