LawGrids logoLAWGRIDS.ORG

Annexure II, The Tamil Nadu Lifts and Escalators Rules,1997: ANNEXURE-II

The Tamil Nadu Lifts and Escalators Rules,1997 - Annexure II

Text of annexure II

ANNEXURE-II

ANNEXURE-II [See rule 13(2)] AUTHORISATION FOR MAINTENANCE, INSPECTION AND TESTING OF LIFTS OR ESCALATORS. 1. Requirements for authorization. An application for authorization for maintenance, inspection and testing of lifts or escalator, as the case may be, under the provisions of rule 13 of The Tamil Nadu Lifts and Escalators Rules, 1997 may be made in the prescribed Form-“J” along with the prescribed fee, fulfilling the following criteria. (i) shall have an independent office premises with an independent telephone connection within the State of Tamil Nadu. (ii) shall have to produce a certificate from any nationalized bank to the effect that he is solvent to the extent of rupees three lakhs. (iii) shall have in his regular employment following the minimum staff (copies of appointment letter, proof of academic qualification and field of experience to be enclosed). (a) At least one engineer possessing (a) a degree in mechanical engineering or its equivalent qualification from the recognized university or institution and having an experience of at least five years in the field of elevators or escalators, as the case may be or (ii) a diploma in mechanical engineering from a recognized Institute and having an experience of at least eight years in the field of elevators or escalators as the case may be. (b) At least one engineer possessing (i) a degree in electrical and electronics engineering or its equivalent qualification from the recognized university or institution and having an experience of atleast five years in the field of elevators or escalators as the case may be or (ii) a diploma in electrical engineering from a recognized Institute and having an experience of at least eight years in the field of elevators or escalators as the case may be. (c) At least one person possessing a certificate in the trade of electrical or electronics from the Industrial Training Institute or any other recognized Institution and possessing “Wireman competency certificate” issued by Tamil Nadu Electrical Licensing Board and having an experience of at least five years in the field of Lifts or escalators, as the case may be. (d) Maintenance staff of one Industrial Training Institute electrician, one Industrial Training Institute fitter and one helper for every fifty lifts/ escalators to be maintained in a year (e) Clerk/attendant round the clock having the presence in the service station for responding to the complaint calls from the owners. Provided that the employment of such clerk/attendant shall not be necessary during night 13 hours if facilities for better communication like mobile phone, pager system etc. are available during such hours. (iv) Shall have a workshop in his own possession within the State of Tamil Nadu equipped with minimum area of 100 square meters with independent facility and telephone and separate power connection of at least 15 HP Such workshop shall be equipped with the following minimum machineries and testing instruments either stationary or portable. (a) Lathe machine. (b) Drill machine (c) Welding machine of 5 kVA or above. (d) Hacksaw machine (e) Chain pulley block of 3 tonne capacity. (f) Standard weight trolley (g) Clip-on meter for measurement of voltage, current etc. (h) Tachometer (i) Megger (j) Earth tester Provided that when the authorized person is having his own manufacturing unit within the State of Tamil Nadu, he shall not be required to have a separate workshop but he shall be required to have the minimum machineries and instruments as mentioned above. (v) shall have necessary safety gadgets, like safety belts and head gears for entire staff engaged in the work of maintenance. (vi) shall have suitable means of transportation at his disposal for transportation of material. Provided that a staff register and the relevant records related to maintenance shall be maintained by such person and the same shall be produced for verification as and when directed by the Chief inspector. The specimens of such staff register as well as the guide lines to be followed for maintaining the records of maintenance shall be prescribed by the Chief Inspector. 2. Grant of Certificate of authorization: (1) The Chief Inspector may after such enquiries and tests as may be considered necessary grant a certificate of authorization in Form “M’’, in case of lifts and in Form “N’’, in case of escalators set out in this annexure to an applicant who fulfill the above requirements. (2) The Chief Inspector may after giving an opportunity to the persons authorized under section 10(3) of the Act of being heard, cancel the authorisation, If the person has reason to believe that he - (i) has violated any condition stipulated in the authorisation; or 14 (ii) has acted in a manner inconsistent with the intent or the purpose of this Act or the rules made thereunder; or has omitted to act as required under the Act and rules made thereunder or found to be guilty of negligence, incompetence; or (iii) for any other reason to be recorded in writing. 3. Documents to be enclosed herewith along with renewal application: Every authorization granted under rule 14 shall be valid for two year. The authorization may be renewed on an application made in that behalf to the Chief Inspector along with following documents before three month from the date of expiry of licence. (a) Certificate of Authorization in original. (b) A receipted challan in original (c) A copy of the staff register attested by a Gazetted Officer. (d) Details of lifts maintained during the validity period of authorisation. (e) A certificate from any nationalized bank to the effect that the applicant continues to be solvent to the extent of Rupees Five lakhs. (f) A copy of the application made, if any, for renewal of the registration granted under the Factories Act, 1948. (g) Updated list of machineries, equipment and testing instruments in possession. (h) Details of safety gadgets for staff. (i) Details of vehicles in possession for transportation of materials. 15 “FORMS FORM ‘A’ (see rule 3 ) APPLICATION FOR PERMISSION * TO INSTALL* ------------------ A LIFT OR AN ESCALATOR * TO MAKE ADDITIONS AND ALTERATIONS TO To The Inspector of Lifts and Escalators. 1 Full Name and Address of the Applicant 2 Contact Number and E- mail id 3(a) Address of the premises where the Lift or Escalator *is to be * Installed *make additions or alterations (b) Approval reference of Urban Local Body concerned for the Building Plan (Copy of approval letter, approved plan and elevation drawings to be enclosed). 4 Whether a licence has been previously granted (details to be given). 5 Type and Make of Lift or Escalator* (A sketch of the erection plans as per rule 3 shall be attached). 6 (a)The rated maximum speed of the Lift; The Maker’s or Designer’s rated capacity in Weight (in kg).* (b)The rated speed of Escalator (m/sec); The Maker’s or Designer’s rated capacity (in persons /hr).* 7 The maximum number of passengers in addition to the lift operator which the lift can carry* 8 The total weight of the lift car carrying the maximum load (Weight of car plus maximum allowable load)* 9 The weight of the counter-weight for Lift (kg )* 16 10 System of roping: (The number, description, weights (kgs) and size (in Sq.mm) of the supporting ropes of the Lift )* 11 Lift *:The depth of the pit from lowest part of the car when at the lowest floor (in mms) Escalator*:The depth of the pit (both upper and lower) (in mms) 12 Details of the construction of the Overhead Arrangement with weight (in kg.) and size (in mms) of beams or any other arrangement * 13 Total Number of landings of the Lift* 14 (a)Angle of inclination of escalator* (b)Vertical rise of the escalator (in mms) (c)Width of the escalator (d) Number of flat steps 15 (a)Type of balustrading in escalator: (b) Height of balustrade 16 Details of (a) hand rails (b) steps treads (c) landing (d)comb plates (e) trusses or girders, Skirting brush (f)step wheel tracks in escalator 17 (a)Drive chain factor of safety whether all the electrical and mechanical safety devices as per standards provided in the escalator (b) Illumination level provided for comb lights ( in lux) 18 Details of fee paid Date: Signature of the Applicant. Encl: 1.Original remitted chalan/e-receipt. 2. Copy of approval obtained from the local body for the building. 3. Drawings of Lift or Escalator*Installation (Both Electrical and Mechanical) ---------------------------------------------------- * Strike off whichever is inapplicable. 17 FORM ‘B’ (See rule 3(2)) Government of Tamil Nadu Letter No………………… Dated ____________ To ……………………….. ……………………….. ………………………... ……………………….. Sub: Permission for * erection of Lift or Escalator * or making additions or alterations of existing Lift or Escalator *at the …………………….. Granted. *Under sub-section (3) in section 4 of the Tamil Nadu Lifts and Escalators Act,1997 (Tamil Nadu Act 35 of 1997), permission is hereby granted to erect Lift or Escalator * under section 9 of the Tamil Nadu Lifts and Escalators Act,1997 (Tamil Nadu Act 35 of 1997), *permission is hereby granted to make additions or alterations of existing Lift or escalator * at the premises ……………………………………………… owned by ……………………… subject to the provisions of the Tamil Nadu Lifts and Escalators Act,1997 (Tamil Nadu Act 35 of 1997) and the Tamil Nadu Lifts and Escalator Rules, 1997. The permission shall be valid for a period of six months from the date on which it is granted. The lift or Escalator* shall not be worked until a licence is granted by the Inspector of Lifts and Escalators for working of the lift or escalator in accordance with rule 4 of the Tamil Nadu Lifts and Escalator Rules, 1997. Signature------------------------------------------------- The Inspector of Lifts and Escalators, Government of TamilNadu * Strike off whichever is inapplicable. 18

Previous and next

All provisions of The Tamil Nadu Lifts and Escalators Rules,1997

Questions people ask

Is annexure II of the Tamil Nadu Lifts and Escalators Rules,1997 still in force?

No repeal of the Tamil Nadu Lifts and Escalators Rules,1997 is recorded.