Form OF LABORATORY REPORT THEREON, Environment (Protection) Rules, 1986.: FORM OF LABORATORY REPORT THEREON
Environment (Protection) Rules, 1986. - Form OF LABORATORY REPORT THEREON
Text of form OF LABORATORY REPORT THEREON
FORM OF LABORATORY REPORT THEREON
FORM OF LABORATORY REPORT THEREON
(1) Sample taken for analysis shall be sent by the Central Government or the
officer empowered to the environmental laboratory by registered post or through special
messenger along with Form II.
(2) Another copy of Form II together with specimen impression of seals of the
officer empowered to take samples along with the seals/marks, if any, of the person from
whom the sample is taken shall be sent separately in a sealed cover by registered post or
through a special messenger to the environmental laboratory.
(3) The findings shall be recorded in Form III in triplicate and signed by the
Government Analyst and sent to the officer from whom the sample is received for
analysis.
(4) On receipt of the report of the findings of the Government Analyst, the officer
shall send one copy of the report to the person from whom the sample was taken for
analysis, the second copy shall be retained by him for his record and the third copy shall
be kept by him to be produced in the Court before which proceedings, if any, are
instituted.
9. FUNCTIONS OF ENVIRONMENTAL LABORATORIES
The following shall be the functions of environmental laboratories:-
(i) to evolve standardized methods for sampling and analysis of various
types of environmental pollutants;
The Environment (Protection) Rules, 1986 398
(ii) to analyze samples sent by the Central Government or the officers
empowered under sub-section (1) of section 11.
(iii) to carry out such investigations as may be directed by the Central
Government to lay down standards for the quality of environment and discharge
of environmental pollutants, to monitor and to enforce the standards laid down;
(iv) to send periodical reports regarding its activities to the Central
Government;
(v) to carry out such other functions as may be entrusted to it by the
Central Government from time to time.
10. QUALIFICATIONS OF GOVERNMENT ANALYST
A person shall not be qualified for appointment or recognized as a Government Analyst
unless he is a:-
(a) graduate in science from a recognized university with five years
experience in laboratory engaged in environmental investigation, testing or
analysis; or
(b) post-graduate in science or a graduate in engineering or a graduate in
medicine or equivalent with two years experience in a laboratory engaged in
environmental investigations testing or analysis; or
(c) post-graduate in environmental science from a recognized university
with two years experience in a laboratory engaged in environmental
investigations, testing or analysis.
11. MANNER OF GIVING NOTICE
The manner of giving notice under clause (b) of section 19 shall be as follows,
namely:-
(l) The notice shall be in writing in Form IV.
(2) The person giving notice may send notice to-
(a) if the alleged offence has taken place in a Union territory
(A) the Central Board and
(B) Ministry of Environment and Forests (represented by the
Secretary to Government of India);
The Environment (Protection) Rules, 1986 399
(b) if the alleged offence has taken place in a State:
(A) the State Board; and
(B) the Government of the State (represented by the Secretary to
the State Government in-charge of environment); and
(C) the Ministry of Environment and Forests (represented by the
Secretary to the Government of India);
(3) The notice shall be sent by registered post acknowledgement due; and
(4) The period of sixty days mentioned in clause (b) of section 19 of the
Environment (Protection) Act, 1986 shall be reckoned from the date it is first received by
one of the authorities mentioned above.
1
[12. FURNISHING OF INFORMATION TO AUTHORITIES AND AGENCIES
IN CERTAIN CASES
Where the discharge of environmental pollutant in excess of the prescribed
standards occurs or is apprehended to occur due to any accident or other unforeseen act
or event, the person in charge of the place at which such discharge occurs or is
apprehended to occur shall forth with intimate the fact of such occurrence or
apprehension of such occurrence to all the following authorities or agencies, namely:-
(i) The officer-in-charge of emergency or disaster relief operation in a
district or other region of a state or Union territory specified by whatever
designation by the Government of the said State or Union territory, and in whose
jurisdiction the industry, process or operation is located.
(ii) Central Board or a State Board as the case may be and its regional
officer having local jurisdiction who have been delegated powers under section
20, 21, 23 of the Water (Prevention and Control of Pollution) Act, 1974 (6 of
l974) and section 24 of the Air (Prevention and Control of Pollution) Act, 1981
(14 of 1981).
(iii) The statutory authorities or agencies specified in column 3 in
relation to places mentioned in column 2 against thereof of the Schedule II.]
1
Rule 12 inserted vide Notification No. S.O. 32(E) dated 16.2.87 published in the Gazette No. 66 dated 16.2.87.
The Environment (Protection) Rules, 1986 400
1
[13. PROHIBITION AND RESTRICTION ON THE HANDLING OF
HAZARDOUS SUBSTANCES IN DIFFERENT AREAS
(1) The Central Government may take into consideration the following factors
while prohibiting or restricting the handling of hazardous substances in different areas-
(i) The hazardous nature of the substance (either in qualitative or
quantitative terms as far as may be) in terms of its damage causing potential to
the environment, human beings, other living creatures, plants and property;
(ii) the substances that may be or likely to be readily available as
substitutes for the substances proposed to be prohibited or restricted;
(iii) the indigenous availability of the substitute, or the state of
technology available in the country for developing a safe substitute;
(iv) the gestation period that may be necessary for gradual introduction
of a new substitute with a view to bringing about a total prohibition of the
hazardous substance in question; and
(v) any other factor as may be considered by the Central Government to
be relevant to the protection of environment.
(2) While prohibiting or restricting the handling of hazardous substances in an
area including their imports and exports the Central Government shall follow the
procedure hereinafter laid down-
(i) Whenever it appears to the Central Government that it is expedient to
impose prohibition or restriction on the handling of hazardous substances in an
area, it may, by notification in the Official Gazette and in such other manner as
the Central Government may deem necessary from time to time, give notice of its
intention to do so.
(ii) Every notification under clause (i) shall give a brief description of the
hazardous substances and the geographical region or the area to which such
notification pertains, and also specify the reasons for the imposition of
prohibition or restriction on the handling of such hazardous substances in that
region or area.
(iii) Any person interested in filing an objection against the imposition of
prohibition or restrictions on the handling of hazardous substances as notified
under clause (i) may do so in writing to the Central Government within sixty
days from the date of publication of the notification in the Official Gazette.
1
Rule 13 inserted vide Notification No G.S.R. 931(E) dated 27.10.89 published in the Gazette No. 564 dated 27.10.89.
The Environment (Protection) Rules, 1986 401
(iv) The Central Government shall within a period of ninety days
from the date of publication of the notification in the official Gazette consider
all the objections received against such notification and may impose
prohibition or restrictions on the handling of hazardous substances in a region
or an area.]
1
[14. SUBMISSION OF ENVIRONMENTAL
2
[STATEMENT]
Every person carrying on an industry, operation or process requiring consent
under Section 25 of the Water (Prevention and Control of Pollution) Act, 1974 (6 of
1974) or under section 21 of the Air (Prevention and Control of Pollution) Act, 1981
(14 of 1981) or both or authorization under the Hazardous Wastes (Management and
Handling) Rules, 1989 issued under the Environment (Protection) Act, 1986 (29 of
1986) shall submit an environmental
2
[statement] for the financial year ending the 31
st
March in Form V to the concerned State Pollution Control Board on or before the
3
[thirtieth day of September] every year, beginning 1993.]
1 Inserted by Rule 2 of the Environment (Protection) (second amendment) Rules, 1992 vide notification G.S.R. 329(E),
dated 13.3.1992.
2 Substituted by Rule 2(a) (i) of the Environment (Protection) Amendment Rules, 1993 vide notification G.S.R.
386(E), dated 22.4.1993
3 Substituted by Rule 2(a) (ii), ibid
The Environment (Protection) Rules, 1986 402
STANDARDS FOR EMISSION OR DISCHARGE OF
ENVIRONMENTAL POLLUTANTS
1
SCHEDULE – I (See rule 3)
Sr.
No.
Industry Parameter Standards
1 2 3 4
1. CAUSTIC SODA
INDUSTRY
Concentration not to exceed,
miligramme per lit. (except for pH
and flow)
Total concentration of
mercury in the final effluent
*
0.01
Mercury bearing waste-water
generation (flow)
10 kilolitres/ tonne of caustic soda
produced.
pH 5.5 to 9.0
*Final effluent is the combined effluent from (a) cell house, (b) brine
plant, (c) chlorine handling (d) hydrogen handling (e) hydrochloric
acid plant.
**2. MAN-MADE
FIBRES
(SYNTHETIC)
Concentration not to exceed
miligramme per litre (except for pH)
Suspended solids 100
Bio-chemical oxygen demand
2
[BOD 3 days at 27
o
C]
30
pH 5.5 to 9.0
3
[3. PETROLEUM
OIL REFINERY
A. EFFLUENT
1. pH 6.0-8.5
2. Oil & Grease 5.0
3. BOD 3 days, 27
o
C 15.0
4. COD 125.0
5. Suspended Solids 20.0
6. Phenols 0.35
7. Sulphides 0.5
8. CN 0.20
9. Ammonia as N 15.0
10. TKN 40.0
11. P 3.0
1 The Environment (Protection) Rules, 1986 are referred to as principal rules in all subsequent Notifications
beginning with S.O. 32(E), dated 16.2.1987 published in the Gazette no. 66, dated 16.2.1987. The Schedule to be
principal rules was renumbered as Schedule-I vide S.O. 32(E) supra.
**
Standards notified at Sl. No. 60 may also be referred.
2 Substituted by Rule 2 of the Environment (Protection) Amendment Rules, 1996 notified by G.S.R.176(E), dated
2.4.1996 may be read as BOD (3 days at 27oC) wherever BOD 5 days 20oC occurred.
3 Substituted by Rule 2 (i) of the Environment (Protection) Amendment Rules, 2008 notified by G.S.R.186(E),
dated 18.3.2008.
The Environment (Protection) Rules, 1986 403
Sr.
No.
Industry Parameter Standards
1 2 3 4
12. Cr (Hexavalent) 0.1
13. Cr (Total) 2.0
14. Pb 0.1
15. Hg 0.01
16. Zn 5.0
17. Ni 1.0
18. Cu 1.0
19. V 0.2
20. Benzene 0.1
21. Benzo (a) – Pyrene 0.2
Notes:-
(i) Concentration limits shall be complied with at the outlet, discharging effluent
(excluding discharge from sea water cooling systems) to receiving
environment (surface water Bodies, marine systems or public sewers). In
case of application of treated effluent directly for irrigation/horticulture
purposes (within or outside the premises of refinery), make-up water for
cooling systems, fire fighting, etc., the concentration limits shall also be
complied with at the outlet before taking the effluent for such application.
However, any use in the process such as use of sour water in desalter is
excluded for the purpose of compliance.
(ii) In case of circulating seawater cooling, the blow-down from cooling systems
shall be monitored for pH and oil & grease (also hexavalent & total
chromium, if chromate treatment is given to cooling water) and shall
conform to the concentration limits for these parameters. In case of reuse of
treated effluent as cooling water make-up, all the parameters (as applicable
for treated effluent) shall be monitored and conform to the prescribed
standards.
(iii) In case of once through cooling with seawater, the oil & grease content in the
effluent from cooling water shall not exceed 1.0 mg/l.
B. EMISSIONS
Limiting concentration in mg/Nm
3
, unless stated
(Furnace, Boiler
and Captive
Power Plant)
Fuel
Type
Existing
refineries
New Refinery/
Furnace/
Boiler
Sulphur Dioxide
(SO2)
Gas 50 50
Liquid 1700 850
Oxides of Nitrogen
(NOx)
Gas 350 250
Liquid 450 350
Particulate Matter
(PM)
Gas 10 5
Liquid 100 50
The Environment (Protection) Rules, 1986 404
Sr.
No.
Industry Parameter Standards
1 2 3 4
Carbon Monoxide
(CO)
Gas 150 100
Liquid 200 150
Nickel and Vanadium
(Ni+v)
Liquid 5 5
Hydrogen Sulphide
(H2S) in fuel gas
Liquid /
Gas
150 150
Sulphur content in
liquid fuel, weight%
Liquid /
Gas
1.0 0.5
Notes:-
(i) In case of mixed fuel (gas and liquid) use, the limit shall be computed based on
heat supplied by gas and liquid fuels.
(ii) All the furnaces/boilers with heat input of 10 million kilo calories/hour or more
shall have continuous systems for monitoring of SO2 and NO2. Manual
monitoring for all the emission parameters in such furnaces or boilers shall be
carried out once in two months.
(iii) All the emission parameters in furnaces/boilers having heat input less than 10
million kilo calories/hour will be monitored once in three months.
(iv) In case of continuous monitoring, one hourly average concentration values shall
be complied with 98% of the time in a month. Any concentration value obtained
through manual monitoring, if exceeds the limiting concentration value, shall be
considered as non-compliance.
(v) Data on Nickel and Vanadium content in the liquid fuel (in ppm) shall be
reported. Nickel and Vanadium in the liquid fuel shall be monitored at least once
in six months, if liquid fuel source & quality are not changed. In case of
changes, measurement is necessary after every change.
(FCC
Regenerators)
Limiting concentration in mg/Nm
3
,
unless stated
Existing refineries New Refinery
/FCC
Commissioned
Hydro
processed
FCC feed
Other than
Hydro
processed
FCC feed
Sulphur Dioxide
(SO2)
500 1700 500 (for hydro-
processed feed)
850 for other
feed)
Oxides of Nitrogen
(NOx)
400 450 350
Particulate Matter
(PM)
100 100 50
Carbon Monoxide
(CO)
400 400 300
Nickel and
Vanadium (Ni+V)
2 5 2
Opacity, % 30 30 30
The Environment (Protection) Rules, 1986 405
Sr.
No.
Industry Parameter Standards
1 2 3 4
Notes:-
(i) In case part feed is hydro-processed, the emission values shall be calculated
proportional to the feed rates of untreated and treated feeds.
(ii) FCC regenerators shall have continuous systems for monitoring of SO2 and
NOx. One hourly average concentration values shall be complied with 98% of
the time in a month, in case of continuous monitoring. Manual monitoring
for all the emission parameters shall be carried out once in two months.
(iii) Any concentration value obtained through manual monitoring, if exceeds the
limiting concentration value, shall be considered as non-compliance.
(iv) Data on Sulphur (weight in %), Nickel (PPM) and Vanadium (PPM) content
in the feed to FCC shall be separated regularly.
(v) Limit of Carbon Monoxide emissions shall be complied with except during
annual shut down of CO boiler for statutory maintenance.
Plant
Capacity
(Tonnes/day)
Existing
SRU
New SRU or
Refinery
Commissioned
{Sulphur,
Recovery
Units (SRU)}
Sulphur recovery, % Above 20 98.7 99.5
H2S, mg/Nm
3
15 10
Sulphur recovery, % 5-20 96 98
Sulphur recovery, % 1-5 94 96
Oxides of Nitrogen
(NOx), mg/Nm
3
All capacity 350 250
Carbon Monoxide
(CO), mg/Nm
3
All capacity 150 100
Notes:-
(i) Sulphur recovery units having capacity above 20 tonnes per day shall have
continuous systems for monitoring of SO2. Manual monitoring for all the
emission parameters shall be carried out once in a month.
(ii) Data on Sulphur Dioxide emissions (mg/Nm
3
) shall be reported regularly.
(iii) Sulphur recovery efficiency shall be calculated on monthly basis, using
quantity of sulphur in the feed to SRU and quantity of sulphur recovered.
The Environment (Protection) Rules, 1986 406
C- FUGITIVE EMISSION
Storage of Volatile Liquids : General Petroleum Products
(1) Storage tanks with capacity between 4 to 75m
3
and total vapour Pressure
(TVP) of more than 10 kpa should have Fixed Roof Tank (FRT) with
pressure valve vent.
(2) Storage tank with the capacity between 75 to 500 m
3
and total vapour
Pressure (TVP) of 10 to 76 kpa should have Internal Floating Root Tank
(IFRT) of External Floating Root Tank (EFRT) or Fixed Roof Tank with
vapour control or vapour balancing system.
(3) Storage tanks with the capacity of more than 500 m
3
and total vapour
Pressure (TVP) of 10 to 76 kpa should have Internal Floating Roof Tank or
External Floating Roof Tank or Fixed Roof Tank with vapour control system.
(4) The tanks with the capacity of more than 75 m
3
and total vapour Pressure
(TVP) of more than 76 kpa should have Fixed Root Tank with vapour control
system.
(5) Requirement for seals in Floating Roof Tanks:
(i) (a) IFRT and EFRT shall be provided with double seals with
minimum vapour recovery of 96%.
(b) Primary seal shall be liquid or shoe mounted for EFRT and
vapour mounted for IFRT. Maximum seal gap width will be
4 cm and maximum gap area will be 200 cm
2
/m of tank
diameter.
(c) Secondary seal shall be rim mounted. Maximum seal gap
width will be 1.3 cm and maximum gap area will be 20
cm
2
/m of tank diameter.
(d) Material of seal and construction shall ensure high
performance and durability.
(ii) Fixed Roof Tanks shall have vapour control efficiency of 95%
and vapour balancing efficiency of 90%
(iii) Inspection and maintenance of storage tanks shall be carried out
under strict control. For the inspection, API RP 575 may be
adopted, In-service inspection with regard seal gap should be
carried out once in every six months and repair to be
implemented in short time. In future, possibility of on-stream
repair of both seals shall be examined.
The Environment (Protection) Rules, 1986 407
Storage of Volatile Liquids : Benzene Storage
(1) FRT with vapour to incineration with 99.9% of removal efficiency for
volatile organic compounds (VOC) shall be provided.
(2) IFRT/EFRT with double seals, emission-reducing roof fitting and fitted with
fixed roof with vapour removal efficiency of at least 99% shall be provided.
Solvents for Lube-Base Oil production (Furfural, NMP, MEK, Toluene and
MIBK)
IFRT with double seals and inert gas blanketing with vapour removal efficiency of at
least 97% shall be provided.
Emission control for Road tank truck/Rail tank wagon loading
Loading of Volatile
Products
Gasoline and Naphtha:
(i) VOC reduction, %.
(ii) Emission, gm/m
3
(i) 99.5
(ii) 5
Benzene:
(i) VOC reduction, %
(ii) Emission, mg/m
3
(i) 99.99
(ii) 20
Toluene/Xylene:
(i) VOC reduction, %
(ii) Emission, mg/m
3
(i) 99.98
(ii) 150
Note:
(i) It shall be applicable for Gasoline, Naphtha,
Benzene, Toluene and Xylene loading.
(ii) Road tank Truck shall have Bottom loading and
Roll tank wagon shall have Top submerged
loading.
(iii) Annual leak testing for vapour collection shall be
done.
Standards for Equipment Leaks
(1) Approach: Approach for controlling fugitive emissions from
equipment leaks shall have proper selection, installation and
maintenance of non-leaking or leak-tight equipment. Following
initial testing after commissioning, the monitoring for leak detection
is to be carried out as a permanent on-going Leak Detection and
Repair (LDAR) programme. Finally detected leaks are to be repaired
within allowable time frame.
The Environment (Protection) Rules, 1986 408
(2) Components to be Covered: Components that shall be covered under
LDAR programme include (i) Block valves; (ii) Control valves;
(iii) Pump seals; (iv) Compressor seals; (v) Pressure relief valves;
(vi) Flanges – Heat Exchangers; (vii) Flanges – Piping; (viii)
Connectors – Piping; (ix) Open ended lines; and (x) Sampling
connections, Equipment and line sizes more than 1.875 cm or ¾ inch
are to be covered.
(3) Applicability: LDAR programme would be applicable to components
(given at 2 above) for following products/compounds: (i)
hydrocarbon gases; (ii) Light liquid with vapour pressure @ 20
o
C
> 1.0 kPa; and (iii) Heavy liquid with vapour pressure @ 20
o
C
between 0.3 to 1.0 kPa.
(4) While LDAR will not be applicable for heavy liquids with vapour
pressure < 0.3 kPa, it will be desirable to check for liquid dripping as
indication of leak.
(5) Definition of leak: A leak is defined as the detection of VOC
concentration more than the values (in ppm) specified below at the
emission source using a hydrocarbon analyzer according to
measurement protocol (US EPA – 453/R-95-017, 1995 Protocol for
equipment leak emission estimates may be referred to:
Component General
Hydrocarbon (ppm)
Benzene (ppm)
Till 31
st
Dec.
2008
w.e.f.
January
01, 2009
Till 31
st
Dec.,
2008
w.e.f
January
01, 2009
Pump/Compressor 10000 5000 3000 2000
Valves/Flanges 10000 3000 2000 1000
Other components 10000 3000 2000 1000
(6) In addition, any component observe to be leaking by sight, sound or
smell, regardless of concentration (liquid dripping, visible vapor
leak) or presence of bubbles using soap solution should be
considered as leak.
(7) Monitoring Requirements and Repair Schedule: Following frequency
of monitoring of leaks and schedule for repair of leaks shall be
followed:
The Environment (Protection) Rules, 1986 409
Component Frequency of
monitoring
Repair schedule
Quarterly (semiannual
after two consecutive
periods with < 2%
leaks and annual after
5 periods with < 2%
leaks)
Repair will be started
within 5 working days
and shall be completed
within 15 working days
after detection of leak for
general hydrocarbons. In
case of benzene, the leak
shall be attended
immediately for repair.
Pump seals Quarterly
Compressor seals Quarterly
Pressure relief
devices
Quarterly
Pressure relief
devices (after
venting)
Within 24 hours
Heat Exchangers Quarterly
Process drains Annually
Components that
are difficult to
monitor
Annually
Pump seals with
visible liquid
dripping
Immediately Immediately
Any component
with visible leaks
Immediately Immediately
Any component
after repair/
replacement
Within five days -
(8) The percentage leaking components should not be more than 2% for any
group of components monitored excluding pumps/compressors. In case of
pumps/compressors it should be less than 10% of the total number of
pumps/compressors or three pumps and compressors, whichever is greater.
(9) Emission inventory: Refinery shall prepare on inventory of equipment
components in the plant. After the instrumental measurement of leaks,
emission from the components will be calculated using stratified emission
factor (USEPA) or any other superior factors. The total fugitive emission
will be established.
The Environment (Protection) Rules, 1986 410
(10) Monitoring following types of monitoring methods may be judiciously
employed for detection of leaks: (i) instrumental method of measurement of
leaks; (ii) Audio, visual and olfactory (AVO) leak detection; and (iii) Soap
bubble method.
(11) Data on time of measurement and concentration value for leak detection;
time of repair of leak; and time of measurement & concentration value after
repair of leak should be documented for all the components.
(12) Pressure relief and blow down systems should discharge to a vapour
collection and recovery system or to flare.
(13) Open-ended lines should be closed by a blind flange or plugged.
(14) Totally closed-loop should be used in all routine samples.
(15) Low emission packing should be used for valves.
(16) High integrity sealing materials should be used for flanges.
D. Emission Standards for VOC from Wastewater Collection and Treatment
(1) All contaminated and odorous wastewater streams shall be handled in closed
systems from the source to the primary treatment stages (oil-water separator
and equalization tanks).
(2) The collection system shall be covered with water seals (traps) on sewers and
drains and gas tight covers on junction boxes.
(3) Oil-water separators and equalization tanks shall be provided with
floating/fixed covers. The off-gas generated shall be treated to remove at least
90% of VOC and eliminate odour. The system design shall ensure safety
(prevention of formation of explosive mixture, possible detonation and
reduce the impact) by dilution with air/inert gas, installing LEL detector
including control devices, seal drums, detonation arrestors etc. The system
shall be designed and operated for safe maintenance of the collection and
primary treatment systems.
(4) Wastewater from aromatics plants (benzene and xylene plants) shall be
treated to remove benzene & total aromatics to a level of 10, 20 ppm
respectively before discharge to effluent treatment system without dilution].
The Environment (Protection) Rules, 1986 411
Sr.
No.
Industry Parameter Standards
1 2 3 4
4. SUGAR
INDUSTRY
Concentration not exceed,
milligramme per litre
Bio-chemical oxygen demand,
1
[3 days at 27
o
C]
100 for disposal on land
30 for disposal in surface water
Suspended solids 100 for disposal on land.
30 for disposal in surface waters.
5. THERMAL
POWER
PLANTS
Maximum limiting concentration,
milligrammes per litre (except for pH
and temperature)
Condenser Cooling
waters (once through
cooling system)
pH
6.5 – 8.5
Temperature Not more than 5
o
C higher than the
intake water temperature
Free available chlorine 0.5
Boiler blowdowns Suspended solids 100
Oil and Grease 20
Copper (total) 1.0
Iron (total) 1.0
Cooling tower blowdown Free available chlorine 0.5
Zinc 1.0
Chromium (total) 0.2
Phosphtate 5.0
Other corrosion
inhibiting material
Limit to be established on case by case
basis by Central Board in case of
Union territories and State Board in
case of States.
Ash pond effluent pH 6.5 – 8.5
Suspended solids 100
Oil and Grease 20
1
Substituted by Rule 2 of the Environment (Protection) Amendment Rules, 1996 notified by G.S.R.176(E), dated
2.4.1996 may be read as BOD (3 days at 27oC) wherever BOD 5 days 20oC occurred.
The Environment (Protection) Rules, 1986 412
Sr.
No.
Industry Parameter Standards
1 2 3 4
6. COTTON TEXTILE
INDUSTRIES
(COMPOSITE AND
PROCESSING)
Concentration not to exceed,
milligramme per litre (except for pH
and bioassay)
Common
pH 5.5 to 9
Suspended solids 100
Bio-Chemical Oxygen
Demand
1
[3days at
27
o
C]
150
Oil and grease 10
Bio-assay test 90% survival of fish of after 96 hours
Special:
Total chromium as
(Cr)
2
Sulphide (as S) 2
Phenolic compounds
(as C4H2OH)
5
The special parameters are to be stipulated by the Central Board in case of Union territories
and State Boards in case of States depending upon the dye used in the industry. Where the
industry uses chrome dyes, sulphur dyes and/or phenolic compounds in the dyeing/printing
process, the limits on chromium of 2 mg/litre, sulphides of 2 mg/litre and phenolic
compounds of 5 mg/litre respectively shall be imposed.
Where the quality requirement of the recipient system so warrants, the limit of BOD should
be lowered upto 30 according to the requirement by the State Boards for the States and the
Central Board for the union territories.
A limit on sodium absorption ratio of 26 should be imposed by the State Boards for the
States and the Central Board for the Union territories if the disposal of effluent is to be made
on land.
1
Substituted by Rule 2 of the Environment (Protection) Amendment Rules, 1996 notified by G.S.R.176(E), dated
2.4.1996 may be read as BOD (3 days at 27oC) wherever BOD 5 days 20oC occurred.
The Environment (Protection) Rules, 1986 413
Sr.
No.
Industry Parameter Standards
1 2 3 4
7. COMPOSITE
WOOLLEN MILLS
Concentration not be exceed,
milligramme per litre (except for pH
and bioassay)
Common : Suspended Solids 100
pH 5.5 to 9.0
Bio-chemical oxygen
demand
1
[3days at
27
o
C]
100
Oil and grease 10
Bio-assay 90% survival of fish after 96 hrs.
Special : Total chromium (as
Cr)
2
Sulphide (as S) 2
Phenolic Compounds
(as C6H5OH)
5
The special parameters are to be stipulated by the Central Board in case of Union territories
and State Boards in case of State depending upon the dye used in the industry. Where the
industry uses chrome dyes, sulphur dyes and or/phenolic compounds in the dyeing/printing
process, the limits on chromium of 2 mg/litre, sulphides of 2 mg./litre and phenolic
compounds of 5 mg/litre respectively shall be imposed.
Where the quality requirement of the recipient system so warrants, the limit of BOD should
be lowered upto 30 according to the requirement by the State Boards for the States and the
Central Board for the Union territories.
A limit on sodium absorption ratio of 26 should be imposed by the State Boards for the
States and the Central Board for the Union Territories if the disposal of the effluent is to be
made on land.
#1
8 DYE AND DYE
INTERMEDIATE
INDUSTRY
Concentration not to exceed
milligrammes per litre (except for pH,
temperature and bio-assay)
Suspended Solids 100
pH 6 to 8.5
Temperature Shall not exceed 5
o
C above the
ambient temperature of the receiving
body.
#
Standards notified at Sl. No. 45 may also be referred.
1
Sl. No. 8,9 and 10 and entries relating thereto inserted vide S.O. 393(E) dt. 16.4.87 published in the Gazette No.
185 dt. 16.4.87.
The Environment (Protection) Rules, 1986 414
Sr.
No.
Industry Parameter Standards
1 2 3 4
Mercury (as Hg) 0.01
Hexavalent (as Cr) 0.1
Chromium (Total
Chromium (as Cr)
2.0
Copper (as Cu) 3.0
Zinc (as Zn) 5.0
Nickel (as Ni) 3.0
Cadmium (as Cd) 2.0
Chloride (as Cl) 1000
Sulphate (as SO4) 1000
Phenolic Compounds
(as C6H5OH)
1.0
Oil and Grease 10
Bio-assay Test (with
1:8 dilution of
effluents)
90% survival of Test animals after 96
hours.
The standards for chlorides and sulphates are applicable or discharge into inland and
surface water courses. However, when discharged on land for irrigation, the limit for
chloride shall not be more than 600 milligrammes per litre and the sodium absorption ratio
shall not exceed 26.
9.
ELECTROPLATING
INDUSTRIES
Concentration not to exceed
milligrammes per litre (except for pH
and temperature)
pH 0.6 to 9.0
Temperature Shall not exceed 5
o
C above the
ambient temperature of the receiving
body.
Oil and Grease 10
Suspended Solids 100
Cynides (as CN) 0.2
Ammonical 50
Nitrogen (as N)
Total Residual
Chlorides (as Cl)
1.0
The Environment (Protection) Rules, 1986 415
Sr.
No.
Industry Parameter Standards
1 2 3 4
Cadmium (as Cd) 2.0
Nickei (as Ni) 3.0
Zinc (as Zn) 5.0
Hexavalent 0.1
Chromium as (Cr)
Total Chromium (as
Cr)
2.0
Copper (as Cu) 3.0
Lead (as Pb) 0.1
Iron (as Fe) 3.0
Total Metal 10.0
1
[10. CEMENT PLANTS
not to exceed mg/Nm
3
A. TOTAL DUST
Plant Capacity
(i)200 tonnes/day
(all sections)
400
(ii) Greater than 200
tonnes/day
(all sections)
250
B. EMISSIONS
(i) For Cement Plants, including Grinding Units, located in critically polluted* or
urban areas with a population of one lakh and above (including 5 Km distance
outside urban boundary):
Particulate Matter 100mg/Nm
3
(ii) New Cement Kilns, including Grinding Units to be installed after the date of
notification:
Particulate Matter 50 mg/Nm
3
* As per the guidelines of the Central Pollution Control Board]
1
Substituted by Rule 2(I) of the Environment (Protection) First Amendment Rules, 2006 notified by G.S.R.46(E),
dated 3.2.2006.
The Environment (Protection) Rules, 1986 416
Sr.
No.
Industry Parameter Standards
1 2 3 4
#1
11. STONE CRUSHING
UNIT
Suspended Particulate
Matter
The suspended particulate matter
measured between 3 metres and 10
metres from any process equipment of
a stone crushing unit shall not exceed
600 microgrammes per cubic metre.
2
12.
COKE OVENS Concentration in the effluents when
discharged into inland surface waters
not be exceed milligramme per litre
(except for pH)
pH 5.5 – 9.0
Biochemical Oxygen
Demand (27
o
C for 3
days)
30
Suspended Solids 100
Phenolic Compounds
(as C6H5OH)
5
Cynides (as CN) 0.2
Oil & Grease 10
Ammonical Nitrogen
(as N)
50
13.
SYNTHETIC
RUBBER
Concentration in the effluents when
discharged into inland surface waters
not be exceed milligramme per litre
(except for colour and pH)
Colour Absent
pH 5.5 – 9.0
Biochemical Oxygen
Demand
1
[BOD (3
days at 27
o
C]
50
Chemical Oxygen
Demand
250
Oil and grease 10.0
1
S.No.11 and entries relating thereto inserted vide SO 443(E)dt.18.4.87 published in the Gazette no. 206 dt. 18.4.87.
#
Standards notified at Sl. No. 37 may also be referred.
2
S.Nos. 12 to 24 and entries relating thereto inserted vide S.O. 64(E) published in the Gazette No. 42 dt. 18.1.88.
The Environment (Protection) Rules, 1986 417
Sr.
No.
Industry Parameter Standards
1 2 3 4
14. SMALL PULP AND
PAPER INDUSTRY
Concentration not be exceed mg/l
(except for pH and sodium absorption
ratio)
*Discharge into inland
surface water
pH 5.5 – 9.0
Suspended Solids 100
BOD 30
Disposal on land pH 5.5 – 9.0
Suspended Solids 100
BOD 100
Sodium Absorption
Ratio
1
[Absorbable Organic
Halogens
(AOX) in effluent
discharge
26
3.00 kg/ton of paper produced with
effect from the date of publication of
this notification.
2.00 kg/ton of paper produced with
effect from the 1
st
day of March,
2006.
Explanation.- These standards shall apply to all small scale Pulp and Paper Mills having
capacity below 24,000 MT per annum]
2
15. FERMENTATION
INDUSTRY
(DISTILLERIES,
MALTRIES AND
BREWERIES)
Concentration in the effluents not to
exceed milligramme per litre (except
for pH and colour & odour)
pH 5.5 – 9.0
Colour & Odour All efforts should be made to remove
colour and unpleasant odour as far as
practicable.
Suspended Solids 100
3
[BOD (3 days at
27
o
C)]
4
[-disposal into inland
surface waters or river/
streams]
30
- disposal on land or
for irrigation]
**[(2)….(7)]
100
1
Inserted by Rule 2 (i) of the Environment (Protection) Third Amendments Rules, 2005 notified vide Notification
G.S.R.546(E), dated 30.8.2005.
2
Entries relating to S.No. 15 corrected in terms of SO 12(E), dt. 8.1.90 published in the Gazette no. 10 dt. 8.1.90.
3
Substituted by Rule 2 of the Environment (Protection) Amendment Rules, 1996 notified by G.S.R.176(E), dated
2.4.1996 may be read as BOD (3 days at 27oC) wherever BOD 5 days 20oC occurred.
4
Substituted vide Rule 3(a) of the Environment (Protection) (Amendments) Rules, 1996 notified vide
G.S.R.186(E), dated 2.4.1996
The Environment (Protection) Rules, 1986 418
Sr.
No.
Industry Parameter Standards
1 2 3 4
Note :
1
[(1)] *Wastewater generation shall not exceed 250 metre cube per tonne of
paper produced.
2
[(2)…….(7)]
16. LEATHER
TANNERIES
Concentration in the effluent not to
exceed milligramme per litre (except
for pH and per cent sodium)
Inland
Surface
Waters
Public
Sewers
Land for
Irrigation
Marine Coastal
areas
(a) (b) (c) (d)
Suspended Solids 100 00 200 100
3
[BOD 3 days at 27
o
C] 30 350 100 100
pH
6.0 – 9.0 6.0 – 9.0 6.0 – 9.0 6.0 – 9.0
Chlorides (as Cl) 1000 1000 200 -
Hexavalent Chromium
(Cr+6)
0.1 0.2 0.1 1.0
Total 2.0 2.0 2.0 2.0
Chromium (as Cr)
Sulphides (as S) 2.0 5.0 - 5.0
Sodium percent - 60 60 -
Boron (as B) 2.0 2.0 2.0 -
Oil & Grease 10 20 10 20
1
Renumbered as (1) by Notification No.S.O.12(E), dated 8.1.1990
2
Notes 2 to 7 inserted by Notification S.O.12(E), dated 8.1.1990 and omitted by G.S.R.176(E), dated 2.4.1996
w.e.f. 3.4.1996
3
Substituted by Rule 2 of the Environment (Protection) Amendment Rules, 1996 notified by G.S.R.176(E), dated
2.4.1996 may be read as BOD (3 days at 27oC) wherever BOD 5 days 20oC occurred.
The Environment (Protection) Rules, 1986 419
Sr.
No.
Industry Parameter Standards
1 2 3 4
17. FERTILIZER
INDUSTRY
Concentration in the effluent not to
exceed milligramme per litre (except
for pH )
EFFLUENTS Plants
Commissioned
January 1, 1982
onwards
Plants
Commissioned
Prior to
January 1,
1982
- Straight
Nitrogeneous
Fertilizers, Excluding
the Calcium
Ammonium Nitrate
and Ammonium
Nitrate Fertilizers
(a) (b)
pH 6.5 – 8.0 6.5 – 8.0
Ammonical Nitrogen 50 75
Total Kjeldahl
Nitrogen
100 150
Free Ammonical
Nitrogen
4 4
Nitrate Nitrogen 10 10
Cynide as CN 0.2 0.2
Vanadium as V 0.2 0.2
Arsenic as As 0.2 0.2
Suspended solids 100 100
Oil and Grease 10 10
*
Hexavalent
Chromium as Cr.
0.1 0.1
*Total Chromium as
Cr.
2.0 2.0
Straight Nitrogenous
Fertilizers, including
Calcium Ammonium
Nitrate and
Ammonium Nitrate
Fertilizers
Plants
Commissioned
January 1, 1982
onwards
Plants
Commissioned
prior to
January 1,
1982
*
To be complied with at the outlet of Chromate removal unit.
The Environment (Protection) Rules, 1986 420
Sr.
No.
Industry Parameter Standards
1 2 3 4
(a) (b)
pH 6.5 – 8.0 6.5 – 8.0
Ammonical Nitrogen 50 75
Total Kjeidahl
Nitrogen
150
Free Ammonical
Nitrogen
4 4
Nitrate Nitrogen 20 20
Cynide as CN 0.2 0.2
Vanadium as V 0.2 0.2
Arsenic as As 0.2 0.2
Suspended solids 100 100
Oil and Grease 10 10
Hexavalent
Chromium as Cr
0.1 0.1
*Total Chromium as
Cr
2.0 2.0
Complex Fertilizers
excluding Calcium
Ammonium Nitrate,
Ammonium Nitrate &
Ammonium
Nitrophosphate
Feritilizers
Plants
Commissioned
January 1, 1982
onwards
Plants
Commissioned
prior to
January 1,
1982
(a) (b)
pH 6.5 – 8.0 6.5 – 8.0
Ammonical Nitrogen 50 75
Free Ammonical
Nitrogen
4 4
Total Kjeldahl
Nitrogen
100 100
Nitrate Nitrogen 10 10
To be complied with at the outlet of Chromate removal unit.
The Environment (Protection) Rules, 1986 421
Sr.
No.
Industry Parameter Standards
1 2 3 4
Cynide as CN 0.2 0.2
Vanadium as V 0.2 0.2
Arsenic as As 0.2 0.2
Phsophate as P 5 5
Suspended solids 100 100
Oil and Grease 10 10
*
Fluoride as F 10 10
**
Hexavalent
Chromium as Cr
0.1 0.1
**Total Chromium as
Cr
2.0 2.0
Complex Fertilizers
including Calcium
Ammonium Nitrate,
Ammonium Nitrate &
Ammonium
Nitrophosphate
Fertilizers
Plants
Commissioned
January 1, 1982
onwards
Plants
Commissioned
prior to
January 1,
1982
(a) (b)
pH 6.5 – 8.0 6.5 – 8.0
Ammonical Nitrogen 50 75
Free Ammonical
Nitrogen
100 100
Nitrate Nitrogen 20 20
Cynide as CN 0.2 0.2
Vanadium as V 0.2 0.2
Arsenic as As 0.2 0.2
*
To be complied with at the outlet of fluoride removal unit. If the recipient system so
demand, fluoride as F shall be limited to 1.5 mg/l.
**
To be complied with at the outlet of Chromate removal unit.
The Environment (Protection) Rules, 1986 422
Sr.
No.
Industry Parameter Standards
1 2 3 4
Phosphate as P 5 5
Oil and Grease 10 10
Suspended Solids 10 100
*
Fluoride as F 10 10
**
Hexavalent
Chromium as Cr.
0.1 0.1
**Total Chromium as
Cr
2.0 2.0
Straight Phosphate
Fertilizers
pH 7.0 –9.0
Phosphate as P 5
Oil and Grease 10
Suspended Solids 100
*Fluoride as F 10
**Hexavalent
Chromium as Cr
0.1
**Total Chromium as
Cr
2.0
Emissions
Phosphatic Fertilizers
(Fluorides and
Particulate matter
emission)
Phosphorice acid
manufacturing unit
Granulation mixing
and grinding of rock
phosphate
25 milligramme per normal cubic
metre as total Fluoride 150
milligramme per normal cubic metre
of particulate matter.
Urea (Particulate matter
emission)
Pricing tower
Commissioned prior to
01.01.1982
Commissioned after
1.1.1982
150 milligramme per normal cubic
metre of 2 kilogramme per tone of
product.
50 milligramme per normal cubic
metre or 0.5 kilogramme per tonne of
product
*
To be complied with at the outlet of fluoride removal unit. If the recipient system so demand, fluoride as F shall
be limited to 1.5 mg/l.
**
To be complied with at the outlet of Chromate removal unit.
The Environment (Protection) Rules, 1986 423
Sr.
No.
Industry Parameter Standards
1 2 3 4
1
[18. OMITTED
19. CALCIUM CARBIDE Particulate Matter
Emission
- Kiln 250 milligramme per normal cubic
metre.
- Arc Furnace 150 milligramme per normal cubic
metre.
20. CARBON BLACK Particulate matter
Emission
150 milligramme per normal cubic
metre.
21. COPPER, LEAD AND
ZINC SMELTING
Particulate Matter
Emission in
Concentrator
150 milligramme per normal cubic
metre.
Emission of Oxides of
Sulphur in Smelter &
convertor
Off-gases must be utilized for
sulphuric acid manufacture. The
limits of sulphur dioxide emission
from stock shall not exceed 4
kilogramme per tonne of concentrated
(one hundred per cent acide
produced).
22. NITRIC ACID
(EMISSION OXIDES
OF NITROGEN)
Emission of Oxides of
Nitrogen
3 kilogramme of oxides of nitrogen
per tonne of weak acid (before
concentration) produced.
2
[23. SULPHURIC ACID
PLANT
Emission standards
Limiting
concentration in
mg/Nm
3
,
unless stated
Plant capacity for
100% concentration
of Sulphuric Acid
(tonne/day)
1
Sr. No.18 relating to “Aluminum” and entries relating thereto omitted by Rule 2(II) of the Environment
(Protection) First Amendment Rules, 2006 notified by G.S.R. 46(E), dated 3.2.2006.
2
Substituted by Rule 2(I) of the Environment (Protection) Third Amendment Rules, 2008 notified by G.S.R.
344(E), dated 7.5.2008.
The Environment (Protection) Rules, 1986 424
Sr.
No.
Industry Parameter Standards
1 2 3 4
Existing Unit New Unit
Sulphur dioxide (SO2) upto 300 1370 1250
Above 300 1250 950
Acid Mist/Sulphur Up to 300 90 70
Trioxide Above 300 70 50
Note:
(i) Scrubbing units shall have on-line pH meters with auto recording facility.
(ii) The height of the stack emitting sulphur-dioxide or acid mist shall be of minimum of
30 metre or as per the formula H=14(Q)
(0.3)
(whichever is more). Where ―H‖ is the
height of stack in metre; and ―Q‘ is the maximum quantity of SO2 expected to be
emitted through the stack at 110 per cent rated capacity of the plants and calculated as
per the norms of gaseous emission.
(iii) Plants having more than one stream or unit of sulphuric acid at one location, the
combined capacity of all the streams and units shall be taken into consideration for
determining the stack height and applicability of emission standards.
(iv) Plants having separate stack for gaseous emission for the scrubbing unit, the height of
this stack shall be equal to main stack].
24. IRON & STEEL
(INTEGRATED)
Particulate Matter
Emission
- Sintering Plant 150 milligramme per normal cubic
metre
- Steel making
-- during normal
operations
150 milligramme per normal cubic
metre.
--during oxygen
lancing
400 milligramme per normal cubic
metre.
- Rolling Mill 150 milligramme per normal cubic
metre.
- Carbon monoxide
from coke oven
3 kilogramme per tonne of coke
produced.
The Environment (Protection) Rules, 1986 425
Sr.
No.
Industry Parameter Standards
1 2 3 4
1
25. THERMAL POWER
PLANTS
Particulate Matter
Emissions :
- generation cpacity
210 MW or more
150 millogramme per normal cubic
metre.
- generation capacity
less than 210 MW
350 milligramme per normal cubic
metre.
26. NATURAL RUBBER
INDUSTRY
Concentrations in the effluents not to
exceed milligramme per litre (except
for pH) 44
o
C
- Discharge into inland
surface water
Colour & odour Absent
pH 6.0 – 9.0
BOD 50
COD 250
Oil and Grease 10
Sulphides 2
Total Kjeldahl
Nitrogen
100
Dissolved phosphate
(as P)
5
Suspended Solids 100
Dissolved solids
(inorganic)
2100
Ammonical Nitrogen
as N
50
Free ammonia (as
NH3)
5
-Disposal on land for
irrigation
Colour and Odour Absent
pH 6.0 – 8.0
BOD 100
COD 250
Oil & Grease 10
Suspended Solids 200
Dissolved solids 2100
1
S. No. 25 and 26 and entries relating thereto inserted vide S.O. 8(E) dt. 3.1.89 published in the Gazette No. 7
dated. 3.1.89.
Corrections in rule 2 against S.No. 26 made vide corrigendum No. S.O. 190 (E) dt. 15.3.89 published in the
Gazette no. 126 dt. 15.3.89.
Depending upon the requirement of local situation, such as protected area, the State Pollution Control Board
and other implementation agencies under the Environment (Protection) Act, 1986 may prescribed a limit of 150
milligramme per normal cubic meter, irrespective of generation capacity of the plant.
The Environment (Protection) Rules, 1986 426
Sr.
No.
Industry Parameter Standards
1 2 3 4
1
[
2
27. ASBESTOS
MANUFACTURING
UNITS (INCLUDING
ALL PROCESSES
INVOLVING THE
USE OF ASBESTOS)
- Pure Asbestos
material
0.5 fibre */cc for one year from the
date of notification
0.2 fibre */cc after one year from the
date of notification]
- Total Dust 2 mg/m
3
(normal)
28.
CALOR ALKALI
(CAUSTIC SODA)
EMISSIONS Concentration in mg/m
3
(normal)
(a) Mercury Cell Mercury (from
hydrogen gas holder
stack)
0.2
(b) All processes Chlorine (from hypo
tower)
15.0
(c) All processes Hydro chloric acid
vapours and mist
(from hydro chloric
acid plant)
35.0
29. LARGE PULP AND
PAPER
EMISSIONS Concentration in mg/m
3
(normal)
Particulate matter 250
**
H2S 10
30. INTEGRATED IRON
AND STEEL
PLANTS:
I. EMISSIONS
(a) Coke Oven Particulate mater 50
(b) Refractory
material plant
Particulate matter 150
II. EFFLUENTS Concentration in mg/l except for pH.
(a) Coke oven
By product plant. pH 6.0 – 8.0
Suspended Solids 100
1
Standards mentioned at Sl. No.27 amended by Rule 2(III) of the Environment (Protection) First Amendment
Rules, 2006 notified vide Notification G.S.R.46(E), dated 3.2.2006.
2 S.No. 27 to 31 and entries relating thereto inserted vide GSR 913(E) dt. 24.10.89 published in the Gazette No.
554 dt. 24.10.89.
**
This standard of 250 mg/m3 (normal) shall apply only for a period of 3 years with effect from the date on which
the Environment (protection) Second Amendment Rules, 1989 came into force. After three years the standard to
be applicable is 15 mg/m3 (normal).
The Environment (Protection) Rules, 1986 427
Sr.
No.
Industry Parameter Standards
1 2 3 4
Phenol 1.0
Cynide 0.2
BOD
1
[(3 days at
27
o
C)]
30
COD 250
Ammonical Nitrogen 50
Oil and Grease 10
(b)Other plants such as
sintering plant, blast
furnace, steel melting
and rolling mill:
pH
6.0 – 9.0
Suspended Solids 100
Oil and Grease 10
31. RE-HEATING
(REVERBERATORY)
FURNACES:
EMISSIONS Concentration in mg/m
3
(normal)
Capacity : All sizes
Sensitive area Particulate matter 150
Other area Particulate matter 450
2
[32. FOUNDRIES EMISSIONS
(a) Cupola Capacity
(Melting Rate) :
Less than 3 mt./hr. Particulate Matter 450
3 mt/hr. and above Particulate Matter 150
Note : It is essential that stack is constructed over the cupola beyond the charging door
and emissions are directed through the stack which should be at least six times the
diameter of cupola.
(b) Arc Furnaces :
Capacity: All sizes Particulate Matter 150
1
Substituted by Rule 2 of the Environment (Protection) Amendment Rules, 1996 notified by G.S.R.176(E), dated
2.4.1996 may be read as BOD (3 days at 27oC) wherever BOD 5 days 20oC occurred
2
S.No. 32 to 47 and entries relating thereon inserted vide GSR 742(E) dt. 30.8.90 published in the Gazette No.
365 dated 30.8.90.
The Environment (Protection) Rules, 1986 428
Sr.
No.
Industry Parameter Standards
1 2 3 4
(c) Induction Furnace
Capacity: All sizes Particulate Matter 150
Note : In respect of Arc Furnaces and Induction Furnaces provision has to be made for
collecting the fumes before discharging the emissions through the stack.
33.
THERMAL POWER
PLANTS
STACK HEIGHT/LIMIT IN
METERS
*
Power generation capacity :
- 500 MW and above 275
- 200 MW/210 MW and
above to less than 500
MW
220
- Less than 200 MW/210
MW
H-14(Q)
0.3
where Q is
emission rate of SO2 in
*kg/hr. and *H Stack height
in metres.
Steam generation capacity:
- Less than 2 ton/hr.
½ times the neighbouring
building height or 9 metres
(whichever is more)
- More than 2 ton/hr. to
5 ton/hr.
12
- More than 5 ton/hr. to 10
ton/hr.
15
- More than 10 ton./hr. 18
- More than 15 ton/hr. to
20 ton/hr.
*21
- More than 20 ton/hr. to
25 ton/hr
24
- More than 25 ton/hr. to
30 ton/hr.
27
- More than 30 ton/hr. 30 or using formula H-
14(Q)
0.3
(whichever is more)
Q is emission rate of SO2 in
kg/hr and *H-Stack height in
meters.
*
Correction have been made as per Corrigendum Notification no. S.O. 8(E) dt. 31.12.1990.
The Environment (Protection) Rules, 1986 429
Sr.
No.
Industry Parameter Standards
1 2 3 4
34. SMALL BOILERS EMISSIONS
*
Capacity of Boiler Particulate matter
- Less than 2 ton/hr.
- 2 to 5 ton/hr
More than 15 ton/hr.
1600
1200
150
1
[
2
35. COFFEE
INDUSTRY
Instant/Dry Processing
Limiting value for
concentration in mg/l except
for pH
pH 6.5-8.5
BOD 3 day, 27
o
C 100
Total Dissolved Solids 2100
Wet/Parchment Coffee Processing
pH 6.5-8.5
BOD 3 day, 27
o
C 1000
Notes:
(i) Coffee growers having plantation area less than 10 ha with wet processing shall store
primary treated effluent in lined lagoons for solar evaporation with a non-permeable
system at the base and sides of lagoon.
(ii) Coffee growers having plantation area between 10-25 ha with wet processing shall
store primary (equalization and neutralization) treated effluent in lined lagoons for
solar evaporation with a non-permeable system at the base and sides of lagoon.
(iii) Coffee growers having plantation area 25 ha or above with wet processing shall store
secondary treated effluent in conformity with above norms in lined lagoons with a
non-permeable lining system at the base and side of lagoon and use the effluent for
irrigation after dilution so as BOD of diluted effluent for land application is less than
100 mg/l.
(iv) The minimum liner specifications for a non-permeably lining system shall be a
composite barrier having 1.5 mm High Density Polyethylene (HDPE) geomembrane
or equivalent, overlying 90 cm of soil (clay or amended soil) having permeability
coefficient not more than 1x10-
5
cm/sec.
(v) The effluent storage facilities/lagoons/solar evaporation ponds shall be located above
high flood level mark of the nearby stream, rivulet etc. with below mentioned free
board and away from any water body/stream at a distance.
*
All emissions normalized to 12 per cent carbon dioxide.
1
Omitted entry relating to Oil Refineries (Sulphur Dioxide) by Rule 2 (i) (b) of the Environment (Protection)
Amendment Rules, 2008 notified by G.S.R. 186 (E), dated 18.3.2008.
2
Inserted by Rule 2 of the Environment (Protection) Sixth Amendment Rules, 2008 notified by G.S.R.579(E),
dated 6.8.2008
The Environment (Protection) Rules, 1986 430
Sr.
No.
Industry Parameter Standards
1 2 3 4
Grower Small
(<10ha)
Medium
(10-25ha)
Large
(>25ha)
Free Based
(cm)
30 60 90
Distance (m) 50 100 150
(vi) Raw, Treated and/or diluted effluent shall be discharged
into surface water body or used for recharging groundwater
under any circumstances what so ever].
36. ALUMINIUM
PLANTS:
EMISSIONS
(a) Aluminia Plant:
(i) Raw Material
Handling
Primary and Secondary
Crusher Particulate Matter
150
(ii) Precipitation
Area
- Calcination Particulate matter 250
Carbon Monoxide 1% max.
Stack Height H=14 (Q)
0.3
Where Q is
emission rate of SO2 in kg/hr
and H-Stack height in meters.
(b)Smelter Plant Particulate Matter
(i)Green Anode Shop Particulate Matter 150
1
[(ii)Anode Bake Oven Particulate Matter 50 mg/Nm
3
Total Fluoride (F) 0.3 kg/MT of Aluminium.
(iii)Pot room Particulate matter 150
Total Fluoride
For Soderberg*
Technology
2.8 Kg/ton by
31
st
December 2006
For Pre-baked Technology 0.8 kg/t by 31
st
December
2006
1
Substituted by Rule 2(iv) (a) amended by Rule 2 (IV) (a) of the Environment (Protection) First Amendment
Rules, 2006 notified vide Notification G.S.R.46(E), dated 3.2.2006.
The Environment (Protection) Rules, 1986 431
Sr.
No.
Industry Parameter Standards
1 2 3 4
* Separate standards for VSS, HSS, PBSW & PBCW as given in column 4 stands abolished
1
[(c) Standards for forage
fluoride
- Twelve consecutive months
average
- 40 ppm
- Two consecutive months
average
- 60 ppm
- One month average - 80 ppm]
*
37. STONE CRUSHING
UNIT
Suspended Particulate Matter
(SPM)
The Standards consist of two
paras :
(i) Implementation of the
following Pollution
Control measures:
(a) Dust containment cum
suppression system for
the equipment.
(b) Construction of wind
breaking walls.
(c) Construction of the
metalled roads within
the premises.
(d) Regular cleaning and
wetting of the ground
within the premises.
(e) Growing of a green belt
along the periphery.
1
Inserted by Rule 2(IV)(b) of the Environment (Protection) First Amendment Rules, 2006 notified by
G.S.R.46(E), dated 3.2.2006.
*
Standards notified at Sl. No. 11 may also be referred.
The Environment (Protection) Rules, 1986 432
Sr.
No.
Industry Parameter Standards
1 2 3 4
(ii) Quantitative standard
for SPM :
**
[measured between three
meters and ten metres from
any processes equipment of a
stone crushing unit shall not
exceed 600 microgrammes
per cubic metre] from a
controlled isolated as well as
from a unit located in a
cluster should be less than
600 mg/Nm3
1
[xxx….]
38. PETROCHEMICALS
(BASIC &
INTERMEDIATES)
EFFLUENTS
Ph 6.5 – 8.5
*BOD
2
[(3days at 27
o
C)] 50
**Phenol 5
Sulphide (as S) 2
COD
Cynide (as CN) 250
*** Fluoride (as F)
Total suspended Solids
3
[100]
Hexavalent Chromium
3
[(as
Cr)]
0.1
**** Total Chromium
3
[(as
Cr)]
2.0
**
Corrections have been made as per CORRIGENDUM Notification No. S.O. 8(E) dated 31.12.1990.
1
The sentence ‗The measurements are to be conducted at least twice a month for all the 12 month in a year‘
deleted as per CORRIGENDUM Notification S.O 8(E) dated 31.12.90.
2
Substituted by Rule 2 of the Environment (Protection) Amendment Rules, 1996 notified by G.S.R.176(E), dated
2.4.1996 may be read as BOD (3 days at 27oC) wherever BOD 5 days 20oC occurred.
3
Corrected as per CORRIGENDUM Notification S.O. 8(E) dated 31.12.1990.
The Environment (Protection) Rules, 1986 433
Sr.
No.
Industry Parameter Standards
1 2 3 4
* State Board may prescribed the BOD value of 30 mg/l if the recipient system so
demands.
** The limit for phenol shall be conformed to at the outlet of effluent treatment of
phenol plant. However, at the final disposal point, the limit shall be less than 1
mg/l.
*** The limit for fluoride shall be confirmed to at the outlet of the chrome removal
unit. However, at the disposal point fluoride concentration shall be lower than
5mg/l.
**** The limits for total and hexavalent chromium shall be conformed to at the outlet
of the chromate removal. This implies that in the final treated effluent, total and
hexavalent chromium shall be lower than prescribed herein.
1
[
2
39 HOTEL INDUSTRY EFFLUENT STANDARDS
(i)Hotel with atleast 20 bedrooms
limiting
concentration
in mg/1,
except for
pH
Inland
Surface
Water
On land for
Irrigation
PH 5.5-9.0 5.5-9.0
BOD3 days, 27
o
C 30 100
Total Suspended Solids 50 100
Oil & Grease 10 10
Phosphate as P 1.0 -
(ii)Hotel with less than 20 bedrooms or a Banquet Hall with
minimum floor area of 100m
2
or a Restaurant with minimum
seating capacity of 36
pH 5.5-9.0 5.5-9.0
BOD3 days, 27
o
C 100 100
Total Suspended Solids 100 100
Oil & Grease 10 10
1
Omitted entry relating to Pharmaceutical Manufacturing and Formulation Industry by Rule 2(a) of the
Environment (Protection) Third Amendment Rules, 2009 notified by G.S.R.512(E), dated 9.7.2009.
2
Inserted by Rule of the Environment (Protection) Sixth Amendment Rules, 2009 notified by G.S.R.794(E),
dated 4.11.2009.
The Environment (Protection) Rules, 1986 434
Sr.
No.
Industry Parameter Standards
1 2 3 4
Notes:
i. Hotels, banquet halls, restaurants, etc. located in
coastal area shall also comply with the provisions of
the Coastal Regulation Zone, as applicable.
ii If, the effluent is discharged into a municipal sewer
leading to a Sewage Treatment Plant, the hotel or
restaurant or banquet hall, as the case may be, shall
provide a proper Oil and Grease Trap for effluent
arising from its kitchen and laundry and shall have to
comply with the 'General Standards for Discharge of
Environmental Pollutants Part-A: Effluents' notified
under Schedule-VI].
40. PESTICIDE
MANUFACTURING
AND FORMULATION
INDUSTRY.
EFFLUENTS
1. Temperature Shall not exceed 5
o
C above
the receiving water
temperature
2. pH 6.5 – 8.5
3. Oil and Grease 10
4. BOD
1
[(3 days at 27
o
C)] 30
5. Total Suspended Solids 100
6. Bio-assay test 90% survival of fish after 96
hours in 100% effluent.
7. (a) Specific Pesticides :
Benzenl Hexachloride 10
Carbonyl 10
DDT 10
Endosulfan 10
Diamethoate 450
Fenitrothion 10
Malathion 10
1
Substituted by Rule 2 of the Environment (Protection) Amendment Rules, 1996 notified by G.S.R.176(E), dated
2.4.1996 may be read as BOD (3 days at 27oC) wherever BOD 5 days 20oC occurred.
The Environment (Protection) Rules, 1986 435
Sr.
No.
Industry Parameter Standards
1 2 3 4
Phorate 10
Methyl Parathion 10
Phenathoate 10
Pyrethrums 10
Copper Oxyghloride 9600
Copper Sulphate 50
Ziram 1000
Sulphur 30
Paraquat 2300
Proponil 7300
Nitrogen 780
(b) Heavy Metals
Copper 1.00
Managanese 1.00
Zinc 1.00
Mercury 0.01
Tin 0.10
Any other metal like Nickel
etc.
Shall not exceed 5 times the
drinking water standards of
BIS.
(c) Organics
Phenol and Phenolic
compounds as C6H5OH
1.0
(d) Inorganics
Arsenics (As As) 0.2
Cyanide (as CN) 0.2
Nitrate (as NO3) 50.0
Phosphate (as P) 5.0
The Environment (Protection) Rules, 1986 436
Sr.
No.
Industry Parameter Standards
1 2 3 4
1
[EMISSIONS Not to exceed
mg/Nm
3
HCl 20
Cl2 5
H2S 5
P2O5 (as H3PO4) 10
NH3 30
Particulate matter with
pesticides compounds
20
CH3Cl 20
HBr 5]
Note : 1. Limits should be complied with the end of the treatment plant before
any dilution.
2. Bio-assay test should be carried out with available species of fish in
receiving water.
3. State Boards may prescribe limits of total dissolved solids (TDS) sulphates
and chlorides depending on the uses of recipient water body.
4. State Board may prescribe COD limit correlated with BOD limit.
5. Pesticides are known to have metabolites and isomers. If they are found
insignificant concentration, standards may be prescribed for those in the
list by Central or State Board.
6. Industries are required to analyse pesticides in waste water by
advanced analytical method such as GLC/HPLC.
7. All the parameters will be compulsory for formulators, for others, the 7
th
will be optional.
1
Inserted entries relating to emissions by Rule 2(V) of the Environment (Protection) First Amendment Rules,
2006 notified vide G.S.R.46(E), dated 3.2.2006.
The Environment (Protection) Rules, 1986 437
Sr.
No.
Industry Parameter Standards
1 2 3 4
41. TANNERY (AFTER
PRIMARY
TREATMENT)
Disposal : Channel/
conduit
Carrying waste waters to
Secondary Treatment
Plants
Type of Tanners :
EFFLUENT
- chrome tanneries/
combined chrome &
Vegetable tanneries.
pH 6.5 – 9.0
SS Not to exceed 600
Chromium Concentration after
treatment in the chrome waste
water stream
45
- Vegetable tanneries pH 6.5 – 9.0
SS Not to exceed 600
Note : The above standards will apply to those tannery units which have made full
contribution to a Common Effluent Treatment Plant (CETP) Comprising
secondary treatment. Those who have not contributed will be governed by earlier
Notification No. S.O.
*
61 (E), dated January 18, 1988.
42. PAINT INDUSTRY
WASTE WATER
DISCHARGE
EFFLUENTS
pH 6.0 – 8.5
Suspended Solids 100
BOD5
1
[(3 days at 27
o
C)] 50
Phenolics as C6H5OH 1.0
Oil and Grease 10.0
Bio-assay test 90% survival in 96 hours
Lead as Pb 0.1
*
Corrected as per Notification No. S.O. 8(E) dated 31.12.1990.
1
Substituted by Rule 2 of the Environment (Protection) Amendment Rules, 1996 notified by G.S.R.176(E), dated
2.4.1996 may be read as BOD (3 days at 27oC) wherever BOD 5 days 20oC occurred
The Environment (Protection) Rules, 1986 438
Sr.
No.
Industry Parameter Standards
1 2 3 4
Chromium as Cr Hexavalent 0.1
Total 2.0
Copper as Cu 2.0
Nickle as Ni 2.0
Zinc as Zn 5.0
Total heavy metals 7.0
43. INORGANIC
CHEMICAL
INDUSTRY (WASTE
WATER
DISCHARGE)
EFFLUENTS
part I (metal compounds
of Chromium,
Manganese, Nickel,
Copper, Zinc, Cadmium,
Lead and Mercury)
pH 6.0 – 8.5
Chromium as Cr Hexavalent 0.1
Total 2.0
Manganese as Mn 2.0
Nickel as Ni 2.0
Copper as Cu 2.0
Zinc as Zn 5.0
Cadmium as Cd 0.2
Lead as Pb 0.1
Mercury as Hg .01
Cynide as CN 0.2
Oil & Grease 10.0
Suspended Solids 30.0
In addition to the above, total
heavy metals are to be limited to
7 mg/l.
The Environment (Protection) Rules, 1986 439
Sr.
No.
Industry Parameter Standards
1 2 3 4
44. BULLION REFINING
(WASTE WATER
DISCHARGE)
EFFLUENTS
pH 6.5 – 8.5
Cynide as CN 0.2
Sulphide as S 0.2
Nitrate as N 10.0
Free C12 as C1 1.0
Zinc as Zn 5.0
Copper as Cu 2.0
Nickel as Ni 2.0
Arsenic as As 0.1
Cadmium as Cd 0.2
Oil and Grease 10.0
Suspended Solids 100
*
45. DYE & DYE
INTERMEDIATE
INDUSTRY (WASTE
WATER
DISCHARGE)
EFFLUENTS
pH 6.0 – 8.5
Colour Hazen Unit 400.0
Suspended Solids 100.0
BOD
1
[(3 days at 27
o
C)] 100.0
Oil and Grease 10.0
Phenolics as C6H5OH 1.00
Cadmium as Cd 0.2
Copper as Cu 2.0
Manganese as Mn 2.0
Lead as Pb 0.1
Mercury as Hg 0.01
Nickel as Ni 2.0
Zinc as Zn 5.0
Chromium as Cr
6+
0.1
Total Chromium 2.0
Bio-assay test 90% survival in 96 hours.
*
Standards Notified as Sl. No. 8 may also be referred.
1
Substituted by Rule2 of the Environment (Protection) Amendment Rules, 1996 notified by G.S.R.176(E), dated
2.4.1996 may be read as BOD (3 days at 27oC) wherever BOD 5 days 20oC occurred
The Environment (Protection) Rules, 1986 440
Sl.No. Category Standards
dB(A)
1 2 3
46. NOISE LIMITS FOR AUTOMOBILES (FREE FIELD) AT ONE
METER IN dB(A) AT THE MANUFACTURING STAGE TO BE
ACHIEVED BY THE YEAR 1992.
(a) Motorcycle, Scooters & Three wheelers 80
(b) Passenger Cars 82
(c) Passenger or Commercial Vehicles upto 4 MT 85
(d) Passenger or Commercial Vehicles above 4 MT and upto 12 MT 89
(e) Passenger or Commercial Vehicles exceeding 12 MT 91
47. DOMESTIC APPLIANCES AND CONSTRUCTION EQUIPMENTS
AT THE MANUFACTURING STAGE TO BE ACHIEVED BY THE
YEAR, 1993
(a) Window Air Conditioner of 1 ton to 1.5 tons 68
(b) Air Coolers 60
(c) Refrigerators 46
1
[(d) ***……… - ]
(e) Compactors (rollers) Front loaders, Concrete mixers, Cranes
(movable), Vibrators and Saws.
75
1
The words and figures ‗Diesel generators for domestic purposes … 85-90‘ omitted by Rule 2(a) of the
Environment (Protection) Second Amendments Rules, 2002 published vide Notification No.G.S.R.371(E),
dated 17.5.2005
The Environment (Protection) Rules, 1986 441
Sr.
No.
Industry Parameter Standards
1 2 3 4
1
48. GLASS INDUSTRY EMISSIONS
A. Sodalime & Borosilicate
and other special Glass
(other than Lead)
(a) Furnace : Capacity
(i) Upto a product draw
capacity of 60 MT/Day
Particulate Matter 2.0 kg/hr.
(ii) Product draw capacity
more than 6 MT/Day
Particulate Matter 0.8 kg/MT of product
drawn
(iii) For all capacities Stack height H=14(Q)
0.3
where Q
is the emission rate of
SO2 in Kg/hr. & H is
Stack height in
meters.
Total Fluorides 5.0 mg/NM
3
Nox Use of low Nox
burners in new plants
(b) Implementation of the following measures for fugitive emission control from other
sections :
(i) Raw materials should be transported in leak proof containers.
(ii) Cullet preparation should be dustfree using water spraying.
(iii) Batch preparation section should be covered.
B. Lead Glass
(a) Furnaces :
All capacities Particulate Matter 50 mg/NM
3
Lead 20 mg/NM
3
(b) Implementation of the following measures for fugitive emission control from other
sections:
(i) Batch mixing, proportioning section and transfer points should be covered and it
should be connected to control equipments to meet the following standards :
Particulate matter 50 mg/NM
3
Lead 20 mg/NM
3
(ii) Minimum Stack height should be 30 metres in lead glass units.
(c) Pot furnace at Firozabad
Furnace :
Particulate matter 1200 mg/NM
3
Note : Depending upon local environmental conditions, State/Central Pollution Control Board can
prescribe more stringent standards than those prescribed above.
1
S.No. 48 to 55 and entries relating thereto inserted vide GSR 93(E) dt. 21.2.91 published in the Gazette No. 79
dated 27.2.91.
The Environment (Protection) Rules, 1986 442
Sr.
No.
Industry Parameter Standards
1 2 3 4
Glass Industries (for all
categories)
EFFLUENTS:
pH 6.5 – 8.5
Total Suspended Solids 100 mg/l
Oil & Grease 10 mg/l
49. LIME KILN Stack Height
Capacity :
Upto 5 T/day Stack Height A hood should be provided
with a stack of 30 meter
height from ground level
(including kiln height).
Above 5T/day Stack height H=14(Q)
0.3
where Q is
emission rate of SO2 in
kg/hr and H=Stack Height
in meters.
More than 5T/day and up to 40
T/Day
Particulate matter 500 mg/Nm
3
Above 40T/day Particulate matter 150 mg/Nm
3
50.
SLAUGHTER HOUSE,
MEAT & SEA FOOD
INDUSTRY
EFFLUENTS Concentration in mg/l
Category
A.Slaughter House
(a) Above 70 TLWK/day BOD
1
[3 days at 27
o
C] 100
Suspended Solids 100
Oil and Grease 10
(b) 70 TLWK/day below BOD
1
[3 days at 27
o
C] 500
B.Meat Processing
(a) Frozen Meat BOD
1
[3 days at 27
o
C] 30
Suspended Solids 50
Oil & Grease 10
(b) Raw Meat from own
Slaughter House.
BOD
1
[3 days at 27
o
C] 30
Suspended Solids 50
Oil & Grease 10
(c) Raw Meat from other
sources
Disposal via Screen and
Septic Tank.
C.Sea Food Industry BOD
1
[3 days at 27
o
C] 30
Suspended Solids 50
Oil and Grease 10
The emission standards from Boiler House shall conform to the standards already prescribed under E(P) Act,
1986 vide notification No.G.S.R.742(E), dated 30.8.90.
1
Substituted by Rule 2 of the Environment (Protection) Amendment Rules, 1996 notified by G.S.R.176(E), dated
2.4.1996 may be read as BOD (3 days at 27oC) wherever BOD 5 days 20oC occurred.
The Environment (Protection) Rules, 1986 443
Sr.
No.
Industry Parameter Standards
1 2 3 4
Note : (i) TLWK – Tonnes of Live Weight Killed (ii) In case of disposal into municipal sewer
where sewage is treated the industries shall install screen and oil & grease separation units.
(iii) The industries having slaughter house along with meat processing units will be
considered in meat processing category as far as standards are concerned.
51. FOOD AND FRUIT
PROCESSING INDUSTRY:
EFFLUENTS Concentration
not to exceed –
mg/l except pH
Quantum
gm/MT of
product
Category
A. Soft Drinks
(a) Fruit based/ Synthetic
(more than 0.4 MT/Day)
bottles and tetrapack
pH 6.5 – 8.5 -
Suspended Solids 100
Oil and Grease 10
BOD
1
[3days at
27
o
C]
30
(b) Synthetic (less than 0.4
MT/Day)
Disposal via
septic Tank
-
B. Fruit & Vegetables
(a) Above 0.4 MT/Day pH 6.5 – 8.5 -
Suspended Solids 50
Oil and Grease 10
BOD
1
[3days at 27
o
C] 30
(b) 0.1-0.4 MT/day (10
MT/year)
Disposal via
septic Tank
-
C. Bakery
(a) Bread and Bread &
Biscuit
(i) Continuous process
(More than 20T/day)
pH 6.5 - 8.5 -
BOD
1
[3days at 27
o
C] 200 25
1
Substituted by Rule 2 of the Environment (Protection) Amendment Rules, 1996 notified by G.S.R.176(E), dated
2.4.1996 may be read as BOD (3 days at 27oC) wherever BOD 5 days 20oC occurred.
The Environment (Protection) Rules, 1986 444
Sr.
No.
Industry Parameter Standards
1 2 3 4
(ii) Non-continuous
process (less than 20
MT/day)
- Disposal via
Septic tank
(b) Biscuit Production
(i) 10 T/day & above
pH 6.5 – 8.5
BOD
1
[3days at27
o
C] 300 35
D. Confectioneries EFFLUENTS
(a) 4 T/day and above pH 6.5 – 8.5 -
Suspended Solids 50
Oil and Grease 10
BOD
1
[3days at
27
o
C]
30
(b) Below 4 T/day Disposal via
Septic Tank
Note : To ascertain the category of ‗unit fails‘ the average of daily production and waste
water discharge for the preceding 30 operating days from the date of sampling
shall be considered.
* The emission from the boiler house shall conform to the standards already
prescribed under E(P) Act, 1986 vide Notification No. GSR 742(E) dated
30.8.90.
52. *JUTE PROCESSING
INDUSTRY :
EFFLUENTS Concentration in mg/l
except pH and Water
consumption
pH 5.5 – 9.0
BOD
1
[3days at 27
o
C] 30
Suspended Solids 100
Oil and Grease 10
Water Consumption 1.60 Cum/Ton of product
produced.
1
Substituted by Rule 2 of the Environment (Protection) Amendment Rules, 1996 notified by G.S.R.176(E), dated
2.4.1996 may be read as BOD (3 days at 27oC) wherever BOD 5 days 20oC occurred.
The Environment (Protection) Rules, 1986 445
Sr.
No.
Industry Parameter Standards
1 2 3 4
Note : 1. Water Consumption for the Jute processing industry will be 1.5 Cum/Ton of
product from January, 1992.
2. At the present no limit for colour is given for liquid effluent. However, as
far as possible colour should be removed.
* Stack emissions from boiler house shall conform to the standards already
prescribed under Environment (Protection) Act, 1986, vide Notification No.
GSR 742(E), dated 30.08.90.
53. LARGE PULP & PAPER
NEWS PRINT/ RAYON
GRADE PLANTS OF
1
[CAPACITY ABOVE 24000
MT PER ANNUM]
EFFLUENTS Concentration in mg/l
except pH and TOCL
pH 7.0 – 8.5
BOD
2
[3 days at 27
o
C] 30
COD 350
Suspended Solids 500
3
[Absorbable Organic
Halogens (AOX) in
effluent discharge
1.5 kg/ton of product with
effect from the date of
publication of this
notification.1.0 kg/ton of
product with effect from
the 1
st
day of March,2008.]
Flow (Total Waste
Water Discharge)
**
(i)Large Pulp & Paper 200 Cum/Ton of Paper
produced
(ii)Large Rayon Grade
Newsprint
150 Cum/Ton of Paper
produced.
54. SMALL PULP AND PAPER EFFLUENT
Paper Plant of Capacity
upto 24000 MT/Annum :
Category :
A. *Agrobased Total waste water
discharge
200 cum/Ton of paper
produced
B. **Waste paper based Total waste water
discharge
75 cum/Ton of paper
produced
1
Substituted by Rule 2(ii) (a) of the Environment (Protection) Third Amendments Rules, 2005 notified vide
Notification No.G.S.R.546(E), dated 30.8.2005.
2
Substituted by Rule 2 of the Environment (Protection) Amendment Rules, 1996 notified by G.S.R.176(E), dated
2.4.1996 may be read as BOD (3 days at 27oC) wherever BOD 5 days 20oC occurred
3
Substituted by Rule 2(ii) (b) of the Environment (Protection) Third Amendments Rules, 2005 notified vide
Notification No.G.S.R.546(E), dated 30.8.2005
**
The Standards with respect of total wastewater discharge for the large pulp and paper mills be established from
1992, will meet the standards of 100 cum/Ton of paper produced.
The Environment (Protection) Rules, 1986 446
Sr.
No.
Industry Parameter Standards
1 2 3 4
* The agro based mills to be established from January, 1992 will meet the standards
of 150 cum/Ton of paper produced.
** The waste-paper mills to be established from January, 1992 will meet the
standards of 50 cum/Tom of paper produced.
55. COMMON EFFLUENT
TREATMENT PLANTS:
EFFLUENTS
(Inlet effluent quality for
CETP)
(Concentration in mg/l)
A. Primary Treatment pH 5.5 – 9.0
Temperature
o
C 45
Oil & Grease 20
Phenolic Compounds (as
C6H5OH)
5.0
Ammonical Nitrogen
(as N)
50
Cynide (as CN) 2.0
Chromium hexavalent (as
Cr+6)
2.0
Chromium (total)(as Cr) 2.0
Copper (as Cu) 3.0
Lead (as Pb) 1.0
Nickel (as Ni) 3.0
Zinc (as Zn) 15
Arsenic (as As) 0.2
Mercury (as Hg) 0.01
Cadmium (as Cd) 1.0
Selenium (as Se) 0.05
Fluoride (as F) 15
Boron (as B) 2.0
Radioactive Materials
Alpha emitters, Hc/ml 10-7
Beta emitters, He/ml 10-8
The Environment (Protection) Rules, 1986 447
Sr.
No.
Industry P
Previous and next
Questions people ask
Is form OF LABORATORY REPORT THEREON of Environment (Protection) Rules, 1986. still in force?
No repeal of Environment (Protection) Rules, 1986. is recorded.