Section 92, The Building and other Construction Workers‘ (Regulation of Employment and Conditions of Service) Act, 1996
The Building and other Construction Workers‘ (Regulation of Employment and Conditions of Service) Act, 1996 (27 of 1996) - Section 92
Text of section 92
92. Mobile asphalt layers and finishers:-The employer shall ensure at a
construction site of a building or other construction work that—
(a) a mixture elevator is within a wooden or sheet metal enclosure
with a window for observation, lubrication and maintenance;
(b) bitumen scoops have adequate covers;
56 The Building and Other Construction Workers‘ Rule 93
(Regulation of Employment and Conditions of Service)
Central Rules, 1998
(c) when asphalt plants are working on a public road, adequate
traffic control is established on such road and the building
workers working with such plant are provided with reflecting
jackets;
(d) a sufficient number of fire extinguishers are kept in readiness on
such work place where fire hazards may exist;
(e) the materials are loaded on the elevator after the drying drain
has warmed up of such elevator;
(f) no open light is used for ascertaining the level of asphalt;
(g) inspection opening is not opened till there is a pressure in the
boiler which may cause injury to a building worker.
Previous and next
Questions people ask
Is section 92 of the Building and other Construction Workers‘ (Regulation of Employment and Conditions of Service) Act, 1996 still in force?
No repeal of the Building and other Construction Workers‘ (Regulation of Employment and Conditions of Service) Act, 1996 is recorded.