82. Use of runways and ramps by building worker:-The employer shall
ensure at a construction site of a building or other construction work that—
(a) runway or ramp provided for use by building workers is not less
than four hundred and thirty millimetres in width and is
constructed of not less than twenty-five millimetres thick
planking or any other material of adequate strength to withstand
the required load supported substantially in relation to the span
and braced of such runway or ramp and design and construction
of such runway or ramp is in accordance with the relevant
national standards;
(b) every runway or ramp provided for use of building workers
located more than three metres above the floor or ground is on
open sides provided with a guard rail of adequate strength and
height of not less than one thousand millimetres.