LawGrids logoLAWGRIDS.ORG

Appendix VI, THE INDIAN ELECTRICITY RULES, 1956: APPENDIX VI

THE INDIAN ELECTRICITY RULES, 1956 - Appendix VI

Text of appendix VI

APPENDIX VI

APPENDIX VI SYLLABUS FOR OPERATION AND MAINTENANCE STAFF IN EXTRA-HIGH VOLTAGE SUB-STATION Item No. Particulars Number of Hours 1 2 3 I. Layout and location of 220/132/66/33 K.V sub-station 4 II. Main equipments used together with their specifications 3 III. Construction of high voltage lines, types of towers, types of insulators and their electrical and mechanical characteristics 3 IV Hightension feeders, their load carrying capacities 1 V (i) Alternating and direct currents, relation between voltage, current, power, reactive power & common units in use. Power factor, Ohm’s Law, resistance, reactance, impedance, percentage impedance. Three phase vectors phase, displacement between current and voltage (ii) Basic principle of transformation, magnetisation, hysteresis, reluctance, retentivity, electromagnets Flux density, ampereturns, equation for transformation etc. (iii) Two winding, three winding and auto transformers, grounding transformers, salient features of shell type and core type transformers, hot rolled and cold rolled steel cores, Stampings and their assembly Different vector groups and terminal connections. (iv) Transformer fixtures e.g. Buchholz relay, on-load and off-load tap changer, breathers, conservators, bushings of different types, thermometers, indicators, alarms (v) Cooling of transformer and oil, different methods of cooling, importance of oil filtering and drying-out of tranfromers, dielectric strength of oil, different varieties of filters and their comparison, types of radiators (vi) Transformer tests-failures and causes, maintenance and repairs (vii) Parallel operation, regulation, voltage control, tap, changing, commissioning test 3 4 4 4 4 3 5 VI. Breakers: (i) Functions of breakers, their action (ii) Different types of outdoor and indoor breakers e.g. bulk oil, minimum oil and air blast, principles and their applications. (iii) Operating mechanism, manual, spring, hydraulic, pneumatic, motor 8 (iv) Current rating rupturing capacity, clearance time. (v) Breaker maintenance, failures and their causes, commissioning procedure 8 VII. Busbars: (i) Indoor busbars, their capacity, forces on them during short circuit, busbar mountings and their clearances (ii) Strung and tabular type busbars, their current ratings, supports, jumpers, clearances (iii) Busbars fittings and connectors (iv) High Voltage and Extra-high voltage cables, types, their maintenance and testing 6 VIII. Current and potential transformers: (i) Types of current and potential tranformers, their working principles, ratings, accuracies (ii) Functions of current and potential transformers (iii) Failures of current and potential transformers, their causes 3 IX. Isolators: (i) Tilting and rotating isolators, with and without arcing horns, earthing blades, current ratings, breaking of circuits by isolator, interlocking with circuit breaker (ii) Maintenance of isolators 3 X. Lightning arrestors: (i) Simple description of lightning phenomena and surges (ii) Construction of lightning arrestors and the principles of their working (iii) Different type of lightning arrestors and ratings (iv) Earthing and location of lightning arrestors XI. Control Room: (i) Necessity and function of a control board, types of boards, instruments on the board (ii) Functions of the various relays and indicators, Mimic diagram indicators, annunciator and alarm characteristics of relays, testing and setting of relays (iii) Remote control of breakers, isolators, tap changers, indicators on the control board (iv) Control and power cables 10 XII. Auxiliary supply: (i) Current and ampere-hour ratings of batteries, battery charging equipment, checking of specific gravity of electrolyte, maintenance of batteries (ii) Importance of direct current supply and its functions (iii) Auxiliary direct current supply 3 XIII. Clearance and Compliance of I.E. Rules, 1956: (i) Minimum clearance for different voltages between phases and phase to ground (ii) Indian Electricity Rules pertaining to sub-stations 3 XIV Earthing: (i) Safety earthing and system earthing, the method of earthing e.g. solid earthing, resistance earthing, peterson coil earthing, earthing of lightning arrestor, importance and advantages of each type (ii) Different types of earth electrodes, earthing mats, recommended values of earth resistance, measurement of earth resistances 3 XV Maintenance: Maintenance of log sheet and other records The importance of maintenance of good records 3 XVI. Safety: (i) Safety procedures and procedures for giving line clear and taking it back, Maintenance of records of line clear (ii) First-aid, artificial respiration and shock treatment 10 XVII. Interlocking and sequential operation of different equipments 1 XVIII. Synchronising, charging and discharging of high voltage lines. Live line testing 3 XIX. Calibration and testing of various types of equipments indicating and measuring equipments, recorders, analysers 4 XX. Handling emergency conditions 3 XXI. Diagnosing troubles in the plant from instruments and annunciation 3 XXII. Study of carrier system 2 XXIII. Auxiliary equipments such as compressors, Station lighting etc. 1 XXIV Fire fighting equipment-their operation, maintenance and refilling 1 XXV Personnel managements, duties and responsibilities, labour welfare and labour laws 4 Total Hours 115

Previous and next

All provisions of THE INDIAN ELECTRICITY RULES, 1956

Questions people ask

Is appendix VI of THE INDIAN ELECTRICITY RULES, 1956 still in force?

No repeal of the INDIAN ELECTRICITY RULES, 1956 is recorded.