Rule 18, THE ENVIRONMENT (PROTECTION) RULES, 1986: OMITTED
THE ENVIRONMENT (PROTECTION) RULES, 1986 - Rule 18 - Omitted
Omitted
This rule is omitted.
Text of rule 18
OMITTED
[18. OMITTED
19. CALCIUM CARBIDE Particulate Matter
Emission
- Kiln 250 milligramme per normal cubic
metre.
- Arc Furnace 150 milligramme per normal cubic
metre.
20. CARBON BLACK Particulate matter
Emission
150 milligramme per normal cubic
metre.
21. COPPER, LEAD AND
ZINC SMELTING
Particulate Matter
Emission in
Concentrator
150 milligramme per normal cubic
metre.
Emission of Oxides of
Sulphur in Smelter &
convertor
Off-gases must be utilized for
sulphuric acid manufacture. The
limits of sulphur dioxide emission
from stock shall not exceed 4
kilogramme per tonne of concentrated
(one hundred per cent acide
produced).
22. NITRIC ACID
(EMISSION OXIDES
OF NITROGEN)
Emission of Oxides of
Nitrogen
3 kilogramme of oxides of nitrogen
per tonne of weak acid (before
concentration) produced.
2
[23. SULPHURIC ACID
PLANT
Emission standards
Limiting
concentration in
mg/Nm
3
,
unless stated
Plant capacity for
100% concentration
of Sulphuric Acid
(tonne/day)
1
Sr. No.18 relating to “Aluminum” and entries relating thereto omitted by Rule 2(II) of the Environment
(Protection) First Amendment Rules, 2006 notified by G.S.R. 46(E), dated 3.2.2006.
2
Substituted by Rule 2(I) of the Environment (Protection) Third Amendment Rules, 2008 notified by G.S.R.
344(E), dated 7.5.2008.
The Environment (Protection) Rules, 1986 424
Sr.
No.
Industry Parameter Standards
1 2 3 4
Existing Unit New Unit
Sulphur dioxide (SO2) upto 300 1370 1250
Above 300 1250 950
Acid Mist/Sulphur Up to 300 90 70
Trioxide Above 300 70 50
Note:
(i) Scrubbing units shall have on-line pH meters with auto recording facility.
(ii) The height of the stack emitting sulphur-dioxide or acid mist shall be of minimum of
30 metre or as per the formula H=14(Q)
(0.3)
(whichever is more). Where ―H‖ is the
height of stack in metre; and ―Q‘ is the maximum quantity of SO2 expected to be
emitted through the stack at 110 per cent rated capacity of the plants and calculated as
per the norms of gaseous emission.
(iii) Plants having more than one stream or unit of sulphuric acid at one location, the
combined capacity of all the streams and units shall be taken into consideration for
determining the stack height and applicability of emission standards.
(iv) Plants having separate stack for gaseous emission for the scrubbing unit, the height of
this stack shall be equal to main stack].
24. IRON & STEEL
(INTEGRATED)
Particulate Matter
Emission
- Sintering Plant 150 milligramme per normal cubic
metre
- Steel making
-- during normal
operations
150 milligramme per normal cubic
metre.
--during oxygen
lancing
400 milligramme per normal cubic
metre.
- Rolling Mill 150 milligramme per normal cubic
metre.
- Carbon monoxide
from coke oven
3 kilogramme per tonne of coke
produced.
The Environment (Protection) Rules, 1986 425
Sr.
No.
Industry Parameter Standards
1 2 3 4
1
25. THERMAL POWER
PLANTS
Particulate Matter
Emissions :
- generation cpacity
210 MW or more
150 millogramme per normal cubic
metre.
- generation capacity
less than 210 MW
350 milligramme per normal cubic
metre.
26. NATURAL RUBBER
INDUSTRY
Concentrations in the effluents not to
exceed milligramme per litre (except
for pH) 44
o
C
- Discharge into inland
surface water
Colour & odour Absent
pH 6.0 – 9.0
BOD 50
COD 250
Oil and Grease 10
Sulphides 2
Total Kjeldahl
Nitrogen
100
Dissolved phosphate
(as P)
5
Suspended Solids 100
Dissolved solids
(inorganic)
2100
Ammonical Nitrogen
as N
50
Free ammonia (as
NH3)
5
-Disposal on land for
irrigation
Colour and Odour Absent
pH 6.0 – 8.0
BOD 100
COD 250
Oil & Grease 10
Suspended Solids 200
Dissolved solids 2100
1
S. No. 25 and 26 and entries relating thereto inserted vide S.O. 8(E) dt. 3.1.89 published in the Gazette No. 7
dated. 3.1.89.
Corrections in rule 2 against S.No. 26 made vide corrigendum No. S.O. 190 (E) dt. 15.3.89 published in the
Gazette no. 126 dt. 15.3.89.
Depending upon the requirement of local situation, such as protected area, the State Pollution Control Board
and other implementation agencies under the Environment (Protection) Act, 1986 may prescribed a limit of 150
milligramme per normal cubic meter, irrespective of generation capacity of the plant.
The Environment (Protection) Rules, 1986 426
Sr.
No.
Industry Parameter Standards
1 2 3 4
1
[
2
27. ASBESTOS
MANUFACTURING
UNITS (INCLUDING
ALL PROCESSES
INVOLVING THE
USE OF ASBESTOS)
- Pure Asbestos
material
0.5 fibre */cc for one year from the
date of notification
0.2 fibre */cc after one year from the
date of notification]
- Total Dust 2 mg/m
3
(normal)
28.
CALOR ALKALI
(CAUSTIC SODA)
EMISSIONS Concentration in mg/m
3
(normal)
(a) Mercury Cell Mercury (from
hydrogen gas holder
stack)
0.2
(b) All processes Chlorine (from hypo
tower)
15.0
(c) All processes Hydro chloric acid
vapours and mist
(from hydro chloric
acid plant)
35.0
29. LARGE PULP AND
PAPER
EMISSIONS Concentration in mg/m
3
(normal)
Particulate matter 250
**
H2S 10
30. INTEGRATED IRON
AND STEEL
PLANTS:
I. EMISSIONS
(a) Coke Oven Particulate mater 50
(b) Refractory
material plant
Particulate matter 150
II. EFFLUENTS Concentration in mg/l except for pH.
(a) Coke oven
By product plant. pH 6.0 – 8.0
Suspended Solids 100
1
Standards mentioned at Sl. No.27 amended by Rule 2(III) of the Environment (Protection) First Amendment
Rules, 2006 notified vide Notification G.S.R.46(E), dated 3.2.2006.
2 S.No. 27 to 31 and entries relating thereto inserted vide GSR 913(E) dt. 24.10.89 published in the Gazette No.
554 dt. 24.10.89.
**
This standard of 250 mg/m3 (normal) shall apply only for a period of 3 years with effect from the date on which
the Environment (protection) Second Amendment Rules, 1989 came into force. After three years the standard to
be applicable is 15 mg/m3 (normal).
The Environment (Protection) Rules, 1986 427
Sr.
No.
Industry Parameter Standards
1 2 3 4
Phenol 1.0
Cynide 0.2
BOD
1
[(3 days at
27
o
C)]
30
COD 250
Ammonical Nitrogen 50
Oil and Grease 10
(b)Other plants such as
sintering plant, blast
furnace, steel melting
and rolling mill:
pH
6.0 – 9.0
Suspended Solids 100
Oil and Grease 10
31. RE-HEATING
(REVERBERATORY)
FURNACES:
EMISSIONS Concentration in mg/m
3
(normal)
Capacity : All sizes
Sensitive area Particulate matter 150
Other area Particulate matter 450
2
[32. FOUNDRIES EMISSIONS
(a) Cupola Capacity
(Melting Rate) :
Less than 3 mt./hr. Particulate Matter 450
3 mt/hr. and above Particulate Matter 150
Note : It is essential that stack is constructed over the cupola beyond the charging door
and emissions are directed through the stack which should be at least six times the
diameter of cupola.
(b) Arc Furnaces :
Capacity: All sizes Particulate Matter 150
1
Substituted by Rule 2 of the Environment (Protection) Amendment Rules, 1996 notified by G.S.R.176(E), dated
2.4.1996 may be read as BOD (3 days at 27oC) wherever BOD 5 days 20oC occurred
2
S.No. 32 to 47 and entries relating thereon inserted vide GSR 742(E) dt. 30.8.90 published in the Gazette No.
365 dated 30.8.90.
The Environment (Protection) Rules, 1986 428
Sr.
No.
Industry Parameter Standards
1 2 3 4
(c) Induction Furnace
Capacity: All sizes Particulate Matter 150
Note : In respect of Arc Furnaces and Induction Furnaces provision has to be made for
collecting the fumes before discharging the emissions through the stack.
33.
THERMAL POWER
PLANTS
STACK HEIGHT/LIMIT IN
METERS
*
Power generation capacity :
- 500 MW and above 275
- 200 MW/210 MW and
above to less than 500
MW
220
- Less than 200 MW/210
MW
H-14(Q)
0.3
where Q is
emission rate of SO2 in
*kg/hr. and *H Stack height
in metres.
Steam generation capacity:
- Less than 2 ton/hr.
½ times the neighbouring
building height or 9 metres
(whichever is more)
- More than 2 ton/hr. to
5 ton/hr.
12
- More than 5 ton/hr. to 10
ton/hr.
15
- More than 10 ton./hr. 18
- More than 15 ton/hr. to
20 ton/hr.
*21
- More than 20 ton/hr. to
25 ton/hr
24
- More than 25 ton/hr. to
30 ton/hr.
27
- More than 30 ton/hr. 30 or using formula H-
14(Q)
0.3
(whichever is more)
Q is emission rate of SO2 in
kg/hr and *H-Stack height in
meters.
*
Correction have been made as per Corrigendum Notification no. S.O. 8(E) dt. 31.12.1990.
The Environment (Protection) Rules, 1986 429
Sr.
No.
Industry Parameter Standards
1 2 3 4
34. SMALL BOILERS EMISSIONS
*
Capacity of Boiler Particulate matter
- Less than 2 ton/hr.
- 2 to 5 ton/hr
More than 15 ton/hr.
1600
1200
150
1
[
2
35. COFFEE
INDUSTRY
Instant/Dry Processing
Limiting value for
concentration in mg/l except
for pH
pH 6.5-8.5
BOD 3 day, 27
o
C 100
Total Dissolved Solids 2100
Wet/Parchment Coffee Processing
pH 6.5-8.5
BOD 3 day, 27
o
C 1000
Notes:
(i) Coffee growers having plantation area less than 10 ha with wet processing shall store
primary treated effluent in lined lagoons for solar evaporation with a non-permeable
system at the base and sides of lagoon.
(ii) Coffee growers having plantation area between 10-25 ha with wet processing shall
store primary (equalization and neutralization) treated effluent in lined lagoons for
solar evaporation with a non-permeable system at the base and sides of lagoon.
(iii) Coffee growers having plantation area 25 ha or above with wet processing shall store
secondary treated effluent in conformity with above norms in lined lagoons with a
non-permeable lining system at the base and side of lagoon and use the effluent for
irrigation after dilution so as BOD of diluted effluent for land application is less than
100 mg/l.
(iv) The minimum liner specifications for a non-permeably lining system shall be a
composite barrier having 1.5 mm High Density Polyethylene (HDPE) geomembrane
or equivalent, overlying 90 cm of soil (clay or amended soil) having permeability
coefficient not more than 1x10-
5
cm/sec.
(v) The effluent storage facilities/lagoons/solar evaporation ponds shall be located above
high flood level mark of the nearby stream, rivulet etc. with below mentioned free
board and away from any water body/stream at a distance.
*
All emissions normalized to 12 per cent carbon dioxide.
1
Omitted entry relating to Oil Refineries (Sulphur Dioxide) by Rule 2 (i) (b) of the Environment (Protection)
Amendment Rules, 2008 notified by G.S.R. 186 (E), dated 18.3.2008.
2
Inserted by Rule 2 of the Environment (Protection) Sixth Amendment Rules, 2008 notified by G.S.R.579(E),
dated 6.8.2008
The Environment (Protection) Rules, 1986 430
Sr.
No.
Industry Parameter Standards
1 2 3 4
Grower Small
(<10ha)
Medium
(10-25ha)
Large
(>25ha)
Free Based
(cm)
30 60 90
Distance (m) 50 100 150
(vi) Raw, Treated and/or diluted effluent shall be discharged
into surface water body or used for recharging groundwater
under any circumstances what so ever].
36. ALUMINIUM
PLANTS:
EMISSIONS
(a) Aluminia Plant:
(i) Raw Material
Handling
Primary and Secondary
Crusher Particulate Matter
150
(ii) Precipitation
Area
- Calcination Particulate matter 250
Carbon Monoxide 1% max.
Stack Height H=14 (Q)
0.3
Where Q is
emission rate of SO2 in kg/hr
and H-Stack height in meters.
(b)Smelter Plant Particulate Matter
(i)Green Anode Shop Particulate Matter 150
1
[(ii)Anode Bake Oven Particulate Matter 50 mg/Nm
3
Total Fluoride (F) 0.3 kg/MT of Aluminium.
(iii)Pot room Particulate matter 150
Total Fluoride
For Soderberg*
Technology
2.8 Kg/ton by
31
st
December 2006
For Pre-baked Technology 0.8 kg/t by 31
st
December
2006
1
Substituted by Rule 2(iv) (a) amended by Rule 2 (IV) (a) of the Environment (Protection) First Amendment
Rules, 2006 notified vide Notification G.S.R.46(E), dated 3.2.2006.
The Environment (Protection) Rules, 1986 431
Sr.
No.
Industry Parameter Standards
1 2 3 4
* Separate standards for VSS, HSS, PBSW & PBCW as given in column 4 stands abolished
1
[(c) Standards for forage
fluoride
- Twelve consecutive months
average
- 40 ppm
- Two consecutive months
average
- 60 ppm
- One month average - 80 ppm]
*
37. STONE CRUSHING
UNIT
Suspended Particulate Matter
(SPM)
The Standards consist of two
paras :
(i) Implementation of the
following Pollution
Control measures:
(a) Dust containment cum
suppression system for
the equipment.
(b) Construction of wind
breaking walls.
(c) Construction of the
metalled roads within
the premises.
(d) Regular cleaning and
wetting of the ground
within the premises.
(e) Growing of a green belt
along the periphery.
1
Inserted by Rule 2(IV)(b) of the Environment (Protection) First Amendment Rules, 2006 notified by
G.S.R.46(E), dated 3.2.2006.
*
Standards notified at Sl. No. 11 may also be referred.
The Environment (Protection) Rules, 1986 432
Sr.
No.
Industry Parameter Standards
1 2 3 4
(ii) Quantitative standard
for SPM :
**
[measured between three
meters and ten metres from
any processes equipment of a
stone crushing unit shall not
exceed 600 microgrammes
per cubic metre] from a
controlled isolated as well as
from a unit located in a
cluster should be less than
600 mg/Nm3
1
[xxx….]
38. PETROCHEMICALS
(BASIC &
INTERMEDIATES)
EFFLUENTS
Ph 6.5 – 8.5
*BOD
2
[(3days at 27
o
C)] 50
**Phenol 5
Sulphide (as S) 2
COD
Cynide (as CN) 250
*** Fluoride (as F)
Total suspended Solids
3
[100]
Hexavalent Chromium
3
[(as
Cr)]
0.1
**** Total Chromium
3
[(as
Cr)]
2.0
**
Corrections have been made as per CORRIGENDUM Notification No. S.O. 8(E) dated 31.12.1990.
1
The sentence ‗The measurements are to be conducted at least twice a month for all the 12 month in a year‘
deleted as per CORRIGENDUM Notification S.O 8(E) dated 31.12.90.
2
Substituted by Rule 2 of the Environment (Protection) Amendment Rules, 1996 notified by G.S.R.176(E), dated
2.4.1996 may be read as BOD (3 days at 27oC) wherever BOD 5 days 20oC occurred.
3
Corrected as per CORRIGENDUM Notification S.O. 8(E) dated 31.12.1990.
The Environment (Protection) Rules, 1986 433
Sr.
No.
Industry Parameter Standards
1 2 3 4
* State Board may prescribed the BOD value of 30 mg/l if the recipient system so
demands.
** The limit for phenol shall be conformed to at the outlet of effluent treatment of
phenol plant. However, at the final disposal point, the limit shall be less than 1
mg/l.
*** The limit for fluoride shall be confirmed to at the outlet of the chrome removal
unit. However, at the disposal point fluoride concentration shall be lower than
5mg/l.
**** The limits for total and hexavalent chromium shall be conformed to at the outlet
of the chromate removal. This implies that in the final treated effluent, total and
hexavalent chromium shall be lower than prescribed herein.
1
[
2
39 HOTEL INDUSTRY EFFLUENT STANDARDS
(i)Hotel with atleast 20 bedrooms
limiting
concentration
in mg/1,
except for
pH
Inland
Surface
Water
On land for
Irrigation
PH 5.5-9.0 5.5-9.0
BOD3 days, 27
o
C 30 100
Total Suspended Solids 50 100
Oil & Grease 10 10
Phosphate as P 1.0 -
(ii)Hotel with less than 20 bedrooms or a Banquet Hall with
minimum floor area of 100m
2
or a Restaurant with minimum
seating capacity of 36
pH 5.5-9.0 5.5-9.0
BOD3 days, 27
o
C 100 100
Total Suspended Solids 100 100
Oil & Grease 10 10
1
Omitted entry relating to Pharmaceutical Manufacturing and Formulation Industry by Rule 2(a) of the
Environment (Protection) Third Amendment Rules, 2009 notified by G.S.R.512(E), dated 9.7.2009.
2
Inserted by Rule of the Environment (Protection) Sixth Amendment Rules, 2009 notified by G.S.R.794(E),
dated 4.11.2009.
The Environment (Protection) Rules, 1986 434
Sr.
No.
Industry Parameter Standards
1 2 3 4
Notes:
i. Hotels, banquet halls, restaurants, etc. located in
coastal area shall also comply with the provisions of
the Coastal Regulation Zone, as applicable.
ii If, the effluent is discharged into a municipal sewer
leading to a Sewage Treatment Plant, the hotel or
restaurant or banquet hall, as the case may be, shall
provide a proper Oil and Grease Trap for effluent
arising from its kitchen and laundry and shall have to
comply with the 'General Standards for Discharge of
Environmental Pollutants Part-A: Effluents' notified
under Schedule-VI].
40. PESTICIDE
MANUFACTURING
AND FORMULATION
INDUSTRY.
EFFLUENTS
1. Temperature Shall not exceed 5
o
C above
the receiving water
temperature
2. pH 6.5 – 8.5
3. Oil and Grease 10
4. BOD
1
[(3 days at 27
o
C)] 30
5. Total Suspended Solids 100
6. Bio-assay test 90% survival of fish after 96
hours in 100% effluent.
7. (a) Specific Pesticides :
Benzenl Hexachloride 10
Carbonyl 10
DDT 10
Endosulfan 10
Diamethoate 450
Fenitrothion 10
Malathion 10
1
Substituted by Rule 2 of the Environment (Protection) Amendment Rules, 1996 notified by G.S.R.176(E), dated
2.4.1996 may be read as BOD (3 days at 27oC) wherever BOD 5 days 20oC occurred.
The Environment (Protection) Rules, 1986 435
Sr.
No.
Industry Parameter Standards
1 2 3 4
Phorate 10
Methyl Parathion 10
Phenathoate 10
Pyrethrums 10
Copper Oxyghloride 9600
Copper Sulphate 50
Ziram 1000
Sulphur 30
Paraquat 2300
Proponil 7300
Nitrogen 780
(b) Heavy Metals
Copper 1.00
Managanese 1.00
Zinc 1.00
Mercury 0.01
Tin 0.10
Any other metal like Nickel
etc.
Shall not exceed 5 times the
drinking water standards of
BIS.
(c) Organics
Phenol and Phenolic
compounds as C6H5OH
1.0
(d) Inorganics
Arsenics (As As) 0.2
Cyanide (as CN) 0.2
Nitrate (as NO3) 50.0
Phosphate (as P) 5.0
The Environment (Protection) Rules, 1986 436
Sr.
No.
Industry Parameter Standards
1 2 3 4
1
[EMISSIONS Not to exceed
mg/Nm
3
HCl 20
Cl2 5
H2S 5
P2O5 (as H3PO4) 10
NH3 30
Particulate matter with
pesticides compounds
20
CH3Cl 20
HBr 5]
Note : 1. Limits should be complied with the end of the treatment plant before
any dilution.
2. Bio-assay test should be carried out with available species of fish in
receiving water.
3. State Boards may prescribe limits of total dissolved solids (TDS) sulphates
and chlorides depending on the uses of recipient water body.
4. State Board may prescribe COD limit correlated with BOD limit.
5. Pesticides are known to have metabolites and isomers. If they are found
insignificant concentration, standards may be prescribed for those in the
list by Central or State Board.
6. Industries are required to analyse pesticides in waste water by
advanced analytical method such as GLC/HPLC.
7. All the parameters will be compulsory for formulators, for others, the 7
th
will be optional.
1
Inserted entries relating to emissions by Rule 2(V) of the Environment (Protection) First Amendment Rules,
2006 notified vide G.S.R.46(E), dated 3.2.2006.
The Environment (Protection) Rules, 1986 437
Sr.
No.
Industry Parameter Standards
1 2 3 4
41. TANNERY (AFTER
PRIMARY
TREATMENT)
Disposal : Channel/
conduit
Carrying waste waters to
Secondary Treatment
Plants
Type of Tanners :
EFFLUENT
- chrome tanneries/
combined chrome &
Vegetable tanneries.
pH 6.5 – 9.0
SS Not to exceed 600
Chromium Concentration after
treatment in the chrome waste
water stream
45
- Vegetable tanneries pH 6.5 – 9.0
SS Not to exceed 600
Note : The above standards will apply to those tannery units which have made full
contribution to a Common Effluent Treatment Plant (CETP) Comprising
secondary treatment. Those who have not contributed will be governed by earlier
Notification No. S.O.
*
61 (E), dated January 18, 1988.
42. PAINT INDUSTRY
WASTE WATER
DISCHARGE
EFFLUENTS
pH 6.0 – 8.5
Suspended Solids 100
BOD5
1
[(3 days at 27
o
C)] 50
Phenolics as C6H5OH 1.0
Oil and Grease 10.0
Bio-assay test 90% survival in 96 hours
Lead as Pb 0.1
*
Corrected as per Notification No. S.O. 8(E) dated 31.12.1990.
1
Substituted by Rule 2 of the Environment (Protection) Amendment Rules, 1996 notified by G.S.R.176(E), dated
2.4.1996 may be read as BOD (3 days at 27oC) wherever BOD 5 days 20oC occurred
The Environment (Protection) Rules, 1986 438
Sr.
No.
Industry Parameter Standards
1 2 3 4
Chromium as Cr Hexavalent 0.1
Total 2.0
Copper as Cu 2.0
Nickle as Ni 2.0
Zinc as Zn 5.0
Total heavy metals 7.0
43. INORGANIC
CHEMICAL
INDUSTRY (WASTE
WATER
DISCHARGE)
EFFLUENTS
part I (metal compounds
of Chromium,
Manganese, Nickel,
Copper, Zinc, Cadmium,
Lead and Mercury)
pH 6.0 – 8.5
Chromium as Cr Hexavalent 0.1
Total 2.0
Manganese as Mn 2.0
Nickel as Ni 2.0
Copper as Cu 2.0
Zinc as Zn 5.0
Cadmium as Cd 0.2
Lead as Pb 0.1
Mercury as Hg .01
Cynide as CN 0.2
Oil & Grease 10.0
Suspended Solids 30.0
In addition to the above, total
heavy metals are to be limited to
7 mg/l.
The Environment (Protection) Rules, 1986 439
Sr.
No.
Industry Parameter Standards
1 2 3 4
44. BULLION REFINING
(WASTE WATER
DISCHARGE)
EFFLUENTS
pH 6.5 – 8.5
Cynide as CN 0.2
Sulphide as S 0.2
Nitrate as N 10.0
Free C12 as C1 1.0
Zinc as Zn 5.0
Copper as Cu 2.0
Nickel as Ni 2.0
Arsenic as As 0.1
Cadmium as Cd 0.2
Oil and Grease 10.0
Suspended Solids 100
*
45. DYE & DYE
INTERMEDIATE
INDUSTRY (WASTE
WATER
DISCHARGE)
EFFLUENTS
pH 6.0 – 8.5
Colour Hazen Unit 400.0
Suspended Solids 100.0
BOD
1
[(3 days at 27
o
C)] 100.0
Oil and Grease 10.0
Phenolics as C6H5OH 1.00
Cadmium as Cd 0.2
Copper as Cu 2.0
Manganese as Mn 2.0
Lead as Pb 0.1
Mercury as Hg 0.01
Nickel as Ni 2.0
Zinc as Zn 5.0
Chromium as Cr
6+
0.1
Total Chromium 2.0
Bio-assay test 90% survival in 96 hours.
*
Standards Notified as Sl. No. 8 may also be referred.
1
Substituted by Rule2 of the Environment (Protection) Amendment Rules, 1996 notified by G.S.R.176(E), dated
2.4.1996 may be read as BOD (3 days at 27oC) wherever BOD 5 days 20oC occurred
The Environment (Protection) Rules, 1986 440
Sl.No. Category Standards
dB(A)
1 2 3
46. NOISE LIMITS FOR AUTOMOBILES (FREE FIELD) AT ONE
METER IN dB(A) AT THE MANUFACTURING STAGE TO BE
ACHIEVED BY THE YEAR 1992.
(a) Motorcycle, Scooters & Three wheelers 80
(b) Passenger Cars 82
(c) Passenger or Commercial Vehicles upto 4 MT 85
(d) Passenger or Commercial Vehicles above 4 MT and upto 12 MT 89
(e) Passenger or Commercial Vehicles exceeding 12 MT 91
47. DOMESTIC APPLIANCES AND CONSTRUCTION EQUIPMENTS
AT THE MANUFACTURING STAGE TO BE ACHIEVED BY THE
YEAR, 1993
(a) Window Air Conditioner of 1 ton to 1.5 tons 68
(b) Air Coolers 60
(c) Refrigerators 46
1
[(d) ***……… - ]
(e) Compactors (rollers) Front loaders, Concrete mixers, Cranes
(movable), Vibrators and Saws.
75
1
The words and figures ‗Diesel generators for domestic purposes … 85-90‘ omitted by Rule 2(a) of the
Environment (Protection) Second Amendments Rules, 2002 published vide Notification No.G.S.R.371(E),
dated 17.5.2005
The Environment (Protection) Rules, 1986 441
Sr.
No.
Industry Parameter Standards
1 2 3 4
1
48. GLASS INDUSTRY EMISSIONS
A. Sodalime & Borosilicate
and other special Glass
(other than Lead)
(a) Furnace : Capacity
(i) Upto a product draw
capacity of 60 MT/Day
Particulate Matter 2.0 kg/hr.
(ii) Product draw capacity
more than 6 MT/Day
Particulate Matter 0.8 kg/MT of product
drawn
(iii) For all capacities Stack height H=14(Q)
0.3
where Q
is the emission rate of
SO2 in Kg/hr. & H is
Stack height in
meters.
Total Fluorides 5.0 mg/NM
3
Nox Use of low Nox
burners in new plants
(b) Implementation of the following measures for fugitive emission control from other
sections :
(i) Raw materials should be transported in leak proof containers.
(ii) Cullet preparation should be dustfree using water spraying.
(iii) Batch preparation section should be covered.
B. Lead Glass
(a) Furnaces :
All capacities Particulate Matter 50 mg/NM
3
Lead 20 mg/NM
3
(b) Implementation of the following measures for fugitive emission control from other
sections:
(i) Batch mixing, proportioning section and transfer points should be covered and it
should be connected to control equipments to meet the following standards :
Particulate matter 50 mg/NM
3
Lead 20 mg/NM
3
(ii) Minimum Stack height should be 30 metres in lead glass units.
(c) Pot furnace at Firozabad
Furnace :
Particulate matter 1200 mg/NM
3
Note : Depending upon local environmental conditions, State/Central Pollution Control Board can
prescribe more stringent standards than those prescribed above.
1
S.No. 48 to 55 and entries relating thereto inserted vide GSR 93(E) dt. 21.2.91 published in the Gazette No. 79
dated 27.2.91.
The Environment (Protection) Rules, 1986 442
Sr.
No.
Industry Parameter Standards
1 2 3 4
Glass Industries (for all
categories)
EFFLUENTS:
pH 6.5 – 8.5
Total Suspended Solids 100 mg/l
Oil & Grease 10 mg/l
49. LIME KILN Stack Height
Capacity :
Upto 5 T/day Stack Height A hood should be provided
with a stack of 30 meter
height from ground level
(including kiln height).
Above 5T/day Stack height H=14(Q)
0.3
where Q is
emission rate of SO2 in
kg/hr and H=Stack Height
in meters.
More than 5T/day and up to 40
T/Day
Particulate matter 500 mg/Nm
3
Above 40T/day Particulate matter 150 mg/Nm
3
50.
SLAUGHTER HOUSE,
MEAT & SEA FOOD
INDUSTRY
EFFLUENTS Concentration in mg/l
Category
A.Slaughter House
(a) Above 70 TLWK/day BOD
1
[3 days at 27
o
C] 100
Suspended Solids 100
Oil and Grease 10
(b) 70 TLWK/day below BOD
1
[3 days at 27
o
C] 500
B.Meat Processing
(a) Frozen Meat BOD
1
[3 days at 27
o
C] 30
Suspended Solids 50
Oil & Grease 10
(b) Raw Meat from own
Slaughter House.
BOD
1
[3 days at 27
o
C] 30
Suspended Solids 50
Oil & Grease 10
(c) Raw Meat from other
sources
Disposal via Screen and
Septic Tank.
C.Sea Food Industry BOD
1
[3 days at 27
o
C] 30
Suspended Solids 50
Oil and Grease 10
The emission standards from Boiler House shall conform to the standards already prescribed under E(P) Act,
1986 vide notification No.G.S.R.742(E), dated 30.8.90.
1
Substituted by Rule 2 of the Environment (Protection) Amendment Rules, 1996 notified by G.S.R.176(E), dated
2.4.1996 may be read as BOD (3 days at 27oC) wherever BOD 5 days 20oC occurred.
The Environment (Protection) Rules, 1986 443
Sr.
No.
Industry Parameter Standards
1 2 3 4
Note : (i) TLWK – Tonnes of Live Weight Killed (ii) In case of disposal into municipal sewer
where sewage is treated the industries shall install screen and oil & grease separation units.
(iii) The industries having slaughter house along with meat processing units will be
considered in meat processing category as far as standards are concerned.
51. FOOD AND FRUIT
PROCESSING INDUSTRY:
EFFLUENTS Concentration
not to exceed –
mg/l except pH
Quantum
gm/MT of
product
Category
A. Soft Drinks
(a) Fruit based/ Synthetic
(more than 0.4 MT/Day)
bottles and tetrapack
pH 6.5 – 8.5 -
Suspended Solids 100
Oil and Grease 10
BOD
1
[3days at
27
o
C]
30
(b) Synthetic (less than 0.4
MT/Day)
Disposal via
septic Tank
-
B. Fruit & Vegetables
(a) Above 0.4 MT/Day pH 6.5 – 8.5 -
Suspended Solids 50
Oil and Grease 10
BOD
1
[3days at 27
o
C] 30
(b) 0.1-0.4 MT/day (10
MT/year)
Disposal via
septic Tank
-
C. Bakery
(a) Bread and Bread &
Biscuit
(i) Continuous process
(More than 20T/day)
pH 6.5 - 8.5 -
BOD
1
[3days at 27
o
C] 200 25
1
Substituted by Rule 2 of the Environment (Protection) Amendment Rules, 1996 notified by G.S.R.176(E), dated
2.4.1996 may be read as BOD (3 days at 27oC) wherever BOD 5 days 20oC occurred.
The Environment (Protection) Rules, 1986 444
Sr.
No.
Industry Parameter Standards
1 2 3 4
(ii) Non-continuous
process (less than 20
MT/day)
- Disposal via
Septic tank
(b) Biscuit Production
(i) 10 T/day & above
pH 6.5 – 8.5
BOD
1
[3days at27
o
C] 300 35
D. Confectioneries EFFLUENTS
(a) 4 T/day and above pH 6.5 – 8.5 -
Suspended Solids 50
Oil and Grease 10
BOD
1
[3days at
27
o
C]
30
(b) Below 4 T/day Disposal via
Septic Tank
Note : To ascertain the category of ‗unit fails‘ the average of daily production and waste
water discharge for the preceding 30 operating days from the date of sampling
shall be considered.
* The emission from the boiler house shall conform to the standards already
prescribed under E(P) Act, 1986 vide Notification No. GSR 742(E) dated
30.8.90.
52. *JUTE PROCESSING
INDUSTRY :
EFFLUENTS Concentration in mg/l
except pH and Water
consumption
pH 5.5 – 9.0
BOD
1
[3days at 27
o
C] 30
Suspended Solids 100
Oil and Grease 10
Water Consumption 1.60 Cum/Ton of product
produced.
1
Substituted by Rule 2 of the Environment (Protection) Amendment Rules, 1996 notified by G.S.R.176(E), dated
2.4.1996 may be read as BOD (3 days at 27oC) wherever BOD 5 days 20oC occurred.
The Environment (Protection) Rules, 1986 445
Sr.
No.
Industry Parameter Standards
1 2 3 4
Note : 1. Water Consumption for the Jute processing industry will be 1.5 Cum/Ton of
product from January, 1992.
2. At the present no limit for colour is given for liquid effluent. However, as
far as possible colour should be removed.
* Stack emissions from boiler house shall conform to the standards already
prescribed under Environment (Protection) Act, 1986, vide Notification No.
GSR 742(E), dated 30.08.90.
53. LARGE PULP & PAPER
NEWS PRINT/ RAYON
GRADE PLANTS OF
1
[CAPACITY ABOVE 24000
MT PER ANNUM]
EFFLUENTS Concentration in mg/l
except pH and TOCL
pH 7.0 – 8.5
BOD
2
[3 days at 27
o
C] 30
COD 350
Suspended Solids 500
3
[Absorbable Organic
Halogens (AOX) in
effluent discharge
1.5 kg/ton of product with
effect from the date of
publication of this
notification.1.0 kg/ton of
product with effect from
the 1
st
day of March,2008.]
Flow (Total Waste
Water Discharge)
**
(i)Large Pulp & Paper 200 Cum/Ton of Paper
produced
(ii)Large Rayon Grade
Newsprint
150 Cum/Ton of Paper
produced.
54. SMALL PULP AND PAPER EFFLUENT
Paper Plant of Capacity
upto 24000 MT/Annum :
Category :
A. *Agrobased Total waste water
discharge
200 cum/Ton of paper
produced
B. **Waste paper based Total waste water
discharge
75 cum/Ton of paper
produced
1
Substituted by Rule 2(ii) (a) of the Environment (Protection) Third Amendments Rules, 2005 notified vide
Notification No.G.S.R.546(E), dated 30.8.2005.
2
Substituted by Rule 2 of the Environment (Protection) Amendment Rules, 1996 notified by G.S.R.176(E), dated
2.4.1996 may be read as BOD (3 days at 27oC) wherever BOD 5 days 20oC occurred
3
Substituted by Rule 2(ii) (b) of the Environment (Protection) Third Amendments Rules, 2005 notified vide
Notification No.G.S.R.546(E), dated 30.8.2005
**
The Standards with respect of total wastewater discharge for the large pulp and paper mills be established from
1992, will meet the standards of 100 cum/Ton of paper produced.
The Environment (Protection) Rules, 1986 446
Sr.
No.
Industry Parameter Standards
1 2 3 4
* The agro based mills to be established from January, 1992 will meet the standards
of 150 cum/Ton of paper produced.
** The waste-paper mills to be established from January, 1992 will meet the
standards of 50 cum/Tom of paper produced.
55. COMMON EFFLUENT
TREATMENT PLANTS:
EFFLUENTS
(Inlet effluent quality for
CETP)
(Concentration in mg/l)
A. Primary Treatment pH 5.5 – 9.0
Temperature
o
C 45
Oil & Grease 20
Phenolic Compounds (as
C6H5OH)
5.0
Ammonical Nitrogen
(as N)
50
Cynide (as CN) 2.0
Chromium hexavalent (as
Cr+6)
2.0
Chromium (total)(as Cr) 2.0
Copper (as Cu) 3.0
Lead (as Pb) 1.0
Nickel (as Ni) 3.0
Zinc (as Zn) 15
Arsenic (as As) 0.2
Mercury (as Hg) 0.01
Cadmium (as Cd) 1.0
Selenium (as Se) 0.05
Fluoride (as F) 15
Boron (as B) 2.0
Radioactive Materials
Alpha emitters, Hc/ml 10-7
Beta emitters, He/ml 10-8
The Environment (Protection) Rules, 1986 447
Sr.
No.
Industry Parameter Standards
1 2 3 4
Note : 1. These Standards apply to the small scale industries, i.e. total discharge upto
25 KL/Day.
2. For each CETP and its constituent units, the State Board will prescribe
standards as per the local needs and conditions; these can be more stringent
than those prescribed above. However, in case of clusters of units, the State
Board with the concurrence of CPCB in writing, may prescribe suitable
limits.
B. Treated Effluent Quality of Common Effluent Treatment Plant Concentration in
mg/l except pH & Temperature
Into inland
surface waters
On land for
Irrigation
Into Marine
Coastal areas
(a) (b) (c)
pH 5.5 - 9.0 5.5 – 9.0 5.5 – 9.0
BOD
1
[3days at 27
o
C] 30 100 100
Oil & Grease 10 10 20
Temperature Shall not
exceed 40
o
C in
any section of
the stream
within 15
metres down
stream from the
effluent outlet
- 45
o
C at the
point of
discharge.
Suspended Solids 100 200 (a) For
process waste
water – 100
(b) For
cooling water
effluents 10
percent above
total suspended
matter of
effluent cooling
water
Dissolved Solids
(inorganic)
2100 2100 -
1
Substituted by Rule 2 of the Environment (Protection) Amendment Rules, 1996 notified by G.S.R.176(E), dated
2.4.1996 may be read as BOD (3 days at 27oC) wherever BOD 5 days 20oC occurred.
The Environment (Protection) Rules, 1986 448
Sr.
No.
Industry Parameter Standards
1 2 3 4
Total residual chlorine 1.0 - 1.0
Ammonical nitrogen(as
N)
50 - 50
Kjeldahl nitrogen
(asN)
100 - 100
Chemical Oxygen
Demand
250 - 250
Arsenic (as As) 0.2 0.2 0.2
Mercury (as Hg) 0.01 - 0.01
Lead (as Pb) 0.1 - 1.0
Cadmium (as Cd) 1.0 - 2.0
Total Chromium (asCr) 2.0 - 2.0
Copper (as Cu) 3.0 - 3.0
Zinc (as Zn) 5.0 - 15
Selenium (as Se) 0.05 - 0.05
Nickel (as Ni) 3.0 - 5.0
Boron (as B) 2.0 2.0 -
Percent Sodium - 60 -
Cynide (as CN) 0.2 0.2 0.2
Chloride (as Cl) 1000 600 -
Fluoride (as F) 2.0 - 15
Sulphate (as SO4) 1000 1000 -
Sulphide (as S) 2.8 - 5.0
Pesticides Absent Absent Absent
Phenolic compounds
(as C6H5OH)
1.0 - 5.0
Note :All efforts should be made to remove colour and unpleasant odour as far as possible.
The Environment (Protection) Rules, 1986 449
Sr.
No.
Industry Parameter Standards
1 2 3 4
1
56. DAIRY EFFLUENTS Concentration in
mg/l except pH
Quantum per
product processed
pH 6.5 – 8.5 -
*BOD
2
[3 days at 27
o
C] 100 -
** Suspended Solids 150 -
Oil and Grease 10 -
Waste Water generation - 3m
3
/Kl of milk
Note :*BOD may be made stringent upto 30 mg/l if the recipient fresh water body is a
source for drinking water supply. BOD shall be upto 350 mg/l for the chilling plant
effluent for applying on land provided the land is designed and operated as a
secondary treatment system with suitable monitoring facilities. The drainage water
from the land after secondary treatment has to satisfy a limit of 30 mg/l of BOD and
10 mg/l of nitrate expressed as ‗N‘. The net addition to the groundwater quality
should not be more than 3 mg/l of BOD and 3 mg/l of nitrate expressed as ‗N‘. This
limit for applying on land is allowed subject to the availability of adequate land for
discharge under the control of industry, BOD value is relaxable upto 350 mg/l,
provided the wastewater is discharged into a town sewer leading to secondary
treatment of the sewage.
** Suspended solids limit is relaxable upto 450 mg/l, provided the wastewater is
discharged into town sewer leading to secondary treatment of the sewage.
57. TANNERIES EFFLUENTS Concentration in
mg/l except pH
Quantum per raw
hide processed
pH 6.5 – 9.0 -
*BOD
2
[3 days at 27
o
C] 100 -
Suspended Solids 100 -
Sulphides (as S) 1 -
Tototal Chromium (as Cr) 2
Oil and Grease 10 -
Waste Water generation - 28 m
3
/T
* For effluent discharge into inland surface waters BOD limit shall be made stricter to 30
mg/l by the concerned State Pollution Control Board.
1
Sl. No. 56 to 61 and entries relating thereto inserted vide GSR 475(E) dated 5.5.92 published in the Gazette
No. 202 dated. 5.5.92.
2
Substituted by Rule 2 of the Environment (Protection) Amendment Rules, 1996 notified by G.S.R.176(E), dated
2.4.1996 may be read as BOD (3 days at 27oC) wherever BOD 5 days 20oC occurred.
The Environment (Protection) Rules, 1986 450
Sr.
No.
Industry Parameter Standards
1 2 3 4
****58. NATURAL
RUBBER
PROCESSING
INDUSTRY
Centrifuging and creaming units
Crape and crumb units
for disposal
into inland
surface water
for disposal
on land for
irrigation
for disposal into
inland surface
water
for disposal
on land for
irrigation
(a) (b) (a) (b)
(Concentration in mg/l, except
pH & quantum of waste water
generation)
(Concentration in mg/l except
pH & quantum of waste waster
generation)
pH 6 – 9 6 – 8 6 – 8 6 – 8
Total Kjeldahl
nitrogen (as N)
200(100*) *** 50 ***
Ammonical
Nitrogen as (N))
100 (50*) ***` 25 ***
BOD
1
[3 days at
27
o
C]
20
o
C 100 30 100
COD 250 *** 250 ***
Oil & Grease 10 20 10 20
Sulphide (as S) 2 *** 2 ***
TDS 2100 NP** 2100 NP**
SS 100 200 100 20
Quantum of waste
water generation
5 lit/kg of
product
processed
8 lit./kg of
product
processed
40 lit/kg of
product
processed
40 lit./kg of
product
processed
* To be achieved in three years.
** Not prescribed in case effluent is used for rubber plantation of their own. In other
cases suitable limit, as necessary may be prescribed by the State Board.
*** Not specified.
**** These standards supersede the standards notified as serial no. 26 vide Notification
No. S.O. 8(E), dated 3
rd
June, 1989.
59. BAGASSE-FIRED BOILERS EMISSIONS (Concentration in mg/l)
(a) Step Grate Particulate Matter 250
(b) Horse shoe/pulsating grate Particulate Matter 500 (12% CO2)
(c) Spreader Stroker Particulate Matter 800 (12% CO2)
Note : In the case of horse shoe and spreader stroker boilers, if more than one boiler is
attached to a single stack, the Standard shall be fixed based on added capacity of
all the boilers connected with the stack.
1
Substituted by Rule 2 of the Environment (Protection) Amendment Rules, 1996 notified by G.S.R.176(E),
dated 2.4.1996 may be read as BOD (3 days at 27oC) wherever BOD 5 days 20oC occurred.
The Environment (Protection) Rules, 1986 451
Sr.
No.
Industry Parameter Standards
1 2 3 4
60. MAN-MADE FIBRE INDUSTRY
(SEMI-SYNTHETIC)
EFFLUENTS (Concentration in mg/l
except for pH)
pH 5.5 - 9.0
Suspended Solids 100
BOD
1
[3 days at 27
o
C] 30
Zinc (as Zn) 1
61 CERAMIC INDUSTRY EMISSIONS (Concentration in
mg/Nm
3
)
A. Kilns
(a) Tunnel, Top Hat,
Chamber
Particulate Matter 150
Fluoride 10
Chloride 100
Sulphur dioxide **
(b) Down-draft Particulate Matter 1200
Fluoride 10
Chloride 100
Sulphur dioxide **
(c) Shuttle Particulate Matter 150
Fluoride 10
Chloride 100
Sulphur dioxide **
(d) Vertical Shaft Kiln Particulate Matter 250
Fluoride 10
Sulphur dioxide **
(e) Tank furnace Particulate Matter 150
Fluoride 10
Sulphur dioxide **
B. Raw material handling,
Processing and operations
(a) Dry raw materials
handling and processing
operations
Particulate Matter 150
(b) Basic raw material and
processing operations
Particulate Matter *
(c) Other sources of air
pollution Generation
Particulate Matter *
C. Automatic Spray Unit
(a)Dryers
(i)Fuel fired dryers Particulate matter 150
(ii)For heat recovery dryer Particulate matter *
(b)Mechanical finishing
operation
Particulate matter *
(c) Lime/Plasters of Paris
manufacture
Standards notified at Sr. No.2 may also be referred.
1
Substituted by Rule 2 of the Environment (Protection) Amendment Rules, 1996 notified by G.S.R.176(E), dated
2.4.1996 may be read as BOD (3 days at 27oC) wherever BOD 5 days 20oC occurred.
The Environment (Protection) Rules, 1986 452
Sr.
No.
Industry Parameter Standards
1 2 3 4
Capacity :
Upto 5T/day Stack Height A. Hood should be
provided with a stack of
30 meter height from
ground level (including
Kiln height)
Above 5T/day - do - H=14(Q)
0.3
Where Q is
emission rate of SO2 in
kg/hr and H=Stack in
meters
More than 5T/day Particulate matter 500 mg/NM
3
and utp 40 T/day Particulate matter 150 mg/NM
3
Note : Oxygen reference level for particulate matter concentration calculations for kilns
mentioned at A(c) is 18% and for those at A(b), A(d) and A(c) is 8%.
* All possible preventive measures should be taken to control pollution as far as
practicable.
** The standard for sulphur dioxide in terms of stack height limits for kilns with
various capacities of coal consumption shall be as indicated below :
Coal consumed per day Stack height
Less than 8.5 MT 9 m
More than 8.5 to 21 MT 12 m
More than 21 to 42 MT 15 m
More than 42 to 64 MT 18 m
More than 64 to 104 MT 21 m
More than 104 to 105 MT 24 m
More than 105 to 126 MT 27 m
More than 126 MT 30 m or using
formula
H=14 (Qg)
0.3
(whichever is more)
Note : In this notification
H—Physical height of the stack
Qg—Emission of sulphurdioxide in Kg/hr.
MT—Metric tones
m—meters
The Environment (Protection) Rules, 1986 453
S. No. Indsutry Parameter Standards
1. 2. 3. 4.
1[62. VISCOSE
FILAMENT YARN
(Sub-sector of
manmade fibre semi-
Synthetic Industry)
EFFLUENTS (Concentration in mg/l
except for pH)
pH 5.5-9.0
Suspended solids 100
BOD(3 days at
27oC)
30
Zinc (as Zn) 5
2[63. STARCH INDUSTRY EFFLUENTS:
(Maize products) Concentration not to exceed
mg/l (except pH and waste
water discharge)
pH 6.5-8.5
BOD
(3 days at 27oC)
Suspended Solids 150
Wastewater
discharge 8 m3 /tonne of maize
Processed
Note : The prescribed limits for BOD and suspended solids
shall be made more stringent or less stringent
depending upon the conditions and local
requirements as mentioned below :
(i) BOD shall be made stringent upto 30mg/l if
the recipient fresh water body is a source
for drinking water supply.
(ii) BOD shall be allowed upto 350 mg/l for
applying on land provided the land is
designed and operated as a secondary
treatment system with the requisite
monitoring facilities. The drainage water
1
Sl. No. 62 and entries relating thereto inserted by Rule 2(b) of the Environment (Protection) Third Amendment Rules,
1993 by G.S.R. No. 801 (E), dated 31.12.1993.
2
Sl.No.63 to 78 and entries relating thereto inserted by Rule 3 (a) of the Environment (Protection)
(Amendment ) Rules, 1996 notified by G.S.R.176(E), dated 2.4.1996.
* Substituted by Rule 2 of the Environment (Protection) Amendment Rules, 1996 notified by G.S.R.176(E), dated
2.4.1996 may be read as BOD (3 days at 27oC) wherever BOD 5 days 20oC occurred.
The Environment (Protection) Rules, 1986 454
from the land after secondary treatment has
to satisfy a limit of 30mg/l of BOD and
10mg/l of nitrate expressed as ―N‖. The net
addition to ground water quality should not
be more than 3 mg/l of BOD and 10mg/l of
nitrate expressed as ―N‖.
(iii) BOD shall be allowed upto 350 mg/l for
discharge into a town sewer, if such sewer
leads to a secondary biological treatment
system.
(iv) Suspended solids shall be allowed upto 450
mg/l for discharge into a town sewer, if such
sewer leads to a secondary biological
treatment system.
(v) In the event of bulking of sludge, the
industry shall immediately apprise the
respective State Pollution Control Board.
64. BEEHIVE HARD EMISSION :
COKE OVEN
(i) New unit Particulate matter 150 mg/Nm3
(corrected to 6% CO2)
Hydrocarbons 25 ppm
(ii) Existing units Particulate matter 350 mg/Nm3
(corrected to 6% CO2)
Note : For control of emissions and proper dispensation of
pollutants the following guidelines shall be followed:
(i) Units set up after the publication of this
notification shall be treated as new units.
(ii) A minimum stack height of 20 meters shall
be provide by each unit.
(iii) Emissions from coke ovens shall be
channelised through a tunnel and finally
omitted through a stack. Damper
adjustment techniques shall be used to
have optimum heat utilization and also to
control the emission of unburnt carbon
particles and combustible flue gases.
(iv) Wet scrubbing system or waste heat
utilization for power generation or byproduct
recovery systems should be installed
preferably to achieve the prescribed
standards.
The Environment (Protection) Rules, 1986 455
(v) After four years from the date of this
notification, all the existing units shall
comply with the standards prescribed for
the new units.
65. BRIQUETTE INDUSTRY EMISSIONS :
(COAL)
(i) Units having capacity Particulate matter 350 mg/Nm3
less than 10 tonnes (corrected to 6% CO2)
(ii) Units having capacity Particulate matter 150 mg/Nm3
10 tonnes or more (corrected to 6% CO2)
Note: For control of emissions/and proper dispersal of
pollutants, the following guidelines shall be followed
by the industry :-
(i) A minimum stack height of 20 metres shall be
provided.
(ii) All ovens shall be modified to single chimney
multi-oven systems.
(iii) Emissions from ovens shall be channelised
through inbuilt draft stack. Optimum heat
utilization technique shall be used.
(iv) In case of units having capacity 10 tonnes
and above, wet scrubbing system shall be
provided to control air pollution.
66. SOFT COKE INDUSTRY Particulate matter 350 mg/Nm3
(Corrected to 6% CO2)
Note: Wet scrubbing systems alongwith byproduct
recovery system shall be provided.
GUIDELINES FOR EMISSION CONTROL TO IMPROVE WORK ZONE
ENVIRONMENT (APPLICABLE FOR INDUSTRIES AT SERIAL NUMBERS 64,
65 AND 66):
(a) Water used for quenching and wet scrubbing
shall be recalculated and reused through catch-
pits.
(b) Leakages in the oven shall be sealed by
bentonite or by any suitable paste and by
proper maintenance to avoid fugitive emission.
The Environment (Protection) Rules, 1986 456
GUIDELINES FOR COAL HANDLING AND CRUSHING PLANT (APPLICABLE
TO INDUSTRIES AT SERIAL NUMBERS 64,65 AND 66)
(a) Unloading of coal trucks shall be carried out
with proper care avoiding dropping of the
materials from height. It is advisable to
moist the material by sprinkling water while
unloading.
(b) Pulverisation of coal shall be carried out in
an enclosed place and water sprinkling
arrangement shall be provided at coal
heaps, crushing area and on land around
the crushing unit.
(c) Work area surrounding the plant shall be
asphalted or concreted.
(d) Green belt shall be developed along the
boundary of the industry.
(e) Open burning of coal to manufacture soft
coke shall be stopped.
67. EDIBLE OIL & VANASPATI INDUSTRY
EFFLUENTS :
Temperature Not more than 5oC above
ambient temperature of the recipient waterbody
pH 6.5—8.5
Suspended solids 150 mg/l
Oil & grease 20 mg/l
BOD(3 days at 27oC) 100 mg/l
COD 200 mg/l
Wastewater Discharge
(i) Solvent extraction 2.0 cum/tonne of product (oil)
(ii) Refinery/Vanaspati 2.0 cum/tonne of product
(refined oil/Vanaspati)
(iii)Integrated unit of 4.0 cum/tonne of refined
extraction & refinery/ Vanaspati product
Vanaspati
(iv)Barometric cooling 15.0 cum/tonne of refined
water/De-odoriser oil/vanaspati
water
The Environment (Protection) Rules, 1986 457
Note :
(i) The above standards shall be applicable to
waste water from processes and cooling.
(ii) BOD shall be made stringent upto 30 mg/l if
the recipient fresh water body is source of
drinking water supply
(iii) The standards for boiler emissions shall be
applicable as prescribed under Schedule I
of these rules.
68. ORGANIC CHEMICALS MANUFACTURING INDUSTRY
EFFLUENTS :
(a) Compulsory parameters pH 6.5—8.5
BOD(3 days at 27oC) 100 mg/l
Oil & Grease 10mg/l
Bioassay test Minimum90% survival
after 96 hours with at
100% effluent
(b) Additional parameters (mg/l)
Nitrate(as N) 10
Arsenic 0.2
Hexavalent Chormium 0.1
Total Chormium 1.0
Lead 0.1
Cyanide as CN 0.2
Zinc 0.5
Mercury 0.01
Copper 2.0
Nickel 2.0
Phenolies as C6H3
OH 5.0
Sulphide 2.0
Note :
(i) No limit for COD is prescribed but it shall be
monitored. If the COD in a treated effluent is
persistently greater than 250 mg/l, such
industrial units are required to identify
chemicals causing the same. In case these
are found to be toxic as defined in Hazardous
The Environment (Protection) Rules, 1986 458
Chemicals Rules,1989 in Part I of Schedule-I,
the State Boards in such cases may direct the
industries to install tertiary treatment system
stipulated time limit. This may be done on
case to case basis.
(ii) These standards are not applicable to small
scale detergent (formulating units).
(iii) The standards for boiler emissions shall be
applicable as per the existing emission
regulations.
(iv) Industry covered under this group are halo-
aliphatics, plasticizers, aromatics (alcohols,
phenols, esters, acids and salts, aldehydes
and ketone), substituted aromatics, aliphatic
(alcohols, esters, acids, aldehydes, ketones,
amines and amides) and detergents.
69. FLOUR MILLS
EFFLUENTS :
pH 6.5—8.5
BOD (3 days at 27oC) 100 mg/l
Total Suspended Solids 100mg/l
Oil & Grease 10mg/l
Waste water discharge 2 cubic metre per
tonne of wheat
processed
Note :
(i) BOD shall be stringent upto 30 mg/l if the
recipient freshwater body is a source for
drinking water supply.
(ii) BOD shall be allowed upto 350 mg/l for
applying on land, provided the land is
designed and operated as a secondary
treatment system with the requisite monitoring
facilities. The drainage water from the land
after secondary treatment has to satisfy a limit
of 30 mg/l of BOD and 10 mg/l of nitrate
expressed as ―N‖. The net addition to ground
water quality should not be more than 3mg/l
of BOD and 10 mg/l of nitrate expressed as
―N‖.
The Environment (Protection) Rules, 1986 459
(iii) BOD shall be allowed upto 350 mg/l for
discharge into a town sewer, if such sewer
leads to a secondary biological treatment
system.
(iv) Suspended solids shall be allowed upto 450
mg/l for discharge into a town sewer, if such
sewer leads to a secondary biological
treatment system.
70. BOILERS(SMALL)
Steam generation capacity Particulate matters emission
(ton/hour) (mg/Nm3)
less than 2 1200*
2 to less than 10 800*
10 to less than 15 600*
15 and above 150**
* to meet the respective standards, cyclone/multicyclone is recommended as
control equipment with the boiler.
** to meet the standard, bag filter/ESP is recommended as control equipment
with the boiler.
Note :
(i) 12% of CO2 correction shall be the
reference value for particulate matter
emission standards for all categories of
boilers.
(ii) These limits shall supercede the earlier
limits notified under Schedule I at serial
number 34 of Environment (Protection) Act,
1986 vide notification GSR 742(E), dated
30th August, 1990.
(iii) Stack Height for small Boilers.
For the small boilers using coal or liquid
fuels, the required stack height with the
boiler shall be calculated by using the
formula.
H=14 Q0.3
Where H—Total stack height in metres from
the ground level.
Q=SO2 emission rate in kg/hr.
The Environment (Protection) Rules, 1986 460
In no case the stack height shall be less
than 11 metres.
Where providing all stacks are not feasible
using above formula the limit of 400
mg/Nm3 for SO2 emission shall be met by
providing necessary control equipment with
a minimum stack height of 11 metres.
71.PESTICIDES INDUSTRY
(i) Compulsory Parameters mg/l except pH
pH 6.5—8.5
BOD (3 days at 27oC) 100
Oil & Grease 10
Suspended solids 100
Bioassay test Minimum 90%
survival of fish
after 96 hours with
90% effluent and
10% dilution water.
Test shall be
carried out as per
IS : 6502-1971.
(ii) Additional Parameters mg/l
(a) Heavy metal
Copper 1.0
Manganese 1.0
Zinc 1.0
Mercury 0.01
Tin 0.1
Any other like Nickel shall not exceed 5
times the drinking
water standards (BIS)
individually.
(b) Organics
Phenol & Phenolic
Compounds as
C6H5OH 1.0
(c) Inorganics
Arsenic as AS 0.2
Cyanide as CN 0.2
Nitrate as NO3 50
Phospate as P 5.0
The Environment (Protection) Rules, 1986 461
(d) Specific pesticide (microgram/litre)
Benzene
Hexachloride 10
DDT 10
Dimethoate 450
Copper oxychloride 9600
Ziram 1000
2,4D 400
Paraquat 23000
Propanil 7300
Nitrofen 780
Other/below mentioned
Pesticides individually 100
Other pesticides :
(i) Insecticides :
Aluminium Phosphide Lindane Phrethrum extract
Dichloroves Malathlon Quinalphos
EDTC Mixer Methyl-Bromide Monocrotophos
Ethylene Dibromide Nicotine Sulphate CarbaryI
Ethion Oxydemeton MethyI Endosulfan
Fenitrothoron MethyI Parathion Fenvalerate
Lime-sulphur Phosphamidon Phorate
Temephos
(ii) Fungicides :
Aureofungin Organomercurials (MEMC & PMA)
Barium Polysulphide Sulphur (Collodal), Wettable & Dust)
Cuprous Oxide Streptocyceline
Ferbam Thiram
Mancozeb Zenib
Manab Carbendazim
Nickel Chloride Tridemoraph
(iii) Rodenticides : (iv) Nematicides : (v) Weedicides
Comafuryl Metham N-Sodium Fluchloralin
Warfarin Isoproturon
Zinc Phosphide Butachlor
Anilphos
(vi) Plant Growth Regulants :
Chloromequat Chloride
Nemphalene Acetic Acid
(vii) Any other pesticide not specified above
The Environment (Protection) Rules, 1986 462
Note :
(1) Limits shall be complied with at the end of the treatment plant before any
dilution.
(2) From the ‗Additional Parameters‘ specified in 71(ii), only the relevant
(based on the raw-materials used and products manufactured) may be
prescribed by the concerned State Board on a case to case basis.
(3) No limit for COD is prescribed. If the COD in a treated effluent is
persistently more than 250 mg/l, such industrial units are required to
identify the chemicals causing the same. In case, there are found to be
toxic as defined in Schedule I of the Hazardous Chemicals Rules,1989,
the State Boards in such cases may direct the industries to install tertiary
treatment, stipulating time limit. This may be done on a case to case
basis.
(4) Solar evaporation followed by incineration is a recognized practice,
provide the guidelines of solar evaporation as given below are followed.
GUIDELINES ON SOLAR EVAPORATION SYSTEM OR WASTEWATER
FROM PESTICIDE INDUSTRY.
(i) Solar evaporation pans shall be constructed in such a way that the
bottom is atleast one metre above the ground level.
(ii) Solar evaporation pans shall be leak proof and of impervious
construction and designed as per IS:7290.
(iii) The solar evaporation pans shall be designed on the basis of
evaporation rate matching to the out put of wastewater.
(iv) Wastewater must be pre-treated as below before subjecting to solar
evaporation :
(a) Oil and grease and floating organics shall be removed so that the
rate of evaporation is not affected.
(b) Acidic/Alkaline waste must be neutralised before solar evaporation
to maintain pH in the range of 6.5 to 8.5.
(c) Toxic volatile matter shall be removed so as not to cause air
pollution.‘
(v) During the rainy season, storm water shall not be allowed to mix with
process waste and enter the pans. The wastewater shall in no case
outflow from the evaporation pans. Alternative arrangements shall be
made to hold the wastewater in proper impervious tanks and if
necessary, force evaporated.
The Environment (Protection) Rules, 1986 463
(vi) In no circumstances, the liquid effluent shall be discharged without
conforming to the minimal national standards or stored in a holding
arrangement which is likely to cause pollution.
(vii) The sludge from the solar evaporation pans shall be incinerated or
disposed as per the guidelines for management and handling of
hazardous waste, published by the Ministry of Environment & Forests,
Government of India, after obtaining authorization from the State
Pollution Control Board under the hazardous Waste (Handling and
Management)Rules,1989.
(viii) The facility shall be protected from flood and storm to prevent
embankments from erosion or any other damage which may render
any portion inoperable.
(ix) Facilities shall be protective enclosure to keep wildlife, domestic
animals, unauthorized persons, etc. away.
72. OIL DRILLING AND GAS EXTRACTION INDUSTRY
A. STANDARDS FOR LIQUID EFFLUENT
1.0 On-Shore facilities(For Marine Disposal)
pH 5.5—9.0
Oil & Grease 10 mg/l
Suspended solids 100 mg/l
BOD(3 days at 27oC) 30 mg/l
Note :
(i) For on-shore discharge of effluents, in addition to
the standards prescribed above, proper marine
outfall has to be provided to achieve the individual
pollutant concentration level in sea water below their
toxicity limits as given below, within a distance of 50
metre from the discharge point, in order to protect
the marine aquatic life :
Parameter Toxicity limit,mg/l
Chromium as Cr 0.1
Copper,as Cu 0.05
Cyanide,as CN 0.005
Fluoride,as F 1.5
Lead, as Pb 0.05
Mercury, as Hg 0.01
Nickel, as Ni 0.1
Zinc, as Zn 0.1
The Environment (Protection) Rules, 1986 464
(ii) Oil and gas drilling and processing facilities, situated on
land and away from saline water sink, may opt either for
disposal of treated water by on-shore disposal of by re-
injection in abandoned well, which is allowed only below
a depth of 1000 metres from the ground level. In case
of re-injection in abandoned well the effluent have to
comply only with respect to suspended solids and oil
and grease 100 mg/l and 10 mg/l, respectively. For on-
shore disposal, the permissible limits are given below.
________________________________________________________________
S.No. Parameter On-shore discharge standards
(Not to exceed)
1. 2. 3.
1. pH 5.5—9.0
2. Temperature 40oC
3. Suspended Solids 100 mg/l
4. Zinc 2 mg/l
5. BOD 30 mg/l
6. COD 100mg/l
7. Chlorides 600 mg/l
8. Sulphates 1000 mg/l
9. TDS 2100 mg/l
10. %Sodium 60 mg/l
11. Oil and Grease 10 mg/l
12. Phenolics 1.2 mg/l
13. Cyanides 0.2 mg/l
14. Fluorides 1.5 mg/l
15. Sulphides 2.0 mg/l
16. Chromium(Cr+6) 0.1 mg/l
17. Chromium (Total) 1.0 mg/l
18. Copper 0.2 mg/l
19. Lead 0.1 mg/l
20. Mercury 0.01 mg/l
21. Nickel 3.0 mg/l
2.0 Off-shore facilities :
For off-shore discharge of effluents, the oil content of the treated effluent
without dilution shall not exceed 40 mg/l for 95% of the observation and shall
never exceed 100 mg/l. Three 8–hourly grab samples are required to be
collected daily and the average value of oil and grease content of the three
samples shall comply with these standards.
The Environment (Protection) Rules, 1986 465
B. GUIDELINES FOR DISCHARGE OF GASEOUS EMISSION :
1.0 DG Sets
1.1 DG Sets at drill site as well as production station shall conform
with the norm notified under the Environment (Protection)
Act,1986.
2.0 Elevated/ground flares
2.1 Cold Venting of gases shall never be resorted to and all the
gaseous emissions are to be flared.
2.2 All flaring shall be done by elevated flares except where there is
any effect on crop production in adjoining areas due to the flaring.
In such cases, one may adopt ground flaring.
2.3 In case of ground flare, to minimize the effects of flaring, the flare
pit at Group Gathering Station(GGS)/Oil Collecting Station(OCS)
and Group Collection Station(GCS) shall be made of RCC
surrounded by a permanent wall (made of refractory brick) of
minimum 5m height, to reduce the radiation and glaring effects in
the adjoining areas.
2.4 A green belt of 100 m width may be developed around the flare
after the refractory wall in case of ground flaring.
2.5 If the ground flaring with provision of green belt is not feasible,
enclosed ground flare system shall be adopted, and be designed
with proper enclosure height, to meet the ground level
concentration(GLC) requirement.
2.6 In case of elevated flaring, the minimum stack height shall be
30m. Height of the stack shall be such that the max. GLC never
exceeds the prescribed ambient air quality limit.
3.0 Burning of effluent in the pits shall not be carried out at any stage.
1[C. GUIDELINES FOR DISPOSAL OF SOLID WASTE, DRILL CUTTING
AND DRILLING FLUIDS FOR OFFSHORE AND ONSHORE DRILLING
OPERATION-
1. Disposal of Drill Cutting and Drilling Fluids for On-shore Installations:
1
Substituted ―paragraph C‖, for ―paragraph C relating to Guidelines For Disposal of Solid Waste‖ by Rule 2(iii) of the
Environment (Protection) Third Amendments Rules, 2005 notified vide Notification No.G.S.R.546(E), dated
30.8.2005.
The Environment (Protection) Rules, 1986 466
(a) Drill Cuttings (DC) originating from on-shore or locations close to
shore line and separated from Water Base Mud (WBM) should be
properly washed and unusable drilling fluids (DF) such as WBM,
Oil Base Mud (OBM), Synthetic Base Mud (SBM) should be
disposed off in a well designed pit lined with impervious liner
located off-site or on-site. The disposal pit should be provided
additionally with leachate collection system.
Design aspects of the impervious waste disposal pit; capping of
disposal pit should be informed by the oil industry to State Pollution
Control Board (SPCB) at the time of obtaining consent.
(b) Use of diesel base mud is prohibited. Only WBM should be used
for on-shore oil drilling operations.
(c) In case of any problem due to geological formation for drilling, low
toxicity OBM having aromatic content< 1% should be used. If the
operators intend to use such OBM to mitigate specific whole
problem/ SBM it should be intimated to Ministry of Environment
and Forests/State Pollution Control Board.
(d) The chemical additives used for the preparation of DF should have
low toxicity i.e. 96 hr LC50 > 30,000 mg/l as per mysid toxicity or
toxicity test conducted on locally available sensitive sea species.
The chemicals used (mainly organic constituents) should be
biodegradable.
(e) DC separated from OBM after washing should have oil content at <
10 gm/kg for disposal into disposal pit.
(f) The waste pit after it is filled up shall be covered with impervious
liner, over which, a thick layer of native soil with proper top slope is
provided.
(g) Low toxicity OBM should be made available at installation during
drilling operation.
(h) Drilling wastewater including DC wash water should be collected in
the disposal pit evaporated or treated and should comply with the
notified standards for on-shore disposal.
(i) Barite used in preparation of DF shall not contain Hg> 1 mg/kg &
Cd> 3mg/kg.
The Environment (Protection) Rules, 1986 467
(j) Total material acquired for preparation of drill site must be restored
after completion of drilling operation leaving no waste material at
site. SPCB should be informed about the restoration work.
(k) In case, environmentally acceptable methods for disposal of drill
waste such as (a) injection to a formation through casing annuals,
if conditions allow (b) land farming at suitable location (c) bio-
remediation (d) incineration or (e) solidification can be considered,
in such cases oil industry is required to submit proposal to Ministry
of Environment and Forests/State Pollution Control Board
(MoEF/SPCB) for approval.
2. Disposal of Drill Cutting and Drilling Fluids for Off-shore
Installations:
(a) Use of diesel base mud is prohibited. Only WBM is permitted for
offshore drilling. If the operator intend to use low toxicity OBM or
SBM to mitigate specific hole problems in the formation, it should
be intimated to MoEF/SPCB. The low toxicity OBM should have
aromatic content< 1%.
(b) The toxicity of chemical additives used in the DF (WBM or OBM or
SBM) should be biodegradable (mainly organic constituents) and
should have toxicity of 96 hr LC 50 Value > 30,000 mg /l as per
mysid toxicity or toxicity test conducted on locally available
sensitive sea species.
(c) Hexavalent chromium compound should not be used in DF.
Alternative chemical in place of chrome lignosulfonate should be
used in DF. In case, chrome compound is used, the DF/ DC
should not be disposed offshore.
(d) Bulk discharge of DF in offshore is prohibited except in emergency
situations.
(e) WBM/OBM /SBM should be recycled to a maximum extent.
Unusable portion of OBM should not be discharged into sea and
shall be brought to on-shore for treatment & disposal in an
impervious waste disposal pit.
(f) Thoroughly washed DC separated from WBM/SBM & unusable
portion of WBM/SBM having toxicity of 96 hr LC50 > 30,000 mg/l
shall be discharged off-shore into sea intermittently, at an average
rate of 50 bbl/hr/well from a platform so as to have proper dilution
& dispersion without any adverse impact on marine environment.
The Environment (Protection) Rules, 1986 468
(g) Drill cutting of any composition should not be discharged in
sensitive areas notified by the Ministry of Environment and Forests.
(h) In case of specific hole problem, use of OBM will be restricted with
zero discharge of DC. Zero discharge would include re-injection of
the DC into a suitable formation or to bring to shore for proper
disposal. In such a case, use of OBM for re-injection should be
recorded and made available to the regulatory agency. Such low
toxic OBM having aromatic content < 1% should be made available
at the installation.
(i) In case, DC is associated with high oil content from hydrocarbon
bearing formation, then disposal of DC should not have oil content
> 10 gm/kg.
(j) The DC wash water should be treated to confirm limits notified
under EPA, before disposal into Sea. The treated effluent should
be monitored regularly.
(k) Discharge of DC from the installation located within 5 km away
from shore should ensure that there is no adverse impact on
marine Eco-system and on the shore. If, adverse impact is
observed, then the industries have to bring the DC on-shore for
disposal in an impervious waste disposal pit.
(l) If any, environmental friendly technology emerges for substitution
of DF and disposal technology, it may be brought to the notice of
MoEF and regulatory agencies. If the operator desires to adopt
such environment friendly technology a prior approval from Ministry
of Environment and Forests is required.
(m) Barite used in preparation of DF shall not contain Hg> 1 mg/kg &
Cd> 3 mg/kg.
(n) Oil drilling operators are required to record daily discharge of DC
& DF to offshore and also to monitor daily the effluent quality, and
submit the compliance report once in every six-month to Ministry of
Environment and Forests.]
The Environment (Protection) Rules, 1986 469
73. 1[PHARMACEUTICAL (MANUFACTURING AND FORMULATION)
INDUSTRY]
S.
No.
Industry Parameter Standards
1 2 3 4
2
[Effluent Standards
i. Compulsory Paramters
Limiting concentration in
mg/l, expect for pH
pH 6.0-8.5
Oil & grease 10
BOD (3 days 27
o
C) 100*
Total suspended Solids 100
Bioassay test 90% survival of fish after
first 96 hours in 100%
effluent **
ii. Additional Paramters
Mercury 0.01
Arsenic 0.20
Chromium (Cr
6+
) 0.10
Lead 0.10
Cyanide 0.10
Phenolics (C6H5OH) 1.0
Sulphides (as S) 2.0
Phosphate (as P) 5.0
Note:
* The BOD and COD limits shall be 30mg/l and 250
mg/l respectively, if treated effluent is discharged
directly into a fresh water body i.e., stream, canal,
river or lake.
** The Bioassay Test shall be conducted as per
IS:6582-1971.
(i) Parameters listed as ‗Additional
Parameters‘ shall be prescribed depending
upon the process and product.
(ii) Limits for total dissolved solids in effluent
shall be prescribed by the concerned
pollution control board/pollution control
committee depending upon the recipient
water body].
1
Substituted by Rule 2(b)(i) of the Environment (Protection) Third Amendment Rules, 2009 notified by G.S.R.512(E),
dated 9.7.2009
2
Substituted by Rule 2(b)(ii) of the Environment (Protection) Third Amendment Rules, 2009 notified by G.S.R.512(E),
dated 9.7.2009
The Environment (Protection) Rules, 1986 470
1
[A. Emission from Incinerator
Limiting
concentration
in mg/Nm3,
unless stated
Sampling
duration in
(minutes)
unless stated
Particulate Matter 50 30 or more
(for sampling
about 300 litre
emission)
HCI 50 30
SO2 200 30
CO 100 Daily average
Total Organic Carbon 20 30
Total
Dioxins
and
Furans *
Existing
Incinerator
0.2
ngTEQ/Nm
3
8 hours
New
Incinerator
0.1
ngTEQ/Nm
3
8 hours
Sb+As+Pb+Cr+Co+Cu+
Mn+ Ni+V+Cd+Th+Hg
and their compounds
1.5 2 hours
* The existing plant shall comply with norms for-
dioxins and furans-as 0.1 ng/TEQ/Nrn
3
within 5
years from the date of notification.
Notes:
i. All monitored values shall be corrected to 11 %
oxygen on dry basis.
ii. The CO2 concentration In tail gas shall not be
less than 7%,.
iii. In case, halogenated organic waste is less than
1% by weight in input waste, all the facilities in
twin chamber incinerator shall be designed so as
to achieve a minimum temperature of 850+25
O
C
in primary chamber and 950°C in secondary
combustion chamber and with a gas residence
time in secondary combustion chamber not less
than 2 (two) seconds,
or
all the facilities in single chamber incinerator for
gaseous hazardous waste shall be designed so as
to achieve a minimum temperature of 950°C in
the combustion chamber with a gas residence
time not less than 2 (two) seconds.
1
Inserted by Rule 2 of the Environment (Protection) Second Amendment Rules, 2009 notified by G.S.R.149 (E),
dated 4.3.2009.
The Environment (Protection) Rules, 1986 471
iv. In case halogenated organic waste is more than
l% by weight in input waste, waste shall be
incinerated only in twin chamber incinerators
and all the facilities shall be designed to achieve
a minimum temperature of 850+25°C in primary
chamber and 1100
o
C in secondary combustion
chamber with a gas residence time in secondary
combustion chamber not less than 2 (two
seconds).
v. Scrubber meant for scrubbing emissions shall
not be used as quencher.
vi. Incineration plants shall be operated
(combustion chambers) with such temperature,
retention time and turbulence, as to achieve
Total Organic Carbon (TOC) content in the
incineration ash and residue less than 3%, and
their loss on ignition is less than 5% of the dry
weight. In case of non-conformity, ash and/or
residue shall be re-incinerated.
vii. The incinerator shall have a chimney of atleast
thirty metre height.
B. Effluent from Incinerator
i. Effluent from scrubber(s) and floor washing
shall flow through closed conduit/pipe network.
ii. Storm water shall not be allowed to mix with
scrubber water and/or floor washings.
iii. Storm water shall be channelized through
separate drains passing through a HDPE lined
pit having holding capacity of 10 minutes
(hourly average) of rainfall.
iv. The built up in Total Dissolved Solids (TDS) in
wastewater of floor washings shall not exceed
1000 mg/l over and above the TDS of raw water
used.
v. Effluent shall not be stored in holding tank(s) in
such manner which may cause pollution to
groundwater.
The Environment (Protection) Rules, 1986 472
vi. Effluent (scrubber water and floor washings)
shall be discharged into receiving water
conforming to the norms prescribed under
Schedule VI:
General Standards for Discharge of Environment
Pollutions (Part A: Effluents) notified under the
Environment (Protection) Rules, 1986].
1
[74 BRICK
KILNS
(i)
Emission Standards
Bull’s Trench Kiln (BTK)
Category*
Limiting
concentration in
mg/Nm
3
Particulate
matter
small
medium
large
1000
750
750
minium (metre)
Stack
height
Small 22 or induced draft fan
operating with minimum
draft of 50 mm WG with 12
metre stack height.
Medium 27 or induced draft fan
operating with minimum
draft of 50 mm WG with 15
metre stack height.
Large 30 or induced draft fan
operating with minimum
draft 50 mm WG with 17
metre stack height.
*Category Trench withdh (m) Production (bricks/day)
Small BTK <4.50 Less than 15,000
Medium
BTK
4.50-6.75 15,000-30,000
Large BTK Above 6.75
Above 30,000
1
Substituted by Rule 2 of the Environment (Protection) Fourth Amendment Rules, 2009 notified by G.S.R.543(E), dated
22.7.2009.
The Environment (Protection) Rules, 1986 473
(ii) Down-Draft Kiln (DDK)
Category++ Limiting concentration
in mg/Nm
3
Particulate
matter
small/large/medium 1200
Minimum (metre)
Stack height small 12
medium 15
large 18
++Category Production
(bricks/day)
small DDK Less than 15,000
medium DDK 15,000-30,000
large DDK Above 30,000
(iii) Vertical Shaft Kiln (VSK)
Category** Limiting concentraion
in mg/l Nm
3
Particulate
matter
small/large/medium 250
Minimum (metre)
Stack height small 11 (at least 5.5m from
loading platform)
medium 14 (at least 7.5 m from
loading platform)
large 16 (at least 8.5 m from
loading platform)
**Category No.of Shafts Production (bricks/day)
small VSK 1-3 Less than 15,000
medium VSK 4-6 15,000-30,000
large VSK 7 or more above 30,000
Notes:
1. Gravitational Settling Chamber along with fixed chimney of
appropriate height shall be provided for all Bull‘s Trench
kilns.
2. One chimney per shaft in Vertical Shaft Kiln shall be
provided. The two chimneys emanating from a shaft shall
either be joined (at the loading platform in case of brick
chimney or at appropriate level in case of metal chimney) to
from a single chimney.
3. The above standards shall be applicable for different kilns if
coal, firewood and/or agricultural residues are used as fuel].
The Environment (Protection) Rules, 1986 474
75. SODA ASH INDUSTRY (SOLVAY PROCESS)
PARAMETER MINAS (Recipient body specified)
________________________________________
Marine Brackish Inland surface
pH 6.5—9 6.5—9 6.5—9
Temperature 45
o
C or less 45
o
C or less 45
o
C or less
Oil & Grease 2 mg/l 20 mg/l 10 mg/l
Suspended Solids(SS) 500 mg/l 200 mg/l 100 mg/l
Ammoniacal nitrogen 5 mg/l 50 mg/l 30 mg/l
Bio-assay 96 hours 96 hours 96 hours
30% survival 90% survival 90% survival
Note :- MINAS for disposal in brackish and inland surface water are without any
dilution.
Standards for Dual Process Soda Ash Plants :
Parameter MINAS
___________________
(Inland Surface Water)
pH 6.5—8.0
Ammoniacal nitrogen, as N(mg/l) 50
Nitrate nitrogen, as N(mg/l) 10
Cyanide, as CN(mg/l) 0.2
Hexavalent chromium(mg/l) 0.1
Total chromium(mg/l) 2.0
Suspended solids(mg/l) 100
Oil and Grease (mg/l) 10
Note : The Standards are to be implemented by the industry in a time targeted schedule
1
[by December, 1999]. The progress on the time targeted implementation
schedule shall be periodically submitted by the industry to the State Pollution
Control Board and Central Pollution Control Board.
1
Substituted by Rule 2 (ii) of the Environment (Protection) (Second Amendment) Rules, 1999 notified by Notification
G.S.R.682(E), dated 5.10.1999.
The Environment (Protection) Rules, 1986 475
76. EMISSION STANDARD FOR SO2 FROM CUPOLA FURNACE :
Standard for Sulphur Dioxide emission from Cupola Furnace :
Characteristics Emission limit
Sulphur dioxide (SO2) emission 300 mg/Nm
3
at 12% CO2 corrections
To achieve the standard, foundries may install scrubber, followed by a stack six times the
diameter of the Cupola beyond the charging door.
Note : In case due to some technical reasons, installation of scrubber is not possible, then
value of SO2 to the ambient air has to be effected through the stack height.
77. SPECIFICATIONS OF MOTOR GASOLINE FOR EMISSION RELATED
PARAMETERS :
Sl. Characteristics Requirement Method of test
No. ref.to P:of IS:1448
(i) Reid Vapour Pressure at 38
o
C,Kpa 35 to 70 P : 39
(ii) Benzeno, Percent by volume,Max 5.0
(1)
P : 104
(iii) Lead Content(as Pb)g/l,Max 0.15(low leaded)(2) P : 38
0.013 (unleaded)
(iv) Sulphur, percent by mass, Max 0.10 (unleaded P : 34
0.20 (leaded)
(v) Potential Gum, g/m3, Max 50 ASTM 873 : 8
(vi) Gum (Solvent Washed)g/m3 Max 40 P : 29
(vii) Oxygenates Content Ether (MTBE, 15
ETBE) Alcohol, percent by volume,
Max
(viii) Phosphorus See Foot Note
(3)
ASTMD 3231
(1) 3.0 percent by volume maximum in metro cities by 2000 AD.
(2) 0.15 g/l by 31
st
December, 1996 (for entries country).
0.013 g/l by 1
st
April 1995 (in four metrocities);
by 1
st
December,1998(for all State capitals/UTs and major metro cities) and
by 1
st
April,2000 for the entire country.
(3) Phosphorous containing additives shall be absent.
The Environment (Protection) Rules, 1986 476
Note :
(a) Above specifications applied to leaded as well as unleaded petrol
except lead content.
(b) For new refineries coming up during or after 1997 the specification
applicable by 2000 for existing refineries shall be applicable by 1997.
78. SPECIFICATION OF DIESEL FUEL FOR EMISSION RELATED
PARAMETERS :
Sl.No. Characteristics Requirement Method of Test
Ref. To P : of
IS : 1448
(i) Density at 15
o
C, Kg/m3 820 to 880(
1
) P : 32
(ii) Cetane Number, Min 45
o
(
2
) P : 9
(iii) Distillation 85 percent by volume 350 P : 18
recovery at
o
C Max 95 percent
by volume recovery at
o
C,Max 370
(iv) Sulphur, percent by mass 0.50(
3
) P : 33
(1) 820 to 860 by 2000 AD
(2) 48 by 31
st
December,1998(except in the refineries- Digboi, Gauhati and
Bongaigaon Refineries & Petrochemicals Ltd.)
(3) (i) 0.50 percent by mass by 1st April 1996 in four metros and Taj Trapezium;
(ii) 0.25 percent by mass by 1st October,1996 in Taj Trapezium;
(iii) 0.25 percent by mass by 1st April,1996 throughout the country.
Note :
(a) Above specifications apply to HSD only.
(b) For new refineries coming during or after 1997 specification applicable
by 2000 for existing refineries shall be applicable by 1997.
(c) ‗P‘ refers to parts of IS : 1448.
The Environment (Protection) Rules, 1986 477
Sl.
No.
Industry Parameter Standard
New
Batteries
(at Green
Field
Site)
Rebuild
Batteries
Existing
Batteries
Fugitive Visible Emissions
1
[
2
79 COKE OVEN
PLANTS
(by product recovery
type)
(a) Leakage from door
(b) Leakage from charging lids
(c) Leakage from AP Covers
(d) Charging emission
(Second/charge)
5(PLD)*
1(PLL)*
4(PLO)*
16(with
HPLA)*
10(PLD)*
1(PLL)*
4(PLO)*
50 (with
HPLA)*
10(PLD)*
1 (PLL)*
4(PLO)*
75
Stack Emission of Coke Oven
(a) SO2(mg/Nm
3
)
(b) NOx,(mg/ Nm
3
)
(c) SPM,(mg/Nm
3
)
800
500
50
800
500
50
800
500
50
(d) SPM emission during
charging – for stamp
charging batteries (stack
emission) mg/Nm
3
(e) SPM emission during
coke pushing (stack
emission) gm/ton of coke
25
5
25
5
(applicable
to
stationary
land based
system)
25
-
(f) Sulphur in Coke Oven
gas used for heating
(mg/Nm
3
)
800 - -
Emission for quenching operation
(a) Particulate matter gm/tonne of
coke produced
50 50 -
Benzo-Pyerine (BaP)
concentration in work zone air
(µg/m
3
)
(a )Battery area (top of the battery)
(b) Other units in coke oven plant
(c )Ambient standards (mg/Nm
3
)
5
2
10
5
2
10
5
2
10
1
Substituted by Rule 2(vi) by Rule 2(VI) of the Environment (Protection) First Amendment Rules, 2006 notified vide
Notification G.S.R.46(E), dated 3.2.2006.
2
Sl. No. 79 and entries relating thereto inserted by the Environment (Protection) Second Amendment Rules, 1997 vide
G.S.R. 631(E), dated 31.10.1997.
The Environment (Protection) Rules, 1986 478
For control of emissions and to maintain environmental quality in work zone
area, the following guidelines shall be followed, namely:-
(i) New coke oven units shall follow any of the low-emission procedures,
such as, coke dry cooling, non-recovery coke-ovens. Indirect
Quenching Process, Jumbo coke oven reactor, Modified Wet Quenching
System with appropriate environmental controls (e.g. baffles, filtering
media, collection and treatment of residual water from quench tower and
recycling; Use of process water as quenching water shall not be
permissible).
(ii) Effective pollution control measures (for e.g. Extensive maintenance and
cleaning of oven doors and frame seals, ascension pipes, charging holes
and lids and other equipment; On-main charging system(HPLA);
Luting charging holes with clay-suspension; Modified guide/transfer car
with emission control system etc. shall be used to reduce coal charging
and coke pushing emissions.
(iii) During rebuilding or installing new coke oven batteries, the following
clean technology and pollution control measures be adopted:
(a) air-cooled self-sealing doors;
(b) the hydro-jet cleaning system shall be provided for the door and
door frame cleaning with a facility of hydro jet pressure of 600
kg/cm
2
;
(c) the charging should be accomplished with hermetically sealed
charging sleeves and screw feeder in charging car. The charging
car should also be equipped with magnetic lid lifter and lid and
frame cleaning mechanism (applicable to top charging batteries);
(d) to provide aspiration through high-pressure ammonia liquor
(HPLA) injection in goose neck and emission should be
transferred directly to gas collecting mains;
(e) water sealed AP covers should be provided;
(f) computerized combustion control and moisture control systems.
(iv) In addition to the above the new coke oven batteries, which will be
installed after the date of publication of this notification at green field
site and rebuild batteries wherever technically feasible should also be
equipped to treat their pushing emissions with stationary land-based
system with collection hood and wet scrubbing units for gas cleaning.
The Environment (Protection) Rules, 1986 479
(v) In the case of existing coke ovens with wet quenching, the new procedures as in
(i) and (ii) shall be adopted.
(vi) The fugitive visible emission standards i.e. PLD*, PLL* and PLO*, charging
emission (second/charge).
Note: Units set up after the publication of this notification shall be treated as new
units.
*HPLA - Aspiration through high pressure liquor injection in gooseneck;
*PLD - Percent leaking doors;
* PLL - Percent leaking lids; and
* PLO - Percent leaking off takes].
1
[80. SPECIFICATIONS OF TWO-STROKE ENGINE OIL :
Specification Standard Test Procedure
Two-stroke engine oil grade Minimum smoke JASO-M342-92 for
JASO-FC as per Index of 85. JASO-FC and ASTM
D-4857 for API TC
JASO M-345-93 specification
And API TC as per specification
No.ASTM D 4859
The above specification shall be effective from the 1
st
day of April,1999.]
2
[81. BATTERY MANUFACTURING INDUSTRY
(i) Lead Acid Battery Manufacturing Industries. Emission Standards.
Source
Pollutant Concentration based
Standards
(mg/Nm
3
)
Grid casting Lead
Particulate matter
10
25
Oxide manufacturing Lead
Particulate matter
10
25
Paste mixing Lead
Particulate matter
10
25
Assembling Lead
Particulate matter
10
25
PVC Section Particulate matter 150
1
Sl. No. 80 and entries relating thereto inserted by the Environment (Protection) Amendment Rules, 1998 vide G.S.R.
504 (E), dated 20.8.1998.
2
Sl. No. 81 to 87 and entries relating thereto inserted by the Environment (Protection) Amendment Rules, 1998 vide
G.S.R. 7 (E), dated 22.12.1998.
The Environment (Protection) Rules, 1986 480
- To comply with the respective standards, all the emissions from above-
mentioned sources shall be routed through stack connected with hood and fan in
addition to above, installation of control equipment viz. Bag filter/ventury
scrubber, is also recommended.
- The minimum stack height shall be 30 m.
Liquid Effluent Discharge Standards
________________________________________________________________________
Pollutant Concentration based standards
pH 6.5—8.5
Suspended solids 50 mg/1
Lead 0.1 mg/l
(ii) Dry Cell Manufacturing Industry : Emission Standards
Pollutant Concentration based Standards
(mg/Nm
3
)
Particulate matter 50
Manganese as Mn 5
- To Comply with the respective standards, all the emissions from above-
mentioned sources shall be routed through stack connected with hood and fan. In
addition to above, installation of control equipment viz. bag filter/ventury
scrubber, is also recommended.
- The minimum stack height shall be 30m.
Effluent Standards
Pollutant Concentration based standards
pH 6.5---8.5
Total suspended solids 100 mg/l
Manganese as Mn 2 mg/l
Mercury as Hg 0.02 mg/l
Zinc as Zn 5 mg/l
(iii) Secondary Lead Smelters
Pollutant Concentration based standards
Lead as Pb 10 mg/Nm
3
Particulate matter 50 mg/Nm
3
Minimum stack height 30 m
The Environment (Protection) Rules, 1986 481
82. ENVIRONMENTAL STANDARDS FOR GAS/NAPTHA-BASED
THERMAL POWER PLANTS
(i) Limit for emissions of NOx
(a) For existing units---150ppm (v/v) at 15% excess oxygen.
(b) For new units with effect from 1.6.1999.
Total generation of gas turbine Limit for Stack NOx emission [v/v),at 15%
excess oxygen]
(a) 400 MW and above (i) 50 ppm for the units burning natural gas.
(ii) 100 ppm for the units burning naphtha.
(b) Less than 400 MW but (i) 75 ppm for the units burning natural gas.
Upto 100 MW (ii) 100 ppm for the units burning naphtha
(c) Less than 100 MW 100 ppm for units burning natural gas or
naphtha as fuel
(d) For the plants burning 100 ppm
gas in a conventional
boiler.
(ii) Stack height H in m should be calculated using the formula H=14 Q
0.3
, where Q
is the emission rate of SO2 in kg/hr, subject to a minimum of 30 mts.
(iii) Liquid waste discharge limit.
Parameter Maximum limit of concentration
(mg/l except for pH and temperature)
pH 6.5-8.5
Temperature As applicable for other thermal power Plants
Free available chlorine 0.5
Suspended solids 100.0
Oil and grease 20.0
Copper (total) 1.0
Iron (total) 1.0
Zinc 1.0
Chromium (total) 0.2
Phosphate 5.0
The Environment (Protection) Rules, 1986 482
1
[83. STANDARDS/GUIDELINES FOR CONTROL OF NOISE POLLUTION
FROM STATIONARY DIESEL GENERATOR(DG) SETS
* * * ………… ]
84. TEMPERATURE LIMIT FOR DISCHARGE OF CONDENSER
COOLING WATER FROM THERMAL POWER PLANT
A . New thermal power plants commissioned after June 1,1999.
New thermal power plants, which will be using water from rivers/lakes./
reservoirs shall install cooling towers-irrespective location and capacity.
Thermal power plants which will use sea water for cooling purposes, the
condition below will apply.
B. New projects in coastal areas using sea water.
The thermal power plants using sea water should adopt suitable system
to reduce water temperature at the final discharge point so that the
resultant rise in the temperature of receiving water does not exceed 7
o
C
over and above the ambient temperature of the receiving water bodies.
C. Existing thermal power plants.
Rise in temperature of condenser cooling water from inlet to the outlet of
condenser shall not be more than 10
o
C.
D. Guidelines for discharge point :
1. The discharge point shall preferably be located at the bottom of the water
body at mid-stream for proper dispersion of thermal discharge.
2. In case of discharge of cooling water into sea, proper marine outfall shall
be designed to achieve the prescribed standards. The point of discharge
may be selected in consultation with concerned State Authorities/NOI.
3. No cooling water discharge shall be permitted in estuaries or near
ecologically sensitive areas such as mangroves, coral reefs/spawning and
breeding grounds of acquatic flora and fauna.
85. ENVIRONMENTAL STANDARDS FOR COAL WASHERIES
1. Fugitive emission standards.
- The difference in the value of suspended particulate matter, delta (∆),
measured between 25 and 30 metre from the enclosure of coal crushing
plant in the downward and leeward wind direction shall not exceed 150
microgram per cubic meter. Method of measurement shall be High
Volume Sampling and Average flow rate, not less than 1.1 m
3
per
minute, using upwind downwind method of measurement :
1 Serial No..83 and entries relating thereto omitted by Rule 2 (b) of the Environment (Protection) Second Amendment
Rules, 2002 notified vide notification G.S.R. 371(E), dated 17.5.2002.
The Environment (Protection) Rules, 1986 483
2. Effluent discharge standards
- The coal washeries shall maintain the close circuit operation with zero
effluent discharge.
- If in case due to some genuine problems like periodic cleaning of the
system, heavy rainfall etc. it become necessary to discharge the effluent
to sewer land stream then the effluent shall conform to the following
standards at the final outlet of the coal washery.
S.No. Parameter Limits
1. pH 5.5—9.0
2. Total suspended solids 100 mg/l
3. Oil & Grease 10 mg/l
4. B.O.D (3 days 27
o
C) 30 mg/l
5. COD 250 mg/l
6. Phenolics 1.0 mg/l
3. Noise level standards
- Operational/Working zone—not to exceed 85 dB(A) Leq for 8 hours
exposure.
- The ambient air quality standards in respect of noise as notified under
Environmental (Protection)Rules,1986 shall be followed at the boundary
line of the coal washery.
4. Code of practice for Coal Washery.
- Water or Water mixed chemical shall be sprayed at all strategic coal
transfer points such as conveyors, loading/unloading points etc. As far
as practically possible conveyors, transfer points etc. shall be provided
with enclosures.
- The crushers/pulverisers of the coal washeries shall be provided with
enclosures, fitted with suitable air pollution control measures and finally
emitted through a stack of minimum height of 30m. conforming
particulate matter emission standard of 150 mg/Nm3 or provided with
adequate water sprinkling arrangement.
- Water sprinkling by using fine atomizer nozzeles arrangement shall be
provided on the coal heaps and on around the crushers/pulverisers.
- Area, in and around the coal washery shall be pucca either asphalted or
concreted.
The Environment (Protection) Rules, 1986 484
- Water consumption in the coal washery shall not exceed 1.5 cubic meter
per tonne of coal.
- The efficiency of the setting ponds of the waste water treatment system
of the coal washery shall not be less than 90%.
- Green belt shall be developed along the road side, coal handling plants,
residential complex, office building and all around the boundary line of
the coal washery.
- Storage bunkers, hoppers, rubber decks in chutes and centrifugal chutes
shall be provided with proper rubber linings.
- Vehicles movement in the coal washery area shall be regulated
effectively to avoid traffic congestion. High pressure horn shall be
prohibited. Smoke emission from heavy duty vehicle operating in the
coal washeries should conform the standards prescribed under Motor
Vehicle Rules,1989.
86. WATER QUALITY STANDARDS FOR COASTAL WATERS MARINE
OUTFALLS
In a coastal segment marine water is subjected to several types of uses. Depending of the
types of uses and activities, water quality criteria have been specified to determine its
suitability for a particular purpose. Among the various types of uses there is one use that
demands highest level of water quality/purity and that is termed a ―designated best use‖
in that stretch of the coastal segment. Based on this, primary water quality criteria have
been specified for following five designated best uses :-
Class Designated best use
SW-1(See Table 1.1.) Salt pans, Shell fishing, Mariculture and Ecologically
Sensitive Zone
SW-II (See Table 1.2) Bathing, Contact Water Sports and Commercial fishing.
SW-III (See Table 1.3) Industrial cooling, Recreation(non-contact) and Aesthetics
SW-IV (See Table 1.4) Harbour
SW-V (See Table 1.5) Navigation and Controlled Waste Disposal
The Standards alongwith rationale/remarks for various parameters for different
designated best uses, given in Table 1.1 to 1.5
The Environment (Protection) Rules, 1986 485
TABLE 1.1
PRIMARY WATER QUALITY CRITERIA FOR CLASS SW-1 WATERS
(For Salt pans, Shell fishing, Mariculture and Ecologically Sensitive Zone)
S.
No.
Parameter Standards Rationale/Remarks
1. 2. 3. 4.
1. pH range 6.5---8.5 General broad range, conductive
for propagation of acquaitc lives
is given. Value largely dependant
upon soil-water interation.
2. Dissolved Oxygen 5.0 mg/l or 60 per cent
saturation value
whichever is higher
Not less than 3.5 mg/l at any time
of the year for protection of
aquatic lives.
3. Colour and Odour No noticeable colour or
offensive odour.
Specially caused by chemical
compound like creosols, phenols,
naptha pyridine benzene, toluene
etc. causing visible colouration of
salt crystal and fainting fish flesh.
4. Floating Matters Nothing obnoxious or
detrimertal for use
purpose
Surfactants should not exceed an
upper limit of 1.0 mg/l and the
concentratic not to cause any
visible foam.
5. Suspended Solids None from sewage or
industrial waste origin
Settleable innert matters not in
such concentration that would
impair any usages specially
assigned to this class.
6. Oil and Grease
(including Petroleum
Products)
0.1 mg/l Concentration should not exceed
0.1 mg/l as because it has effect
on fish eggs and larvae.
1
[7. Heavy Metals :
Mercury (as Hg)
Lead (as Pb)
Cadmium (as Cd)
0.001 mg/l
0.001 mg/l
0.01 mg/l]
Values depend on :
(i) Concentration in salt,fish and
shell fish.
(ii) Average per capita
consumption per day.
(iii)Minimum ingestion rate that
induces symptoms of resulting
diseases.
Note : SW-1 is desirable to be safe and relatively free from hazardous chemicals like pesticides, heavy
metals and radionuclide concentrations. Their combined (synergistic or antagonistic) effects on health
and aquatic lives are not yet clearly known. These chemicals undergo bio-accumulation, magnification
and transfer to human and other animals through food chain. In areas where fisheries, salt pans are the
governing considerations, and presence of such chemicals apprehended/reported, bioassay test should
be performed following appropriate methods for the purpose of setting case specific limits.
1
Substituted by Rule 2(iii) of the Environment (Protection) (Second Amendment) Rules, 1999 published in the
Notification G.S.R.682(E), dated 5.10.1999.
The Environment (Protection) Rules, 1986 486
TABLE 1.2
PRIMARY WATER QUALITY CRITERIA FOR CLASS SW-II WATERS
(For Bathing, Contact Water Sports and Commercial Fishing)
S.No. Parameter Standards Rationale/Remarks
1. 2. 3. 4.
1. pH range 6.5---8.5 Range does not cause skin or
eye irritation and is also
conducive for propagation of
aquatic lives.
2. Dissolved Oxygen 4.0 mg/l or 50 per
cent saturation value
whichever is higher.
Not less than 3.5 mg/l at
anytime for protection of
aquatic lives.
3. Colour and Odour No noticeable colour
or offensive odour
Specially caused by chemical
compound like creosols
phenols, naptha, benzene,
pyridine toluene etc. causing
visible colouration of water
and tainting of and odour in
fish flesh.
4. Floating Matters Nothing obnoxious or
detrimental for use
purposes.
None in such concentration
that would impair usages
specially assigned to this class.
5. Turbidity 30 NTU (Nephelo
Turbidity Unit)
Measured at 0.9 depth
6. Fecal Coliform 100/100 ml(MPN) The average value not
exceeding 200/100 ml in 20
per cent of samples in the year
and in 3 consecutive samples
in monsoon months.
7. Biochemical Oxygen
Demand (BOD) (3 days at
27
o
C)
3 mg/l Restricted for bathing
(aesthetic quality of water).
Also prescribed by IS : 2296-
1974.
The Environment (Protection) Rules, 1986 487
TABLE 1.3
PRIMARY WATER QUALITY CRITERIA FOR CLASS SW-III WATERS
[For Industrial Cooling, Recreation (non-contact) and Aesthetics]
S.No. Parameter Standards Rationale/Remarks
1. 2. 3. 4.
1. pH range 6.5---8.5 The range is conducive for
propagation of aquatic
species and restoring natural
system.
2. Dissolved Oxygen 3.0 mg/l or 40 per
cent saturation value
whichever is higher.
To protect aquatic lives.
3. Colour and Odour No noticeable colour
or offensive odour
None in such concentration
that would impair usages
specifically assigned to this
class.
4. Floating Matters No visible,
obnoxious floating
debris, oil slick,
scum.
As in (3) above.
5. Fecal Coliform 500/100 ml(MPN) Not exceeding 1000/100 ml
in 20 percent of samples in
the year and in 3 consecutive
samples in monsoon months.
6. Turbidity 30 NTU Reasonably clear water for
Recreation Aesthetic
appreciation and Industrial
cooling purposes.
*7. Dissolved Iron (as Fe) 0.5 mg/l or less It is desirable to have the
collective concentration
dissolved Fe and Mn less or
equal to 0.5 mg/l to avoid
scaling effect.
*8. Dissolved Manganese
(as Mn)
0.5 mg/l or less
* Standards included exclusively for Industrial Cooling purpose. Other parameters
same.
The Environment (Protection) Rules, 1986 488
TABLE 1.4
PRIMARY WATER QUALITY CRITERIA FOR CLASS SW-IV WATERS
( For Harbour Waters)
S.No. Parameter Standards Rationale/Remarks
1. 2. 3. 4.
1. pH range 6.0---9.0 To minimize corrosive and
scaling effect.
2. Dissolved Oxygen 3.0 mg/l or 40 per
cent saturation value
whichever is higher.
Considering bio-degradation
of oil and inhibition to
oxygen production thorugh
photosynthesis.
3. Colour and Odour No visible colour or
offensive odour
None from reactive
chemicals which may
corrode paints/ metallic
surfaces.
4. Floating materials, Oil,
grease and scum
(including Petroleum
products)
10 mg/l Floating matter should be
free from excessive living
organisms which may clog or
coat operative parts of
marine vessels/equipment.
5. Fecal Coliform 500/100 ml(MPN) Not exceeding 1000/100 ml
in 20 per cent of samples in
the year and in 3 consecutive
samples in monsoon months.
6. Biochemical Oxygen
Demand (3 days at 27
o
C)
5mg/l To maintain water relatively
free from pollution caused by
sewage and other
decomposable wastes.
The Environment (Protection) Rules, 1986 489
TABLE 1.5
PRIMARY WATER QUALITY CRITERIA FOR CLASS SW-V WATERS
(For Navigation and Controlled Waste Disposal)
S.No. Parameter Standards Rationale/Remarks
1. 2. 3. 4.
1. pH range 6.0---9.0 As specified by New
England Interstate Water
Pollution Control
Commission.
2. Dissolved Oxygen 3.0 mg/l or 40 per
cent saturation value
whichever is higher.
To protect aquatic lives.
3. Colour and Odour None in such
concentrations that
would impair any
usages specifically
assigned to this class.
As in (i) above.
4. Sludge deposits, Solid
refuse floating solids, oil
grease and scum.
None except for such
small amount that
may result from
discharge of
appropriately treated
sewage and or
industrial waste
effluents.
As in (i) above.
5. Fecal Coliform 500/100 ml (MPN) Not exceeding 1000/100 ml
in 20 per cent of samples in
the year and in 3 consecutive
samples in monsoon months.
The Environment (Protection) Rules, 1986 490
87. EMISSION REGULATIONS FOR RAYON INDUSTRY
A. Existing Plants
Estimation of Uncontrolled Emission Quantity (EQ) of CS2 :
For VSF,
EQ = 125 kg of CS2/t of fibre
For VFY,
EQ = 225 kg of CS2/t of fibre
Stack Height (H) requirement, m Remarks
11 Q 0.41-3Vs D/u A minimum of 80% of total emission
shall pass through stack. If the
calculated stack height is less than 30m,
a minimum of height 30 m shall be
provided
_______________________________________________________________________
Where Q ----CS2 emission rate, kg/hr
VS---stack exit velocity, m/sec.
D ---diameter of stack, m.
U ----annual average wind speed at top of stack, m/sec.
Multiple Stacks
1. If there are more than one stack existing in the plant, the required height of all
stacks shall be based on the maximum emission rate in any of the stacks. In other
words, all the stacks carrying CS2 emission shall be of same heights (based on the
maximum emission rate).
2. Number of stacks shall not be increased from the existing number. However, the
number of stacks may be reduced. The existing stacks may be rebuilt and if
stacks are to be relocated condition 3 below applies.
3. Spacing among the stacks (x) at the minimum shall be 3.0 H (in m). If distance,
x, between two stacks is less than 3.0 H (in m), emission shall be considered as
single point source and height of both the stacks shall be calculated considering
all emission is going through one stack.
The Environment (Protection) Rules, 1986 491
B. Ambient Air Quality Monitoring
The industry shall install three air quality monitoring stations for CS2 and H2S
measurements in consultation with State Pollution Control Board (SPCB) to
ensure attainment of WHO recommended ambient air quality norms (CS2 = 100
ug/m
3
and H2S = 150 ug/m
3
, 24 = hr. average).
1
[C. For new plants/expansion projects being commissioned on or after 1.6.1999
For new plants or expansion projects, the emission standards for existing plants
covered in (a) above shall apply subject to compliance of the ambient air quality
norms for CS2 and H2S indicated in (b) above. The new plants or expansion
projects shall provide adequate space for undertaking retrofittings.
(Note : a and b above also apply to new plants or expansion projects).]
2
[88. EMISSION STANDARDS FOR NEW GENERATOR SETS (UPTO 19
KILOWATT) RUN ON PETROL AND KEROSENE WITH IMPLEMENTATION
SCHEDULE.
The emission standards for portable generator sets run on petrol and kerosene
shall be follows :-
A. From June 1,2000
Class Displacement
(CC)
CO(g/kw-hr) HC+NOx(g/kw-hr)
2-stroke
engine
4-stroke
engine
2-stroke
engine
4-stroke
engine
1. ≤65 603 623 166 65
2. >65 ≤ 99 - 623 - 36
3. >99 ≤225 - 623 - 19.3
4. >225 - 623 - 16.1
1
Substituted by Rule 2(i) of the Environment (Protection) Second Amendment Rules, 2006 notified by G.S.R.640(E),
dated 16.10.2006.
2
Sl. No. 88 and 89 and entries relating thereto inserted by the Environment (Protection) (Second Amendment) Rules,
1999 vide G.S.R. 682 (E), dated 5.10.1999.
The Environment (Protection) Rules, 1986 492
B. From June 1,2001
Class Displacement
(CC)
CO(g/kw-hr) HC+NOx(g/kw-hr)
1. ≤65 519 54
2. >65 ≤99 519 30
3. >99 ≤225 519 16.1
4. >225 519 13.4
C. Test method shall be as specified in SAE J 1088. Measurement mode shall be D1
cycle specified under ISO 8178 (Weighting Factor of 0.3 for 100 % load, 0.5 for 75%
load and 0.2 for 50% load).
D. Following organizations shall test and certify the generator sets :-
1
[(i) Automotive Research Association of India, Pune.
(ii) Indian Institute of Petroleum, Dehradun.
(iii) Indian Oil Corporation, R&D Centre, Faridabad.
(iv)]Vehicle Research Development Establishment, Ahmedbagar.
2
[(v)International Centre for Automotive Technology, Manesar (Haryana)]
These organizations shall submit the testing and certification details to the Central
Pollution Control Board, annually. The Central Pollution Control Board may send the
experts in the field to oversee the testing.
89 . NOISE STANDARDS FOR FIRE-CRACKERS
A. (i) The manufacture, sale or of fire-crackers generating noise level exceeding
125 dB(AI) of 145dB(C) at 4 metres distance from the point of bursting shall
be prohibited.
(ii) For individual fire-cracker constituting the series (joined fire-crackers), the
above mentioned limit be reduced by 5 log10 (N) dB, where N= number of
crackers joined together.
1
Renumbered as (i), (ii), (iii) and (iv) respectively by Rule 2(a) of the Environment (Protection) Second Amendment
Rules, 2008 notified by G.S.R.280(E), dated 11.4.2008.
2
Inserted by Rule 2(a), ibid.
The Environment (Protection) Rules, 1986 493
B. The broad requirements for measurement of noise from fire-crackers shall be-
(i) The measurements shall be made on hard concrete surface of minimum 5
metre diameter or equivalet.
(ii) The measurements shall be made in free field conditions i.e., there shall not
be any reflecting surface upto 15 metre distance from the point of bursting.
(iii) The measurement shall be made with an approved sound level metre.
C. The Department of Explosive shall ensure implementation of these standards.
1
[D. The fire crackers for the purpose of export shall be exempted from the sub-
paragraphs A, B and C above subject to the compliance of the following
conditions, namely :-
(i) the manufacturer shall have an export order;
(ii) the fire crackers shall conform to the level prescribed in the country to
which it is exported;
(iii) they shall have a different packing colour code, and
(iv) there shall be a declaration on the box ―not for sale in India‖ or
―only for export in other countries‖.]
Note : dB(A1) : A-weighted impulse sound pressure level in decibel.
dB(C)pk : C – weighted peak sound pressure level in decibel.]
Footnote : The Principal Rules were published in the Gazette of India vide Notification
No.S.O.844 (E), dated the19th November, 1986 and subsequently amended vide :
(1) S.O.82(E), dt. 16
th
February, 1987
(2) S.O393 (E), dt 16
th
April, 1987;
(3) S.O.443(E),dt 18
th
April, 1987
(4) S.O.64(E),dt. 18
th
January, 1988
(5) G.S.R.919(E),dt.12
th
Sept., 1988
(6) S.O.8(E),dt. 3
rd
January 1989
(7) G.SR.913(E),dt. 24
th
October 1989
(8) S.O.914(E),dt. 24
th
October, 1989
(9) G.S.R.931(E),dt.27
th
October, 1989
(10) G.S.R.103(E),dt. 25
th
Dec.,1989
(11) S.O.12(E),dt. 8
th
January, 1999
(12) G.S.R.54(E),dt.5
th
February, 1990
(13) S.O.136(E),dt.9
th
February, 1990
(14) G.S.R.742(E),dt.13
th
August, 1990
(15) S.O.23(E),dt.16
th
January, 1991
(16) S.O.80(E),dt. 8
th
February, 1991
(17) S.O.114(E),dt.19
th
February,1991
(18) G.S.R.85(E),dt.20
th
February, 1991
(19) G.S.R.93(E),dt 21
h
February, 1991
(20) S.O.190(E),dt.18
th
March, 1991
(21) S.O.416(E),dt. 20
th
June, 1991
(22) S.O.479(E), dt. 25
th
July, 1991
(23) S.O.23(E),dt 9
th
January, 1992
1
Inserted sub paragraph D by Rule 2(ii) of the Environment (Protection) Second Amendment Rules, 2006 notified by
G.S.R.640(E), dated 16.10.2006.
The Environment (Protection) Rules, 1986 494
1
[90. STANDARDS FOR COAL MINES
1. AIR QUALITY STANDARDS
The Suspended Particulate Matter (SPM), Respirable Particulate Matter (RPM), Sulphur
dioxide (SO2) and Oxides of Nitrogen (NOx) concentration in downwind direction
considering predominant wind direction, at a distance of 500 metres from the following
dust generating sources shall not exceed the standards specified in the Tables I, II and III
given below:
Dust Generating Sources
Loading or unloading, Haul road, coal transportation road, Coal handling plant (CHP),
Railway sliding, Blasting, Drilling, Overburden dumps, or any other dust generating
external sources like coke ovens (hard as well as soft), briquette industry, nearby road
etc.
Table-I
Category Pollutant Time
weighted
average
Concentration
in Ambient
Air
Method of
Measurement
1 2 3 4 5
I
New Coal
Mines (Coal
Mines
commenced
operation
after the date
of
publication
of this
notification)
Suspended
Particulate
Matter
(SPM)
Annual
Average *
24 hours **
360 µg/m
3
500 µg/m
3
- High Volume Sampling
(Average flow rate not
less than 1.1 m
3
/min)
Respirable
Particulate
Matter
(size less
than 10
µm) (RPM)
Annual
Average *
24 hours **
180 µg/m
3
250 µg/m
3
Respirable Particulate
Matter sampling and
analysis
Sulphur
Dioxide
(SO2)
Annual
Average *
24 hours **
80 µg/m
3
120 µg/m
3
- Improved west and Gaeke
method
- Ultraviolet fluorescene
Oxide of
Nitrogen as
NO2
Annual
Average *
24 hours **
80 µg/m
3
120 µg/m
3
- Jacob & Hochheiser
Modified (Na-Arsenic)
Method
- Gas phase
Chemiluminescence
1
Serial No.90 to 93 and entries relating thereto were inserted by Rule 2(1) of the Environment (Protection)
Amendment Rules, 2000 notified vide notification G.S.R. 742(E), dated 25.9.2000.
The Environment (Protection) Rules, 1986 495
Table-II
Category Pollutant Time
weighted
average
Concentration
in Ambient
Air
Method of
Measurement
1 2 3 4 5
II
Existing coal
fields/mines
given below:
Karanpura,
Ramgarh,
Giridih,
Rajhara,
Wardha,
Nagpur,
Silewara, Pench
Kanhan,
Patharkhera,
Umrer, Korba,
Chirimiri,
Central India
Coalfields,
(including
Baikunthpur,
Bisrampur),
Singrauli, Ib
Valley,
Talcher,
Godavary
Valley and any
other
Suspended
Particulate
Matter
(SPM)
Annual
Average *
24 hours **
430 µg/m
3
600 µg/m
3
- High Volume
Sampling
(Average flow rate
not less than 1.1
m
3
/minute)
Respirable
Particulate
Matter
(size less
than 10
µm)
(RPM)
Annual
Average *
24 hours **
215 µg/m
3
300 µg/m
3
Respirable
Particulate Matter
sampling and
analysis
Sulphur
Dioxide
(SO2)
Annual
Average *
24 hours **
80 µg/m
3
120 µg/m
3
1. Improved west and
Gaeke method
2. Ultraviolet
fluorescene
Oxide of
Nitrogen as
NO2
Annual
Average *
24 hours **
80 µg/m
3
120 µg/m
3
1. Jacob &
Hochheiser
Modified (Na-
Arsenic) Method
2. Gas phase
Chemilumine-
scence
The Environment (Protection) Rules, 1986 496
Table-III
Category Pollutant Time
weighted
average
Concentration
in Ambient
Air
Method of
Measurement
1 2 3 4 5
III
Coal mines located
in the coal fields of
Jharia
Raniganj
Bokaro
Suspended
Particulate
Matter
(SPM)
Annual
Average
*
24 hours
**
500 µg/m
3
700 µg/m
3
- High Volume
Sampling
(Average flow
rate not less
than 1.1
m
3
/minute)
Respirable
Particulate
Matter
(size less
than 10
µm)
(RPM)
Annual
Average
*
24 hours
**
250 µg/m
3
300 µg/m
3
Respirable
Particulate Matter
sampling and
analysis
Sulphur
Dioxide
(SO2)
Annual
Average
*
24 hours
**
80 µg/m
3
120 µg/m
3
1.Improved west
and Gaeke
method
2.Ultraviolet
fluorescene
Oxide of
Nitrogen
as NO2
Annual
Average
*
24 hours
**
80 µg/m
3
120 µg/m
3
1. Jacob &
Hochheiser
Modified (Na-
Arsenic)
Method
2. Gas phase
Chemilumine-
scence
Note:
* Annual Arithmetic mean for the measurements taken in a year, following the
guidelines for frequency of sampling laid down in clause 2.
** 24 hourly / 8 hourly values shall be met 92% of the time in a year. However, 8%
of the time it may exceed but not on two consecutive days.
The Environment (Protection) Rules, 1986 497
Unauthorised construction shall not be taken as a reference of nearest residential
or commercial place for monitoring.
In case any residential or commercial or industrial place falls within 500 metres of any
dust generating sources, the National Ambient Air Quality Standards notified under
schedule VII shall be applicable.
2. FREQUENCY OF SAMPLING
– Air quality monitoring at a frequency of once in a fortnight at the dust generating
sources given in clause 1 shall be carried out.
– As a result of monthly monitoring, if it is found that the value of the pollutant is
less than 50% of the specified standards for three consecutive months, then the
sampling frequency may be shifted to two days in a quarter year (3 months).
– In case, the value has exceeded the specified standards, the air quality sampling
shall be done twice a week. If the results of four consecutive weeks indicate that
the concentration of pollutants is within the specified standards, then fortnight
monitoring may be reverted to.
3. EFFLUENT STANDARDS
The standards for effluent discharge into sewer or stream or land, are given below:
pH – 5.5 to 9.0
Chemical Oxygen Demand (COD) – 250 mg/l
Total Suspended Solids (TSS) – 100 mg/l
200 mg/l (Land for irrigation)
Oil & Grease (O & G) – 10 mg/l
(Monitoring frequency of these parameters shall be once in a fortnight)
Optional parameters : All other parameters indicated in the general standards
for discharge of environment pollutants under Schedule
VI, shall be in addition to the effluent standards
specified under clause 3. (Monitoring frequency shall be
once in a year for the optional parameters)
4. NOISE LEVEL STANDARDS
6.00 AM – 10.00 PM 10.00 PM – 6.00 AM
Noise level Leq 75 dB(A) Leq 70 dB(A)
(Monitoring frequency for noise level shall be once in a fortnight)
Occupational exposure limit of noise specified by Director General of Mines Safety
(DGMS) shall be complied with by the local mines.
The Environment (Protection) Rules, 1986 498
91. NOISE LIMIT FOR GENERATOR SETS RUN WITH PETROL OR
KEROSENE
1. Noise limit
Noise limit for new generator sets run with petrol or kerosene shall be as given below:
Noise Limit from
1
[September 1, 2002]
2
[September 1, 2003]
Sound Power level Lwa 90 dBA 86 dBA
2. Applicability
These rules shall apply to all new generator sets using petrol or kerosene as fuel,
manufactured in or imported into India:
Provided that these rules shall not apply to:
a) any genset manufactured or imported for the purpose of exports outside India, or
b) the genset is intended for the purpose of sample only and not for sale in India.
3. Requirement of certification
Every manufacturer or importer (hereinafter referred to as "supplier) of genset
(hereinafter referred to as "product") to which these rules apply must have a valid
certificate of type approval for all the product models being manufactured or imported
after the specified dates.
4. Verification of conformity of production (COP)
Every supplier shall subject its products to the verification for conformity of production,
by certification body specified in clause 8, every year.
5. Sale of generator sets not complying with these rules
The sale of product model, not having valid type approval certificate, or not complying
with the noise limits, as determined by the verification for conformity of production, shall
be prohibited, in India.
1
Substituted by Rule 2 of the Environment (Protection) Amendment Rules, 2001 published vide Notification
No.G.S.R.628(E), dated 30.8.2001 from ‗September 1. 2001 to September 1, 2002‘.
2
Substituted by Rule 2 of the Environment (Protection) Amendment Rules, 2001 published vide Notification
No.G.S.R.628(E), dated 30.8.2001 from ‗September 1. 2002 to September 1, 2003‘.
The Environment (Protection) Rules, 1986 499
6. Requirement of conformance labelling
6(1) The supplier of the ‗product‘ must affix a conformance label on the product
meeting the following requirements:
a) the label shall be durable and legible
b) the label shall be affixed on a part necessary for normal operation of the
‗product‘ and not normally requiring replacement during the ‗product‘ life.
6(2) The conformance label must contain the following information:
a) name & address of the supplier (if the address is described in the owners
manual, it may not be included in the label)
b) statement that "this product conforms to the Environment (Protection)
Rules, 1986
c) type approval certificate number and time phase (i.e. Sept 2001 or Sept
2002)
7. Nodal agency
(1) The Central Pollution Control Board shall be the nodal agency for
implementation of these rules.
(2) In case of any dispute or difficulty in implementation of these rules the matter
shall be referred to the nodal agency.
(3) The nodal agency shall constitute a Standing Committee to advise it on all
matters; including the disputed matters, related to the implementation of these
rules.
8. Certification body
The following agencies are authorised for type approval and for verification of
conformity of production.
(1) Automative Research Association of India, Pune;
(2) National Physical Laboratory, New Delhi;
(3) Naval Science & Technology Laboratory, Visakhapatnam;
(4) Fluid Control Research Institute, Palghat; and
(5) National Aerospace Laboratory, Bangalore.
9. Compliance and testing procedure
The compliance and testing procedure shall be prepared and published by Central
Pollution Control Board, with the help of the certification agencies.
The Environment (Protection) Rules, 1986 500
92. STANDARDS FOR EFFLUENTS FROM TEXTILE INDUSTRY
Parameter Concentration not to exceed, milligram
per litre (mg/l), except pH
pH 5.5 – 9.0
Total suspended solids 100
Bio-chemical oxygen demand (BOD) 30
Chemical oxygen demand (COD) 250
Total residual chlorine 1
Oil and grease 10
Total chromium as Cr 2
Sulphide as S 2
Phenolic compounds as C6H5OH 1
Note:
1. Where the treated effluent is discharged into municipal sewer leading to terminal
treatment plant, the BOD may be relaxed to 100 mg/l and COD to 400 mg/l
2. The quantity of effluent (litre per kilogram of product) shall not exceed 100, 250 and
80 in composite cotton textile industry, composite woolen textile industry and textile
processing industry, respectively.
93. PRIMARY WATER QUALITY CRITERIA FOR BATHING WATER
In a water body or its part, water is subjected to several types of uses. Depending on the
types of uses and activities, water quality criteria have been specified to determine its
suitability for a particular purpose. Among the various types of users there is one use that
demands highest level of water quality or purity and that is termed as "Designated Best
Use" in that stretch of water body. Based on this, water quality requirements have been
specified for different uses in terms of primary water quality criteria. The primary water
quality criteria for bathing water are specified along with the rationale in Table 1.
The Environment (Protection) Rules, 1986 501
Table 1
PRIMARY WATER QUALITY CRITERIA FOR BATHING WATER
(Water used for organised outdoor bathing)
CRITERIA RATIONALE
1.Fecal Coliform 500 (desirable)
MPN/100 ml: 2500 (Maximum
Permissible)
2.Fecal Streptococci 100 (desirable)
MPN/100 ml: 500 (Maximum
Permissible)
To ensure low sewage contamination Fecal
coliform and fecal streptococci are considered as
they reflect the bacterial pathogenicity.
The desirable and permissible limits are
suggested to allow for fluctuation in
environmental conditions such as seasonal
change, changes in flow conditions etc.
2. pH: Between 6.5 – 8.5 The range provides protection to the skin and
delicate organs like eyes, nose, ears etc. which
are directly exposed during outdoor bathing.
3.Dissolved Oxygen: 5 mg/l or more The minimum dissolved oxygen concentration
of 5 mg/l ensures reasonable freedom from
oxygen consuming organic pollution
immediately upstream which is necessary for
preventing production of anaerobic gases
(obnoxious gases) from sediment.
4.Biochemical Oxygen 3 mg/l or less
Demand 3 day, 27
0
C:
The Biochemical Oxygen Demand of 3 mg/l or
less of the water ensures reasonable freedom
from oxygen demanding pollutants and prevent
production of obnoxious gases.]
1
[94. NOISE LIMIT FOR GENERATOR SETS RUN WITH DIESEL
1. Noise limit for diesel generator sets (upto 1000 KVA) manufactured on or after
the
2
[1
st
January, 2005].
The maximum permissible sound pressure level for new diesel generator (DG) sets
with rated capacity up to 1000 KVA, manufactured on or after the
2
[1
st
January,
2005] shall be 75 dB(A) at 1 metre from the enclosure surface.
1
Serial No.94 and 95 and entries relating thereto were inserted by Rule 2(c) of the Environment (Protection)
Second Amendment Rules, 2002 notified vide Notification G.S.R.371(E), dated 17.5.2002.
2
Substituted by Rule 2(a) (i) of the Environment (Protection) Second Amendment Rules, 2004 notified vide
Notification No. G.S.R.448 (E), dated 12.7.2004 (Earlier it was 1
st
July 2003 as per the Environment
(Protection) Second Amendment, Rules, 2002 notified vide G.S.R. 371 (E), dated 17.5.2002. Subsequently,
substituted as 1
st
July, 2004 by the Environment (Protection) Amendment Rules, 2003 notified by G.S.R.520
(E), dated 1.7.2003 and later substituted as 1
st
January, 2005 by the Environment (Protection) Second
Amendment Rules, 2004 notified by G.S.R. 448, dated 12.7.2004).
The Environment (Protection) Rules, 1986 502
The diesel generator sets should be provided with integral acoustic enclosure at the
manufacturing stage itself.
The implementation of noise limit for these diesel generator sets shall be regulated as
given in paragraph 3 below.
2. Noise limit for DG sets not covered by paragraph 1.
Noise limits for diesel generator sets not covered by paragraph 1, shall be as
follows:
2.1 Noise from DG set shall be controlled by providing an acoustic enclosure or by
treating the room acoustically, at the users end.
2.2 The acoustic enclosure or acoustic treatment of the room shall be designed for
minimum 25 dB (A) insertion loss or for meeting the ambient noise standards,
whichever is on the higher side (if the actual ambient noise is on the higher side,
it may not be possible to check the performance of the acoustic
enclosure/acoustic treatment. Under such circumstances the performance may be
checked for noise reduction upto actual ambient noise level, preferably, in the
night time). The measurement for Insertion Loss may be done at different points
at 0.5 m from the acoustic enclosure/room, and then averaged.
2.3 The DG set shall be provided with proper exhaust muffler with insertion loss of
minimum 25 dB(A).
2.4 These limits shall be regulated by the State Pollution Control Boards and the
State Pollution Control Committees.
2.5. Guidelines for the manufacturers/users of Diesel Generator sets shall be as under:
1. The manufacturer shall offer to the user a standard acoustic enclosure of
25 dB(A) insertion loss and also a suitable exhaust muffler with insertion
loss of 25 dB(A).
2. The user shall make efforts to bring down the noise levels due to the DG
set, outside his premises, within the ambient noise requirements by
proper siting and control measures.
3. Installation of a DG set must be strictly in compliance with the
recommendations of the DG set manufacturer.
The Environment (Protection) Rules, 1986 503
4. A proper routine and preventive maintenance procedure for the DG set
should be set and followed in consultation with the DG set manufacturer
which would help prevent noise levels of the DG set from deteriorating
with use.
3. LIMITS OF NOISE FOR DG SETS (UPTO 1000 KVA) MANUFACTURED ON
OR AFTER THE
1
[1
ST
JANUARY, 2005].
3.1 Applicability
1. These rules apply to DG sets upto 1000 KVA rated output, manufactured or
imported in India, on or after
1
[1
st
January, 2005].
2. These rules shall not apply to:
(a) DG sets manufactured or imported for the purpose of exports outside
India; and
(b) DG sets intended for the purpose of sample and not for sale in India.
3.2 Requirement of Certification
2
[Every manufacturer or assembler or importer (hereinafter referred to as
"manufacturer")] of DG set (hereinafter referred to as "product") to which these
regulations apply must have valid certificates of Type Approval and also valid
certificates of Conformity of Production for each year, for all the product models
being
3
[manufactured or assembled or imported] from
1
[1
st
January, 2005] with
the noise limit specified in paragraph 1.
3.3 Sale, import or use of DG sets not complying with the rules prohibited
No person shall sell, import or use of a product model, which is not having a
valid Type Approval certificate and Conformity of Production certificate.
1
Substituted by Rule 2(a) (i) of the Environment (Protection) Second Amendment Rules, 2004 notified vide
Notification No. G.S.R.448 (E), dated 12.7.2004 (Earlier it was 1
st
July 2003 as per the Environment
(Protection) Second Amendment, Rules, 2002 notified vide G.S.R. 371 (E), dated 17.5.2002. Subsequently,
substituted as 1
st
July, 2004 by the Environment (Protection) Amendment Rules, 2003 notified by G.S.R.520
(E), dated 1.7.2003 and later substituted as 1
st
January, 2005 by the Environment (Protection) Second
Amendment Rules, 2004 notified by G.S.R. 448, dated 12.7.2004).
2
Substituted by Rule 2(a) (i) of the Environment (Protection) Eighth Amendment Rules, 2008 notified by G.S.R.752
(E), dated 24.10.2008.
3
Substituted by Rule 2(a) (ii) of the Environment (Protection) Eighth Amendment Rules, 2008 notified by G.S.R.752
(E), dated 24.10.2008.
The Environment (Protection) Rules, 1986 504
3.4 Requirement of Conformance Labelling
(i) The
1
[manufacturer] of the 'product' must affix a conformance label on the
product meeting the following requirements:
(a) The label shall be durable and legible.
(b) The label shall be affixed on a part necessary for normal operation of the
'product' and not normally requiring replacement during the 'product' life.
(ii) The conformance label must contain the following information:
(a) Name and address of the
2
[manufacturer] (if the address is described in
the owner's manual, it may not be included in the label.)
(b) Statement "This product conforms to the Environment (Protection)
Rules,1986".
(c) Noise limit viz. 75 dB(A) at 1 m.
(d) Type approval certificate number.
(e) Date of manufacture of the product.
3.5 Nodal Agency
(i) The Central Pollution Control Board shall be the nodal agency for
implementation of these regulations.
(ii) In case of any dispute or difficulty in implementation of these
regulations, the matter shall be referred to the nodal agency.
(iii) The nodal agency shall constitute a Committee to advise it on all matters;
including the disputed matters, related to the implementation of these
regulations.
3.6 Authorised agencies for certification
The following agencies are authorized to carry out such tests as they deem
necessary for giving certificates for Type Approval and Conformity of
Production testings of DG sets and to give such certificates:-
1
Substituted by Rule 2(b) of the Environment (Protection) Eighth Amendment Rules, 2008 notified by G.S.R.752 (E),
dated 24.10.2008.
2
Substituted ibid.
The Environment (Protection) Rules, 1986 505
(i) Automotive Research Association of India, Pune
(ii) National Physical Laboratory, New Delhi
(iii) Naval Science & Technology Laboratory, Visakhapatnam
(iv) Fluid Control Research Institute, Palghat
(v) National Aerospace Laboratory, Bangalore
3.7 Compliance and Testing Procedure
The compliance and testing procedure shall be prepared and published by the
Central Pollution Control Board, with the help of the certification agencies.
1
[4.0 Exemption from the provisions of paragraph 1 and3, for the products (diesel
generator sets upto 30 KVA) purchased by the Ministry of Defence, Govt. of
India
The products manufactured in or imported into India till
2
[30
th
April, 2007] for the
purpose of supplying to the Ministry of Defence, shall be exempted from the regulations
given in paragraph 1 to 3 above, subject to the following conditions, namely:-
(i) The
3
[manufacturer] shall manufacture or import the products only after getting
purchase order from the ministry of Defence and shall maintain the record of
receipts, production/import, dispatch, etc. for inspection by the Central Pollution
Control Board.
(ii) The special dispensation for noise norms shall be only for the mobile Defence
vehicles which, with the present design/configuration, cannot carry the gensets
with acoustic enclosures.
(iii) Director, Ministry of Defence shall ensure and maintain the serial number of all
gensets for the Army and he shall also direct the manufacturers of these genets to
emboss on the engine and the main body of the gensets, the words ‗For the use
of Army only’.
(iv) The genset serial number shall be specially assigned by Ministry of Defence with
the request for proposal and contract purchase order and this information shall be
forwarded to the Central Pollution Control Board for inspection as and when
required.
1
Inserted by Rule 2 of the Environment (Protection) Second Amendment Rules, 2005 notified vide Notification
G.S.R.315(E), dated 16.5.2005.
2
Substituted by Rule 2 of the Environment (Protection) Amendment Rules, 2006 notified by G.S.R.464(E), dated
7.8.2006.
3
Substituted by Rule 2(c) of the Environment (Protection) Eighth Amendment Rules, 2008 notified by G.S.R.752 (E),
dated 24.10.2008.
The Environment (Protection) Rules, 1986 506
(v) Registers shall be maintained at the manufacturers premises and in the Ministry
of Defence to ensure that the number of gensets manufactured under special
dispensation are not misused.
(vi) The gensets procured under this dispensation shall be operated in the remote
areas and not in the cities.
(vii) This shall be a one time exemption during which the Army shall remodel its
vehicles to contain the new gensets and also obtain the necessary Type Approval
of the gensets.]
1
[5.0 Exemption from the provisions of paragraph 1 and 3 for sixteen Diesel
Generator sets of 45 KVA purchased by the Ministry of Defence, Government
of India
The 45 KVA DG sets manufactured in India for the purpose of their use in Mobile
Decontamination System for use by the Ministry of Defence shall be exempted from
the regulations given in paragraph 1 to 3 above subject to the following conditions,
namely:-
(i) The special dispensation for the noise norms shall be only for the DG sets to
be used in Mobile Decontamination System (MDS) by Army which, with the
present design/configuration cannot carry the gensets with acoustic
enclosures.
(ii) The Director, Ministry of Defence shall ensure and maintain the serial
number for sixteen gensets and he shall also direct the manufacturers of these
generator sets to emboss on the engine and main body of the gensets, the
words ―For the use of Army only in Mobile Decontamination System
(MDS)‖.
(iii) A register shall be maintained at the manufacturers premises and in the
Ministry of Defence to ensure that only sixteen numbers of 45 KVA gensets
are manufactured under special dispensation and are not misused elsewhere.]
2
[6.0 Transportation of Diesel Generator Sets (above 250 KVA)
(i) Diesel Generator set shall be transported after fulfilling the requirement
of certification specified in paragraph 3.2 as a complete unit with
acoustic enclosure, or dismantled, with relevant genset number specified
on acoustic enclosure and silencer for reassembling of the site of its
operation.
1
Inserted by Rule 2 of the Environment (Protection) Amendment Rules, 2007 notified by G.S.R. 566(E), dated
29.8.2007.
2
Inserted by Rule 2(d) of the Environment (Protection) Eighth Amendment Rules, 2008 notified by G.S.R.752 (E),
dated 24.10.2008.
The Environment (Protection) Rules, 1986 507
(ii) Compliance with the noise norms shall be monitored after reassembling
the D.G. set at the location of the installation by the concerned State
Pollution Control Board or, as the case may be, the Union Territory
Pollution Control Committee.]
95. EMISSION LIMITS FOR NEW DIESEL ENGINES (UP TO 800 KW) FOR
GENERATOR SETS (GENSETS) APPLICATIONS
1
[1. Emission Limits
The emission limits for new diesel engines upto 800 kW for gensets
applications shall be as given in the Table below:
2
[TABLE
Capacity
of diesel
engines
Date of
imple-
mentation
Emission Limits
(g/kw-hr) for
Smoke
Limit
(light
absorption
coefficient,
m
-1
) (at
full load)
Test Cycle
NOX HC CO PM Torque
%
Weighting
Factor
Upto 19
kW
1.7.2005 9.2 1.3 3.5 0.3 0.7 100 0.05
75 0.25
>19 kW
upto 176
kW
1.1.2004 9.2 1.3 5.0 0.5 0.7 50 0.30
1.7.2004 9.2 1.3 3.5 0.3 0.7 25 0.30
>176 kW
upto 800
kW
1.11.2004 9.2 1.3 3.5 0.3 0.7 10 0.10
Explanation: This extension
3
[for engines upto 19 kW] shall be applicable only to those
suppliers:
1
Substituted by Rule 2(b) (i) of the Environment (Protection) Amendment Rules, 2003 notified vide Notification
G.S.R. 520 (E), dated 1.7.2003.
2
Substituted by Rule 2(b) of the Environment (Protection) Second Amendment Rule, 2004 notified vide Notification
G.S.R.448(E), dated 12.7.2004.
3
For the word ‗this extension‘, the word ‗this extension for engines upto 19 kW added by Corrigendum notified vide
Notification G.S.R.520(E), dated 12.8.2004.
The Environment (Protection) Rules, 1986 508
(I) Who have obtained Type Approval Certificate for atleast one of their engine
models in this range upto 30
th
June, 2004.
1
[or]
(II) Who have submitted the bank guarantee and also contributed towards the study
being carried out by the Union Institute of Science, Bangalore, for development
of gentset diesel engines to comply with emission limits.]
Note I:- The diesel engine
2
[suppliers] in the category of engines upto 19 kW, who are
unable to meet the emission limits fixed for such diesel engines for genstes applications
vide the notification of the Government of India, in the Ministry of Environment and
Forests number G.S.R. 371 (E) dated 17
th
May, 2002 (herein referred to as the said
notification), may avail the benefit of extension of time provided under this notification
subject to the condition that every such
1
[supplier] shall submit (i) an affidavit to the
Central Pollution Control Board or the respective State Pollution Control Board or
Committees where they are located to the effect that the specified emission limits shall be
compiled with by them as per the extended date of implementation given hereinabove for
that category of engines without seeking further extension of time and (ii) a bank
guarantee of Rs. 50,000 (Rupees Fifty Thousand) which in case of non compliance shall
stand forfeited.
Note II:- The diesel engine
1
[supplier] in the category of engines more than 19 kW and
upto 800 kW, who are unable to meet the emission limits fixed for such diesel engines for
gensets applications vide the said notification may avail the benefit of extension of time
provided under this notification subject to the condition that every such
1
[supplier] shall
submit (i) an affidavit to the Central Pollution Control Board or the respective State
Pollution Control Board or Committees where they are located to the effect that the
specified emission limits shall be compiled with by them as per the extended date of
implementation given hereinabove for that category of engines without seeking further
extension of time and (ii) a bank guarantee of Rs 10,00,000/- (Rupees ten lakhs) per
parent engine model which in case of non compliance shall stand forfeited.
Note III:- The diesel engine
1
[supplier] in the category of engines of more than 176 kW
and upto 800 kW shall, in addition to the conditions specified in Note II above, also give
an affidavit to the Central Pollution Control Board or to the respective State Pollution
Control Boards or Committees where they are located to the effect that they shall develop
either individual or a common test facility and get the same approved by the certification
agencies mentioned in paragraph 8 of serial number 95 of Schedule I.]
1
The word ‗or‘ added by Corrigendum notified vide Notification G.S.R.520(E), dated 12.8.2004 .
2
For the word ‗manufacturers‘ or ‗manufacturer‘ , the word ‗supplier‘ substituted by Rule 2 of the Environment
(Protection) Amendment Rules, 2004 notified vide Notification G.S.R.92(E), dated 29.1.2004.
The Environment (Protection) Rules, 1986 509
1
[Explanation: - For the purposes of this paragraph, ‗supplier‘ means manufacturer of
new diesel engines for genset applications in India and importer of
such diesel engines for gensets applications and diesel gensets
imported into India.]
2. Applicability
These rules shall apply to all new diesel engines for genset applications (herein after
referred to as 'engine') manufactured in India and all diesel engines for genset
applications and diesel gensets (herein after referred to as 'product'), imported into
India, after the effective date:
Provided that these rules shall not apply to:
(i) any engine manufactured or engine or product imported for the
purpose of export outside India, or;
(ii) any engine or product intended for the purpose of sample only and
not for sale in India.
3. Requirement of certification
Every manufacturer of engine or every importer of engine or product must have valid
certificates of Type. Approval and certificates of Conformity of Production for each
year, for all engine models being manufactured or for all engine or product models
being imported, after the effective date with the emission limit as specified in
paragraph 1.
4. Sale, Import or use of engine or product not complying with these rules
No person shall sell, import or use of an engine or a product which is not having a
valid Type Approval certificate and Conformity of Production certificate as per
paragraph 3.
5. Requirement of conformance labelling
(i) All the engines (individually or as part of the product) shall be clearly
engraved 'Genset Engine' on the cylinder block.
(ii) The engine or the product must be affixed with a conformance label
meeting the following requirements:-
1
Inserted by Rule 2 (ii) of the Environment (Protection) Amendment Rules, 2004 notified vide Notification
G.S.R.92(E), dated 29.1.2004.
The Environment (Protection) Rules, 1986 510
(a) the label shall be durable and legible;
(b) the label shall be affixed on a part necessary for normal operation of
the engine or the product and not normally requiring replacement
during the life of the engine or the product.
(iii) The conformance label must contain the following information:
(a) name and address of the engine manufacturer or the engine or
product importer (if the address is given in the owner's manual, it
may not be included in the label);
(b) statement that 'this engine or product conforms to the Environment
(protection) Rules, 1986‘;
(c) type approval certificate number;
(d) date of manufacture of engine or in case of import, the date of import
of the engine or the product.
6. Compliance with BIS specifications
All engines up to
1
[19 kw] (individually or as part of the product) shall carry ISI
mark and meet relevant BIS specifications (IS 10001).
7. Nodal agency
(i) The Central Pollution Control Board shall be the, nodal agency for
implementation of these rules.
(ii) In case of any dispute or difficulty in implementation of these rules
the matter shall be referred to the nodal agency.
(iii) The nodal agency shall constitute a Committee to advise it on all
matters, including the disputed matters, related to the implementation
of these rules.
8. Authorized agencies for certification
The following agencies are authorized to carry out such tests as they deem
necessary for giving certificates of Type Approval and Conformity of Production
tests for Diesel engines and to give such certificates:-
(i) Automotive Research Association of India, Pune.
(ii) Vehicle Research and Development Establishment, Ahmednagar.
1 Substituted by Rule 2(c) of the Environment (Protection) Amendment Rules, 2003 notified vide Notification
G.S.R.520(E), dated 1.7.2003.
The Environment (Protection) Rules, 1986 511
1
[(iii) International Centre for Automotive Technology, Manesar (Haryana)]
9. Compliance and testing procedure
The compliance and testing procedure shall be prepared and published by the
Central Pollution Control Board with the help of the Certification Agencies.
10. Fuel Specification
The specification of commercial fuel applicable for -diesel gensets shall be the
same as applicable for commercial HSD(High Speed Diesel) applicable for diesel
vehicles in the area, from time to time].
2
[96. EMISSION STANDARDS FOR DIESEL ENGINES (ENGINE RATING MORE
THAN 0.8 MW (800 KW) FOR POWER PLANT, GENERATOR SET
APPLICATIONS AND OTHER REQUIREMENTS
TABLE
Parameter Area
Category
Total engine rating of
the plant (includes
existing
as well as new
generator sets)
Generator sets commissioning date
Before
1.7.2003
Between
1.7.2003
and
1.7.2005
On or after
1.7.2005
NOX (as NO2) (At 15%
O2, dry basis, in ppmv
A Up to 75 MW 1100 970 710
B Up to 150 MW
A More than 75 MW 1100 710 360
B More than 150 MW
NMHC (as C) (at 15%
O2), mg/Nm
3
Both A
and B
150 100
PM (at
15% O2),
mg/Nm
3
Diesel
Fuels-
HSD &
LDO
Both A
and B
75 75
Furnace
Oils- LSHS
& FO
Both A
and B
150 100
CO (at 15% O2),
mg/Nm
3
Both A
and B
150 150
1
Inserted by Rule 2(b) of the Environment (Protection) Second Amendment Rules, 2008 notified by G.S.R.280(E), dated
11.4.2008.
2 Serial No.96 and entries relating thereto inserted by Rule 2 of the Environment (Protection) Third Amendment Rules,
2002 notified vide Notification G.S.R.489(E), dated 9.7.2002.
The Environment (Protection) Rules, 1986 512
Parameter Area
Category
Total engine rating of
the plant (includes
existing
as well as new
generator sets)
Generator sets commissioning date
Before
1.7.2003
Between
1.7.2003
and
1.7.2005
On or after
1.7.2005
Sulphur content in fuel
A <2%
B <4%
Fuel specification For A
only
Up to 5 MW Only Diesel Fuels (HSD, LDO)
shall be used.
Stack height (for
generator sets
commissioned after
1.7.2003)
Stack height shall be maximum of the following, in metre:
(i) 14 Q
0.3,
Q=Total SO2 emission from the plant in kg/hr.
(ii) Minimum 6m.above the building where generator set is installed.
(iii) 30m.
Note:
1. Acronyms used:
MW : Mega (10
6
) Watt FO : Furnace Oil
NOX : Oxides of Nitrogen HSD : High Speed Diesel
NO2 : Nitrogen Dioxide LDO : Light Diesel Oil
O2 : Oxygen LSHS : Low Sulphur Heavy Stock
NMHC : Non-Methane Hydrocarbon kPa : Kilo Pascal
C : Carbon mm : Milli (10
-3
) metre
PM : Particulate Matter kg/hr : Kilo (10
3
) gram per hour
CO : Carbon Monoxide mg/Nm
3
: Milli (10
-3
)gram per
Normal metre cubic
SO2 : Sulphur Dioxide
ppmv : Part per million(10
6
) by
volume
2. Area categories A and B are defined as follows:
Category A: Areas within the municipal limits of towns/cities having population
more than 10 lakhs and also up to 5 km beyond the municipal limits of
such towns/cities.
Category B: Areas not covered by category A.
3. The standards shall be regulated by the State Pollution Control Boards or Pollution
Control Committees, as the case may be.
The Environment (Protection) Rules, 1986 513
4. Individual units with engine ratings less than or equal to 800 KW are not covered by
this notification.
5. Only following liquid fuels viz. High Speed Diesel, Light Diesel Oil, Low Sulphur
Heavy Stock and Furnace Oil or liquid fuels with equivalent specifications shall be
used in these power plants and generator sets.
6. For expansion project, stack height of new generator sets shall be as per total Sulphur
Dioxide emission (including existing as well as additional load).
7. For multi engine plants, fuels shall be grouped in cluster to get better plume rise and
dispersion. Provision for any future expansion should be made in planning stage
itself.
8. Particulate matter, Non-Methane Hydrocarbon and Carbon Monoxide results are to
be normalized to 25
0
C, 1.01Kilo Pascal (760 mm of mercury) pressure and zero
percent moisture (dry basis).
9. Measurement shall be performed at steady load conditions of more than 85% of the
rated load.
10. Continuous monitoring of Oxides of Nitrogen shall be done by the plants whose total
engine capacity is more than 50 Mega Watt. However, minimum once in six month
monitoring for other parameters shall be adopted by the plants.
11. Following methods may be adopted for the measurement of emission parameters:-
Sl
No.
Emission
Parameters
Measurement Methods
1.
Particulates Gravimetric
2.
SO2 Barium Perchlorate – Thorin indicator method
3.
NOx Chemiluminescence, Non Dispersive Infra Red, Non
Dispersive Ultra-Violet (for continuous measurement),
Phenol disulphonic method
4.
CO Non Dispersive Infra Red
5.
O2 Paramagnetic, Electrochemical Sensor
6.
NMHC Gas Chromatograph-Flame Ionisation Detector
The Environment (Protection) Rules, 1986 514
1
[97.BOILERS USING AGRICULTURE WASTE AS FUEL
Step Grate 250 mg / Nm
3
Particulate matter
Horse Shoe/ 500 mg / Nm
3
Pulsating (12% of CO2)
Particulate matter
Spreader stroker 500 mg / Nm
3
Particulate matter
(12% of CO2);
98. GUIDELINES FOR POLLUTION CONTROL IN GINNING MILLS
Measures for Noise Control
(i) Creating separate soundproof enclosures for the fans
within the ginning area.
(ii) Keeping the fans outside the ginning room in separate
enclosures.
(iii) Roller gins may be covered by sound proof enclosures and
use of pneumatic feeding of raw cotton while suction of
ginned cotton is introduced to considerably reduce the dust
pollution level.
Measures for Dust Control
(i) The fugitive emission can be largely controlled by
employing mechanical or pneumatic handling of raw
material and ginned material through covered ducts and
providing overhead hoods connected to exhaust through
ducts and filters; use of lifting platforms for bale formers.
(ii) The overhead hoods with exhaust arrangement can be
provided at:
(a) The saw-ginning machine where manual
handling to maintain proper feeding in the
machine.
(b) At the feeding point of the roller ginning
machine when manual feeding is carried out.
(c) At the collection points of ginned cotton from
saw ginning condenser]
1
Entry 97 and 98 added by Rule 2 (iv) of the Environment (Protection) Third Amendment Rules, 2005 notified vide
Notification G.S.R. 546(E), dated 30.8.2005.
The Environment (Protection) Rules, 1986 515
1
[99. SPONGE IRON PLANT (ROTARY KILN)
A. Emission Standards*
Particulate
matter
Fuel Type Limiting value
for
concentration
Coal 100 mg/Nm
3
Gas 50 mg/Nm
3
Carbon
Monoxide
(Vol/Vol.)
Coal/gas 1%
Stack
Height**
(minimum)
Coal/gas 30.0m
Note:-
* Emission shall be normalized at 12% CO2 in
stack emission,
** Stack height shall be calculated as H=14.0 Q
0.3
where Q is emission of Sulphur Dioxide (SO2) in
kg/hr. i.e.
SO2(kg/hr) Height
(Meter)
Upto 12.68 30
12.69-33.08 40
33.09-69.06 50
69.07-127.80 60
127.81-213.63 70
(De-dusting unit) Particulate
matter (mg/m
3
)
Existing unit
100
New Unit
50
Note:-
(i) Stack attached to de-dusting unit l
have minimum height of 30.0 metre.
(ii) If, De-dusting unit is connected to
After Burner Chamber (ABC),
emission shall be emitted through
common stack (minimum height 30.0
metre) having separate arrangements
for emission monitoring for de-
dusting unit.
1
Inserted by Rule 2 (i) of the Environment (Protection) Fourth Amendment Rules, 2008 notified by G.S.R.414(E), dated
30.5.2008.
The Environment (Protection) Rules, 1986 516
(Rotary Kiln/De-
dusting unit)
B. Fugitive Emission Standards
Particulate
matter
Existing Unit New Unit
(µg/m
3
) 3000 2000
Note:-
(i) the existing industry shall comply
with a standard of 2000 (µg/m
3
) after
one year from the date of notification.
(ii) Fugitive emission shall be monitored
at a distance 10.0 metre from the
source of fugitive emission as per
following:
Area Monitoring location
Raw material
handling area
Wagon tippler, Screen area,
Transfer points, Stock bin
area
Crusher area Crushing plant, vibrating
screen, transfer points
Raw material
feed area
Feeder area, Mixing area,
Transfer Points
Cooler discharge
area
Over size discharge area,
Transfer points
Product
processing area
Intermediate stock bin area,
Screening plant, Magnetic
separation unit, Transfer
points, Over size discharge
area, Product separation area,
Bagging area
Other areas As specified by State
Pollution Control Board/
Pollution Control
Committees.
C. Effluent Standards
pH 5.5-9.0
Total suspended
solids
100mg/l
Oil & Grease 10 mg/l
Chemical oxygen
demand
250mg/l
The Environment (Protection) Rules, 1986 517
Note:-
(i) All effort shall be made to reuse and
re-circulate the water and to maintain
‗Zero discharge‘.
(ii) Stormwater drain shall be provided
within the premises of the industry so
as to avoid mixing with effluent].
1
[100. COMMON HAZARDOUS WASTE INCINERATOR
A. Emission
Limiting
concentration
in mg/Nm
3
unless stated
Sampling
Duration in
(minutes)
unless stated
Particulate Matter 50 30
HCL 50 30
SO2 200 30
CO 100 30
50 24 hours
Total Organic
Carbon
20 30
HF 4 30
NOx (NO and
NO2, expressed as
NO2
400 30
Total dioxins and
furans
0.1
ngETQ/Nm
3
8 hours
Cd+Th+their
compounds
0.05 2 hours
Hg and its
compounds
0.05 2 hours
Sb+As+Pb+Co+
Cr+Cu+Mn+Ni+
V+their
compounds
0.50 2 hours
1
Inserted by Rule 2 of the Environment (Protection) Fifth Amendment Rules, 2008 notified by G.S.R.481(E), dated
26.6.2008.
The Environment (Protection) Rules, 1986 518
Notes:
i. All monitored values shall be corrected to
11 % oxygen on dry basis.
ii. The CO2 concentration in tail gas shall not
be less than 7%.
iii. In case, halogenated organic waste is less
than 1% by weight in input waste, all the
facilities in twin chamber incinerators shall
be designed to achieve a minimum
temperature of 950
o
C in secondary
combustion chamber and with a gas
residence time in secondary combustion
chamber not less than 2 (two) seconds.
iv. In case halogenated organic waste is more
than 1% by weight in input waste, waste
shall be incinerated only in twin chamber
incinerators and all the facilities shall be
designed to achieve a minimum
temperature of 1100
o
C in secondary
combustion chamber with a gas residence
time in secondary combustion chamber not
less than 2 (two seconds).
v. Incineration plants shall be operated
(combustion chambers) with such
temperature, retention time and turbulence,
as to achieve Total Organic Carbon (TOC)
content in the slag and bottom ashes less
than 3%, or their loss on ignition is less
than 5% of the dry weight].
The Environment (Protection) Rules, 1986 519
1
[101. INCINERATOR FOR PESTICIDE INDUSTRY
A. EMISSION
Limiting
concentration
in mg/Nm
3
unless stated
Sampling
Duration in
(minutes)
unless stated
Particulate Matter 50 30
HCL 50 30
SO2 200 30
CO 100 Daily
average
Total Organic Carbon 20 30
Total Dioxins
and Furans*
Existing
Incinerator
0.2
ngTEQ/Nm
3
8 hours
New
Incinerator
0.1 8 hours
Sb+As+Pb+Cr
+Co+Cu+Mn+Ni +V+ their
compounds
1.5 2 hours
* The existing plant shall comply with norms for dioxins and
furans as 0.1 ng/TEQ/Nm
3
within a period of five years from
the date of publication of this notification.
Notes:
i. All monitored values shall be corrected to 11% oxygen on
dry basis.
ii The CO2 concentration in tail gas shall note be less than
7%.
iii. In case, halogenated organic waste is less than 1% by
weight in input waste, all the facilities in single chamber
incinerators shall be designed so as to achieve a minimum
temperature of 1100°C, in the incinerator. For fluidized
bed technology Incinerator, temperature shall be
maintained at 950°C.
1
Inserted by Rule 2 of the Environment (Protection) Seventh Amendment Rules, 2008 notified by G.S.R.600(E), dated
18.8.2008.
The Environment (Protection) Rules, 1986 520
iv. In case halogenated organic waste in more than 1% by
weight in input waste, waste shall be incinerated only in
twin chamber incinerators and all the facilities shall be
designed to achieve a minimum temperature of 1100
o
C in
secondary combustion chamber with a gas residence time
in secondary combustion chamber not less than two
seconds.
v. Scrubber meant for scrubbing emissions shall not be less
used as quencher.
vi Incineration plants shall be operated (combustion
chambers) with such temperature, retention time and
turbulence, as to achieve Total Organic Carbon (TOC)
content in the slag and bottom ashes less than 3%, and
their loss on ignition is less than 5% of the dry weight.
vii The incinerators shall have a chimney of atleast thirty
metre height.
B. Wastewater
i Wastewater (scrubber water and floor washings) shall be
discharged into receiving water conforming to the norms
prescribed under Schedule VI: General Standards for
Discharge of Environment Pollutions (Part A : Effluents)
notified under the Environment (Protection) Rules, 1986.
ii The built up in Total Dissolved Solids (TDS) in
wastewater of floor washings shall not exceed 1000 mg/l
over and above the TDS of raw water used.
1
[102. REFRACTORY INDUSTRY
A. Emission Standards
(i) Down Draft Kiln (Fuel:Coal)
Category * limiting
concentration
(mg/Nm
3
)
Particulate
matter
Small/
medium/large
350
Minimum (metres)
1
Inserted by Rule 2 of the Environment (Protection) Amendment Rules, 2009 notified by G.S.R.97(E), dated 18.2.2009.
The Environment (Protection) Rules, 1986 521
Stack height Small
Medium
Large
15
18
21
(ii) Other than Down Draft Kiln (Fuel:Coal)
Category * Limiting
concentration
(mg/Nm
3
)
Particulate
matter
Small
Medium
Large
300
200
150
Stack height
Small
Medium
Large
Minimum (metres)
15
18
21
(iii) Box, Tunnel Down Draft Kiln, etc. (Fuel:Natural
Gas/Producer Gas/LPG or a combination of
Fuels/Furnance Oil as Secondary Fuel)
Category* Limiting
concentration
(mg/Nm
3
)
Particulate
matter
Small
Medium/
Large
200
150
Stack height
Small
Medium
Large
Minimum (metres)
12
15
18
Category*
small kiln
Medium kiln
Large kiln
Production (tpa)
<15,000
15,001-50,000
above 50,000
The Environment (Protection) Rules, 1986 522
(iv) Rotary Kiln (Fuel: Furnance Oil)
Category** Limiting
concentration
(mg/Nm
3
)
Particulate
matter
Small
Medium/
Large
200
150
Stack height
Small
Medium
Large
Minimum (metres)
35
45
60
Category**
Small/rotary
kiln
medium rotary
kiln
large rotary
kiln
Production (tpd)
<50
51-100
Above 100
Note:-
(i) All values of particulate matter are to be corrected at 6 per cent Carbon
Dioxide.
(ii) Fugitive emission shall not exceed 10 mg/m
3
from any process or plant.
(iii) Each stack shall be at least 2 metre above the top most point of the
building, shed or plant in the industry excluding bucket elevator, mill
house and vibrating screen.
(iv) If more than one kiln is connected to single stack, sum of the
production capacity of all the kilns would be considered for
determining the capacity of the kiln and accordingly depending upon
the total capacity, emission standard and stack height would be
implemented.
(v) Monitoring of stack shall be carried out at the time of charging and
after the completion of charging and average of these two results shall
be considered as emission level.
The Environment (Protection) Rules, 1986 523
B. EFFLUENT STANDARDS
Limiting value for
concentration (mg/l
except for pH)
Inland Surface Water Public
Sewer
Land for
Irrigation
pH 5.5 to 9.0 5.5 to 9.0 5.5 to 9.0
Oil and Grease 10 20 10
BOD BOD 3 days, 27
o
C 30 250 100
COD 250 - -
Suspended Solids 100 600 200
Phenols 1.0 5.0 -
Cyanide as CN 0.2 2.0 0.2
Cr(Hexavalent) 0.1 2.0 1.0
Cr(Total) 2.0 2.0 2.0]
1
[103 CASHEW SEED PROCESSING INDUSTRY
A. EMISSION STANDARDS
Process Limiting
concentration in
mg/Nm
3
Roasting 250
Particulate
Matter
Cooking (roasted
shell/deoiled cake
as fuel)
150
Borma Oven
Heater (roasted
shell/deoiled cake
as fuel)
150
1
Inserted by Rule 2 of the Environment (Protection) Amendment Rules, 2010 notified vide GSR 1(E), dated 1.1.2010.
The Environment (Protection) Rules, 1986 524
Minimum (metres)
Stack height Roasting 20
Cooking 15
Borma Oven
Heater
15
Note:
All values of particulate matter shall be corrected at
4% Carbon Dioxide.
Each stack shall be at least 2 metres above the top
most point of the building, shed or plant in the
industry.
The emissions from ‗Dog-house‘ shall be channelized
alongwith Roasting-drum emissions and shall pass
through wet scrubber.
Bio-gasifier shall be installed if roasted shells are used
as fuel in the unit.
B-EFFLUENT STANDARDS
Limiting concentration in mg/l, except for pH
Inland surface
Water
Public sewer Land for Irrigation
pH 6.5 to 8.5 6.5 to 8.5 6.5 to 8.5
Oil & Grease 10 20 10
BOD3days, 27oC 30 250 100
Suspended
Solids
100 600 200
Phenols 1.0 5.0 -]
The Environment (Protection) Rules, 1986 525
1
[104 PLASTER OF PARIS INDUSTRY
A. Stack Emission Standards
Stack Production Capacity upto 30 tonnes per day (tpd)
Source Limiting
concentration in
mg/Nm
3
Particulate
Matter
Crusher 500
Calciner 500
Furnace/Grinder 150
Production capacity above 30 tpd
Particulate matter Crusher/
Calciner/ Furnace
Grinder
150
Notes:
1. The units having production capacity up to 30 tpd shall
channelize their emission through a stack or chimney of
height at least ten metres above ground level or three
metres above the top of shed or building of the industry,
whichever is more.
2. The units having production capacity above 30 tpd shall
channelize their emission through a stack or chimney of
height at least thirty metres above the ground level or
three metres above the top of shed or building whichever
is more.
B. FUGITIVE EMISSION STANDARDS (µG/M
3
)
Particulate Matter
2,000
Note: Fugitive emission shall be monitored at a distance of
10 + 1 metres from the source, irrespective of
production capacity.]
1
Inserted by Rule 2 of the Environment (Protection) Second Amendment Rules, 2010 notified vide G.S.R..61(E), dated
5.2.2010.
The Environment (Protection) Rules, 1986 526
(F. No. Q-15017/95/2000-CPW)
(R. K. VAISH)
JOINT SECRETARY TO THE GOVT. OF INDIA
Note :
The principal rules were published in the Gazette of India vide number S.O. 844(E), dated the
19
th
November, 1986 and subsequently amended vide S.O. 433(E), dated the 18
th
April, 1987,
S.O.64(E) dated the 18
th
January, 1988, S.O. 3(E) dated 3
rd
January, 1989, S.O. 190(E), dated
the 15
th
March, 1989, G.S.R. 913(E), dated the24th October, 1989, S.O. 12(E), dated the 8
th
January, 1990, G.S.R.742(E), dated the 30
th
August, 1990, S.O. 23(E), dated the16th January,
1991, G.S.R. No.93(E), dated the t21st February, 1991, G.S.R. 95(E), dated the 12
th
February,
1992, G.S.R. 329(E), dated the 13
th
March, 1992, G.S.R. 475(E), dated the 5
th
May, 1992,
G.S.R. 797 (E), dated the 1
st
October, 1992, G.S.R. 386(E), dated the 28
th
April, 1993, G.S.R.
422(E), dated the 19
th
May, 1993, G.S.R. 801(E), dated the31st December, 1993, G.S.R.
176(E), dated the 3
rd
April, 1996, G.S.R. 631(E), dated the 31
st
October, 1997, G.S.R. 504(E),
dated the 20
th
August, 1998, G.S.R.7 (E), dated the 2
nd
January, 1999, G.S.R. 682(E), dated
the 5
th
October, 1999, G.S.R.742(E), dated the 25
th
September, 2000, G.S.R. 72(E), dated the
6
th
February, 2001, G.S.R. 54(E), dated the 22
nd
January, 2002, G.S.R. 371(E), dated the 17
th
May, 2002, G.S.R. 489(E), dated the 9
th
July, 2002, S.O.1088(E), dated the 11
th
October,
2002, G.S.R. 849(E), dated the 30
th
December, 2002, G.S.R. 520(E), dated the 1
st
July, 2003,
G.S.R. 92(E), dated the 29
th
January, 2004, G.S.R.448(E), dated the 12
th
July, 2005,
Corrigenda G.S.R. 520(E), dated the 12
th
August, 2004, G.S.R.272(E), dated the 5
th
May,
2005, G.S.R.315(E), dated the 16
th
May, 2005 and G.S.R.546(E), dated 30
th
August, 2005,
G.S.R.46(E), dated the 3
rd
February, 2006, G.S.R.464(E), dated the 7
th
August, 2006,
G.S.R.640(E), dated the 16
th
October, 2006, G.S.R.566(E), dated the 29
th
August, 2007,
G.S.R.704(E), dated the 12
th
November, 2007, G.S.R.186(E), dated the 18
th
March, 2008,
G.S.R.280(E), dated the 11
th
April, 2008, G.S.R.344(E), dated the 7
th
May 2008,
G.S.R.414(E), dated the 30
th
May, 2008, G.S.R.481(E), dated the 26
th
June, 2008,
G.S.R.579(E), dated the 6
th
August, 2008, G.S.R.600(E), dated the 18
th
August, 2008,
G.S.R.752(E), dated the 24
th
October, 2008, G.S.R.97(E), dated the 18
th
February, 2009,
G.S.R.149(E), dated the 4
th
March, 2009, G.S.R.512(E), dated the 9
th
July, 2009,
G.S.R.543(E), dated the 22
nd
July, 2009, G.S.R.595(E), dated 21
st
August, 2009,
G.S.R.794(E), dated the 4
th
November, 2009, G.S.R.826(E), dated the 16
th
November, 2009
G.S.R.1(E), dated 1
st
January, 2010 and G.S.R.61(E), dated the 5
th
February, 2010.
The Environment (Protection) Rules, 1986 527
APPENDIX A
FORM I
(See rule 7)
NOTICE OF INTENTION TO HAVE SAMPLE ANALYSED
To
……………………………………………………………………………………
……………………………………………………………………………………
Take this notice that it is intended to have analysed the same of …………………
Which has been taken today, the ……………. day of …………………….19…………
from …………………………………………………………………………(Name and
designation of the person who takes the sample)
_______________________________________
*Specify the place where the sample is taken.
(SEAL)
DATE
FORM II
(See rule 8)
MEMORANDUM TO GOVERNMENT ANALYST
From
………………………………………….
………………………………………….
To
The Government Analyst
………………………………………….
………………………………………….
The portion of sample described below is sent herewith for analysis under rule 6 of the
Environment (Protection) Rules, 1986.
The portion of the sample has been marked by me with the following mark :
Details of the portion of sample taken
Name and designation of person who sends sample
Date………………. (SEAL)
The Environment (Protection) Rules, 1986 528
FORM III
(See Rule 8)
REPORT BY GOVERNMENT ANALYST
Report No. …………………..
Date . …………………………
I hereby certify that I ……………………………………………………………..
Government Analyst duly appointed under section 13 of the Environment (Protection)
Act, 1986 received on the ………………… day of ……………….. 19…………………..
from ...………………………………………………………………………………………
1
……….……………………………………………………………………………………
a sample of …………………………………………….. for analysis.
The sample was in a condition fit for analysis as reported below :
I further certify that I have analysed the aforementioned sample on ……………
…………………… and declare the result of the analysis to be as follows :
2……………………………………………………………………………………
………………………………………………………………………………………………
The Condition of seals, fastening of sample on receipt was as follows :
………………………………………………………………………………………………
………………………………………………………………………………………………
Signed this ……………………………………….day of …...……………………………..
19……………………………..
Signature
Address………………………
(Government Analyst)
………………………………………
………………………………………
………………………………………
1
Here write the name of the officer/authority from whom sample was obtained.
2 Here write full details of analysis and refer to method of analysis.
The Environment (Protection) Rules, 1986 529
FORM IV
(See rule 11)
FORM OF NOTICE
By registered post
acknowledgement due
From (1)
Shri ……………………………
…………………………………
…………………………………
To
…………………………………
…………………………………
…………………………………
Notice under section 19(b) of Environment (Protection) Act, 1986
Whereas an offence under the Environment (Protection) Act, 1986 has been
committed/ is being committed by …………………………………………………………
(2) I/we hereby give notice of 60 days under section 19(b) of the Environment
(Protection) Act, 1986 of my/our intention to file a complaint in the court against
…………………………………………………………(2) for violation of section of the
Environment (Protection) Act, 1986.
In support of my/our notice, I am /we are enclosed the following documents(3) as
evidence of proof of the Environment (Protection) Act, 1986.
Signature(s)
Place…………………….
Dated ……………………
Explanation :
(1) In case the notice is given in the name of a Company, documentary evidence
authorising the persons to sign the notice on behalf of the company shall be
enclosed to this notice.
Company for this purpose means a company defined in explanation to sub-
rule(6) of rule 4.
(2) Here give the name and address of the alleged offender. In case of a
manufacturing/processing/operation unit, indicate the name/location/nature of
activity etc.
(3) Documentary evidence shall include photograph/ technical reports/ health report
of the area, etc. for enabling enquiry into the alleged violation/ offence.
[No. 1(18)/86-PL]
T.N. SESHAN, Secy.
The Environment (Protection) Rules, 1986 530
1
[FORM-V]
(See rule 14)
Environmental statement for the financial year ending the 31
st
March ………..
PART-A
(i) Name and address of the owner/occupier of the industry operation or process
(ii) Industry category Primary – (STC Code) Secondary – (SIC Code)
(iii) Production capacity – Units ----------
(iv) Year of Establishment
(v) Date of last environmental statement submitted
PART-B
Water and Raw Material Consumption
(i) Water consumption m3/d
Process
Cooling
Domestic
Name of Products Process water consumption per unit of product output.
During the previous
financial year
During the current
financial year
(1) (2)
(1)
(2)
(3)
1 Substituted by Rule 2(b) of Environment (Protection) Amendment Rules, 1993 notified vide G.S.R. 386 (E) dated
22.04.1993.
The Environment (Protection) Rules, 1986 531
(ii) Raw material consumption
*Name of raw
materials
Name of Products Consumption of raw material per unit of output
During the previous
financial year
During the current
financial year
* Industry may use codes if disclosing details of raw material would violate contractual
obligations, otherwise all industries have to name the raw materials used.
PART-C
Pollution discharged to environment/unit of output
(Parameter as specified in the consent issued)
(1) Pollutants Quality of
Pollutants
discharged
(mass/day)
Concentrations of
pollutants
discharges
(Mass/volume)
Percentage of
variation from
prescribed standards
with reasons.
(a) Water
(b) Air
PART-D
HAZARDOUS WASTES
(As specified under
1
[Hazardous Wastes (Management, Handling and Transboundry
Movement) Rules, 2008)]
Hazardous Wastes Total Quantity (Kg.)
During the previous
financial year
During the current
financial year
(a) From process
(b) From pollution control facilities
1
The Hazardous Wastes (Management, Handling and Transboundary Movement) Rules, 2008 notified vide S.O.2265(E),
dated 24.9.2008.
The Environment (Protection) Rules, 1986 532
PART-E
Solid Wastes
Total Quantity
During the previous
financial year
During the current
financial year
(a) From process
(b) From pollution control facilities
(c) (1) Quantity recycled or re-utilized within the unit.
(2) Sold
(3) Disposed
PART-F
Please specify the characterizations (in terms of composition of quantum) of
hazardous as well as solid wastes and indicate disposal practice adopted for both these
categories of wastes.
PART-G
Impact of the pollution abatement measures taken on conservation of natural
resources and on the cost of production.
PART-H
Additional measures/investment proposal for environmental protection including
abatement of pollution, prevention of pollution.
PART-I
Any other particulars for improving the quality of the environment.
[F.No. Q-15015/1/90-CPA]
MUKUL SANWAL, Jt. Secy.
The Environment (Protection) Rules, 1986 533
1
[SCHEDULE II]
(See rule 3)
General standards for discharge of effluents
Sl.
No.
Parameter Standards
Inland surface
water
Public
sewers
Land for
irrigation
Marine coastal areas
(a) (b) (c) (d)
1. Colour and odour See Note 1 - See Note 1 See Note 1
2. Suspended solids, mg/l, Max 100 600 200 (a) For process waste
water-100
(b) For cooling water
effluent-10 per cent
above total
suspended matter of
influent cooling
water.
3. Particle size of suspended
solids
Shall pass 850
micron IS Sieve
(a) Floatable solids,Max
3 mm
(b) Settleable solids Max
850 microns.
4. Dissolved Solids (inorganic),
mg/a, max.
2100 2100 2100
5. PH value 5.5 to 9.0 5.5 to 9.0 5.5 to 9.0 5.5 to 9.0
6. Temperature 0 oC, Max Shall not exceed
40 in any section
of the stream
within 15 meters
down stream
from the effluent
outlet
45 at the
point of
discharge
- 45 at the point of
discharge.
7. Oil and grease, mg/l max. 10 20 10 20
8. Total residual chlorine, mg/l,
Max.
1.0 - - 1.0
9. Ammonical nitrogen (as N),
mg/l, Max.
50 50 - 50
10. Total kjeldahl nitrogen (as N),
mg/l, Max.
100 - - 100
11. Free Ammonia (as NH3), Mg/l,
Max.
5.0 - - 5.0
12. Biochemical Oxygen Demand
2[3 days at 27C] Max.
30 350 100 100
1
Schedule II inserted vide G.S.R. 919(E) dt. 12.9.88, published in the Gazette no. 488 dt. 12.9.88 and omitted by
G.S.R.801(E), dated 31.12.1993.
2
Substituted by Rule2 of the Environment (Protection) Amendment Rules, 1996 notified by G.S.R.176, dated 2.4.1996
may be read as BOD (3 days at 27oC) wherever BOD 5 days 20oC occurred.
The Environment (Protection) Rules, 1986 534
13. Chemical Oxygen Demand,
mg/l Max.
250 - - 250
14. Arsenic (as As), mg/l, Max. 0.2 0.2 0.2 0.2
15. Mercury (As Hg), Mg/l Max. 0.01 0.01 - 0.01
16. Lead (as Pb), Mg/l, Max. 0.1 1.0 - 1.0
17. Cadmium (as Cd) Mg/l,Max. 2.0 1.0 - 2.0
18. Hexavalent chromium (as
Cr+6) mg/l, Max.
0.1 2.0 - 1.0
19. Total chromium (as Cr), mg/l,
Max.
2.0 2.0 - 2.0
20. Copper (As Cu) mg/l, Max. 3.0 3.0 - 3.0
21. Zinc. (as Zn), mg/l, Max. 5.0 15 - 15
22. Selenium (as Se), mg/l, Max. 0.05 0.05 - 0.05
23. Nickel (as Ni), mg/l, Max 3.0 3.0 - 5.0
24. Boron (as B), mg/l, Max 2.0 2.0 2.0 -
Previous and next
Questions people ask
Is rule 18 of THE ENVIRONMENT (PROTECTION) RULES, 1986 still in force?
Rule 18 of THE ENVIRONMENT (PROTECTION) RULES, 1986 is omitted.