Rule 46, The Rajasthan Cinemas (Regulation) Rules, 1959: Enclosure for Apparatus
The Rajasthan Cinemas (Regulation) Rules, 1959 - Rule 46
Text of rule 46
Enclosure for Apparatus
46. Enclosure for Apparatus. - (1) The cinematograph machines shall be placed
in a permanent enclosure of sufficient dimensions to allow the operator to work
freely. The enclosure shall be substantially constructed of fire-resisting
materials or lined with the same.
(2) The entrance to the enclosure shall be fitted with a closely fitting
door of fire-resisting material suitably placed and opening outwards and
all openings, bushes and joints shall be so constructed and maintained
as to prevent so far as possible the escape of any smoke into the
auditorium. If means of ventilation are provided they shall not be
allowed to communicate direct with the auditorium. The area of the
ventilating ducts of the enclosure shall not be less than one percent, of
its floor area.
Explanation.- By 'bush' is meant packing inserted in the holes through
which the pipes and cables pass in order to render such holes
reasonably smoke-proof.
(3) Openings not exceeding six in number shall be permitted in the
front, face of the enclosure, the central one of which must not exceed 8
inches square and those on each side 6 inches square. The projector
opening must be fitted with a screen of fire-resisting material capable of
being actuated both from the inside and from the outside of the
enclosure.
(4) The necessary pipes and cables shall enter through efficiently
bushed openings.
(5) No. unnecessary combustible material shall be allowed within the
enclosure, and as far as possible all necessary combustible material,
films and the like, when not in use shall be kept in fireproof receptacles
suitable for the purpose.