Section 59, The Building and other Construction Workers‘ (Regulation of Employment and Conditions of Service) Act, 1996
The Building and other Construction Workers‘ (Regulation of Employment and Conditions of Service) Act, 1996 (27 of 1996) - Section 59
Text of section 59
59. Winches:-The employer shall ensure at a construction site of a building
or other construction work that-
(a) (i) winches are not used if control levers operate with excessive
friction or play;
(ii) double gear winches are not used unless a positive
means of locking the gear shift is provided;
(iii) there is no load other than the fall and the hook
assembly on the winch while changing gears on a two
gear winch;
(iv) adequate protection is provided to winch operator
against abnormal weather;
(v) temporary seats or shelters for winch operators which
may pose hazard to the winch operator or any other
building workers are not allowed to be used;
(vi) control levers are secured in the neutral position and,
whenever possible, the power is shut-off whenever
winches are left unattended.
(b) in use of every steam winch-
(i) measures are taken to prevent escaping steam from
obscuring any part of the construction site or other work
place or from otherwise hindering or injuring any
building worker;
(ii) extension control levers which tend to fall of their own
weight are counter-balanced;
(iii) winch operators are not permitted to use the winch
control extension levers except for short handles on
wheel type controls and that such levers are of adequate
Rule 62 The Building and Other Construction Workers‘ 41
(Regulation of Employment and Conditions of Service)
Central Rules, 1998
strength, secure and fastened with metal connections at
the fulcrum and at the permanent control lever;
(c) in use of every electric winch, a building or other construction
worker is not permitted to transfer, alter or adjust electric
control circuits in case of any defect in such winch.
(d) electric winches are not used for building work where—
(i) the electro-magnetic brake is unable to hold the load; or
(ii) one or more control points, either hoisting or lowering,
are not operating properly.