Rule 28, The Maharashtra Factories Rules, 1963: Specifications of hygrometer
The Maharashtra Factories Rules, 1963 - Rule 28
Text of rule 28
Specifications of hygrometer
28. Specifications of hygrometer.-(1) Each hygrometer shall comprise two
mercurial thermometers of wet bulb and dry bulb of similar construction and equal
in dimensions, scale and divisionals of scale. They shall be mounted on a frame
with a suitable reservoir containing water.
(2) The wet bulb shall be closely covered with a single layer of muslin kept wet
by means of a wick attached to it and dropping into the water in the reservoir. The
muslin covering and the wick shall be suitable for the purpose clean and free from
size or grease.
104 The Maharashtra Factories Rules, 1963
(3) No part of the wet bulb shall be within 75 mms. from the dry bulb or less
than 25 mms. from the surface of the water in the reservoir and the water reservoir
shall be below it, on the side of it away from the dry bulb.
(4) The bulb shall be spherical and of suitable dimensions and shall be freely
exposed on all sides to the aid of the room.
(5) The bores of the stems shall be such that the position of the top of the
mercury column shall be really distinguishable at a distance of 60 cms.
(6) Each thermometer shall be graduated so that accurate readings may be
taken between 50 and 120 degrees.
(7) Every degree from 50 degrees up to 120 degrees shall be clearly marked
by horizontal lines on the stem, each fifth and tenth degree shall be marked by
longer marks than the intermediate degrees and the temperature marked opposite
each tenth degree, i.e. 50, 60, 70, 80, 90, 100, 110 and 120.
(8) The markings as above shall be accurate, that is to say, at no temperature
between 50 and 120 degrees shall the indicated readings be in error by more than
two tenths of a degree.
(9) A distinctive number shall be indelibly marked upon the thermometer.
(10) The accuracy of each thermometer shall be certified by the National
Physical Laboratory, London, or some Competent Authority appointed by the
Chief Inspector and such certificate shall be attached to the Humidity Register.