51. Permissible current and pressure in enclosure. -(1) No electric current at
a higher pressure than 280 volts shall be supplied within the enclosure, and all wiring
inside be in heavy gauge screwed conduit .
(2) The cables for the cinematograph machine shall be taken as a separate
circuit from the source of supply and there shall be an efficient l inked iron -clad
switch and fuse inser ted at the point where the supply is taken and in addit ion an
efficient iron-clad double pole switch shall be fi t ted in the cinematograph lamp circuit
inside the enclosure.