LawGrids logoLAWGRIDS.ORG

Rule 18, THE ENVIRONMENT (PROTECTION) RULES, 1986: OMITTED

THE ENVIRONMENT (PROTECTION) RULES, 1986 - Rule 18 - Omitted

Omitted

This rule is omitted.

Text of rule 18

OMITTED

[18. OMITTED 19. CALCIUM CARBIDE Particulate Matter Emission - Kiln 250 milligramme per normal cubic metre. - Arc Furnace 150 milligramme per normal cubic metre. 20. CARBON BLACK Particulate matter Emission 150 milligramme per normal cubic metre. 21. COPPER, LEAD AND ZINC SMELTING Particulate Matter Emission in Concentrator 150 milligramme per normal cubic metre. Emission of Oxides of Sulphur in Smelter & convertor Off-gases must be utilized for sulphuric acid manufacture. The limits of sulphur dioxide emission from stock shall not exceed 4 kilogramme per tonne of concentrated (one hundred per cent acide produced). 22. NITRIC ACID (EMISSION OXIDES OF NITROGEN) Emission of Oxides of Nitrogen 3 kilogramme of oxides of nitrogen per tonne of weak acid (before concentration) produced. 2 [23. SULPHURIC ACID PLANT Emission standards Limiting concentration in mg/Nm 3 , unless stated Plant capacity for 100% concentration of Sulphuric Acid (tonne/day) 1 Sr. No.18 relating to “Aluminum” and entries relating thereto omitted by Rule 2(II) of the Environment (Protection) First Amendment Rules, 2006 notified by G.S.R. 46(E), dated 3.2.2006. 2 Substituted by Rule 2(I) of the Environment (Protection) Third Amendment Rules, 2008 notified by G.S.R. 344(E), dated 7.5.2008. The Environment (Protection) Rules, 1986 424 Sr. No. Industry Parameter Standards 1 2 3 4 Existing Unit New Unit Sulphur dioxide (SO2) upto 300 1370 1250 Above 300 1250 950 Acid Mist/Sulphur Up to 300 90 70 Trioxide Above 300 70 50 Note: (i) Scrubbing units shall have on-line pH meters with auto recording facility. (ii) The height of the stack emitting sulphur-dioxide or acid mist shall be of minimum of 30 metre or as per the formula H=14(Q) (0.3) (whichever is more). Where ―H‖ is the height of stack in metre; and ―Q‘ is the maximum quantity of SO2 expected to be emitted through the stack at 110 per cent rated capacity of the plants and calculated as per the norms of gaseous emission. (iii) Plants having more than one stream or unit of sulphuric acid at one location, the combined capacity of all the streams and units shall be taken into consideration for determining the stack height and applicability of emission standards. (iv) Plants having separate stack for gaseous emission for the scrubbing unit, the height of this stack shall be equal to main stack]. 24. IRON & STEEL (INTEGRATED) Particulate Matter Emission - Sintering Plant 150 milligramme per normal cubic metre - Steel making -- during normal operations 150 milligramme per normal cubic metre. --during oxygen lancing 400 milligramme per normal cubic metre. - Rolling Mill 150 milligramme per normal cubic metre. - Carbon monoxide from coke oven 3 kilogramme per tonne of coke produced. The Environment (Protection) Rules, 1986 425 Sr. No. Industry Parameter Standards 1 2 3 4 1 25. THERMAL POWER PLANTS  Particulate Matter Emissions : - generation cpacity 210 MW or more 150 millogramme per normal cubic metre. - generation capacity less than 210 MW 350 milligramme per normal cubic metre. 26. NATURAL RUBBER INDUSTRY Concentrations in the effluents not to exceed milligramme per litre (except for pH) 44 o C - Discharge into inland surface water Colour & odour Absent pH 6.0 – 9.0 BOD 50 COD 250 Oil and Grease 10 Sulphides 2 Total Kjeldahl Nitrogen 100 Dissolved phosphate (as P) 5 Suspended Solids 100 Dissolved solids (inorganic) 2100 Ammonical Nitrogen as N 50 Free ammonia (as NH3) 5 -Disposal on land for irrigation Colour and Odour Absent pH 6.0 – 8.0 BOD 100 COD 250 Oil & Grease 10 Suspended Solids 200 Dissolved solids 2100 1 S. No. 25 and 26 and entries relating thereto inserted vide S.O. 8(E) dt. 3.1.89 published in the Gazette No. 7 dated. 3.1.89. Corrections in rule 2 against S.No. 26 made vide corrigendum No. S.O. 190 (E) dt. 15.3.89 published in the Gazette no. 126 dt. 15.3.89.  Depending upon the requirement of local situation, such as protected area, the State Pollution Control Board and other implementation agencies under the Environment (Protection) Act, 1986 may prescribed a limit of 150 milligramme per normal cubic meter, irrespective of generation capacity of the plant. The Environment (Protection) Rules, 1986 426 Sr. No. Industry Parameter Standards 1 2 3 4 1 [ 2 27. ASBESTOS MANUFACTURING UNITS (INCLUDING ALL PROCESSES INVOLVING THE USE OF ASBESTOS) - Pure Asbestos material 0.5 fibre */cc for one year from the date of notification 0.2 fibre */cc after one year from the date of notification] - Total Dust 2 mg/m 3 (normal) 28. CALOR ALKALI (CAUSTIC SODA) EMISSIONS Concentration in mg/m 3 (normal) (a) Mercury Cell Mercury (from hydrogen gas holder stack) 0.2 (b) All processes Chlorine (from hypo tower) 15.0 (c) All processes Hydro chloric acid vapours and mist (from hydro chloric acid plant) 35.0 29. LARGE PULP AND PAPER EMISSIONS Concentration in mg/m 3 (normal) Particulate matter 250 ** H2S 10 30. INTEGRATED IRON AND STEEL PLANTS: I. EMISSIONS (a) Coke Oven Particulate mater 50 (b) Refractory material plant Particulate matter 150 II. EFFLUENTS Concentration in mg/l except for pH. (a) Coke oven By product plant. pH 6.0 – 8.0 Suspended Solids 100 1 Standards mentioned at Sl. No.27 amended by Rule 2(III) of the Environment (Protection) First Amendment Rules, 2006 notified vide Notification G.S.R.46(E), dated 3.2.2006. 2 S.No. 27 to 31 and entries relating thereto inserted vide GSR 913(E) dt. 24.10.89 published in the Gazette No. 554 dt. 24.10.89. ** This standard of 250 mg/m3 (normal) shall apply only for a period of 3 years with effect from the date on which the Environment (protection) Second Amendment Rules, 1989 came into force. After three years the standard to be applicable is 15 mg/m3 (normal). The Environment (Protection) Rules, 1986 427 Sr. No. Industry Parameter Standards 1 2 3 4 Phenol 1.0 Cynide 0.2 BOD 1 [(3 days at 27 o C)] 30 COD 250 Ammonical Nitrogen 50 Oil and Grease 10 (b)Other plants such as sintering plant, blast furnace, steel melting and rolling mill: pH 6.0 – 9.0 Suspended Solids 100 Oil and Grease 10 31. RE-HEATING (REVERBERATORY) FURNACES: EMISSIONS Concentration in mg/m 3 (normal) Capacity : All sizes Sensitive area Particulate matter 150 Other area Particulate matter 450 2 [32. FOUNDRIES EMISSIONS (a) Cupola Capacity (Melting Rate) : Less than 3 mt./hr. Particulate Matter 450 3 mt/hr. and above Particulate Matter 150 Note : It is essential that stack is constructed over the cupola beyond the charging door and emissions are directed through the stack which should be at least six times the diameter of cupola. (b) Arc Furnaces : Capacity: All sizes Particulate Matter 150 1 Substituted by Rule 2 of the Environment (Protection) Amendment Rules, 1996 notified by G.S.R.176(E), dated 2.4.1996 may be read as BOD (3 days at 27oC) wherever BOD 5 days 20oC occurred 2 S.No. 32 to 47 and entries relating thereon inserted vide GSR 742(E) dt. 30.8.90 published in the Gazette No. 365 dated 30.8.90. The Environment (Protection) Rules, 1986 428 Sr. No. Industry Parameter Standards 1 2 3 4 (c) Induction Furnace Capacity: All sizes Particulate Matter 150 Note : In respect of Arc Furnaces and Induction Furnaces provision has to be made for collecting the fumes before discharging the emissions through the stack. 33. THERMAL POWER PLANTS STACK HEIGHT/LIMIT IN METERS * Power generation capacity : - 500 MW and above 275 - 200 MW/210 MW and above to less than 500 MW 220 - Less than 200 MW/210 MW H-14(Q) 0.3 where Q is emission rate of SO2 in *kg/hr. and *H Stack height in metres. Steam generation capacity: - Less than 2 ton/hr. ½ times the neighbouring building height or 9 metres (whichever is more) - More than 2 ton/hr. to 5 ton/hr. 12 - More than 5 ton/hr. to 10 ton/hr. 15 - More than 10 ton./hr. 18 - More than 15 ton/hr. to 20 ton/hr. *21 - More than 20 ton/hr. to 25 ton/hr 24 - More than 25 ton/hr. to 30 ton/hr. 27 - More than 30 ton/hr. 30 or using formula H- 14(Q) 0.3 (whichever is more) Q is emission rate of SO2 in kg/hr and *H-Stack height in meters. * Correction have been made as per Corrigendum Notification no. S.O. 8(E) dt. 31.12.1990. The Environment (Protection) Rules, 1986 429 Sr. No. Industry Parameter Standards 1 2 3 4 34. SMALL BOILERS EMISSIONS * Capacity of Boiler Particulate matter - Less than 2 ton/hr. - 2 to 5 ton/hr More than 15 ton/hr. 1600 1200 150 1 [ 2 35. COFFEE INDUSTRY Instant/Dry Processing Limiting value for concentration in mg/l except for pH pH 6.5-8.5 BOD 3 day, 27 o C 100 Total Dissolved Solids 2100 Wet/Parchment Coffee Processing pH 6.5-8.5 BOD 3 day, 27 o C 1000 Notes: (i) Coffee growers having plantation area less than 10 ha with wet processing shall store primary treated effluent in lined lagoons for solar evaporation with a non-permeable system at the base and sides of lagoon. (ii) Coffee growers having plantation area between 10-25 ha with wet processing shall store primary (equalization and neutralization) treated effluent in lined lagoons for solar evaporation with a non-permeable system at the base and sides of lagoon. (iii) Coffee growers having plantation area 25 ha or above with wet processing shall store secondary treated effluent in conformity with above norms in lined lagoons with a non-permeable lining system at the base and side of lagoon and use the effluent for irrigation after dilution so as BOD of diluted effluent for land application is less than 100 mg/l. (iv) The minimum liner specifications for a non-permeably lining system shall be a composite barrier having 1.5 mm High Density Polyethylene (HDPE) geomembrane or equivalent, overlying 90 cm of soil (clay or amended soil) having permeability coefficient not more than 1x10- 5 cm/sec. (v) The effluent storage facilities/lagoons/solar evaporation ponds shall be located above high flood level mark of the nearby stream, rivulet etc. with below mentioned free board and away from any water body/stream at a distance. * All emissions normalized to 12 per cent carbon dioxide. 1 Omitted entry relating to Oil Refineries (Sulphur Dioxide) by Rule 2 (i) (b) of the Environment (Protection) Amendment Rules, 2008 notified by G.S.R. 186 (E), dated 18.3.2008. 2 Inserted by Rule 2 of the Environment (Protection) Sixth Amendment Rules, 2008 notified by G.S.R.579(E), dated 6.8.2008 The Environment (Protection) Rules, 1986 430 Sr. No. Industry Parameter Standards 1 2 3 4 Grower Small (<10ha) Medium (10-25ha) Large (>25ha) Free Based (cm) 30 60 90 Distance (m) 50 100 150 (vi) Raw, Treated and/or diluted effluent shall be discharged into surface water body or used for recharging groundwater under any circumstances what so ever]. 36. ALUMINIUM PLANTS: EMISSIONS (a) Aluminia Plant: (i) Raw Material Handling Primary and Secondary Crusher Particulate Matter 150 (ii) Precipitation Area - Calcination Particulate matter 250 Carbon Monoxide 1% max. Stack Height H=14 (Q) 0.3 Where Q is emission rate of SO2 in kg/hr and H-Stack height in meters. (b)Smelter Plant Particulate Matter (i)Green Anode Shop Particulate Matter 150 1 [(ii)Anode Bake Oven Particulate Matter 50 mg/Nm 3 Total Fluoride (F) 0.3 kg/MT of Aluminium. (iii)Pot room Particulate matter 150 Total Fluoride For Soderberg* Technology 2.8 Kg/ton by 31 st December 2006 For Pre-baked Technology 0.8 kg/t by 31 st December 2006 1 Substituted by Rule 2(iv) (a) amended by Rule 2 (IV) (a) of the Environment (Protection) First Amendment Rules, 2006 notified vide Notification G.S.R.46(E), dated 3.2.2006. The Environment (Protection) Rules, 1986 431 Sr. No. Industry Parameter Standards 1 2 3 4 * Separate standards for VSS, HSS, PBSW & PBCW as given in column 4 stands abolished 1 [(c) Standards for forage fluoride - Twelve consecutive months average - 40 ppm - Two consecutive months average - 60 ppm - One month average - 80 ppm] * 37. STONE CRUSHING UNIT Suspended Particulate Matter (SPM) The Standards consist of two paras : (i) Implementation of the following Pollution Control measures: (a) Dust containment cum suppression system for the equipment. (b) Construction of wind breaking walls. (c) Construction of the metalled roads within the premises. (d) Regular cleaning and wetting of the ground within the premises. (e) Growing of a green belt along the periphery. 1 Inserted by Rule 2(IV)(b) of the Environment (Protection) First Amendment Rules, 2006 notified by G.S.R.46(E), dated 3.2.2006. * Standards notified at Sl. No. 11 may also be referred. The Environment (Protection) Rules, 1986 432 Sr. No. Industry Parameter Standards 1 2 3 4 (ii) Quantitative standard for SPM : ** [measured between three meters and ten metres from any processes equipment of a stone crushing unit shall not exceed 600 microgrammes per cubic metre] from a controlled isolated as well as from a unit located in a cluster should be less than 600 mg/Nm3 1 [xxx….] 38. PETROCHEMICALS (BASIC & INTERMEDIATES) EFFLUENTS Ph 6.5 – 8.5 *BOD 2 [(3days at 27 o C)] 50 **Phenol 5 Sulphide (as S) 2 COD Cynide (as CN) 250 *** Fluoride (as F) Total suspended Solids 3 [100] Hexavalent Chromium 3 [(as Cr)] 0.1 **** Total Chromium 3 [(as Cr)] 2.0 ** Corrections have been made as per CORRIGENDUM Notification No. S.O. 8(E) dated 31.12.1990. 1 The sentence ‗The measurements are to be conducted at least twice a month for all the 12 month in a year‘ deleted as per CORRIGENDUM Notification S.O 8(E) dated 31.12.90. 2 Substituted by Rule 2 of the Environment (Protection) Amendment Rules, 1996 notified by G.S.R.176(E), dated 2.4.1996 may be read as BOD (3 days at 27oC) wherever BOD 5 days 20oC occurred. 3 Corrected as per CORRIGENDUM Notification S.O. 8(E) dated 31.12.1990. The Environment (Protection) Rules, 1986 433 Sr. No. Industry Parameter Standards 1 2 3 4 * State Board may prescribed the BOD value of 30 mg/l if the recipient system so demands. ** The limit for phenol shall be conformed to at the outlet of effluent treatment of phenol plant. However, at the final disposal point, the limit shall be less than 1 mg/l. *** The limit for fluoride shall be confirmed to at the outlet of the chrome removal unit. However, at the disposal point fluoride concentration shall be lower than 5mg/l. **** The limits for total and hexavalent chromium shall be conformed to at the outlet of the chromate removal. This implies that in the final treated effluent, total and hexavalent chromium shall be lower than prescribed herein. 1 [ 2 39 HOTEL INDUSTRY EFFLUENT STANDARDS (i)Hotel with atleast 20 bedrooms limiting concentration in mg/1, except for pH Inland Surface Water On land for Irrigation PH 5.5-9.0 5.5-9.0 BOD3 days, 27 o C 30 100 Total Suspended Solids 50 100 Oil & Grease 10 10 Phosphate as P 1.0 - (ii)Hotel with less than 20 bedrooms or a Banquet Hall with minimum floor area of 100m 2 or a Restaurant with minimum seating capacity of 36 pH 5.5-9.0 5.5-9.0 BOD3 days, 27 o C 100 100 Total Suspended Solids 100 100 Oil & Grease 10 10 1 Omitted entry relating to Pharmaceutical Manufacturing and Formulation Industry by Rule 2(a) of the Environment (Protection) Third Amendment Rules, 2009 notified by G.S.R.512(E), dated 9.7.2009. 2 Inserted by Rule of the Environment (Protection) Sixth Amendment Rules, 2009 notified by G.S.R.794(E), dated 4.11.2009. The Environment (Protection) Rules, 1986 434 Sr. No. Industry Parameter Standards 1 2 3 4 Notes: i. Hotels, banquet halls, restaurants, etc. located in coastal area shall also comply with the provisions of the Coastal Regulation Zone, as applicable. ii If, the effluent is discharged into a municipal sewer leading to a Sewage Treatment Plant, the hotel or restaurant or banquet hall, as the case may be, shall provide a proper Oil and Grease Trap for effluent arising from its kitchen and laundry and shall have to comply with the 'General Standards for Discharge of Environmental Pollutants Part-A: Effluents' notified under Schedule-VI]. 40. PESTICIDE MANUFACTURING AND FORMULATION INDUSTRY. EFFLUENTS 1. Temperature Shall not exceed 5 o C above the receiving water temperature 2. pH 6.5 – 8.5 3. Oil and Grease 10 4. BOD 1 [(3 days at 27 o C)] 30 5. Total Suspended Solids 100 6. Bio-assay test 90% survival of fish after 96 hours in 100% effluent. 7. (a) Specific Pesticides : Benzenl Hexachloride 10 Carbonyl 10 DDT 10 Endosulfan 10 Diamethoate 450 Fenitrothion 10 Malathion 10 1 Substituted by Rule 2 of the Environment (Protection) Amendment Rules, 1996 notified by G.S.R.176(E), dated 2.4.1996 may be read as BOD (3 days at 27oC) wherever BOD 5 days 20oC occurred. The Environment (Protection) Rules, 1986 435 Sr. No. Industry Parameter Standards 1 2 3 4 Phorate 10 Methyl Parathion 10 Phenathoate 10 Pyrethrums 10 Copper Oxyghloride 9600 Copper Sulphate 50 Ziram 1000 Sulphur 30 Paraquat 2300 Proponil 7300 Nitrogen 780 (b) Heavy Metals Copper 1.00 Managanese 1.00 Zinc 1.00 Mercury 0.01 Tin 0.10 Any other metal like Nickel etc. Shall not exceed 5 times the drinking water standards of BIS. (c) Organics Phenol and Phenolic compounds as C6H5OH 1.0 (d) Inorganics Arsenics (As As) 0.2 Cyanide (as CN) 0.2 Nitrate (as NO3) 50.0 Phosphate (as P) 5.0 The Environment (Protection) Rules, 1986 436 Sr. No. Industry Parameter Standards 1 2 3 4 1 [EMISSIONS Not to exceed mg/Nm 3 HCl 20 Cl2 5 H2S 5 P2O5 (as H3PO4) 10 NH3 30 Particulate matter with pesticides compounds 20 CH3Cl 20 HBr 5] Note : 1. Limits should be complied with the end of the treatment plant before any dilution. 2. Bio-assay test should be carried out with available species of fish in receiving water. 3. State Boards may prescribe limits of total dissolved solids (TDS) sulphates and chlorides depending on the uses of recipient water body. 4. State Board may prescribe COD limit correlated with BOD limit. 5. Pesticides are known to have metabolites and isomers. If they are found insignificant concentration, standards may be prescribed for those in the list by Central or State Board. 6. Industries are required to analyse pesticides in waste water by advanced analytical method such as GLC/HPLC. 7. All the parameters will be compulsory for formulators, for others, the 7 th will be optional. 1 Inserted entries relating to emissions by Rule 2(V) of the Environment (Protection) First Amendment Rules, 2006 notified vide G.S.R.46(E), dated 3.2.2006. The Environment (Protection) Rules, 1986 437 Sr. No. Industry Parameter Standards 1 2 3 4 41. TANNERY (AFTER PRIMARY TREATMENT) Disposal : Channel/ conduit Carrying waste waters to Secondary Treatment Plants Type of Tanners : EFFLUENT - chrome tanneries/ combined chrome & Vegetable tanneries. pH 6.5 – 9.0 SS Not to exceed 600 Chromium Concentration after treatment in the chrome waste water stream 45 - Vegetable tanneries pH 6.5 – 9.0 SS Not to exceed 600 Note : The above standards will apply to those tannery units which have made full contribution to a Common Effluent Treatment Plant (CETP) Comprising secondary treatment. Those who have not contributed will be governed by earlier Notification No. S.O. * 61 (E), dated January 18, 1988. 42. PAINT INDUSTRY WASTE WATER DISCHARGE EFFLUENTS pH 6.0 – 8.5 Suspended Solids 100 BOD5 1 [(3 days at 27 o C)] 50 Phenolics as C6H5OH 1.0 Oil and Grease 10.0 Bio-assay test 90% survival in 96 hours Lead as Pb 0.1 * Corrected as per Notification No. S.O. 8(E) dated 31.12.1990. 1 Substituted by Rule 2 of the Environment (Protection) Amendment Rules, 1996 notified by G.S.R.176(E), dated 2.4.1996 may be read as BOD (3 days at 27oC) wherever BOD 5 days 20oC occurred The Environment (Protection) Rules, 1986 438 Sr. No. Industry Parameter Standards 1 2 3 4 Chromium as Cr Hexavalent 0.1 Total 2.0 Copper as Cu 2.0 Nickle as Ni 2.0 Zinc as Zn 5.0 Total heavy metals 7.0 43. INORGANIC CHEMICAL INDUSTRY (WASTE WATER DISCHARGE) EFFLUENTS part I (metal compounds of Chromium, Manganese, Nickel, Copper, Zinc, Cadmium, Lead and Mercury) pH 6.0 – 8.5 Chromium as Cr Hexavalent 0.1 Total 2.0 Manganese as Mn 2.0 Nickel as Ni 2.0 Copper as Cu 2.0 Zinc as Zn 5.0 Cadmium as Cd 0.2 Lead as Pb 0.1 Mercury as Hg .01 Cynide as CN 0.2 Oil & Grease 10.0 Suspended Solids 30.0 In addition to the above, total heavy metals are to be limited to 7 mg/l. The Environment (Protection) Rules, 1986 439 Sr. No. Industry Parameter Standards 1 2 3 4 44. BULLION REFINING (WASTE WATER DISCHARGE) EFFLUENTS pH 6.5 – 8.5 Cynide as CN 0.2 Sulphide as S 0.2 Nitrate as N 10.0 Free C12 as C1 1.0 Zinc as Zn 5.0 Copper as Cu 2.0 Nickel as Ni 2.0 Arsenic as As 0.1 Cadmium as Cd 0.2 Oil and Grease 10.0 Suspended Solids 100 * 45. DYE & DYE INTERMEDIATE INDUSTRY (WASTE WATER DISCHARGE) EFFLUENTS pH 6.0 – 8.5 Colour Hazen Unit 400.0 Suspended Solids 100.0 BOD 1 [(3 days at 27 o C)] 100.0 Oil and Grease 10.0 Phenolics as C6H5OH 1.00 Cadmium as Cd 0.2 Copper as Cu 2.0 Manganese as Mn 2.0 Lead as Pb 0.1 Mercury as Hg 0.01 Nickel as Ni 2.0 Zinc as Zn 5.0 Chromium as Cr 6+ 0.1 Total Chromium 2.0 Bio-assay test 90% survival in 96 hours. * Standards Notified as Sl. No. 8 may also be referred. 1 Substituted by Rule2 of the Environment (Protection) Amendment Rules, 1996 notified by G.S.R.176(E), dated 2.4.1996 may be read as BOD (3 days at 27oC) wherever BOD 5 days 20oC occurred The Environment (Protection) Rules, 1986 440 Sl.No. Category Standards dB(A) 1 2 3 46. NOISE LIMITS FOR AUTOMOBILES (FREE FIELD) AT ONE METER IN dB(A) AT THE MANUFACTURING STAGE TO BE ACHIEVED BY THE YEAR 1992. (a) Motorcycle, Scooters & Three wheelers 80 (b) Passenger Cars 82 (c) Passenger or Commercial Vehicles upto 4 MT 85 (d) Passenger or Commercial Vehicles above 4 MT and upto 12 MT 89 (e) Passenger or Commercial Vehicles exceeding 12 MT 91 47. DOMESTIC APPLIANCES AND CONSTRUCTION EQUIPMENTS AT THE MANUFACTURING STAGE TO BE ACHIEVED BY THE YEAR, 1993 (a) Window Air Conditioner of 1 ton to 1.5 tons 68 (b) Air Coolers 60 (c) Refrigerators 46 1 [(d) ***……… - ] (e) Compactors (rollers) Front loaders, Concrete mixers, Cranes (movable), Vibrators and Saws. 75 1 The words and figures ‗Diesel generators for domestic purposes … 85-90‘ omitted by Rule 2(a) of the Environment (Protection) Second Amendments Rules, 2002 published vide Notification No.G.S.R.371(E), dated 17.5.2005 The Environment (Protection) Rules, 1986 441 Sr. No. Industry Parameter Standards 1 2 3 4 1 48. GLASS INDUSTRY EMISSIONS A. Sodalime & Borosilicate and other special Glass (other than Lead) (a) Furnace : Capacity (i) Upto a product draw capacity of 60 MT/Day Particulate Matter 2.0 kg/hr. (ii) Product draw capacity more than 6 MT/Day Particulate Matter 0.8 kg/MT of product drawn (iii) For all capacities Stack height H=14(Q) 0.3 where Q is the emission rate of SO2 in Kg/hr. & H is Stack height in meters. Total Fluorides 5.0 mg/NM 3 Nox Use of low Nox burners in new plants (b) Implementation of the following measures for fugitive emission control from other sections : (i) Raw materials should be transported in leak proof containers. (ii) Cullet preparation should be dustfree using water spraying. (iii) Batch preparation section should be covered. B. Lead Glass (a) Furnaces : All capacities Particulate Matter 50 mg/NM 3 Lead 20 mg/NM 3 (b) Implementation of the following measures for fugitive emission control from other sections: (i) Batch mixing, proportioning section and transfer points should be covered and it should be connected to control equipments to meet the following standards : Particulate matter 50 mg/NM 3 Lead 20 mg/NM 3 (ii) Minimum Stack height should be 30 metres in lead glass units. (c) Pot furnace at Firozabad Furnace : Particulate matter 1200 mg/NM 3 Note : Depending upon local environmental conditions, State/Central Pollution Control Board can prescribe more stringent standards than those prescribed above. 1 S.No. 48 to 55 and entries relating thereto inserted vide GSR 93(E) dt. 21.2.91 published in the Gazette No. 79 dated 27.2.91. The Environment (Protection) Rules, 1986 442 Sr. No. Industry Parameter Standards 1 2 3 4 Glass Industries (for all categories) EFFLUENTS: pH 6.5 – 8.5 Total Suspended Solids 100 mg/l Oil & Grease 10 mg/l 49. LIME KILN Stack Height Capacity : Upto 5 T/day Stack Height A hood should be provided with a stack of 30 meter height from ground level (including kiln height). Above 5T/day Stack height H=14(Q) 0.3 where Q is emission rate of SO2 in kg/hr and H=Stack Height in meters. More than 5T/day and up to 40 T/Day Particulate matter 500 mg/Nm 3 Above 40T/day Particulate matter 150 mg/Nm 3 50.  SLAUGHTER HOUSE, MEAT & SEA FOOD INDUSTRY EFFLUENTS Concentration in mg/l Category A.Slaughter House (a) Above 70 TLWK/day BOD 1 [3 days at 27 o C] 100 Suspended Solids 100 Oil and Grease 10 (b) 70 TLWK/day below BOD 1 [3 days at 27 o C] 500 B.Meat Processing (a) Frozen Meat BOD 1 [3 days at 27 o C] 30 Suspended Solids 50 Oil & Grease 10 (b) Raw Meat from own Slaughter House. BOD 1 [3 days at 27 o C] 30 Suspended Solids 50 Oil & Grease 10 (c) Raw Meat from other sources Disposal via Screen and Septic Tank. C.Sea Food Industry BOD 1 [3 days at 27 o C] 30 Suspended Solids 50 Oil and Grease 10  The emission standards from Boiler House shall conform to the standards already prescribed under E(P) Act, 1986 vide notification No.G.S.R.742(E), dated 30.8.90. 1 Substituted by Rule 2 of the Environment (Protection) Amendment Rules, 1996 notified by G.S.R.176(E), dated 2.4.1996 may be read as BOD (3 days at 27oC) wherever BOD 5 days 20oC occurred. The Environment (Protection) Rules, 1986 443 Sr. No. Industry Parameter Standards 1 2 3 4 Note : (i) TLWK – Tonnes of Live Weight Killed (ii) In case of disposal into municipal sewer where sewage is treated the industries shall install screen and oil & grease separation units. (iii) The industries having slaughter house along with meat processing units will be considered in meat processing category as far as standards are concerned. 51. FOOD AND FRUIT PROCESSING INDUSTRY: EFFLUENTS Concentration not to exceed – mg/l except pH Quantum gm/MT of product Category A. Soft Drinks (a) Fruit based/ Synthetic (more than 0.4 MT/Day) bottles and tetrapack pH 6.5 – 8.5 - Suspended Solids 100 Oil and Grease 10 BOD 1 [3days at 27 o C] 30 (b) Synthetic (less than 0.4 MT/Day) Disposal via septic Tank - B. Fruit & Vegetables (a) Above 0.4 MT/Day pH 6.5 – 8.5 - Suspended Solids 50 Oil and Grease 10 BOD 1 [3days at 27 o C] 30 (b) 0.1-0.4 MT/day (10 MT/year) Disposal via septic Tank - C. Bakery (a) Bread and Bread & Biscuit (i) Continuous process (More than 20T/day) pH 6.5 - 8.5 - BOD 1 [3days at 27 o C] 200 25 1 Substituted by Rule 2 of the Environment (Protection) Amendment Rules, 1996 notified by G.S.R.176(E), dated 2.4.1996 may be read as BOD (3 days at 27oC) wherever BOD 5 days 20oC occurred. The Environment (Protection) Rules, 1986 444 Sr. No. Industry Parameter Standards 1 2 3 4 (ii) Non-continuous process (less than 20 MT/day) - Disposal via Septic tank (b) Biscuit Production (i) 10 T/day & above pH 6.5 – 8.5 BOD 1 [3days at27 o C] 300 35 D. Confectioneries EFFLUENTS (a) 4 T/day and above pH 6.5 – 8.5 - Suspended Solids 50 Oil and Grease 10 BOD 1 [3days at 27 o C] 30 (b) Below 4 T/day Disposal via Septic Tank Note : To ascertain the category of ‗unit fails‘ the average of daily production and waste water discharge for the preceding 30 operating days from the date of sampling shall be considered. * The emission from the boiler house shall conform to the standards already prescribed under E(P) Act, 1986 vide Notification No. GSR 742(E) dated 30.8.90. 52. *JUTE PROCESSING INDUSTRY : EFFLUENTS Concentration in mg/l except pH and Water consumption pH 5.5 – 9.0 BOD 1 [3days at 27 o C] 30 Suspended Solids 100 Oil and Grease 10 Water Consumption 1.60 Cum/Ton of product produced. 1 Substituted by Rule 2 of the Environment (Protection) Amendment Rules, 1996 notified by G.S.R.176(E), dated 2.4.1996 may be read as BOD (3 days at 27oC) wherever BOD 5 days 20oC occurred. The Environment (Protection) Rules, 1986 445 Sr. No. Industry Parameter Standards 1 2 3 4 Note : 1. Water Consumption for the Jute processing industry will be 1.5 Cum/Ton of product from January, 1992. 2. At the present no limit for colour is given for liquid effluent. However, as far as possible colour should be removed. * Stack emissions from boiler house shall conform to the standards already prescribed under Environment (Protection) Act, 1986, vide Notification No. GSR 742(E), dated 30.08.90. 53. LARGE PULP & PAPER NEWS PRINT/ RAYON GRADE PLANTS OF 1 [CAPACITY ABOVE 24000 MT PER ANNUM] EFFLUENTS Concentration in mg/l except pH and TOCL pH 7.0 – 8.5 BOD 2 [3 days at 27 o C] 30 COD 350 Suspended Solids 500 3 [Absorbable Organic Halogens (AOX) in effluent discharge 1.5 kg/ton of product with effect from the date of publication of this notification.1.0 kg/ton of product with effect from the 1 st day of March,2008.] Flow (Total Waste Water Discharge) ** (i)Large Pulp & Paper 200 Cum/Ton of Paper produced (ii)Large Rayon Grade Newsprint 150 Cum/Ton of Paper produced. 54. SMALL PULP AND PAPER EFFLUENT Paper Plant of Capacity upto 24000 MT/Annum : Category : A. *Agrobased Total waste water discharge 200 cum/Ton of paper produced B. **Waste paper based Total waste water discharge 75 cum/Ton of paper produced 1 Substituted by Rule 2(ii) (a) of the Environment (Protection) Third Amendments Rules, 2005 notified vide Notification No.G.S.R.546(E), dated 30.8.2005. 2 Substituted by Rule 2 of the Environment (Protection) Amendment Rules, 1996 notified by G.S.R.176(E), dated 2.4.1996 may be read as BOD (3 days at 27oC) wherever BOD 5 days 20oC occurred 3 Substituted by Rule 2(ii) (b) of the Environment (Protection) Third Amendments Rules, 2005 notified vide Notification No.G.S.R.546(E), dated 30.8.2005 ** The Standards with respect of total wastewater discharge for the large pulp and paper mills be established from 1992, will meet the standards of 100 cum/Ton of paper produced. The Environment (Protection) Rules, 1986 446 Sr. No. Industry Parameter Standards 1 2 3 4 * The agro based mills to be established from January, 1992 will meet the standards of 150 cum/Ton of paper produced. ** The waste-paper mills to be established from January, 1992 will meet the standards of 50 cum/Tom of paper produced. 55. COMMON EFFLUENT TREATMENT PLANTS: EFFLUENTS (Inlet effluent quality for CETP) (Concentration in mg/l) A. Primary Treatment pH 5.5 – 9.0 Temperature o C 45 Oil & Grease 20 Phenolic Compounds (as C6H5OH) 5.0 Ammonical Nitrogen (as N) 50 Cynide (as CN) 2.0 Chromium hexavalent (as Cr+6) 2.0 Chromium (total)(as Cr) 2.0 Copper (as Cu) 3.0 Lead (as Pb) 1.0 Nickel (as Ni) 3.0 Zinc (as Zn) 15 Arsenic (as As) 0.2 Mercury (as Hg) 0.01 Cadmium (as Cd) 1.0 Selenium (as Se) 0.05 Fluoride (as F) 15 Boron (as B) 2.0 Radioactive Materials Alpha emitters, Hc/ml 10-7 Beta emitters, He/ml 10-8 The Environment (Protection) Rules, 1986 447 Sr. No. Industry Parameter Standards 1 2 3 4 Note : 1. These Standards apply to the small scale industries, i.e. total discharge upto 25 KL/Day. 2. For each CETP and its constituent units, the State Board will prescribe standards as per the local needs and conditions; these can be more stringent than those prescribed above. However, in case of clusters of units, the State Board with the concurrence of CPCB in writing, may prescribe suitable limits. B. Treated Effluent Quality of Common Effluent Treatment Plant Concentration in mg/l except pH & Temperature Into inland surface waters On land for Irrigation Into Marine Coastal areas (a) (b) (c) pH 5.5 - 9.0 5.5 – 9.0 5.5 – 9.0 BOD 1 [3days at 27 o C] 30 100 100 Oil & Grease 10 10 20 Temperature Shall not exceed 40 o C in any section of the stream within 15 metres down stream from the effluent outlet - 45 o C at the point of discharge. Suspended Solids 100 200 (a) For process waste water – 100 (b) For cooling water effluents 10 percent above total suspended matter of effluent cooling water Dissolved Solids (inorganic) 2100 2100 - 1 Substituted by Rule 2 of the Environment (Protection) Amendment Rules, 1996 notified by G.S.R.176(E), dated 2.4.1996 may be read as BOD (3 days at 27oC) wherever BOD 5 days 20oC occurred. The Environment (Protection) Rules, 1986 448 Sr. No. Industry Parameter Standards 1 2 3 4 Total residual chlorine 1.0 - 1.0 Ammonical nitrogen(as N) 50 - 50 Kjeldahl nitrogen (asN) 100 - 100 Chemical Oxygen Demand 250 - 250 Arsenic (as As) 0.2 0.2 0.2 Mercury (as Hg) 0.01 - 0.01 Lead (as Pb) 0.1 - 1.0 Cadmium (as Cd) 1.0 - 2.0 Total Chromium (asCr) 2.0 - 2.0 Copper (as Cu) 3.0 - 3.0 Zinc (as Zn) 5.0 - 15 Selenium (as Se) 0.05 - 0.05 Nickel (as Ni) 3.0 - 5.0 Boron (as B) 2.0 2.0 - Percent Sodium - 60 - Cynide (as CN) 0.2 0.2 0.2 Chloride (as Cl) 1000 600 - Fluoride (as F) 2.0 - 15 Sulphate (as SO4) 1000 1000 - Sulphide (as S) 2.8 - 5.0 Pesticides Absent Absent Absent Phenolic compounds (as C6H5OH) 1.0 - 5.0 Note :All efforts should be made to remove colour and unpleasant odour as far as possible. The Environment (Protection) Rules, 1986 449 Sr. No. Industry Parameter Standards 1 2 3 4 1 56. DAIRY EFFLUENTS Concentration in mg/l except pH Quantum per product processed pH 6.5 – 8.5 - *BOD 2 [3 days at 27 o C] 100 - ** Suspended Solids 150 - Oil and Grease 10 - Waste Water generation - 3m 3 /Kl of milk Note :*BOD may be made stringent upto 30 mg/l if the recipient fresh water body is a source for drinking water supply. BOD shall be upto 350 mg/l for the chilling plant effluent for applying on land provided the land is designed and operated as a secondary treatment system with suitable monitoring facilities. The drainage water from the land after secondary treatment has to satisfy a limit of 30 mg/l of BOD and 10 mg/l of nitrate expressed as ‗N‘. The net addition to the groundwater quality should not be more than 3 mg/l of BOD and 3 mg/l of nitrate expressed as ‗N‘. This limit for applying on land is allowed subject to the availability of adequate land for discharge under the control of industry, BOD value is relaxable upto 350 mg/l, provided the wastewater is discharged into a town sewer leading to secondary treatment of the sewage. ** Suspended solids limit is relaxable upto 450 mg/l, provided the wastewater is discharged into town sewer leading to secondary treatment of the sewage. 57. TANNERIES EFFLUENTS Concentration in mg/l except pH Quantum per raw hide processed pH 6.5 – 9.0 - *BOD 2 [3 days at 27 o C] 100 - Suspended Solids 100 - Sulphides (as S) 1 - Tototal Chromium (as Cr) 2 Oil and Grease 10 - Waste Water generation - 28 m 3 /T * For effluent discharge into inland surface waters BOD limit shall be made stricter to 30 mg/l by the concerned State Pollution Control Board. 1 Sl. No. 56 to 61 and entries relating thereto inserted vide GSR 475(E) dated 5.5.92 published in the Gazette No. 202 dated. 5.5.92. 2 Substituted by Rule 2 of the Environment (Protection) Amendment Rules, 1996 notified by G.S.R.176(E), dated 2.4.1996 may be read as BOD (3 days at 27oC) wherever BOD 5 days 20oC occurred. The Environment (Protection) Rules, 1986 450 Sr. No. Industry Parameter Standards 1 2 3 4 ****58. NATURAL RUBBER PROCESSING INDUSTRY Centrifuging and creaming units Crape and crumb units for disposal into inland surface water for disposal on land for irrigation for disposal into inland surface water for disposal on land for irrigation (a) (b) (a) (b) (Concentration in mg/l, except pH & quantum of waste water generation) (Concentration in mg/l except pH & quantum of waste waster generation) pH 6 – 9 6 – 8 6 – 8 6 – 8 Total Kjeldahl nitrogen (as N) 200(100*) *** 50 *** Ammonical Nitrogen as (N)) 100 (50*) ***` 25 *** BOD 1 [3 days at 27 o C] 20 o C 100 30 100 COD 250 *** 250 *** Oil & Grease 10 20 10 20 Sulphide (as S) 2 *** 2 *** TDS 2100 NP** 2100 NP** SS 100 200 100 20 Quantum of waste water generation 5 lit/kg of product processed 8 lit./kg of product processed 40 lit/kg of product processed 40 lit./kg of product processed * To be achieved in three years. ** Not prescribed in case effluent is used for rubber plantation of their own. In other cases suitable limit, as necessary may be prescribed by the State Board. *** Not specified. **** These standards supersede the standards notified as serial no. 26 vide Notification No. S.O. 8(E), dated 3 rd June, 1989. 59. BAGASSE-FIRED BOILERS EMISSIONS (Concentration in mg/l) (a) Step Grate Particulate Matter 250 (b) Horse shoe/pulsating grate Particulate Matter 500 (12% CO2) (c) Spreader Stroker Particulate Matter 800 (12% CO2) Note : In the case of horse shoe and spreader stroker boilers, if more than one boiler is attached to a single stack, the Standard shall be fixed based on added capacity of all the boilers connected with the stack. 1 Substituted by Rule 2 of the Environment (Protection) Amendment Rules, 1996 notified by G.S.R.176(E), dated 2.4.1996 may be read as BOD (3 days at 27oC) wherever BOD 5 days 20oC occurred. The Environment (Protection) Rules, 1986 451 Sr. No. Industry Parameter Standards 1 2 3 4  60. MAN-MADE FIBRE INDUSTRY (SEMI-SYNTHETIC) EFFLUENTS (Concentration in mg/l except for pH) pH 5.5 - 9.0 Suspended Solids 100 BOD 1 [3 days at 27 o C] 30 Zinc (as Zn) 1 61 CERAMIC INDUSTRY EMISSIONS (Concentration in mg/Nm 3 ) A. Kilns (a) Tunnel, Top Hat, Chamber Particulate Matter 150 Fluoride 10 Chloride 100 Sulphur dioxide ** (b) Down-draft Particulate Matter 1200 Fluoride 10 Chloride 100 Sulphur dioxide ** (c) Shuttle Particulate Matter 150 Fluoride 10 Chloride 100 Sulphur dioxide ** (d) Vertical Shaft Kiln Particulate Matter 250 Fluoride 10 Sulphur dioxide ** (e) Tank furnace Particulate Matter 150 Fluoride 10 Sulphur dioxide ** B. Raw material handling, Processing and operations (a) Dry raw materials handling and processing operations Particulate Matter 150 (b) Basic raw material and processing operations Particulate Matter * (c) Other sources of air pollution Generation Particulate Matter * C. Automatic Spray Unit (a)Dryers (i)Fuel fired dryers Particulate matter 150 (ii)For heat recovery dryer Particulate matter * (b)Mechanical finishing operation Particulate matter * (c) Lime/Plasters of Paris manufacture  Standards notified at Sr. No.2 may also be referred. 1 Substituted by Rule 2 of the Environment (Protection) Amendment Rules, 1996 notified by G.S.R.176(E), dated 2.4.1996 may be read as BOD (3 days at 27oC) wherever BOD 5 days 20oC occurred. The Environment (Protection) Rules, 1986 452 Sr. No. Industry Parameter Standards 1 2 3 4 Capacity : Upto 5T/day Stack Height A. Hood should be provided with a stack of 30 meter height from ground level (including Kiln height) Above 5T/day - do - H=14(Q) 0.3 Where Q is emission rate of SO2 in kg/hr and H=Stack in meters More than 5T/day Particulate matter 500 mg/NM 3 and utp 40 T/day Particulate matter 150 mg/NM 3 Note : Oxygen reference level for particulate matter concentration calculations for kilns mentioned at A(c) is 18% and for those at A(b), A(d) and A(c) is 8%. * All possible preventive measures should be taken to control pollution as far as practicable. ** The standard for sulphur dioxide in terms of stack height limits for kilns with various capacities of coal consumption shall be as indicated below : Coal consumed per day Stack height Less than 8.5 MT 9 m More than 8.5 to 21 MT 12 m More than 21 to 42 MT 15 m More than 42 to 64 MT 18 m More than 64 to 104 MT 21 m More than 104 to 105 MT 24 m More than 105 to 126 MT 27 m More than 126 MT 30 m or using formula H=14 (Qg) 0.3 (whichever is more) Note : In this notification H—Physical height of the stack Qg—Emission of sulphurdioxide in Kg/hr. MT—Metric tones m—meters The Environment (Protection) Rules, 1986 453 S. No. Indsutry Parameter Standards 1. 2. 3. 4. 1[62. VISCOSE FILAMENT YARN (Sub-sector of manmade fibre semi- Synthetic Industry) EFFLUENTS (Concentration in mg/l except for pH) pH 5.5-9.0 Suspended solids 100 BOD(3 days at 27oC) 30 Zinc (as Zn) 5 2[63. STARCH INDUSTRY EFFLUENTS: (Maize products) Concentration not to exceed mg/l (except pH and waste water discharge) pH 6.5-8.5 BOD (3 days at 27oC) Suspended Solids 150 Wastewater discharge 8 m3 /tonne of maize Processed Note : The prescribed limits for BOD and suspended solids shall be made more stringent or less stringent depending upon the conditions and local requirements as mentioned below : (i) BOD shall be made stringent upto 30mg/l if the recipient fresh water body is a source for drinking water supply. (ii) BOD shall be allowed upto 350 mg/l for applying on land provided the land is designed and operated as a secondary treatment system with the requisite monitoring facilities. The drainage water 1 Sl. No. 62 and entries relating thereto inserted by Rule 2(b) of the Environment (Protection) Third Amendment Rules, 1993 by G.S.R. No. 801 (E), dated 31.12.1993. 2 Sl.No.63 to 78 and entries relating thereto inserted by Rule 3 (a) of the Environment (Protection) (Amendment ) Rules, 1996 notified by G.S.R.176(E), dated 2.4.1996. * Substituted by Rule 2 of the Environment (Protection) Amendment Rules, 1996 notified by G.S.R.176(E), dated 2.4.1996 may be read as BOD (3 days at 27oC) wherever BOD 5 days 20oC occurred. The Environment (Protection) Rules, 1986 454 from the land after secondary treatment has to satisfy a limit of 30mg/l of BOD and 10mg/l of nitrate expressed as ―N‖. The net addition to ground water quality should not be more than 3 mg/l of BOD and 10mg/l of nitrate expressed as ―N‖. (iii) BOD shall be allowed upto 350 mg/l for discharge into a town sewer, if such sewer leads to a secondary biological treatment system. (iv) Suspended solids shall be allowed upto 450 mg/l for discharge into a town sewer, if such sewer leads to a secondary biological treatment system. (v) In the event of bulking of sludge, the industry shall immediately apprise the respective State Pollution Control Board. 64. BEEHIVE HARD EMISSION : COKE OVEN (i) New unit Particulate matter 150 mg/Nm3 (corrected to 6% CO2) Hydrocarbons 25 ppm (ii) Existing units Particulate matter 350 mg/Nm3 (corrected to 6% CO2) Note : For control of emissions and proper dispensation of pollutants the following guidelines shall be followed: (i) Units set up after the publication of this notification shall be treated as new units. (ii) A minimum stack height of 20 meters shall be provide by each unit. (iii) Emissions from coke ovens shall be channelised through a tunnel and finally omitted through a stack. Damper adjustment techniques shall be used to have optimum heat utilization and also to control the emission of unburnt carbon particles and combustible flue gases. (iv) Wet scrubbing system or waste heat utilization for power generation or byproduct recovery systems should be installed preferably to achieve the prescribed standards. The Environment (Protection) Rules, 1986 455 (v) After four years from the date of this notification, all the existing units shall comply with the standards prescribed for the new units. 65. BRIQUETTE INDUSTRY EMISSIONS : (COAL) (i) Units having capacity Particulate matter 350 mg/Nm3 less than 10 tonnes (corrected to 6% CO2) (ii) Units having capacity Particulate matter 150 mg/Nm3 10 tonnes or more (corrected to 6% CO2) Note: For control of emissions/and proper dispersal of pollutants, the following guidelines shall be followed by the industry :- (i) A minimum stack height of 20 metres shall be provided. (ii) All ovens shall be modified to single chimney multi-oven systems. (iii) Emissions from ovens shall be channelised through inbuilt draft stack. Optimum heat utilization technique shall be used. (iv) In case of units having capacity 10 tonnes and above, wet scrubbing system shall be provided to control air pollution. 66. SOFT COKE INDUSTRY Particulate matter 350 mg/Nm3 (Corrected to 6% CO2) Note: Wet scrubbing systems alongwith byproduct recovery system shall be provided. GUIDELINES FOR EMISSION CONTROL TO IMPROVE WORK ZONE ENVIRONMENT (APPLICABLE FOR INDUSTRIES AT SERIAL NUMBERS 64, 65 AND 66): (a) Water used for quenching and wet scrubbing shall be recalculated and reused through catch- pits. (b) Leakages in the oven shall be sealed by bentonite or by any suitable paste and by proper maintenance to avoid fugitive emission. The Environment (Protection) Rules, 1986 456 GUIDELINES FOR COAL HANDLING AND CRUSHING PLANT (APPLICABLE TO INDUSTRIES AT SERIAL NUMBERS 64,65 AND 66) (a) Unloading of coal trucks shall be carried out with proper care avoiding dropping of the materials from height. It is advisable to moist the material by sprinkling water while unloading. (b) Pulverisation of coal shall be carried out in an enclosed place and water sprinkling arrangement shall be provided at coal heaps, crushing area and on land around the crushing unit. (c) Work area surrounding the plant shall be asphalted or concreted. (d) Green belt shall be developed along the boundary of the industry. (e) Open burning of coal to manufacture soft coke shall be stopped. 67. EDIBLE OIL & VANASPATI INDUSTRY EFFLUENTS : Temperature Not more than 5oC above ambient temperature of the recipient waterbody pH 6.5—8.5 Suspended solids 150 mg/l Oil & grease 20 mg/l BOD(3 days at 27oC) 100 mg/l COD 200 mg/l Wastewater Discharge (i) Solvent extraction 2.0 cum/tonne of product (oil) (ii) Refinery/Vanaspati 2.0 cum/tonne of product (refined oil/Vanaspati) (iii)Integrated unit of 4.0 cum/tonne of refined extraction & refinery/ Vanaspati product Vanaspati (iv)Barometric cooling 15.0 cum/tonne of refined water/De-odoriser oil/vanaspati water The Environment (Protection) Rules, 1986 457 Note : (i) The above standards shall be applicable to waste water from processes and cooling. (ii) BOD shall be made stringent upto 30 mg/l if the recipient fresh water body is source of drinking water supply (iii) The standards for boiler emissions shall be applicable as prescribed under Schedule I of these rules. 68. ORGANIC CHEMICALS MANUFACTURING INDUSTRY EFFLUENTS : (a) Compulsory parameters pH 6.5—8.5 BOD(3 days at 27oC) 100 mg/l Oil & Grease 10mg/l Bioassay test Minimum90% survival after 96 hours with at 100% effluent (b) Additional parameters (mg/l) Nitrate(as N) 10 Arsenic 0.2 Hexavalent Chormium 0.1 Total Chormium 1.0 Lead 0.1 Cyanide as CN 0.2 Zinc 0.5 Mercury 0.01 Copper 2.0 Nickel 2.0 Phenolies as C6H3 OH 5.0 Sulphide 2.0 Note : (i) No limit for COD is prescribed but it shall be monitored. If the COD in a treated effluent is persistently greater than 250 mg/l, such industrial units are required to identify chemicals causing the same. In case these are found to be toxic as defined in Hazardous The Environment (Protection) Rules, 1986 458 Chemicals Rules,1989 in Part I of Schedule-I, the State Boards in such cases may direct the industries to install tertiary treatment system stipulated time limit. This may be done on case to case basis. (ii) These standards are not applicable to small scale detergent (formulating units). (iii) The standards for boiler emissions shall be applicable as per the existing emission regulations. (iv) Industry covered under this group are halo- aliphatics, plasticizers, aromatics (alcohols, phenols, esters, acids and salts, aldehydes and ketone), substituted aromatics, aliphatic (alcohols, esters, acids, aldehydes, ketones, amines and amides) and detergents. 69. FLOUR MILLS EFFLUENTS : pH 6.5—8.5 BOD (3 days at 27oC) 100 mg/l Total Suspended Solids 100mg/l Oil & Grease 10mg/l Waste water discharge 2 cubic metre per tonne of wheat processed Note : (i) BOD shall be stringent upto 30 mg/l if the recipient freshwater body is a source for drinking water supply. (ii) BOD shall be allowed upto 350 mg/l for applying on land, provided the land is designed and operated as a secondary treatment system with the requisite monitoring facilities. The drainage water from the land after secondary treatment has to satisfy a limit of 30 mg/l of BOD and 10 mg/l of nitrate expressed as ―N‖. The net addition to ground water quality should not be more than 3mg/l of BOD and 10 mg/l of nitrate expressed as ―N‖. The Environment (Protection) Rules, 1986 459 (iii) BOD shall be allowed upto 350 mg/l for discharge into a town sewer, if such sewer leads to a secondary biological treatment system. (iv) Suspended solids shall be allowed upto 450 mg/l for discharge into a town sewer, if such sewer leads to a secondary biological treatment system. 70. BOILERS(SMALL) Steam generation capacity Particulate matters emission (ton/hour) (mg/Nm3) less than 2 1200* 2 to less than 10 800* 10 to less than 15 600* 15 and above 150** * to meet the respective standards, cyclone/multicyclone is recommended as control equipment with the boiler. ** to meet the standard, bag filter/ESP is recommended as control equipment with the boiler. Note : (i) 12% of CO2 correction shall be the reference value for particulate matter emission standards for all categories of boilers. (ii) These limits shall supercede the earlier limits notified under Schedule I at serial number 34 of Environment (Protection) Act, 1986 vide notification GSR 742(E), dated 30th August, 1990. (iii) Stack Height for small Boilers. For the small boilers using coal or liquid fuels, the required stack height with the boiler shall be calculated by using the formula. H=14 Q0.3 Where H—Total stack height in metres from the ground level. Q=SO2 emission rate in kg/hr. The Environment (Protection) Rules, 1986 460 In no case the stack height shall be less than 11 metres. Where providing all stacks are not feasible using above formula the limit of 400 mg/Nm3 for SO2 emission shall be met by providing necessary control equipment with a minimum stack height of 11 metres. 71.PESTICIDES INDUSTRY (i) Compulsory Parameters mg/l except pH pH 6.5—8.5 BOD (3 days at 27oC) 100 Oil & Grease 10 Suspended solids 100 Bioassay test Minimum 90% survival of fish after 96 hours with 90% effluent and 10% dilution water. Test shall be carried out as per IS : 6502-1971. (ii) Additional Parameters mg/l (a) Heavy metal Copper 1.0 Manganese 1.0 Zinc 1.0 Mercury 0.01 Tin 0.1 Any other like Nickel shall not exceed 5 times the drinking water standards (BIS) individually. (b) Organics Phenol & Phenolic Compounds as C6H5OH 1.0 (c) Inorganics Arsenic as AS 0.2 Cyanide as CN 0.2 Nitrate as NO3 50 Phospate as P 5.0 The Environment (Protection) Rules, 1986 461 (d) Specific pesticide (microgram/litre) Benzene Hexachloride 10 DDT 10 Dimethoate 450 Copper oxychloride 9600 Ziram 1000 2,4D 400 Paraquat 23000 Propanil 7300 Nitrofen 780 Other/below mentioned Pesticides individually 100 Other pesticides : (i) Insecticides : Aluminium Phosphide Lindane Phrethrum extract Dichloroves Malathlon Quinalphos EDTC Mixer Methyl-Bromide Monocrotophos Ethylene Dibromide Nicotine Sulphate CarbaryI Ethion Oxydemeton MethyI Endosulfan Fenitrothoron MethyI Parathion Fenvalerate Lime-sulphur Phosphamidon Phorate Temephos (ii) Fungicides : Aureofungin Organomercurials (MEMC & PMA) Barium Polysulphide Sulphur (Collodal), Wettable & Dust) Cuprous Oxide Streptocyceline Ferbam Thiram Mancozeb Zenib Manab Carbendazim Nickel Chloride Tridemoraph (iii) Rodenticides : (iv) Nematicides : (v) Weedicides Comafuryl Metham N-Sodium Fluchloralin Warfarin Isoproturon Zinc Phosphide Butachlor Anilphos (vi) Plant Growth Regulants : Chloromequat Chloride Nemphalene Acetic Acid (vii) Any other pesticide not specified above The Environment (Protection) Rules, 1986 462 Note : (1) Limits shall be complied with at the end of the treatment plant before any dilution. (2) From the ‗Additional Parameters‘ specified in 71(ii), only the relevant (based on the raw-materials used and products manufactured) may be prescribed by the concerned State Board on a case to case basis. (3) No limit for COD is prescribed. If the COD in a treated effluent is persistently more than 250 mg/l, such industrial units are required to identify the chemicals causing the same. In case, there are found to be toxic as defined in Schedule I of the Hazardous Chemicals Rules,1989, the State Boards in such cases may direct the industries to install tertiary treatment, stipulating time limit. This may be done on a case to case basis. (4) Solar evaporation followed by incineration is a recognized practice, provide the guidelines of solar evaporation as given below are followed. GUIDELINES ON SOLAR EVAPORATION SYSTEM OR WASTEWATER FROM PESTICIDE INDUSTRY. (i) Solar evaporation pans shall be constructed in such a way that the bottom is atleast one metre above the ground level. (ii) Solar evaporation pans shall be leak proof and of impervious construction and designed as per IS:7290. (iii) The solar evaporation pans shall be designed on the basis of evaporation rate matching to the out put of wastewater. (iv) Wastewater must be pre-treated as below before subjecting to solar evaporation : (a) Oil and grease and floating organics shall be removed so that the rate of evaporation is not affected. (b) Acidic/Alkaline waste must be neutralised before solar evaporation to maintain pH in the range of 6.5 to 8.5. (c) Toxic volatile matter shall be removed so as not to cause air pollution.‘ (v) During the rainy season, storm water shall not be allowed to mix with process waste and enter the pans. The wastewater shall in no case outflow from the evaporation pans. Alternative arrangements shall be made to hold the wastewater in proper impervious tanks and if necessary, force evaporated. The Environment (Protection) Rules, 1986 463 (vi) In no circumstances, the liquid effluent shall be discharged without conforming to the minimal national standards or stored in a holding arrangement which is likely to cause pollution. (vii) The sludge from the solar evaporation pans shall be incinerated or disposed as per the guidelines for management and handling of hazardous waste, published by the Ministry of Environment & Forests, Government of India, after obtaining authorization from the State Pollution Control Board under the hazardous Waste (Handling and Management)Rules,1989. (viii) The facility shall be protected from flood and storm to prevent embankments from erosion or any other damage which may render any portion inoperable. (ix) Facilities shall be protective enclosure to keep wildlife, domestic animals, unauthorized persons, etc. away. 72. OIL DRILLING AND GAS EXTRACTION INDUSTRY A. STANDARDS FOR LIQUID EFFLUENT 1.0 On-Shore facilities(For Marine Disposal) pH 5.5—9.0 Oil & Grease 10 mg/l Suspended solids 100 mg/l BOD(3 days at 27oC) 30 mg/l Note : (i) For on-shore discharge of effluents, in addition to the standards prescribed above, proper marine outfall has to be provided to achieve the individual pollutant concentration level in sea water below their toxicity limits as given below, within a distance of 50 metre from the discharge point, in order to protect the marine aquatic life : Parameter Toxicity limit,mg/l Chromium as Cr 0.1 Copper,as Cu 0.05 Cyanide,as CN 0.005 Fluoride,as F 1.5 Lead, as Pb 0.05 Mercury, as Hg 0.01 Nickel, as Ni 0.1 Zinc, as Zn 0.1 The Environment (Protection) Rules, 1986 464 (ii) Oil and gas drilling and processing facilities, situated on land and away from saline water sink, may opt either for disposal of treated water by on-shore disposal of by re- injection in abandoned well, which is allowed only below a depth of 1000 metres from the ground level. In case of re-injection in abandoned well the effluent have to comply only with respect to suspended solids and oil and grease 100 mg/l and 10 mg/l, respectively. For on- shore disposal, the permissible limits are given below. ________________________________________________________________ S.No. Parameter On-shore discharge standards (Not to exceed) 1. 2. 3. 1. pH 5.5—9.0 2. Temperature 40oC 3. Suspended Solids 100 mg/l 4. Zinc 2 mg/l 5. BOD 30 mg/l 6. COD 100mg/l 7. Chlorides 600 mg/l 8. Sulphates 1000 mg/l 9. TDS 2100 mg/l 10. %Sodium 60 mg/l 11. Oil and Grease 10 mg/l 12. Phenolics 1.2 mg/l 13. Cyanides 0.2 mg/l 14. Fluorides 1.5 mg/l 15. Sulphides 2.0 mg/l 16. Chromium(Cr+6) 0.1 mg/l 17. Chromium (Total) 1.0 mg/l 18. Copper 0.2 mg/l 19. Lead 0.1 mg/l 20. Mercury 0.01 mg/l 21. Nickel 3.0 mg/l 2.0 Off-shore facilities : For off-shore discharge of effluents, the oil content of the treated effluent without dilution shall not exceed 40 mg/l for 95% of the observation and shall never exceed 100 mg/l. Three 8–hourly grab samples are required to be collected daily and the average value of oil and grease content of the three samples shall comply with these standards. The Environment (Protection) Rules, 1986 465 B. GUIDELINES FOR DISCHARGE OF GASEOUS EMISSION : 1.0 DG Sets 1.1 DG Sets at drill site as well as production station shall conform with the norm notified under the Environment (Protection) Act,1986. 2.0 Elevated/ground flares 2.1 Cold Venting of gases shall never be resorted to and all the gaseous emissions are to be flared. 2.2 All flaring shall be done by elevated flares except where there is any effect on crop production in adjoining areas due to the flaring. In such cases, one may adopt ground flaring. 2.3 In case of ground flare, to minimize the effects of flaring, the flare pit at Group Gathering Station(GGS)/Oil Collecting Station(OCS) and Group Collection Station(GCS) shall be made of RCC surrounded by a permanent wall (made of refractory brick) of minimum 5m height, to reduce the radiation and glaring effects in the adjoining areas. 2.4 A green belt of 100 m width may be developed around the flare after the refractory wall in case of ground flaring. 2.5 If the ground flaring with provision of green belt is not feasible, enclosed ground flare system shall be adopted, and be designed with proper enclosure height, to meet the ground level concentration(GLC) requirement. 2.6 In case of elevated flaring, the minimum stack height shall be 30m. Height of the stack shall be such that the max. GLC never exceeds the prescribed ambient air quality limit. 3.0 Burning of effluent in the pits shall not be carried out at any stage. 1[C. GUIDELINES FOR DISPOSAL OF SOLID WASTE, DRILL CUTTING AND DRILLING FLUIDS FOR OFFSHORE AND ONSHORE DRILLING OPERATION- 1. Disposal of Drill Cutting and Drilling Fluids for On-shore Installations: 1 Substituted ―paragraph C‖, for ―paragraph C relating to Guidelines For Disposal of Solid Waste‖ by Rule 2(iii) of the Environment (Protection) Third Amendments Rules, 2005 notified vide Notification No.G.S.R.546(E), dated 30.8.2005. The Environment (Protection) Rules, 1986 466 (a) Drill Cuttings (DC) originating from on-shore or locations close to shore line and separated from Water Base Mud (WBM) should be properly washed and unusable drilling fluids (DF) such as WBM, Oil Base Mud (OBM), Synthetic Base Mud (SBM) should be disposed off in a well designed pit lined with impervious liner located off-site or on-site. The disposal pit should be provided additionally with leachate collection system. Design aspects of the impervious waste disposal pit; capping of disposal pit should be informed by the oil industry to State Pollution Control Board (SPCB) at the time of obtaining consent. (b) Use of diesel base mud is prohibited. Only WBM should be used for on-shore oil drilling operations. (c) In case of any problem due to geological formation for drilling, low toxicity OBM having aromatic content< 1% should be used. If the operators intend to use such OBM to mitigate specific whole problem/ SBM it should be intimated to Ministry of Environment and Forests/State Pollution Control Board. (d) The chemical additives used for the preparation of DF should have low toxicity i.e. 96 hr LC50 > 30,000 mg/l as per mysid toxicity or toxicity test conducted on locally available sensitive sea species. The chemicals used (mainly organic constituents) should be biodegradable. (e) DC separated from OBM after washing should have oil content at < 10 gm/kg for disposal into disposal pit. (f) The waste pit after it is filled up shall be covered with impervious liner, over which, a thick layer of native soil with proper top slope is provided. (g) Low toxicity OBM should be made available at installation during drilling operation. (h) Drilling wastewater including DC wash water should be collected in the disposal pit evaporated or treated and should comply with the notified standards for on-shore disposal. (i) Barite used in preparation of DF shall not contain Hg> 1 mg/kg & Cd> 3mg/kg. The Environment (Protection) Rules, 1986 467 (j) Total material acquired for preparation of drill site must be restored after completion of drilling operation leaving no waste material at site. SPCB should be informed about the restoration work. (k) In case, environmentally acceptable methods for disposal of drill waste such as (a) injection to a formation through casing annuals, if conditions allow (b) land farming at suitable location (c) bio- remediation (d) incineration or (e) solidification can be considered, in such cases oil industry is required to submit proposal to Ministry of Environment and Forests/State Pollution Control Board (MoEF/SPCB) for approval. 2. Disposal of Drill Cutting and Drilling Fluids for Off-shore Installations: (a) Use of diesel base mud is prohibited. Only WBM is permitted for offshore drilling. If the operator intend to use low toxicity OBM or SBM to mitigate specific hole problems in the formation, it should be intimated to MoEF/SPCB. The low toxicity OBM should have aromatic content< 1%. (b) The toxicity of chemical additives used in the DF (WBM or OBM or SBM) should be biodegradable (mainly organic constituents) and should have toxicity of 96 hr LC 50 Value > 30,000 mg /l as per mysid toxicity or toxicity test conducted on locally available sensitive sea species. (c) Hexavalent chromium compound should not be used in DF. Alternative chemical in place of chrome lignosulfonate should be used in DF. In case, chrome compound is used, the DF/ DC should not be disposed offshore. (d) Bulk discharge of DF in offshore is prohibited except in emergency situations. (e) WBM/OBM /SBM should be recycled to a maximum extent. Unusable portion of OBM should not be discharged into sea and shall be brought to on-shore for treatment & disposal in an impervious waste disposal pit. (f) Thoroughly washed DC separated from WBM/SBM & unusable portion of WBM/SBM having toxicity of 96 hr LC50 > 30,000 mg/l shall be discharged off-shore into sea intermittently, at an average rate of 50 bbl/hr/well from a platform so as to have proper dilution & dispersion without any adverse impact on marine environment. The Environment (Protection) Rules, 1986 468 (g) Drill cutting of any composition should not be discharged in sensitive areas notified by the Ministry of Environment and Forests. (h) In case of specific hole problem, use of OBM will be restricted with zero discharge of DC. Zero discharge would include re-injection of the DC into a suitable formation or to bring to shore for proper disposal. In such a case, use of OBM for re-injection should be recorded and made available to the regulatory agency. Such low toxic OBM having aromatic content < 1% should be made available at the installation. (i) In case, DC is associated with high oil content from hydrocarbon bearing formation, then disposal of DC should not have oil content > 10 gm/kg. (j) The DC wash water should be treated to confirm limits notified under EPA, before disposal into Sea. The treated effluent should be monitored regularly. (k) Discharge of DC from the installation located within 5 km away from shore should ensure that there is no adverse impact on marine Eco-system and on the shore. If, adverse impact is observed, then the industries have to bring the DC on-shore for disposal in an impervious waste disposal pit. (l) If any, environmental friendly technology emerges for substitution of DF and disposal technology, it may be brought to the notice of MoEF and regulatory agencies. If the operator desires to adopt such environment friendly technology a prior approval from Ministry of Environment and Forests is required. (m) Barite used in preparation of DF shall not contain Hg> 1 mg/kg & Cd> 3 mg/kg. (n) Oil drilling operators are required to record daily discharge of DC & DF to offshore and also to monitor daily the effluent quality, and submit the compliance report once in every six-month to Ministry of Environment and Forests.] The Environment (Protection) Rules, 1986 469 73. 1[PHARMACEUTICAL (MANUFACTURING AND FORMULATION) INDUSTRY] S. No. Industry Parameter Standards 1 2 3 4 2 [Effluent Standards i. Compulsory Paramters Limiting concentration in mg/l, expect for pH pH 6.0-8.5 Oil & grease 10 BOD (3 days 27 o C) 100* Total suspended Solids 100 Bioassay test 90% survival of fish after first 96 hours in 100% effluent ** ii. Additional Paramters Mercury 0.01 Arsenic 0.20 Chromium (Cr 6+ ) 0.10 Lead 0.10 Cyanide 0.10 Phenolics (C6H5OH) 1.0 Sulphides (as S) 2.0 Phosphate (as P) 5.0 Note: * The BOD and COD limits shall be 30mg/l and 250 mg/l respectively, if treated effluent is discharged directly into a fresh water body i.e., stream, canal, river or lake. ** The Bioassay Test shall be conducted as per IS:6582-1971. (i) Parameters listed as ‗Additional Parameters‘ shall be prescribed depending upon the process and product. (ii) Limits for total dissolved solids in effluent shall be prescribed by the concerned pollution control board/pollution control committee depending upon the recipient water body]. 1 Substituted by Rule 2(b)(i) of the Environment (Protection) Third Amendment Rules, 2009 notified by G.S.R.512(E), dated 9.7.2009 2 Substituted by Rule 2(b)(ii) of the Environment (Protection) Third Amendment Rules, 2009 notified by G.S.R.512(E), dated 9.7.2009 The Environment (Protection) Rules, 1986 470 1 [A. Emission from Incinerator Limiting concentration in mg/Nm3, unless stated Sampling duration in (minutes) unless stated Particulate Matter 50 30 or more (for sampling about 300 litre emission) HCI 50 30 SO2 200 30 CO 100 Daily average Total Organic Carbon 20 30 Total Dioxins and Furans * Existing Incinerator 0.2 ngTEQ/Nm 3 8 hours New Incinerator 0.1 ngTEQ/Nm 3 8 hours Sb+As+Pb+Cr+Co+Cu+ Mn+ Ni+V+Cd+Th+Hg and their compounds 1.5 2 hours * The existing plant shall comply with norms for- dioxins and furans-as 0.1 ng/TEQ/Nrn 3 within 5 years from the date of notification. Notes: i. All monitored values shall be corrected to 11 % oxygen on dry basis. ii. The CO2 concentration In tail gas shall not be less than 7%,. iii. In case, halogenated organic waste is less than 1% by weight in input waste, all the facilities in twin chamber incinerator shall be designed so as to achieve a minimum temperature of 850+25 O C in primary chamber and 950°C in secondary combustion chamber and with a gas residence time in secondary combustion chamber not less than 2 (two) seconds, or all the facilities in single chamber incinerator for gaseous hazardous waste shall be designed so as to achieve a minimum temperature of 950°C in the combustion chamber with a gas residence time not less than 2 (two) seconds. 1 Inserted by Rule 2 of the Environment (Protection) Second Amendment Rules, 2009 notified by G.S.R.149 (E), dated 4.3.2009. The Environment (Protection) Rules, 1986 471 iv. In case halogenated organic waste is more than l% by weight in input waste, waste shall be incinerated only in twin chamber incinerators and all the facilities shall be designed to achieve a minimum temperature of 850+25°C in primary chamber and 1100 o C in secondary combustion chamber with a gas residence time in secondary combustion chamber not less than 2 (two seconds). v. Scrubber meant for scrubbing emissions shall not be used as quencher. vi. Incineration plants shall be operated (combustion chambers) with such temperature, retention time and turbulence, as to achieve Total Organic Carbon (TOC) content in the incineration ash and residue less than 3%, and their loss on ignition is less than 5% of the dry weight. In case of non-conformity, ash and/or residue shall be re-incinerated. vii. The incinerator shall have a chimney of atleast thirty metre height. B. Effluent from Incinerator i. Effluent from scrubber(s) and floor washing shall flow through closed conduit/pipe network. ii. Storm water shall not be allowed to mix with scrubber water and/or floor washings. iii. Storm water shall be channelized through separate drains passing through a HDPE lined pit having holding capacity of 10 minutes (hourly average) of rainfall. iv. The built up in Total Dissolved Solids (TDS) in wastewater of floor washings shall not exceed 1000 mg/l over and above the TDS of raw water used. v. Effluent shall not be stored in holding tank(s) in such manner which may cause pollution to groundwater. The Environment (Protection) Rules, 1986 472 vi. Effluent (scrubber water and floor washings) shall be discharged into receiving water conforming to the norms prescribed under Schedule VI: General Standards for Discharge of Environment Pollutions (Part A: Effluents) notified under the Environment (Protection) Rules, 1986]. 1 [74 BRICK KILNS (i) Emission Standards Bull’s Trench Kiln (BTK) Category* Limiting concentration in mg/Nm 3 Particulate matter small medium large 1000 750 750 minium (metre) Stack height Small 22 or induced draft fan operating with minimum draft of 50 mm WG with 12 metre stack height. Medium 27 or induced draft fan operating with minimum draft of 50 mm WG with 15 metre stack height. Large 30 or induced draft fan operating with minimum draft 50 mm WG with 17 metre stack height. *Category Trench withdh (m) Production (bricks/day) Small BTK <4.50 Less than 15,000 Medium BTK 4.50-6.75 15,000-30,000 Large BTK Above 6.75 Above 30,000 1 Substituted by Rule 2 of the Environment (Protection) Fourth Amendment Rules, 2009 notified by G.S.R.543(E), dated 22.7.2009. The Environment (Protection) Rules, 1986 473 (ii) Down-Draft Kiln (DDK) Category++ Limiting concentration in mg/Nm 3 Particulate matter small/large/medium 1200 Minimum (metre) Stack height small 12 medium 15 large 18 ++Category Production (bricks/day) small DDK Less than 15,000 medium DDK 15,000-30,000 large DDK Above 30,000 (iii) Vertical Shaft Kiln (VSK) Category** Limiting concentraion in mg/l Nm 3 Particulate matter small/large/medium 250 Minimum (metre) Stack height small 11 (at least 5.5m from loading platform) medium 14 (at least 7.5 m from loading platform) large 16 (at least 8.5 m from loading platform) **Category No.of Shafts Production (bricks/day) small VSK 1-3 Less than 15,000 medium VSK 4-6 15,000-30,000 large VSK 7 or more above 30,000 Notes: 1. Gravitational Settling Chamber along with fixed chimney of appropriate height shall be provided for all Bull‘s Trench kilns. 2. One chimney per shaft in Vertical Shaft Kiln shall be provided. The two chimneys emanating from a shaft shall either be joined (at the loading platform in case of brick chimney or at appropriate level in case of metal chimney) to from a single chimney. 3. The above standards shall be applicable for different kilns if coal, firewood and/or agricultural residues are used as fuel]. The Environment (Protection) Rules, 1986 474 75. SODA ASH INDUSTRY (SOLVAY PROCESS) PARAMETER MINAS (Recipient body specified) ________________________________________ Marine Brackish Inland surface pH 6.5—9 6.5—9 6.5—9 Temperature 45 o C or less 45 o C or less 45 o C or less Oil & Grease 2 mg/l 20 mg/l 10 mg/l Suspended Solids(SS) 500 mg/l 200 mg/l 100 mg/l Ammoniacal nitrogen 5 mg/l 50 mg/l 30 mg/l Bio-assay 96 hours 96 hours 96 hours 30% survival 90% survival 90% survival Note :- MINAS for disposal in brackish and inland surface water are without any dilution. Standards for Dual Process Soda Ash Plants : Parameter MINAS ___________________ (Inland Surface Water) pH 6.5—8.0 Ammoniacal nitrogen, as N(mg/l) 50 Nitrate nitrogen, as N(mg/l) 10 Cyanide, as CN(mg/l) 0.2 Hexavalent chromium(mg/l) 0.1 Total chromium(mg/l) 2.0 Suspended solids(mg/l) 100 Oil and Grease (mg/l) 10 Note : The Standards are to be implemented by the industry in a time targeted schedule 1 [by December, 1999]. The progress on the time targeted implementation schedule shall be periodically submitted by the industry to the State Pollution Control Board and Central Pollution Control Board. 1 Substituted by Rule 2 (ii) of the Environment (Protection) (Second Amendment) Rules, 1999 notified by Notification G.S.R.682(E), dated 5.10.1999. The Environment (Protection) Rules, 1986 475 76. EMISSION STANDARD FOR SO2 FROM CUPOLA FURNACE : Standard for Sulphur Dioxide emission from Cupola Furnace : Characteristics Emission limit Sulphur dioxide (SO2) emission 300 mg/Nm 3 at 12% CO2 corrections To achieve the standard, foundries may install scrubber, followed by a stack six times the diameter of the Cupola beyond the charging door. Note : In case due to some technical reasons, installation of scrubber is not possible, then value of SO2 to the ambient air has to be effected through the stack height. 77. SPECIFICATIONS OF MOTOR GASOLINE FOR EMISSION RELATED PARAMETERS : Sl. Characteristics Requirement Method of test No. ref.to P:of IS:1448 (i) Reid Vapour Pressure at 38 o C,Kpa 35 to 70 P : 39 (ii) Benzeno, Percent by volume,Max 5.0 (1) P : 104 (iii) Lead Content(as Pb)g/l,Max 0.15(low leaded)(2) P : 38 0.013 (unleaded) (iv) Sulphur, percent by mass, Max 0.10 (unleaded P : 34 0.20 (leaded) (v) Potential Gum, g/m3, Max 50 ASTM 873 : 8 (vi) Gum (Solvent Washed)g/m3 Max 40 P : 29 (vii) Oxygenates Content Ether (MTBE, 15 ETBE) Alcohol, percent by volume, Max (viii) Phosphorus See Foot Note (3) ASTMD 3231 (1) 3.0 percent by volume maximum in metro cities by 2000 AD. (2) 0.15 g/l by 31 st December, 1996 (for entries country). 0.013 g/l by 1 st April 1995 (in four metrocities); by 1 st December,1998(for all State capitals/UTs and major metro cities) and by 1 st April,2000 for the entire country. (3) Phosphorous containing additives shall be absent. The Environment (Protection) Rules, 1986 476 Note : (a) Above specifications applied to leaded as well as unleaded petrol except lead content. (b) For new refineries coming up during or after 1997 the specification applicable by 2000 for existing refineries shall be applicable by 1997. 78. SPECIFICATION OF DIESEL FUEL FOR EMISSION RELATED PARAMETERS : Sl.No. Characteristics Requirement Method of Test Ref. To P : of IS : 1448 (i) Density at 15 o C, Kg/m3 820 to 880( 1 ) P : 32 (ii) Cetane Number, Min 45 o ( 2 ) P : 9 (iii) Distillation 85 percent by volume 350 P : 18 recovery at o C Max 95 percent by volume recovery at o C,Max 370 (iv) Sulphur, percent by mass 0.50( 3 ) P : 33 (1) 820 to 860 by 2000 AD (2) 48 by 31 st December,1998(except in the refineries- Digboi, Gauhati and Bongaigaon Refineries & Petrochemicals Ltd.) (3) (i) 0.50 percent by mass by 1st April 1996 in four metros and Taj Trapezium; (ii) 0.25 percent by mass by 1st October,1996 in Taj Trapezium; (iii) 0.25 percent by mass by 1st April,1996 throughout the country. Note : (a) Above specifications apply to HSD only. (b) For new refineries coming during or after 1997 specification applicable by 2000 for existing refineries shall be applicable by 1997. (c) ‗P‘ refers to parts of IS : 1448. The Environment (Protection) Rules, 1986 477 Sl. No. Industry Parameter Standard New Batteries (at Green Field Site) Rebuild Batteries Existing Batteries Fugitive Visible Emissions 1 [ 2 79 COKE OVEN PLANTS (by product recovery type) (a) Leakage from door (b) Leakage from charging lids (c) Leakage from AP Covers (d) Charging emission (Second/charge) 5(PLD)* 1(PLL)* 4(PLO)* 16(with HPLA)* 10(PLD)* 1(PLL)* 4(PLO)* 50 (with HPLA)* 10(PLD)* 1 (PLL)* 4(PLO)* 75 Stack Emission of Coke Oven (a) SO2(mg/Nm 3 ) (b) NOx,(mg/ Nm 3 ) (c) SPM,(mg/Nm 3 ) 800 500 50 800 500 50 800 500 50 (d) SPM emission during charging – for stamp charging batteries (stack emission) mg/Nm 3 (e) SPM emission during coke pushing (stack emission) gm/ton of coke 25 5 25 5 (applicable to stationary land based system) 25 - (f) Sulphur in Coke Oven gas used for heating (mg/Nm 3 ) 800 - - Emission for quenching operation (a) Particulate matter gm/tonne of coke produced 50 50 - Benzo-Pyerine (BaP) concentration in work zone air (µg/m 3 ) (a )Battery area (top of the battery) (b) Other units in coke oven plant (c )Ambient standards (mg/Nm 3 ) 5 2 10 5 2 10 5 2 10 1 Substituted by Rule 2(vi) by Rule 2(VI) of the Environment (Protection) First Amendment Rules, 2006 notified vide Notification G.S.R.46(E), dated 3.2.2006. 2 Sl. No. 79 and entries relating thereto inserted by the Environment (Protection) Second Amendment Rules, 1997 vide G.S.R. 631(E), dated 31.10.1997. The Environment (Protection) Rules, 1986 478 For control of emissions and to maintain environmental quality in work zone area, the following guidelines shall be followed, namely:- (i) New coke oven units shall follow any of the low-emission procedures, such as, coke dry cooling, non-recovery coke-ovens. Indirect Quenching Process, Jumbo coke oven reactor, Modified Wet Quenching System with appropriate environmental controls (e.g. baffles, filtering media, collection and treatment of residual water from quench tower and recycling; Use of process water as quenching water shall not be permissible). (ii) Effective pollution control measures (for e.g. Extensive maintenance and cleaning of oven doors and frame seals, ascension pipes, charging holes and lids and other equipment; On-main charging system(HPLA); Luting charging holes with clay-suspension; Modified guide/transfer car with emission control system etc. shall be used to reduce coal charging and coke pushing emissions. (iii) During rebuilding or installing new coke oven batteries, the following clean technology and pollution control measures be adopted: (a) air-cooled self-sealing doors; (b) the hydro-jet cleaning system shall be provided for the door and door frame cleaning with a facility of hydro jet pressure of 600 kg/cm 2 ; (c) the charging should be accomplished with hermetically sealed charging sleeves and screw feeder in charging car. The charging car should also be equipped with magnetic lid lifter and lid and frame cleaning mechanism (applicable to top charging batteries); (d) to provide aspiration through high-pressure ammonia liquor (HPLA) injection in goose neck and emission should be transferred directly to gas collecting mains; (e) water sealed AP covers should be provided; (f) computerized combustion control and moisture control systems. (iv) In addition to the above the new coke oven batteries, which will be installed after the date of publication of this notification at green field site and rebuild batteries wherever technically feasible should also be equipped to treat their pushing emissions with stationary land-based system with collection hood and wet scrubbing units for gas cleaning. The Environment (Protection) Rules, 1986 479 (v) In the case of existing coke ovens with wet quenching, the new procedures as in (i) and (ii) shall be adopted. (vi) The fugitive visible emission standards i.e. PLD*, PLL* and PLO*, charging emission (second/charge). Note: Units set up after the publication of this notification shall be treated as new units. *HPLA - Aspiration through high pressure liquor injection in gooseneck; *PLD - Percent leaking doors; * PLL - Percent leaking lids; and * PLO - Percent leaking off takes]. 1 [80. SPECIFICATIONS OF TWO-STROKE ENGINE OIL : Specification Standard Test Procedure Two-stroke engine oil grade Minimum smoke JASO-M342-92 for JASO-FC as per Index of 85. JASO-FC and ASTM D-4857 for API TC JASO M-345-93 specification And API TC as per specification No.ASTM D 4859 The above specification shall be effective from the 1 st day of April,1999.] 2 [81. BATTERY MANUFACTURING INDUSTRY (i) Lead Acid Battery Manufacturing Industries. Emission Standards. Source Pollutant Concentration based Standards (mg/Nm 3 ) Grid casting Lead Particulate matter 10 25 Oxide manufacturing Lead Particulate matter 10 25 Paste mixing Lead Particulate matter 10 25 Assembling Lead Particulate matter 10 25 PVC Section Particulate matter 150 1 Sl. No. 80 and entries relating thereto inserted by the Environment (Protection) Amendment Rules, 1998 vide G.S.R. 504 (E), dated 20.8.1998. 2 Sl. No. 81 to 87 and entries relating thereto inserted by the Environment (Protection) Amendment Rules, 1998 vide G.S.R. 7 (E), dated 22.12.1998. The Environment (Protection) Rules, 1986 480 - To comply with the respective standards, all the emissions from above- mentioned sources shall be routed through stack connected with hood and fan in addition to above, installation of control equipment viz. Bag filter/ventury scrubber, is also recommended. - The minimum stack height shall be 30 m. Liquid Effluent Discharge Standards ________________________________________________________________________ Pollutant Concentration based standards pH 6.5—8.5 Suspended solids 50 mg/1 Lead 0.1 mg/l (ii) Dry Cell Manufacturing Industry : Emission Standards Pollutant Concentration based Standards (mg/Nm 3 ) Particulate matter 50 Manganese as Mn 5 - To Comply with the respective standards, all the emissions from above- mentioned sources shall be routed through stack connected with hood and fan. In addition to above, installation of control equipment viz. bag filter/ventury scrubber, is also recommended. - The minimum stack height shall be 30m. Effluent Standards Pollutant Concentration based standards pH 6.5---8.5 Total suspended solids 100 mg/l Manganese as Mn 2 mg/l Mercury as Hg 0.02 mg/l Zinc as Zn 5 mg/l (iii) Secondary Lead Smelters Pollutant Concentration based standards Lead as Pb 10 mg/Nm 3 Particulate matter 50 mg/Nm 3 Minimum stack height 30 m The Environment (Protection) Rules, 1986 481 82. ENVIRONMENTAL STANDARDS FOR GAS/NAPTHA-BASED THERMAL POWER PLANTS (i) Limit for emissions of NOx (a) For existing units---150ppm (v/v) at 15% excess oxygen. (b) For new units with effect from 1.6.1999. Total generation of gas turbine Limit for Stack NOx emission [v/v),at 15% excess oxygen] (a) 400 MW and above (i) 50 ppm for the units burning natural gas. (ii) 100 ppm for the units burning naphtha. (b) Less than 400 MW but (i) 75 ppm for the units burning natural gas. Upto 100 MW (ii) 100 ppm for the units burning naphtha (c) Less than 100 MW 100 ppm for units burning natural gas or naphtha as fuel (d) For the plants burning 100 ppm gas in a conventional boiler. (ii) Stack height H in m should be calculated using the formula H=14 Q 0.3 , where Q is the emission rate of SO2 in kg/hr, subject to a minimum of 30 mts. (iii) Liquid waste discharge limit. Parameter Maximum limit of concentration (mg/l except for pH and temperature) pH 6.5-8.5 Temperature As applicable for other thermal power Plants Free available chlorine 0.5 Suspended solids 100.0 Oil and grease 20.0 Copper (total) 1.0 Iron (total) 1.0 Zinc 1.0 Chromium (total) 0.2 Phosphate 5.0 The Environment (Protection) Rules, 1986 482 1 [83. STANDARDS/GUIDELINES FOR CONTROL OF NOISE POLLUTION FROM STATIONARY DIESEL GENERATOR(DG) SETS * * * ………… ] 84. TEMPERATURE LIMIT FOR DISCHARGE OF CONDENSER COOLING WATER FROM THERMAL POWER PLANT A . New thermal power plants commissioned after June 1,1999. New thermal power plants, which will be using water from rivers/lakes./ reservoirs shall install cooling towers-irrespective location and capacity. Thermal power plants which will use sea water for cooling purposes, the condition below will apply. B. New projects in coastal areas using sea water. The thermal power plants using sea water should adopt suitable system to reduce water temperature at the final discharge point so that the resultant rise in the temperature of receiving water does not exceed 7 o C over and above the ambient temperature of the receiving water bodies. C. Existing thermal power plants. Rise in temperature of condenser cooling water from inlet to the outlet of condenser shall not be more than 10 o C. D. Guidelines for discharge point : 1. The discharge point shall preferably be located at the bottom of the water body at mid-stream for proper dispersion of thermal discharge. 2. In case of discharge of cooling water into sea, proper marine outfall shall be designed to achieve the prescribed standards. The point of discharge may be selected in consultation with concerned State Authorities/NOI. 3. No cooling water discharge shall be permitted in estuaries or near ecologically sensitive areas such as mangroves, coral reefs/spawning and breeding grounds of acquatic flora and fauna. 85. ENVIRONMENTAL STANDARDS FOR COAL WASHERIES 1. Fugitive emission standards. - The difference in the value of suspended particulate matter, delta (∆), measured between 25 and 30 metre from the enclosure of coal crushing plant in the downward and leeward wind direction shall not exceed 150 microgram per cubic meter. Method of measurement shall be High Volume Sampling and Average flow rate, not less than 1.1 m 3 per minute, using upwind downwind method of measurement : 1 Serial No..83 and entries relating thereto omitted by Rule 2 (b) of the Environment (Protection) Second Amendment Rules, 2002 notified vide notification G.S.R. 371(E), dated 17.5.2002. The Environment (Protection) Rules, 1986 483 2. Effluent discharge standards - The coal washeries shall maintain the close circuit operation with zero effluent discharge. - If in case due to some genuine problems like periodic cleaning of the system, heavy rainfall etc. it become necessary to discharge the effluent to sewer land stream then the effluent shall conform to the following standards at the final outlet of the coal washery. S.No. Parameter Limits 1. pH 5.5—9.0 2. Total suspended solids 100 mg/l 3. Oil & Grease 10 mg/l 4. B.O.D (3 days 27 o C) 30 mg/l 5. COD 250 mg/l 6. Phenolics 1.0 mg/l 3. Noise level standards - Operational/Working zone—not to exceed 85 dB(A) Leq for 8 hours exposure. - The ambient air quality standards in respect of noise as notified under Environmental (Protection)Rules,1986 shall be followed at the boundary line of the coal washery. 4. Code of practice for Coal Washery. - Water or Water mixed chemical shall be sprayed at all strategic coal transfer points such as conveyors, loading/unloading points etc. As far as practically possible conveyors, transfer points etc. shall be provided with enclosures. - The crushers/pulverisers of the coal washeries shall be provided with enclosures, fitted with suitable air pollution control measures and finally emitted through a stack of minimum height of 30m. conforming particulate matter emission standard of 150 mg/Nm3 or provided with adequate water sprinkling arrangement. - Water sprinkling by using fine atomizer nozzeles arrangement shall be provided on the coal heaps and on around the crushers/pulverisers. - Area, in and around the coal washery shall be pucca either asphalted or concreted. The Environment (Protection) Rules, 1986 484 - Water consumption in the coal washery shall not exceed 1.5 cubic meter per tonne of coal. - The efficiency of the setting ponds of the waste water treatment system of the coal washery shall not be less than 90%. - Green belt shall be developed along the road side, coal handling plants, residential complex, office building and all around the boundary line of the coal washery. - Storage bunkers, hoppers, rubber decks in chutes and centrifugal chutes shall be provided with proper rubber linings. - Vehicles movement in the coal washery area shall be regulated effectively to avoid traffic congestion. High pressure horn shall be prohibited. Smoke emission from heavy duty vehicle operating in the coal washeries should conform the standards prescribed under Motor Vehicle Rules,1989. 86. WATER QUALITY STANDARDS FOR COASTAL WATERS MARINE OUTFALLS In a coastal segment marine water is subjected to several types of uses. Depending of the types of uses and activities, water quality criteria have been specified to determine its suitability for a particular purpose. Among the various types of uses there is one use that demands highest level of water quality/purity and that is termed a ―designated best use‖ in that stretch of the coastal segment. Based on this, primary water quality criteria have been specified for following five designated best uses :- Class Designated best use SW-1(See Table 1.1.) Salt pans, Shell fishing, Mariculture and Ecologically Sensitive Zone SW-II (See Table 1.2) Bathing, Contact Water Sports and Commercial fishing. SW-III (See Table 1.3) Industrial cooling, Recreation(non-contact) and Aesthetics SW-IV (See Table 1.4) Harbour SW-V (See Table 1.5) Navigation and Controlled Waste Disposal The Standards alongwith rationale/remarks for various parameters for different designated best uses, given in Table 1.1 to 1.5 The Environment (Protection) Rules, 1986 485 TABLE 1.1 PRIMARY WATER QUALITY CRITERIA FOR CLASS SW-1 WATERS (For Salt pans, Shell fishing, Mariculture and Ecologically Sensitive Zone) S. No. Parameter Standards Rationale/Remarks 1. 2. 3. 4. 1. pH range 6.5---8.5 General broad range, conductive for propagation of acquaitc lives is given. Value largely dependant upon soil-water interation. 2. Dissolved Oxygen 5.0 mg/l or 60 per cent saturation value whichever is higher Not less than 3.5 mg/l at any time of the year for protection of aquatic lives. 3. Colour and Odour No noticeable colour or offensive odour. Specially caused by chemical compound like creosols, phenols, naptha pyridine benzene, toluene etc. causing visible colouration of salt crystal and fainting fish flesh. 4. Floating Matters Nothing obnoxious or detrimertal for use purpose Surfactants should not exceed an upper limit of 1.0 mg/l and the concentratic not to cause any visible foam. 5. Suspended Solids None from sewage or industrial waste origin Settleable innert matters not in such concentration that would impair any usages specially assigned to this class. 6. Oil and Grease (including Petroleum Products) 0.1 mg/l Concentration should not exceed 0.1 mg/l as because it has effect on fish eggs and larvae. 1 [7. Heavy Metals : Mercury (as Hg) Lead (as Pb) Cadmium (as Cd) 0.001 mg/l 0.001 mg/l 0.01 mg/l] Values depend on : (i) Concentration in salt,fish and shell fish. (ii) Average per capita consumption per day. (iii)Minimum ingestion rate that induces symptoms of resulting diseases. Note : SW-1 is desirable to be safe and relatively free from hazardous chemicals like pesticides, heavy metals and radionuclide concentrations. Their combined (synergistic or antagonistic) effects on health and aquatic lives are not yet clearly known. These chemicals undergo bio-accumulation, magnification and transfer to human and other animals through food chain. In areas where fisheries, salt pans are the governing considerations, and presence of such chemicals apprehended/reported, bioassay test should be performed following appropriate methods for the purpose of setting case specific limits. 1 Substituted by Rule 2(iii) of the Environment (Protection) (Second Amendment) Rules, 1999 published in the Notification G.S.R.682(E), dated 5.10.1999. The Environment (Protection) Rules, 1986 486 TABLE 1.2 PRIMARY WATER QUALITY CRITERIA FOR CLASS SW-II WATERS (For Bathing, Contact Water Sports and Commercial Fishing) S.No. Parameter Standards Rationale/Remarks 1. 2. 3. 4. 1. pH range 6.5---8.5 Range does not cause skin or eye irritation and is also conducive for propagation of aquatic lives. 2. Dissolved Oxygen 4.0 mg/l or 50 per cent saturation value whichever is higher. Not less than 3.5 mg/l at anytime for protection of aquatic lives. 3. Colour and Odour No noticeable colour or offensive odour Specially caused by chemical compound like creosols phenols, naptha, benzene, pyridine toluene etc. causing visible colouration of water and tainting of and odour in fish flesh. 4. Floating Matters Nothing obnoxious or detrimental for use purposes. None in such concentration that would impair usages specially assigned to this class. 5. Turbidity 30 NTU (Nephelo Turbidity Unit) Measured at 0.9 depth 6. Fecal Coliform 100/100 ml(MPN) The average value not exceeding 200/100 ml in 20 per cent of samples in the year and in 3 consecutive samples in monsoon months. 7. Biochemical Oxygen Demand (BOD) (3 days at 27 o C) 3 mg/l Restricted for bathing (aesthetic quality of water). Also prescribed by IS : 2296- 1974. The Environment (Protection) Rules, 1986 487 TABLE 1.3 PRIMARY WATER QUALITY CRITERIA FOR CLASS SW-III WATERS [For Industrial Cooling, Recreation (non-contact) and Aesthetics] S.No. Parameter Standards Rationale/Remarks 1. 2. 3. 4. 1. pH range 6.5---8.5 The range is conducive for propagation of aquatic species and restoring natural system. 2. Dissolved Oxygen 3.0 mg/l or 40 per cent saturation value whichever is higher. To protect aquatic lives. 3. Colour and Odour No noticeable colour or offensive odour None in such concentration that would impair usages specifically assigned to this class. 4. Floating Matters No visible, obnoxious floating debris, oil slick, scum. As in (3) above. 5. Fecal Coliform 500/100 ml(MPN) Not exceeding 1000/100 ml in 20 percent of samples in the year and in 3 consecutive samples in monsoon months. 6. Turbidity 30 NTU Reasonably clear water for Recreation Aesthetic appreciation and Industrial cooling purposes. *7. Dissolved Iron (as Fe) 0.5 mg/l or less It is desirable to have the collective concentration dissolved Fe and Mn less or equal to 0.5 mg/l to avoid scaling effect. *8. Dissolved Manganese (as Mn) 0.5 mg/l or less * Standards included exclusively for Industrial Cooling purpose. Other parameters same. The Environment (Protection) Rules, 1986 488 TABLE 1.4 PRIMARY WATER QUALITY CRITERIA FOR CLASS SW-IV WATERS ( For Harbour Waters) S.No. Parameter Standards Rationale/Remarks 1. 2. 3. 4. 1. pH range 6.0---9.0 To minimize corrosive and scaling effect. 2. Dissolved Oxygen 3.0 mg/l or 40 per cent saturation value whichever is higher. Considering bio-degradation of oil and inhibition to oxygen production thorugh photosynthesis. 3. Colour and Odour No visible colour or offensive odour None from reactive chemicals which may corrode paints/ metallic surfaces. 4. Floating materials, Oil, grease and scum (including Petroleum products) 10 mg/l Floating matter should be free from excessive living organisms which may clog or coat operative parts of marine vessels/equipment. 5. Fecal Coliform 500/100 ml(MPN) Not exceeding 1000/100 ml in 20 per cent of samples in the year and in 3 consecutive samples in monsoon months. 6. Biochemical Oxygen Demand (3 days at 27 o C) 5mg/l To maintain water relatively free from pollution caused by sewage and other decomposable wastes. The Environment (Protection) Rules, 1986 489 TABLE 1.5 PRIMARY WATER QUALITY CRITERIA FOR CLASS SW-V WATERS (For Navigation and Controlled Waste Disposal) S.No. Parameter Standards Rationale/Remarks 1. 2. 3. 4. 1. pH range 6.0---9.0 As specified by New England Interstate Water Pollution Control Commission. 2. Dissolved Oxygen 3.0 mg/l or 40 per cent saturation value whichever is higher. To protect aquatic lives. 3. Colour and Odour None in such concentrations that would impair any usages specifically assigned to this class. As in (i) above. 4. Sludge deposits, Solid refuse floating solids, oil grease and scum. None except for such small amount that may result from discharge of appropriately treated sewage and or industrial waste effluents. As in (i) above. 5. Fecal Coliform 500/100 ml (MPN) Not exceeding 1000/100 ml in 20 per cent of samples in the year and in 3 consecutive samples in monsoon months. The Environment (Protection) Rules, 1986 490 87. EMISSION REGULATIONS FOR RAYON INDUSTRY A. Existing Plants Estimation of Uncontrolled Emission Quantity (EQ) of CS2 : For VSF, EQ = 125 kg of CS2/t of fibre For VFY, EQ = 225 kg of CS2/t of fibre Stack Height (H) requirement, m Remarks 11 Q 0.41-3Vs D/u A minimum of 80% of total emission shall pass through stack. If the calculated stack height is less than 30m, a minimum of height 30 m shall be provided _______________________________________________________________________ Where Q ----CS2 emission rate, kg/hr VS---stack exit velocity, m/sec. D ---diameter of stack, m. U ----annual average wind speed at top of stack, m/sec. Multiple Stacks 1. If there are more than one stack existing in the plant, the required height of all stacks shall be based on the maximum emission rate in any of the stacks. In other words, all the stacks carrying CS2 emission shall be of same heights (based on the maximum emission rate). 2. Number of stacks shall not be increased from the existing number. However, the number of stacks may be reduced. The existing stacks may be rebuilt and if stacks are to be relocated condition 3 below applies. 3. Spacing among the stacks (x) at the minimum shall be 3.0 H (in m). If distance, x, between two stacks is less than 3.0 H (in m), emission shall be considered as single point source and height of both the stacks shall be calculated considering all emission is going through one stack. The Environment (Protection) Rules, 1986 491 B. Ambient Air Quality Monitoring The industry shall install three air quality monitoring stations for CS2 and H2S measurements in consultation with State Pollution Control Board (SPCB) to ensure attainment of WHO recommended ambient air quality norms (CS2 = 100 ug/m 3 and H2S = 150 ug/m 3 , 24 = hr. average). 1 [C. For new plants/expansion projects being commissioned on or after 1.6.1999 For new plants or expansion projects, the emission standards for existing plants covered in (a) above shall apply subject to compliance of the ambient air quality norms for CS2 and H2S indicated in (b) above. The new plants or expansion projects shall provide adequate space for undertaking retrofittings. (Note : a and b above also apply to new plants or expansion projects).] 2 [88. EMISSION STANDARDS FOR NEW GENERATOR SETS (UPTO 19 KILOWATT) RUN ON PETROL AND KEROSENE WITH IMPLEMENTATION SCHEDULE. The emission standards for portable generator sets run on petrol and kerosene shall be follows :- A. From June 1,2000 Class Displacement (CC) CO(g/kw-hr) HC+NOx(g/kw-hr) 2-stroke engine 4-stroke engine 2-stroke engine 4-stroke engine 1. ≤65 603 623 166 65 2. >65 ≤ 99 - 623 - 36 3. >99 ≤225 - 623 - 19.3 4. >225 - 623 - 16.1 1 Substituted by Rule 2(i) of the Environment (Protection) Second Amendment Rules, 2006 notified by G.S.R.640(E), dated 16.10.2006. 2 Sl. No. 88 and 89 and entries relating thereto inserted by the Environment (Protection) (Second Amendment) Rules, 1999 vide G.S.R. 682 (E), dated 5.10.1999. The Environment (Protection) Rules, 1986 492 B. From June 1,2001 Class Displacement (CC) CO(g/kw-hr) HC+NOx(g/kw-hr) 1. ≤65 519 54 2. >65 ≤99 519 30 3. >99 ≤225 519 16.1 4. >225 519 13.4 C. Test method shall be as specified in SAE J 1088. Measurement mode shall be D1 cycle specified under ISO 8178 (Weighting Factor of 0.3 for 100 % load, 0.5 for 75% load and 0.2 for 50% load). D. Following organizations shall test and certify the generator sets :- 1 [(i) Automotive Research Association of India, Pune. (ii) Indian Institute of Petroleum, Dehradun. (iii) Indian Oil Corporation, R&D Centre, Faridabad. (iv)]Vehicle Research Development Establishment, Ahmedbagar. 2 [(v)International Centre for Automotive Technology, Manesar (Haryana)] These organizations shall submit the testing and certification details to the Central Pollution Control Board, annually. The Central Pollution Control Board may send the experts in the field to oversee the testing. 89 . NOISE STANDARDS FOR FIRE-CRACKERS A. (i) The manufacture, sale or of fire-crackers generating noise level exceeding 125 dB(AI) of 145dB(C) at 4 metres distance from the point of bursting shall be prohibited. (ii) For individual fire-cracker constituting the series (joined fire-crackers), the above mentioned limit be reduced by 5 log10 (N) dB, where N= number of crackers joined together. 1 Renumbered as (i), (ii), (iii) and (iv) respectively by Rule 2(a) of the Environment (Protection) Second Amendment Rules, 2008 notified by G.S.R.280(E), dated 11.4.2008. 2 Inserted by Rule 2(a), ibid. The Environment (Protection) Rules, 1986 493 B. The broad requirements for measurement of noise from fire-crackers shall be- (i) The measurements shall be made on hard concrete surface of minimum 5 metre diameter or equivalet. (ii) The measurements shall be made in free field conditions i.e., there shall not be any reflecting surface upto 15 metre distance from the point of bursting. (iii) The measurement shall be made with an approved sound level metre. C. The Department of Explosive shall ensure implementation of these standards. 1 [D. The fire crackers for the purpose of export shall be exempted from the sub- paragraphs A, B and C above subject to the compliance of the following conditions, namely :- (i) the manufacturer shall have an export order; (ii) the fire crackers shall conform to the level prescribed in the country to which it is exported; (iii) they shall have a different packing colour code, and (iv) there shall be a declaration on the box ―not for sale in India‖ or ―only for export in other countries‖.] Note : dB(A1) : A-weighted impulse sound pressure level in decibel. dB(C)pk : C – weighted peak sound pressure level in decibel.] Footnote : The Principal Rules were published in the Gazette of India vide Notification No.S.O.844 (E), dated the19th November, 1986 and subsequently amended vide : (1) S.O.82(E), dt. 16 th February, 1987 (2) S.O393 (E), dt 16 th April, 1987; (3) S.O.443(E),dt 18 th April, 1987 (4) S.O.64(E),dt. 18 th January, 1988 (5) G.S.R.919(E),dt.12 th Sept., 1988 (6) S.O.8(E),dt. 3 rd January 1989 (7) G.SR.913(E),dt. 24 th October 1989 (8) S.O.914(E),dt. 24 th October, 1989 (9) G.S.R.931(E),dt.27 th October, 1989 (10) G.S.R.103(E),dt. 25 th Dec.,1989 (11) S.O.12(E),dt. 8 th January, 1999 (12) G.S.R.54(E),dt.5 th February, 1990 (13) S.O.136(E),dt.9 th February, 1990 (14) G.S.R.742(E),dt.13 th August, 1990 (15) S.O.23(E),dt.16 th January, 1991 (16) S.O.80(E),dt. 8 th February, 1991 (17) S.O.114(E),dt.19 th February,1991 (18) G.S.R.85(E),dt.20 th February, 1991 (19) G.S.R.93(E),dt 21 h February, 1991 (20) S.O.190(E),dt.18 th March, 1991 (21) S.O.416(E),dt. 20 th June, 1991 (22) S.O.479(E), dt. 25 th July, 1991 (23) S.O.23(E),dt 9 th January, 1992 1 Inserted sub paragraph D by Rule 2(ii) of the Environment (Protection) Second Amendment Rules, 2006 notified by G.S.R.640(E), dated 16.10.2006. The Environment (Protection) Rules, 1986 494 1 [90. STANDARDS FOR COAL MINES 1. AIR QUALITY STANDARDS The Suspended Particulate Matter (SPM), Respirable Particulate Matter (RPM), Sulphur dioxide (SO2) and Oxides of Nitrogen (NOx) concentration in downwind direction considering predominant wind direction, at a distance of 500 metres from the following dust generating sources shall not exceed the standards specified in the Tables I, II and III given below: Dust Generating Sources Loading or unloading, Haul road, coal transportation road, Coal handling plant (CHP), Railway sliding, Blasting, Drilling, Overburden dumps, or any other dust generating external sources like coke ovens (hard as well as soft), briquette industry, nearby road etc. Table-I Category Pollutant Time weighted average Concentration in Ambient Air Method of Measurement 1 2 3 4 5 I New Coal Mines (Coal Mines commenced operation after the date of publication of this notification) Suspended Particulate Matter (SPM) Annual Average * 24 hours ** 360 µg/m 3 500 µg/m 3 - High Volume Sampling (Average flow rate not less than 1.1 m 3 /min) Respirable Particulate Matter (size less than 10 µm) (RPM) Annual Average * 24 hours ** 180 µg/m 3 250 µg/m 3 Respirable Particulate Matter sampling and analysis Sulphur Dioxide (SO2) Annual Average * 24 hours ** 80 µg/m 3 120 µg/m 3 - Improved west and Gaeke method - Ultraviolet fluorescene Oxide of Nitrogen as NO2 Annual Average * 24 hours ** 80 µg/m 3 120 µg/m 3 - Jacob & Hochheiser Modified (Na-Arsenic) Method - Gas phase Chemiluminescence 1 Serial No.90 to 93 and entries relating thereto were inserted by Rule 2(1) of the Environment (Protection) Amendment Rules, 2000 notified vide notification G.S.R. 742(E), dated 25.9.2000. The Environment (Protection) Rules, 1986 495 Table-II Category Pollutant Time weighted average Concentration in Ambient Air Method of Measurement 1 2 3 4 5 II Existing coal fields/mines given below: Karanpura, Ramgarh, Giridih, Rajhara, Wardha, Nagpur, Silewara, Pench Kanhan, Patharkhera, Umrer, Korba, Chirimiri, Central India Coalfields, (including Baikunthpur, Bisrampur), Singrauli, Ib Valley, Talcher, Godavary Valley and any other Suspended Particulate Matter (SPM) Annual Average * 24 hours ** 430 µg/m 3 600 µg/m 3 - High Volume Sampling (Average flow rate not less than 1.1 m 3 /minute) Respirable Particulate Matter (size less than 10 µm) (RPM) Annual Average * 24 hours ** 215 µg/m 3 300 µg/m 3 Respirable Particulate Matter sampling and analysis Sulphur Dioxide (SO2) Annual Average * 24 hours ** 80 µg/m 3 120 µg/m 3 1. Improved west and Gaeke method 2. Ultraviolet fluorescene Oxide of Nitrogen as NO2 Annual Average * 24 hours ** 80 µg/m 3 120 µg/m 3 1. Jacob & Hochheiser Modified (Na- Arsenic) Method 2. Gas phase Chemilumine- scence The Environment (Protection) Rules, 1986 496 Table-III Category Pollutant Time weighted average Concentration in Ambient Air Method of Measurement 1 2 3 4 5 III Coal mines located in the coal fields of  Jharia  Raniganj  Bokaro Suspended Particulate Matter (SPM) Annual Average * 24 hours ** 500 µg/m 3 700 µg/m 3 - High Volume Sampling (Average flow rate not less than 1.1 m 3 /minute) Respirable Particulate Matter (size less than 10 µm) (RPM) Annual Average * 24 hours ** 250 µg/m 3 300 µg/m 3 Respirable Particulate Matter sampling and analysis Sulphur Dioxide (SO2) Annual Average * 24 hours ** 80 µg/m 3 120 µg/m 3 1.Improved west and Gaeke method 2.Ultraviolet fluorescene Oxide of Nitrogen as NO2 Annual Average * 24 hours ** 80 µg/m 3 120 µg/m 3 1. Jacob & Hochheiser Modified (Na- Arsenic) Method 2. Gas phase Chemilumine- scence Note: * Annual Arithmetic mean for the measurements taken in a year, following the guidelines for frequency of sampling laid down in clause 2. ** 24 hourly / 8 hourly values shall be met 92% of the time in a year. However, 8% of the time it may exceed but not on two consecutive days. The Environment (Protection) Rules, 1986 497 Unauthorised construction shall not be taken as a reference of nearest residential or commercial place for monitoring. In case any residential or commercial or industrial place falls within 500 metres of any dust generating sources, the National Ambient Air Quality Standards notified under schedule VII shall be applicable. 2. FREQUENCY OF SAMPLING – Air quality monitoring at a frequency of once in a fortnight at the dust generating sources given in clause 1 shall be carried out. – As a result of monthly monitoring, if it is found that the value of the pollutant is less than 50% of the specified standards for three consecutive months, then the sampling frequency may be shifted to two days in a quarter year (3 months). – In case, the value has exceeded the specified standards, the air quality sampling shall be done twice a week. If the results of four consecutive weeks indicate that the concentration of pollutants is within the specified standards, then fortnight monitoring may be reverted to. 3. EFFLUENT STANDARDS The standards for effluent discharge into sewer or stream or land, are given below: pH – 5.5 to 9.0 Chemical Oxygen Demand (COD) – 250 mg/l Total Suspended Solids (TSS) – 100 mg/l 200 mg/l (Land for irrigation) Oil & Grease (O & G) – 10 mg/l (Monitoring frequency of these parameters shall be once in a fortnight) Optional parameters : All other parameters indicated in the general standards for discharge of environment pollutants under Schedule VI, shall be in addition to the effluent standards specified under clause 3. (Monitoring frequency shall be once in a year for the optional parameters) 4. NOISE LEVEL STANDARDS 6.00 AM – 10.00 PM 10.00 PM – 6.00 AM Noise level Leq 75 dB(A) Leq 70 dB(A) (Monitoring frequency for noise level shall be once in a fortnight) Occupational exposure limit of noise specified by Director General of Mines Safety (DGMS) shall be complied with by the local mines. The Environment (Protection) Rules, 1986 498 91. NOISE LIMIT FOR GENERATOR SETS RUN WITH PETROL OR KEROSENE 1. Noise limit Noise limit for new generator sets run with petrol or kerosene shall be as given below: Noise Limit from 1 [September 1, 2002] 2 [September 1, 2003] Sound Power level Lwa 90 dBA 86 dBA 2. Applicability These rules shall apply to all new generator sets using petrol or kerosene as fuel, manufactured in or imported into India: Provided that these rules shall not apply to: a) any genset manufactured or imported for the purpose of exports outside India, or b) the genset is intended for the purpose of sample only and not for sale in India. 3. Requirement of certification Every manufacturer or importer (hereinafter referred to as "supplier) of genset (hereinafter referred to as "product") to which these rules apply must have a valid certificate of type approval for all the product models being manufactured or imported after the specified dates. 4. Verification of conformity of production (COP) Every supplier shall subject its products to the verification for conformity of production, by certification body specified in clause 8, every year. 5. Sale of generator sets not complying with these rules The sale of product model, not having valid type approval certificate, or not complying with the noise limits, as determined by the verification for conformity of production, shall be prohibited, in India. 1 Substituted by Rule 2 of the Environment (Protection) Amendment Rules, 2001 published vide Notification No.G.S.R.628(E), dated 30.8.2001 from ‗September 1. 2001 to September 1, 2002‘. 2 Substituted by Rule 2 of the Environment (Protection) Amendment Rules, 2001 published vide Notification No.G.S.R.628(E), dated 30.8.2001 from ‗September 1. 2002 to September 1, 2003‘. The Environment (Protection) Rules, 1986 499 6. Requirement of conformance labelling 6(1) The supplier of the ‗product‘ must affix a conformance label on the product meeting the following requirements: a) the label shall be durable and legible b) the label shall be affixed on a part necessary for normal operation of the ‗product‘ and not normally requiring replacement during the ‗product‘ life. 6(2) The conformance label must contain the following information: a) name & address of the supplier (if the address is described in the owners manual, it may not be included in the label) b) statement that "this product conforms to the Environment (Protection) Rules, 1986 c) type approval certificate number and time phase (i.e. Sept 2001 or Sept 2002) 7. Nodal agency (1) The Central Pollution Control Board shall be the nodal agency for implementation of these rules. (2) In case of any dispute or difficulty in implementation of these rules the matter shall be referred to the nodal agency. (3) The nodal agency shall constitute a Standing Committee to advise it on all matters; including the disputed matters, related to the implementation of these rules. 8. Certification body The following agencies are authorised for type approval and for verification of conformity of production. (1) Automative Research Association of India, Pune; (2) National Physical Laboratory, New Delhi; (3) Naval Science & Technology Laboratory, Visakhapatnam; (4) Fluid Control Research Institute, Palghat; and (5) National Aerospace Laboratory, Bangalore. 9. Compliance and testing procedure The compliance and testing procedure shall be prepared and published by Central Pollution Control Board, with the help of the certification agencies. The Environment (Protection) Rules, 1986 500 92. STANDARDS FOR EFFLUENTS FROM TEXTILE INDUSTRY Parameter Concentration not to exceed, milligram per litre (mg/l), except pH pH 5.5 – 9.0 Total suspended solids 100 Bio-chemical oxygen demand (BOD) 30 Chemical oxygen demand (COD) 250 Total residual chlorine 1 Oil and grease 10 Total chromium as Cr 2 Sulphide as S 2 Phenolic compounds as C6H5OH 1 Note: 1. Where the treated effluent is discharged into municipal sewer leading to terminal treatment plant, the BOD may be relaxed to 100 mg/l and COD to 400 mg/l 2. The quantity of effluent (litre per kilogram of product) shall not exceed 100, 250 and 80 in composite cotton textile industry, composite woolen textile industry and textile processing industry, respectively. 93. PRIMARY WATER QUALITY CRITERIA FOR BATHING WATER In a water body or its part, water is subjected to several types of uses. Depending on the types of uses and activities, water quality criteria have been specified to determine its suitability for a particular purpose. Among the various types of users there is one use that demands highest level of water quality or purity and that is termed as "Designated Best Use" in that stretch of water body. Based on this, water quality requirements have been specified for different uses in terms of primary water quality criteria. The primary water quality criteria for bathing water are specified along with the rationale in Table 1. The Environment (Protection) Rules, 1986 501 Table 1 PRIMARY WATER QUALITY CRITERIA FOR BATHING WATER (Water used for organised outdoor bathing) CRITERIA RATIONALE 1.Fecal Coliform 500 (desirable) MPN/100 ml: 2500 (Maximum Permissible) 2.Fecal Streptococci 100 (desirable) MPN/100 ml: 500 (Maximum Permissible) To ensure low sewage contamination Fecal coliform and fecal streptococci are considered as they reflect the bacterial pathogenicity. The desirable and permissible limits are suggested to allow for fluctuation in environmental conditions such as seasonal change, changes in flow conditions etc. 2. pH: Between 6.5 – 8.5 The range provides protection to the skin and delicate organs like eyes, nose, ears etc. which are directly exposed during outdoor bathing. 3.Dissolved Oxygen: 5 mg/l or more The minimum dissolved oxygen concentration of 5 mg/l ensures reasonable freedom from oxygen consuming organic pollution immediately upstream which is necessary for preventing production of anaerobic gases (obnoxious gases) from sediment. 4.Biochemical Oxygen 3 mg/l or less Demand 3 day, 27 0 C: The Biochemical Oxygen Demand of 3 mg/l or less of the water ensures reasonable freedom from oxygen demanding pollutants and prevent production of obnoxious gases.] 1 [94. NOISE LIMIT FOR GENERATOR SETS RUN WITH DIESEL 1. Noise limit for diesel generator sets (upto 1000 KVA) manufactured on or after the 2 [1 st January, 2005]. The maximum permissible sound pressure level for new diesel generator (DG) sets with rated capacity up to 1000 KVA, manufactured on or after the 2 [1 st January, 2005] shall be 75 dB(A) at 1 metre from the enclosure surface. 1 Serial No.94 and 95 and entries relating thereto were inserted by Rule 2(c) of the Environment (Protection) Second Amendment Rules, 2002 notified vide Notification G.S.R.371(E), dated 17.5.2002. 2 Substituted by Rule 2(a) (i) of the Environment (Protection) Second Amendment Rules, 2004 notified vide Notification No. G.S.R.448 (E), dated 12.7.2004 (Earlier it was 1 st July 2003 as per the Environment (Protection) Second Amendment, Rules, 2002 notified vide G.S.R. 371 (E), dated 17.5.2002. Subsequently, substituted as 1 st July, 2004 by the Environment (Protection) Amendment Rules, 2003 notified by G.S.R.520 (E), dated 1.7.2003 and later substituted as 1 st January, 2005 by the Environment (Protection) Second Amendment Rules, 2004 notified by G.S.R. 448, dated 12.7.2004). The Environment (Protection) Rules, 1986 502 The diesel generator sets should be provided with integral acoustic enclosure at the manufacturing stage itself. The implementation of noise limit for these diesel generator sets shall be regulated as given in paragraph 3 below. 2. Noise limit for DG sets not covered by paragraph 1. Noise limits for diesel generator sets not covered by paragraph 1, shall be as follows: 2.1 Noise from DG set shall be controlled by providing an acoustic enclosure or by treating the room acoustically, at the users end. 2.2 The acoustic enclosure or acoustic treatment of the room shall be designed for minimum 25 dB (A) insertion loss or for meeting the ambient noise standards, whichever is on the higher side (if the actual ambient noise is on the higher side, it may not be possible to check the performance of the acoustic enclosure/acoustic treatment. Under such circumstances the performance may be checked for noise reduction upto actual ambient noise level, preferably, in the night time). The measurement for Insertion Loss may be done at different points at 0.5 m from the acoustic enclosure/room, and then averaged. 2.3 The DG set shall be provided with proper exhaust muffler with insertion loss of minimum 25 dB(A). 2.4 These limits shall be regulated by the State Pollution Control Boards and the State Pollution Control Committees. 2.5. Guidelines for the manufacturers/users of Diesel Generator sets shall be as under: 1. The manufacturer shall offer to the user a standard acoustic enclosure of 25 dB(A) insertion loss and also a suitable exhaust muffler with insertion loss of 25 dB(A). 2. The user shall make efforts to bring down the noise levels due to the DG set, outside his premises, within the ambient noise requirements by proper siting and control measures. 3. Installation of a DG set must be strictly in compliance with the recommendations of the DG set manufacturer. The Environment (Protection) Rules, 1986 503 4. A proper routine and preventive maintenance procedure for the DG set should be set and followed in consultation with the DG set manufacturer which would help prevent noise levels of the DG set from deteriorating with use. 3. LIMITS OF NOISE FOR DG SETS (UPTO 1000 KVA) MANUFACTURED ON OR AFTER THE 1 [1 ST JANUARY, 2005]. 3.1 Applicability 1. These rules apply to DG sets upto 1000 KVA rated output, manufactured or imported in India, on or after 1 [1 st January, 2005]. 2. These rules shall not apply to: (a) DG sets manufactured or imported for the purpose of exports outside India; and (b) DG sets intended for the purpose of sample and not for sale in India. 3.2 Requirement of Certification 2 [Every manufacturer or assembler or importer (hereinafter referred to as "manufacturer")] of DG set (hereinafter referred to as "product") to which these regulations apply must have valid certificates of Type Approval and also valid certificates of Conformity of Production for each year, for all the product models being 3 [manufactured or assembled or imported] from 1 [1 st January, 2005] with the noise limit specified in paragraph 1. 3.3 Sale, import or use of DG sets not complying with the rules prohibited No person shall sell, import or use of a product model, which is not having a valid Type Approval certificate and Conformity of Production certificate. 1 Substituted by Rule 2(a) (i) of the Environment (Protection) Second Amendment Rules, 2004 notified vide Notification No. G.S.R.448 (E), dated 12.7.2004 (Earlier it was 1 st July 2003 as per the Environment (Protection) Second Amendment, Rules, 2002 notified vide G.S.R. 371 (E), dated 17.5.2002. Subsequently, substituted as 1 st July, 2004 by the Environment (Protection) Amendment Rules, 2003 notified by G.S.R.520 (E), dated 1.7.2003 and later substituted as 1 st January, 2005 by the Environment (Protection) Second Amendment Rules, 2004 notified by G.S.R. 448, dated 12.7.2004). 2 Substituted by Rule 2(a) (i) of the Environment (Protection) Eighth Amendment Rules, 2008 notified by G.S.R.752 (E), dated 24.10.2008. 3 Substituted by Rule 2(a) (ii) of the Environment (Protection) Eighth Amendment Rules, 2008 notified by G.S.R.752 (E), dated 24.10.2008. The Environment (Protection) Rules, 1986 504 3.4 Requirement of Conformance Labelling (i) The 1 [manufacturer] of the 'product' must affix a conformance label on the product meeting the following requirements: (a) The label shall be durable and legible. (b) The label shall be affixed on a part necessary for normal operation of the 'product' and not normally requiring replacement during the 'product' life. (ii) The conformance label must contain the following information: (a) Name and address of the 2 [manufacturer] (if the address is described in the owner's manual, it may not be included in the label.) (b) Statement "This product conforms to the Environment (Protection) Rules,1986". (c) Noise limit viz. 75 dB(A) at 1 m. (d) Type approval certificate number. (e) Date of manufacture of the product. 3.5 Nodal Agency (i) The Central Pollution Control Board shall be the nodal agency for implementation of these regulations. (ii) In case of any dispute or difficulty in implementation of these regulations, the matter shall be referred to the nodal agency. (iii) The nodal agency shall constitute a Committee to advise it on all matters; including the disputed matters, related to the implementation of these regulations. 3.6 Authorised agencies for certification The following agencies are authorized to carry out such tests as they deem necessary for giving certificates for Type Approval and Conformity of Production testings of DG sets and to give such certificates:- 1 Substituted by Rule 2(b) of the Environment (Protection) Eighth Amendment Rules, 2008 notified by G.S.R.752 (E), dated 24.10.2008. 2 Substituted ibid. The Environment (Protection) Rules, 1986 505 (i) Automotive Research Association of India, Pune (ii) National Physical Laboratory, New Delhi (iii) Naval Science & Technology Laboratory, Visakhapatnam (iv) Fluid Control Research Institute, Palghat (v) National Aerospace Laboratory, Bangalore 3.7 Compliance and Testing Procedure The compliance and testing procedure shall be prepared and published by the Central Pollution Control Board, with the help of the certification agencies. 1 [4.0 Exemption from the provisions of paragraph 1 and3, for the products (diesel generator sets upto 30 KVA) purchased by the Ministry of Defence, Govt. of India The products manufactured in or imported into India till 2 [30 th April, 2007] for the purpose of supplying to the Ministry of Defence, shall be exempted from the regulations given in paragraph 1 to 3 above, subject to the following conditions, namely:- (i) The 3 [manufacturer] shall manufacture or import the products only after getting purchase order from the ministry of Defence and shall maintain the record of receipts, production/import, dispatch, etc. for inspection by the Central Pollution Control Board. (ii) The special dispensation for noise norms shall be only for the mobile Defence vehicles which, with the present design/configuration, cannot carry the gensets with acoustic enclosures. (iii) Director, Ministry of Defence shall ensure and maintain the serial number of all gensets for the Army and he shall also direct the manufacturers of these genets to emboss on the engine and the main body of the gensets, the words ‗For the use of Army only’. (iv) The genset serial number shall be specially assigned by Ministry of Defence with the request for proposal and contract purchase order and this information shall be forwarded to the Central Pollution Control Board for inspection as and when required. 1 Inserted by Rule 2 of the Environment (Protection) Second Amendment Rules, 2005 notified vide Notification G.S.R.315(E), dated 16.5.2005. 2 Substituted by Rule 2 of the Environment (Protection) Amendment Rules, 2006 notified by G.S.R.464(E), dated 7.8.2006. 3 Substituted by Rule 2(c) of the Environment (Protection) Eighth Amendment Rules, 2008 notified by G.S.R.752 (E), dated 24.10.2008. The Environment (Protection) Rules, 1986 506 (v) Registers shall be maintained at the manufacturers premises and in the Ministry of Defence to ensure that the number of gensets manufactured under special dispensation are not misused. (vi) The gensets procured under this dispensation shall be operated in the remote areas and not in the cities. (vii) This shall be a one time exemption during which the Army shall remodel its vehicles to contain the new gensets and also obtain the necessary Type Approval of the gensets.] 1 [5.0 Exemption from the provisions of paragraph 1 and 3 for sixteen Diesel Generator sets of 45 KVA purchased by the Ministry of Defence, Government of India The 45 KVA DG sets manufactured in India for the purpose of their use in Mobile Decontamination System for use by the Ministry of Defence shall be exempted from the regulations given in paragraph 1 to 3 above subject to the following conditions, namely:- (i) The special dispensation for the noise norms shall be only for the DG sets to be used in Mobile Decontamination System (MDS) by Army which, with the present design/configuration cannot carry the gensets with acoustic enclosures. (ii) The Director, Ministry of Defence shall ensure and maintain the serial number for sixteen gensets and he shall also direct the manufacturers of these generator sets to emboss on the engine and main body of the gensets, the words ―For the use of Army only in Mobile Decontamination System (MDS)‖. (iii) A register shall be maintained at the manufacturers premises and in the Ministry of Defence to ensure that only sixteen numbers of 45 KVA gensets are manufactured under special dispensation and are not misused elsewhere.] 2 [6.0 Transportation of Diesel Generator Sets (above 250 KVA) (i) Diesel Generator set shall be transported after fulfilling the requirement of certification specified in paragraph 3.2 as a complete unit with acoustic enclosure, or dismantled, with relevant genset number specified on acoustic enclosure and silencer for reassembling of the site of its operation. 1 Inserted by Rule 2 of the Environment (Protection) Amendment Rules, 2007 notified by G.S.R. 566(E), dated 29.8.2007. 2 Inserted by Rule 2(d) of the Environment (Protection) Eighth Amendment Rules, 2008 notified by G.S.R.752 (E), dated 24.10.2008. The Environment (Protection) Rules, 1986 507 (ii) Compliance with the noise norms shall be monitored after reassembling the D.G. set at the location of the installation by the concerned State Pollution Control Board or, as the case may be, the Union Territory Pollution Control Committee.] 95. EMISSION LIMITS FOR NEW DIESEL ENGINES (UP TO 800 KW) FOR GENERATOR SETS (GENSETS) APPLICATIONS 1 [1. Emission Limits The emission limits for new diesel engines upto 800 kW for gensets applications shall be as given in the Table below: 2 [TABLE Capacity of diesel engines Date of imple- mentation Emission Limits (g/kw-hr) for Smoke Limit (light absorption coefficient, m -1 ) (at full load) Test Cycle NOX HC CO PM Torque % Weighting Factor Upto 19 kW 1.7.2005 9.2 1.3 3.5 0.3 0.7 100 0.05 75 0.25 >19 kW upto 176 kW 1.1.2004 9.2 1.3 5.0 0.5 0.7 50 0.30 1.7.2004 9.2 1.3 3.5 0.3 0.7 25 0.30 >176 kW upto 800 kW 1.11.2004 9.2 1.3 3.5 0.3 0.7 10 0.10 Explanation: This extension 3 [for engines upto 19 kW] shall be applicable only to those suppliers: 1 Substituted by Rule 2(b) (i) of the Environment (Protection) Amendment Rules, 2003 notified vide Notification G.S.R. 520 (E), dated 1.7.2003. 2 Substituted by Rule 2(b) of the Environment (Protection) Second Amendment Rule, 2004 notified vide Notification G.S.R.448(E), dated 12.7.2004. 3 For the word ‗this extension‘, the word ‗this extension for engines upto 19 kW added by Corrigendum notified vide Notification G.S.R.520(E), dated 12.8.2004. The Environment (Protection) Rules, 1986 508 (I) Who have obtained Type Approval Certificate for atleast one of their engine models in this range upto 30 th June, 2004. 1 [or] (II) Who have submitted the bank guarantee and also contributed towards the study being carried out by the Union Institute of Science, Bangalore, for development of gentset diesel engines to comply with emission limits.] Note I:- The diesel engine 2 [suppliers] in the category of engines upto 19 kW, who are unable to meet the emission limits fixed for such diesel engines for genstes applications vide the notification of the Government of India, in the Ministry of Environment and Forests number G.S.R. 371 (E) dated 17 th May, 2002 (herein referred to as the said notification), may avail the benefit of extension of time provided under this notification subject to the condition that every such 1 [supplier] shall submit (i) an affidavit to the Central Pollution Control Board or the respective State Pollution Control Board or Committees where they are located to the effect that the specified emission limits shall be compiled with by them as per the extended date of implementation given hereinabove for that category of engines without seeking further extension of time and (ii) a bank guarantee of Rs. 50,000 (Rupees Fifty Thousand) which in case of non compliance shall stand forfeited. Note II:- The diesel engine 1 [supplier] in the category of engines more than 19 kW and upto 800 kW, who are unable to meet the emission limits fixed for such diesel engines for gensets applications vide the said notification may avail the benefit of extension of time provided under this notification subject to the condition that every such 1 [supplier] shall submit (i) an affidavit to the Central Pollution Control Board or the respective State Pollution Control Board or Committees where they are located to the effect that the specified emission limits shall be compiled with by them as per the extended date of implementation given hereinabove for that category of engines without seeking further extension of time and (ii) a bank guarantee of Rs 10,00,000/- (Rupees ten lakhs) per parent engine model which in case of non compliance shall stand forfeited. Note III:- The diesel engine 1 [supplier] in the category of engines of more than 176 kW and upto 800 kW shall, in addition to the conditions specified in Note II above, also give an affidavit to the Central Pollution Control Board or to the respective State Pollution Control Boards or Committees where they are located to the effect that they shall develop either individual or a common test facility and get the same approved by the certification agencies mentioned in paragraph 8 of serial number 95 of Schedule I.] 1 The word ‗or‘ added by Corrigendum notified vide Notification G.S.R.520(E), dated 12.8.2004 . 2 For the word ‗manufacturers‘ or ‗manufacturer‘ , the word ‗supplier‘ substituted by Rule 2 of the Environment (Protection) Amendment Rules, 2004 notified vide Notification G.S.R.92(E), dated 29.1.2004. The Environment (Protection) Rules, 1986 509 1 [Explanation: - For the purposes of this paragraph, ‗supplier‘ means manufacturer of new diesel engines for genset applications in India and importer of such diesel engines for gensets applications and diesel gensets imported into India.] 2. Applicability These rules shall apply to all new diesel engines for genset applications (herein after referred to as 'engine') manufactured in India and all diesel engines for genset applications and diesel gensets (herein after referred to as 'product'), imported into India, after the effective date: Provided that these rules shall not apply to: (i) any engine manufactured or engine or product imported for the purpose of export outside India, or; (ii) any engine or product intended for the purpose of sample only and not for sale in India. 3. Requirement of certification Every manufacturer of engine or every importer of engine or product must have valid certificates of Type. Approval and certificates of Conformity of Production for each year, for all engine models being manufactured or for all engine or product models being imported, after the effective date with the emission limit as specified in paragraph 1. 4. Sale, Import or use of engine or product not complying with these rules No person shall sell, import or use of an engine or a product which is not having a valid Type Approval certificate and Conformity of Production certificate as per paragraph 3. 5. Requirement of conformance labelling (i) All the engines (individually or as part of the product) shall be clearly engraved 'Genset Engine' on the cylinder block. (ii) The engine or the product must be affixed with a conformance label meeting the following requirements:- 1 Inserted by Rule 2 (ii) of the Environment (Protection) Amendment Rules, 2004 notified vide Notification G.S.R.92(E), dated 29.1.2004. The Environment (Protection) Rules, 1986 510 (a) the label shall be durable and legible; (b) the label shall be affixed on a part necessary for normal operation of the engine or the product and not normally requiring replacement during the life of the engine or the product. (iii) The conformance label must contain the following information: (a) name and address of the engine manufacturer or the engine or product importer (if the address is given in the owner's manual, it may not be included in the label); (b) statement that 'this engine or product conforms to the Environment (protection) Rules, 1986‘; (c) type approval certificate number; (d) date of manufacture of engine or in case of import, the date of import of the engine or the product. 6. Compliance with BIS specifications All engines up to 1 [19 kw] (individually or as part of the product) shall carry ISI mark and meet relevant BIS specifications (IS 10001). 7. Nodal agency (i) The Central Pollution Control Board shall be the, nodal agency for implementation of these rules. (ii) In case of any dispute or difficulty in implementation of these rules the matter shall be referred to the nodal agency. (iii) The nodal agency shall constitute a Committee to advise it on all matters, including the disputed matters, related to the implementation of these rules. 8. Authorized agencies for certification The following agencies are authorized to carry out such tests as they deem necessary for giving certificates of Type Approval and Conformity of Production tests for Diesel engines and to give such certificates:- (i) Automotive Research Association of India, Pune. (ii) Vehicle Research and Development Establishment, Ahmednagar. 1 Substituted by Rule 2(c) of the Environment (Protection) Amendment Rules, 2003 notified vide Notification G.S.R.520(E), dated 1.7.2003. The Environment (Protection) Rules, 1986 511 1 [(iii) International Centre for Automotive Technology, Manesar (Haryana)] 9. Compliance and testing procedure The compliance and testing procedure shall be prepared and published by the Central Pollution Control Board with the help of the Certification Agencies. 10. Fuel Specification The specification of commercial fuel applicable for -diesel gensets shall be the same as applicable for commercial HSD(High Speed Diesel) applicable for diesel vehicles in the area, from time to time]. 2 [96. EMISSION STANDARDS FOR DIESEL ENGINES (ENGINE RATING MORE THAN 0.8 MW (800 KW) FOR POWER PLANT, GENERATOR SET APPLICATIONS AND OTHER REQUIREMENTS TABLE Parameter Area Category Total engine rating of the plant (includes existing as well as new generator sets) Generator sets commissioning date Before 1.7.2003 Between 1.7.2003 and 1.7.2005 On or after 1.7.2005 NOX (as NO2) (At 15% O2, dry basis, in ppmv A Up to 75 MW 1100 970 710 B Up to 150 MW A More than 75 MW 1100 710 360 B More than 150 MW NMHC (as C) (at 15% O2), mg/Nm 3 Both A and B 150 100 PM (at 15% O2), mg/Nm 3 Diesel Fuels- HSD & LDO Both A and B 75 75 Furnace Oils- LSHS & FO Both A and B 150 100 CO (at 15% O2), mg/Nm 3 Both A and B 150 150 1 Inserted by Rule 2(b) of the Environment (Protection) Second Amendment Rules, 2008 notified by G.S.R.280(E), dated 11.4.2008. 2 Serial No.96 and entries relating thereto inserted by Rule 2 of the Environment (Protection) Third Amendment Rules, 2002 notified vide Notification G.S.R.489(E), dated 9.7.2002. The Environment (Protection) Rules, 1986 512 Parameter Area Category Total engine rating of the plant (includes existing as well as new generator sets) Generator sets commissioning date Before 1.7.2003 Between 1.7.2003 and 1.7.2005 On or after 1.7.2005 Sulphur content in fuel A <2% B <4% Fuel specification For A only Up to 5 MW Only Diesel Fuels (HSD, LDO) shall be used. Stack height (for generator sets commissioned after 1.7.2003) Stack height shall be maximum of the following, in metre: (i) 14 Q 0.3, Q=Total SO2 emission from the plant in kg/hr. (ii) Minimum 6m.above the building where generator set is installed. (iii) 30m. Note: 1. Acronyms used: MW : Mega (10 6 ) Watt FO : Furnace Oil NOX : Oxides of Nitrogen HSD : High Speed Diesel NO2 : Nitrogen Dioxide LDO : Light Diesel Oil O2 : Oxygen LSHS : Low Sulphur Heavy Stock NMHC : Non-Methane Hydrocarbon kPa : Kilo Pascal C : Carbon mm : Milli (10 -3 ) metre PM : Particulate Matter kg/hr : Kilo (10 3 ) gram per hour CO : Carbon Monoxide mg/Nm 3 : Milli (10 -3 )gram per Normal metre cubic SO2 : Sulphur Dioxide ppmv : Part per million(10 6 ) by volume 2. Area categories A and B are defined as follows: Category A: Areas within the municipal limits of towns/cities having population more than 10 lakhs and also up to 5 km beyond the municipal limits of such towns/cities. Category B: Areas not covered by category A. 3. The standards shall be regulated by the State Pollution Control Boards or Pollution Control Committees, as the case may be. The Environment (Protection) Rules, 1986 513 4. Individual units with engine ratings less than or equal to 800 KW are not covered by this notification. 5. Only following liquid fuels viz. High Speed Diesel, Light Diesel Oil, Low Sulphur Heavy Stock and Furnace Oil or liquid fuels with equivalent specifications shall be used in these power plants and generator sets. 6. For expansion project, stack height of new generator sets shall be as per total Sulphur Dioxide emission (including existing as well as additional load). 7. For multi engine plants, fuels shall be grouped in cluster to get better plume rise and dispersion. Provision for any future expansion should be made in planning stage itself. 8. Particulate matter, Non-Methane Hydrocarbon and Carbon Monoxide results are to be normalized to 25 0 C, 1.01Kilo Pascal (760 mm of mercury) pressure and zero percent moisture (dry basis). 9. Measurement shall be performed at steady load conditions of more than 85% of the rated load. 10. Continuous monitoring of Oxides of Nitrogen shall be done by the plants whose total engine capacity is more than 50 Mega Watt. However, minimum once in six month monitoring for other parameters shall be adopted by the plants. 11. Following methods may be adopted for the measurement of emission parameters:- Sl No. Emission Parameters Measurement Methods 1. Particulates Gravimetric 2. SO2 Barium Perchlorate – Thorin indicator method 3. NOx Chemiluminescence, Non Dispersive Infra Red, Non Dispersive Ultra-Violet (for continuous measurement), Phenol disulphonic method 4. CO Non Dispersive Infra Red 5. O2 Paramagnetic, Electrochemical Sensor 6. NMHC Gas Chromatograph-Flame Ionisation Detector The Environment (Protection) Rules, 1986 514 1 [97.BOILERS USING AGRICULTURE WASTE AS FUEL Step Grate 250 mg / Nm 3 Particulate matter Horse Shoe/ 500 mg / Nm 3 Pulsating (12% of CO2) Particulate matter Spreader stroker 500 mg / Nm 3 Particulate matter (12% of CO2); 98. GUIDELINES FOR POLLUTION CONTROL IN GINNING MILLS Measures for Noise Control (i) Creating separate soundproof enclosures for the fans within the ginning area. (ii) Keeping the fans outside the ginning room in separate enclosures. (iii) Roller gins may be covered by sound proof enclosures and use of pneumatic feeding of raw cotton while suction of ginned cotton is introduced to considerably reduce the dust pollution level. Measures for Dust Control (i) The fugitive emission can be largely controlled by employing mechanical or pneumatic handling of raw material and ginned material through covered ducts and providing overhead hoods connected to exhaust through ducts and filters; use of lifting platforms for bale formers. (ii) The overhead hoods with exhaust arrangement can be provided at: (a) The saw-ginning machine where manual handling to maintain proper feeding in the machine. (b) At the feeding point of the roller ginning machine when manual feeding is carried out. (c) At the collection points of ginned cotton from saw ginning condenser] 1 Entry 97 and 98 added by Rule 2 (iv) of the Environment (Protection) Third Amendment Rules, 2005 notified vide Notification G.S.R. 546(E), dated 30.8.2005. The Environment (Protection) Rules, 1986 515 1 [99. SPONGE IRON PLANT (ROTARY KILN) A. Emission Standards* Particulate matter Fuel Type Limiting value for concentration Coal 100 mg/Nm 3 Gas 50 mg/Nm 3 Carbon Monoxide (Vol/Vol.) Coal/gas 1% Stack Height** (minimum) Coal/gas 30.0m Note:- * Emission shall be normalized at 12% CO2 in stack emission, ** Stack height shall be calculated as H=14.0 Q 0.3 where Q is emission of Sulphur Dioxide (SO2) in kg/hr. i.e. SO2(kg/hr) Height (Meter) Upto 12.68 30 12.69-33.08 40 33.09-69.06 50 69.07-127.80 60 127.81-213.63 70 (De-dusting unit) Particulate matter (mg/m 3 ) Existing unit 100 New Unit 50 Note:- (i) Stack attached to de-dusting unit l have minimum height of 30.0 metre. (ii) If, De-dusting unit is connected to After Burner Chamber (ABC), emission shall be emitted through common stack (minimum height 30.0 metre) having separate arrangements for emission monitoring for de- dusting unit. 1 Inserted by Rule 2 (i) of the Environment (Protection) Fourth Amendment Rules, 2008 notified by G.S.R.414(E), dated 30.5.2008. The Environment (Protection) Rules, 1986 516 (Rotary Kiln/De- dusting unit) B. Fugitive Emission Standards Particulate matter Existing Unit New Unit (µg/m 3 ) 3000 2000 Note:- (i) the existing industry shall comply with a standard of 2000 (µg/m 3 ) after one year from the date of notification. (ii) Fugitive emission shall be monitored at a distance 10.0 metre from the source of fugitive emission as per following: Area Monitoring location Raw material handling area Wagon tippler, Screen area, Transfer points, Stock bin area Crusher area Crushing plant, vibrating screen, transfer points Raw material feed area Feeder area, Mixing area, Transfer Points Cooler discharge area Over size discharge area, Transfer points Product processing area Intermediate stock bin area, Screening plant, Magnetic separation unit, Transfer points, Over size discharge area, Product separation area, Bagging area Other areas As specified by State Pollution Control Board/ Pollution Control Committees. C. Effluent Standards pH 5.5-9.0 Total suspended solids 100mg/l Oil & Grease 10 mg/l Chemical oxygen demand 250mg/l The Environment (Protection) Rules, 1986 517 Note:- (i) All effort shall be made to reuse and re-circulate the water and to maintain ‗Zero discharge‘. (ii) Stormwater drain shall be provided within the premises of the industry so as to avoid mixing with effluent]. 1 [100. COMMON HAZARDOUS WASTE INCINERATOR A. Emission Limiting concentration in mg/Nm 3 unless stated Sampling Duration in (minutes) unless stated Particulate Matter 50 30 HCL 50 30 SO2 200 30 CO 100 30 50 24 hours Total Organic Carbon 20 30 HF 4 30 NOx (NO and NO2, expressed as NO2 400 30 Total dioxins and furans 0.1 ngETQ/Nm 3 8 hours Cd+Th+their compounds 0.05 2 hours Hg and its compounds 0.05 2 hours Sb+As+Pb+Co+ Cr+Cu+Mn+Ni+ V+their compounds 0.50 2 hours 1 Inserted by Rule 2 of the Environment (Protection) Fifth Amendment Rules, 2008 notified by G.S.R.481(E), dated 26.6.2008. The Environment (Protection) Rules, 1986 518 Notes: i. All monitored values shall be corrected to 11 % oxygen on dry basis. ii. The CO2 concentration in tail gas shall not be less than 7%. iii. In case, halogenated organic waste is less than 1% by weight in input waste, all the facilities in twin chamber incinerators shall be designed to achieve a minimum temperature of 950 o C in secondary combustion chamber and with a gas residence time in secondary combustion chamber not less than 2 (two) seconds. iv. In case halogenated organic waste is more than 1% by weight in input waste, waste shall be incinerated only in twin chamber incinerators and all the facilities shall be designed to achieve a minimum temperature of 1100 o C in secondary combustion chamber with a gas residence time in secondary combustion chamber not less than 2 (two seconds). v. Incineration plants shall be operated (combustion chambers) with such temperature, retention time and turbulence, as to achieve Total Organic Carbon (TOC) content in the slag and bottom ashes less than 3%, or their loss on ignition is less than 5% of the dry weight]. The Environment (Protection) Rules, 1986 519 1 [101. INCINERATOR FOR PESTICIDE INDUSTRY A. EMISSION Limiting concentration in mg/Nm 3 unless stated Sampling Duration in (minutes) unless stated Particulate Matter 50 30 HCL 50 30 SO2 200 30 CO 100 Daily average Total Organic Carbon 20 30 Total Dioxins and Furans* Existing Incinerator 0.2 ngTEQ/Nm 3 8 hours New Incinerator 0.1 8 hours Sb+As+Pb+Cr +Co+Cu+Mn+Ni +V+ their compounds 1.5 2 hours * The existing plant shall comply with norms for dioxins and furans as 0.1 ng/TEQ/Nm 3 within a period of five years from the date of publication of this notification. Notes: i. All monitored values shall be corrected to 11% oxygen on dry basis. ii The CO2 concentration in tail gas shall note be less than 7%. iii. In case, halogenated organic waste is less than 1% by weight in input waste, all the facilities in single chamber incinerators shall be designed so as to achieve a minimum temperature of 1100°C, in the incinerator. For fluidized bed technology Incinerator, temperature shall be maintained at 950°C. 1 Inserted by Rule 2 of the Environment (Protection) Seventh Amendment Rules, 2008 notified by G.S.R.600(E), dated 18.8.2008. The Environment (Protection) Rules, 1986 520 iv. In case halogenated organic waste in more than 1% by weight in input waste, waste shall be incinerated only in twin chamber incinerators and all the facilities shall be designed to achieve a minimum temperature of 1100 o C in secondary combustion chamber with a gas residence time in secondary combustion chamber not less than two seconds. v. Scrubber meant for scrubbing emissions shall not be less used as quencher. vi Incineration plants shall be operated (combustion chambers) with such temperature, retention time and turbulence, as to achieve Total Organic Carbon (TOC) content in the slag and bottom ashes less than 3%, and their loss on ignition is less than 5% of the dry weight. vii The incinerators shall have a chimney of atleast thirty metre height. B. Wastewater i Wastewater (scrubber water and floor washings) shall be discharged into receiving water conforming to the norms prescribed under Schedule VI: General Standards for Discharge of Environment Pollutions (Part A : Effluents) notified under the Environment (Protection) Rules, 1986. ii The built up in Total Dissolved Solids (TDS) in wastewater of floor washings shall not exceed 1000 mg/l over and above the TDS of raw water used. 1 [102. REFRACTORY INDUSTRY A. Emission Standards (i) Down Draft Kiln (Fuel:Coal) Category * limiting concentration (mg/Nm 3 ) Particulate matter Small/ medium/large 350 Minimum (metres) 1 Inserted by Rule 2 of the Environment (Protection) Amendment Rules, 2009 notified by G.S.R.97(E), dated 18.2.2009. The Environment (Protection) Rules, 1986 521 Stack height Small Medium Large 15 18 21 (ii) Other than Down Draft Kiln (Fuel:Coal) Category * Limiting concentration (mg/Nm 3 ) Particulate matter Small Medium Large 300 200 150 Stack height Small Medium Large Minimum (metres) 15 18 21 (iii) Box, Tunnel Down Draft Kiln, etc. (Fuel:Natural Gas/Producer Gas/LPG or a combination of Fuels/Furnance Oil as Secondary Fuel) Category* Limiting concentration (mg/Nm 3 ) Particulate matter Small Medium/ Large 200 150 Stack height Small Medium Large Minimum (metres) 12 15 18 Category* small kiln Medium kiln Large kiln Production (tpa) <15,000 15,001-50,000 above 50,000 The Environment (Protection) Rules, 1986 522 (iv) Rotary Kiln (Fuel: Furnance Oil) Category** Limiting concentration (mg/Nm 3 ) Particulate matter Small Medium/ Large 200 150 Stack height Small Medium Large Minimum (metres) 35 45 60 Category** Small/rotary kiln medium rotary kiln large rotary kiln Production (tpd) <50 51-100 Above 100 Note:- (i) All values of particulate matter are to be corrected at 6 per cent Carbon Dioxide. (ii) Fugitive emission shall not exceed 10 mg/m 3 from any process or plant. (iii) Each stack shall be at least 2 metre above the top most point of the building, shed or plant in the industry excluding bucket elevator, mill house and vibrating screen. (iv) If more than one kiln is connected to single stack, sum of the production capacity of all the kilns would be considered for determining the capacity of the kiln and accordingly depending upon the total capacity, emission standard and stack height would be implemented. (v) Monitoring of stack shall be carried out at the time of charging and after the completion of charging and average of these two results shall be considered as emission level. The Environment (Protection) Rules, 1986 523 B. EFFLUENT STANDARDS Limiting value for concentration (mg/l except for pH) Inland Surface Water Public Sewer Land for Irrigation pH 5.5 to 9.0 5.5 to 9.0 5.5 to 9.0 Oil and Grease 10 20 10 BOD BOD 3 days, 27 o C 30 250 100 COD 250 - - Suspended Solids 100 600 200 Phenols 1.0 5.0 - Cyanide as CN 0.2 2.0 0.2 Cr(Hexavalent) 0.1 2.0 1.0 Cr(Total) 2.0 2.0 2.0] 1 [103 CASHEW SEED PROCESSING INDUSTRY A. EMISSION STANDARDS Process Limiting concentration in mg/Nm 3 Roasting 250 Particulate Matter Cooking (roasted shell/deoiled cake as fuel) 150 Borma Oven Heater (roasted shell/deoiled cake as fuel) 150 1 Inserted by Rule 2 of the Environment (Protection) Amendment Rules, 2010 notified vide GSR 1(E), dated 1.1.2010. The Environment (Protection) Rules, 1986 524 Minimum (metres) Stack height Roasting 20 Cooking 15 Borma Oven Heater 15 Note:  All values of particulate matter shall be corrected at 4% Carbon Dioxide.  Each stack shall be at least 2 metres above the top most point of the building, shed or plant in the industry.  The emissions from ‗Dog-house‘ shall be channelized alongwith Roasting-drum emissions and shall pass through wet scrubber.  Bio-gasifier shall be installed if roasted shells are used as fuel in the unit. B-EFFLUENT STANDARDS Limiting concentration in mg/l, except for pH Inland surface Water Public sewer Land for Irrigation pH 6.5 to 8.5 6.5 to 8.5 6.5 to 8.5 Oil & Grease 10 20 10 BOD3days, 27oC 30 250 100 Suspended Solids 100 600 200 Phenols 1.0 5.0 -] The Environment (Protection) Rules, 1986 525 1 [104 PLASTER OF PARIS INDUSTRY A. Stack Emission Standards Stack Production Capacity upto 30 tonnes per day (tpd) Source Limiting concentration in mg/Nm 3 Particulate Matter Crusher 500 Calciner 500 Furnace/Grinder 150 Production capacity above 30 tpd Particulate matter Crusher/ Calciner/ Furnace Grinder 150 Notes: 1. The units having production capacity up to 30 tpd shall channelize their emission through a stack or chimney of height at least ten metres above ground level or three metres above the top of shed or building of the industry, whichever is more. 2. The units having production capacity above 30 tpd shall channelize their emission through a stack or chimney of height at least thirty metres above the ground level or three metres above the top of shed or building whichever is more. B. FUGITIVE EMISSION STANDARDS (µG/M 3 ) Particulate Matter 2,000 Note: Fugitive emission shall be monitored at a distance of 10 + 1 metres from the source, irrespective of production capacity.] 1 Inserted by Rule 2 of the Environment (Protection) Second Amendment Rules, 2010 notified vide G.S.R..61(E), dated 5.2.2010. The Environment (Protection) Rules, 1986 526 (F. No. Q-15017/95/2000-CPW) (R. K. VAISH) JOINT SECRETARY TO THE GOVT. OF INDIA Note : The principal rules were published in the Gazette of India vide number S.O. 844(E), dated the 19 th November, 1986 and subsequently amended vide S.O. 433(E), dated the 18 th April, 1987, S.O.64(E) dated the 18 th January, 1988, S.O. 3(E) dated 3 rd January, 1989, S.O. 190(E), dated the 15 th March, 1989, G.S.R. 913(E), dated the24th October, 1989, S.O. 12(E), dated the 8 th January, 1990, G.S.R.742(E), dated the 30 th August, 1990, S.O. 23(E), dated the16th January, 1991, G.S.R. No.93(E), dated the t21st February, 1991, G.S.R. 95(E), dated the 12 th February, 1992, G.S.R. 329(E), dated the 13 th March, 1992, G.S.R. 475(E), dated the 5 th May, 1992, G.S.R. 797 (E), dated the 1 st October, 1992, G.S.R. 386(E), dated the 28 th April, 1993, G.S.R. 422(E), dated the 19 th May, 1993, G.S.R. 801(E), dated the31st December, 1993, G.S.R. 176(E), dated the 3 rd April, 1996, G.S.R. 631(E), dated the 31 st October, 1997, G.S.R. 504(E), dated the 20 th August, 1998, G.S.R.7 (E), dated the 2 nd January, 1999, G.S.R. 682(E), dated the 5 th October, 1999, G.S.R.742(E), dated the 25 th September, 2000, G.S.R. 72(E), dated the 6 th February, 2001, G.S.R. 54(E), dated the 22 nd January, 2002, G.S.R. 371(E), dated the 17 th May, 2002, G.S.R. 489(E), dated the 9 th July, 2002, S.O.1088(E), dated the 11 th October, 2002, G.S.R. 849(E), dated the 30 th December, 2002, G.S.R. 520(E), dated the 1 st July, 2003, G.S.R. 92(E), dated the 29 th January, 2004, G.S.R.448(E), dated the 12 th July, 2005, Corrigenda G.S.R. 520(E), dated the 12 th August, 2004, G.S.R.272(E), dated the 5 th May, 2005, G.S.R.315(E), dated the 16 th May, 2005 and G.S.R.546(E), dated 30 th August, 2005, G.S.R.46(E), dated the 3 rd February, 2006, G.S.R.464(E), dated the 7 th August, 2006, G.S.R.640(E), dated the 16 th October, 2006, G.S.R.566(E), dated the 29 th August, 2007, G.S.R.704(E), dated the 12 th November, 2007, G.S.R.186(E), dated the 18 th March, 2008, G.S.R.280(E), dated the 11 th April, 2008, G.S.R.344(E), dated the 7 th May 2008, G.S.R.414(E), dated the 30 th May, 2008, G.S.R.481(E), dated the 26 th June, 2008, G.S.R.579(E), dated the 6 th August, 2008, G.S.R.600(E), dated the 18 th August, 2008, G.S.R.752(E), dated the 24 th October, 2008, G.S.R.97(E), dated the 18 th February, 2009, G.S.R.149(E), dated the 4 th March, 2009, G.S.R.512(E), dated the 9 th July, 2009, G.S.R.543(E), dated the 22 nd July, 2009, G.S.R.595(E), dated 21 st August, 2009, G.S.R.794(E), dated the 4 th November, 2009, G.S.R.826(E), dated the 16 th November, 2009 G.S.R.1(E), dated 1 st January, 2010 and G.S.R.61(E), dated the 5 th February, 2010. The Environment (Protection) Rules, 1986 527 APPENDIX A FORM I (See rule 7) NOTICE OF INTENTION TO HAVE SAMPLE ANALYSED To …………………………………………………………………………………… …………………………………………………………………………………… Take this notice that it is intended to have analysed the same of ………………… Which has been taken today, the ……………. day of …………………….19………… from …………………………………………………………………………(Name and designation of the person who takes the sample) _______________________________________ *Specify the place where the sample is taken. (SEAL) DATE FORM II (See rule 8) MEMORANDUM TO GOVERNMENT ANALYST From …………………………………………. …………………………………………. To The Government Analyst …………………………………………. …………………………………………. The portion of sample described below is sent herewith for analysis under rule 6 of the Environment (Protection) Rules, 1986. The portion of the sample has been marked by me with the following mark : Details of the portion of sample taken Name and designation of person who sends sample Date………………. (SEAL) The Environment (Protection) Rules, 1986 528 FORM III (See Rule 8) REPORT BY GOVERNMENT ANALYST Report No. ………………….. Date . ………………………… I hereby certify that I …………………………………………………………….. Government Analyst duly appointed under section 13 of the Environment (Protection) Act, 1986 received on the ………………… day of ……………….. 19………………….. from ...……………………………………………………………………………………… 1 ……….…………………………………………………………………………………… a sample of …………………………………………….. for analysis. The sample was in a condition fit for analysis as reported below : I further certify that I have analysed the aforementioned sample on …………… …………………… and declare the result of the analysis to be as follows : 2…………………………………………………………………………………… ……………………………………………………………………………………………… The Condition of seals, fastening of sample on receipt was as follows : ……………………………………………………………………………………………… ……………………………………………………………………………………………… Signed this ……………………………………….day of …...…………………………….. 19…………………………….. Signature Address……………………… (Government Analyst) ……………………………………… ……………………………………… ……………………………………… 1 Here write the name of the officer/authority from whom sample was obtained. 2 Here write full details of analysis and refer to method of analysis. The Environment (Protection) Rules, 1986 529 FORM IV (See rule 11) FORM OF NOTICE By registered post acknowledgement due From (1) Shri …………………………… ………………………………… ………………………………… To ………………………………… ………………………………… ………………………………… Notice under section 19(b) of Environment (Protection) Act, 1986 Whereas an offence under the Environment (Protection) Act, 1986 has been committed/ is being committed by ………………………………………………………… (2) I/we hereby give notice of 60 days under section 19(b) of the Environment (Protection) Act, 1986 of my/our intention to file a complaint in the court against …………………………………………………………(2) for violation of section of the Environment (Protection) Act, 1986. In support of my/our notice, I am /we are enclosed the following documents(3) as evidence of proof of the Environment (Protection) Act, 1986. Signature(s) Place……………………. Dated …………………… Explanation : (1) In case the notice is given in the name of a Company, documentary evidence authorising the persons to sign the notice on behalf of the company shall be enclosed to this notice. Company for this purpose means a company defined in explanation to sub- rule(6) of rule 4. (2) Here give the name and address of the alleged offender. In case of a manufacturing/processing/operation unit, indicate the name/location/nature of activity etc. (3) Documentary evidence shall include photograph/ technical reports/ health report of the area, etc. for enabling enquiry into the alleged violation/ offence. [No. 1(18)/86-PL] T.N. SESHAN, Secy. The Environment (Protection) Rules, 1986 530 1 [FORM-V] (See rule 14) Environmental statement for the financial year ending the 31 st March ……….. PART-A (i) Name and address of the owner/occupier of the industry operation or process (ii) Industry category Primary – (STC Code) Secondary – (SIC Code) (iii) Production capacity – Units ---------- (iv) Year of Establishment (v) Date of last environmental statement submitted PART-B Water and Raw Material Consumption (i) Water consumption m3/d Process Cooling Domestic Name of Products Process water consumption per unit of product output. During the previous financial year During the current financial year (1) (2) (1) (2) (3) 1 Substituted by Rule 2(b) of Environment (Protection) Amendment Rules, 1993 notified vide G.S.R. 386 (E) dated 22.04.1993. The Environment (Protection) Rules, 1986 531 (ii) Raw material consumption *Name of raw materials Name of Products Consumption of raw material per unit of output During the previous financial year During the current financial year * Industry may use codes if disclosing details of raw material would violate contractual obligations, otherwise all industries have to name the raw materials used. PART-C Pollution discharged to environment/unit of output (Parameter as specified in the consent issued) (1) Pollutants Quality of Pollutants discharged (mass/day) Concentrations of pollutants discharges (Mass/volume) Percentage of variation from prescribed standards with reasons. (a) Water (b) Air PART-D HAZARDOUS WASTES (As specified under 1 [Hazardous Wastes (Management, Handling and Transboundry Movement) Rules, 2008)] Hazardous Wastes Total Quantity (Kg.) During the previous financial year During the current financial year (a) From process (b) From pollution control facilities 1 The Hazardous Wastes (Management, Handling and Transboundary Movement) Rules, 2008 notified vide S.O.2265(E), dated 24.9.2008. The Environment (Protection) Rules, 1986 532 PART-E Solid Wastes Total Quantity During the previous financial year During the current financial year (a) From process (b) From pollution control facilities (c) (1) Quantity recycled or re-utilized within the unit. (2) Sold (3) Disposed PART-F Please specify the characterizations (in terms of composition of quantum) of hazardous as well as solid wastes and indicate disposal practice adopted for both these categories of wastes. PART-G Impact of the pollution abatement measures taken on conservation of natural resources and on the cost of production. PART-H Additional measures/investment proposal for environmental protection including abatement of pollution, prevention of pollution. PART-I Any other particulars for improving the quality of the environment. [F.No. Q-15015/1/90-CPA] MUKUL SANWAL, Jt. Secy. The Environment (Protection) Rules, 1986 533 1 [SCHEDULE II] (See rule 3) General standards for discharge of effluents Sl. No. Parameter Standards Inland surface water Public sewers Land for irrigation Marine coastal areas (a) (b) (c) (d) 1. Colour and odour See Note 1 - See Note 1 See Note 1 2. Suspended solids, mg/l, Max 100 600 200 (a) For process waste water-100 (b) For cooling water effluent-10 per cent above total suspended matter of influent cooling water. 3. Particle size of suspended solids Shall pass 850 micron IS Sieve (a) Floatable solids,Max 3 mm (b) Settleable solids Max 850 microns. 4. Dissolved Solids (inorganic), mg/a, max. 2100 2100 2100 5. PH value 5.5 to 9.0 5.5 to 9.0 5.5 to 9.0 5.5 to 9.0 6. Temperature 0 oC, Max Shall not exceed 40 in any section of the stream within 15 meters down stream from the effluent outlet 45 at the point of discharge - 45 at the point of discharge. 7. Oil and grease, mg/l max. 10 20 10 20 8. Total residual chlorine, mg/l, Max. 1.0 - - 1.0 9. Ammonical nitrogen (as N), mg/l, Max. 50 50 - 50 10. Total kjeldahl nitrogen (as N), mg/l, Max. 100 - - 100 11. Free Ammonia (as NH3), Mg/l, Max. 5.0 - - 5.0 12. Biochemical Oxygen Demand 2[3 days at 27C] Max. 30 350 100 100 1 Schedule II inserted vide G.S.R. 919(E) dt. 12.9.88, published in the Gazette no. 488 dt. 12.9.88 and omitted by G.S.R.801(E), dated 31.12.1993. 2 Substituted by Rule2 of the Environment (Protection) Amendment Rules, 1996 notified by G.S.R.176, dated 2.4.1996 may be read as BOD (3 days at 27oC) wherever BOD 5 days 20oC occurred. The Environment (Protection) Rules, 1986 534 13. Chemical Oxygen Demand, mg/l Max. 250 - - 250 14. Arsenic (as As), mg/l, Max. 0.2 0.2 0.2 0.2 15. Mercury (As Hg), Mg/l Max. 0.01 0.01 - 0.01 16. Lead (as Pb), Mg/l, Max. 0.1 1.0 - 1.0 17. Cadmium (as Cd) Mg/l,Max. 2.0 1.0 - 2.0 18. Hexavalent chromium (as Cr+6) mg/l, Max. 0.1 2.0 - 1.0 19. Total chromium (as Cr), mg/l, Max. 2.0 2.0 - 2.0 20. Copper (As Cu) mg/l, Max. 3.0 3.0 - 3.0 21. Zinc. (as Zn), mg/l, Max. 5.0 15 - 15 22. Selenium (as Se), mg/l, Max. 0.05 0.05 - 0.05 23. Nickel (as Ni), mg/l, Max 3.0 3.0 - 5.0 24. Boron (as B), mg/l, Max 2.0 2.0 2.0 -

Previous and next

All provisions of THE ENVIRONMENT (PROTECTION) RULES, 1986

Questions people ask

Is rule 18 of THE ENVIRONMENT (PROTECTION) RULES, 1986 still in force?

Rule 18 of THE ENVIRONMENT (PROTECTION) RULES, 1986 is omitted.