Rule 99, Punjab Capital(Development and Regulation)Building Rules,1952: Testing ofpipes
Punjab Capital(Development and Regulation)Building Rules,1952 - Rule 99
Text of rule 99
Testing ofpipes
99. Testing ofpipes. - A ventilating pipe to a drain a soil, pipe and waste
pipe shall be capable of withstanding after erection a smoke or air test under
pres.uro.
SECflON2
Water Closets
100. General - (i) As a minimum requirement every residential, commer
cial warehouse and industrial lind public building shallbeprovided wlth at least
onewater closet unless speciallyexempted by the Ch iefAdministrator. Additional
fixtures shall be provided according to the requirements hereinafter prescribed,
Whenever more than one water closet IS required in a puhlic building in
tended to be used by both sexes, separate water closet rooms with separate en
trance doors shall be provided for each sex and be clearly and properly ind icated.
Whenever water closet rooms are provided for the exclusive use of males
urinals may be substituted for one-half'of'thc required number of water closets,
'[(ii) Number of Water closets in residential building. - Every single family
residential building shall be provided with not less than one watcr closet.]
' [( iii) Couuuercial and Warehouse and Industrial Bui ldings . - Every com
mercial and warehouse and industrial building shall be provided with water closets
in accordance with the requirements of 111\: table given below;
No.ofpersens
worldng .
I . .
Minimum number of
water closets
2\ .
Minimum number of
urinals or sinks
3'.
1 to 9
.I0.to-24
25 to 49
'50 to 100
'Over 100
.... l' I.
2 '2
J . 3
5 . . . 5
One water closet for each l'dditional 30 persons.
. . (iv) Publtc buildings. - (a}Iri every school or college building, there shall
be provided not less than one water 0103et for every tweuly persons to be ac-
commodatcd. -. . " .
I [(h}.in every other public building, there shall be provided not less than one
water closet for every one hundred persu.. to be accommodated,
Note. - For the areas not covered under these bye-laws the provisions in
the National Building Code oflndia shall be adhered 10.1_.__•• - 0 . 0 _0 _
1.Sc1: I'b. CIIJl !1l11 (Dev. &; Reg.)BuUdlng(Amendment) Rules. 1993 (22-t.1993)
.!- ...t . " ".~ .
68 Punjab Capital (Development and Regulat ion) Building Rules, 1952
SECTION 4
General
I [107. deleted.]
'lJD8. Tank for industrial chernlcal or other trade affluent. - A. tank
intended for reception or disposal of industrial chemical or other trade affluent
shall be 50 constructed and place as not to cause pollution to any well, spring Or
stream of water ; used or likely to be used for drinking or domestic purposes, or
for the manufacturer or preparation of articles of food or drink for human con
sumption or for the cleaning of vessels with a view to the preparation or sale of
such articles. Any affluent on anYlremises such as Industrial plots or a ny other
processing area shall be permitte only on the permission and approval of the
appror.riateAnte Pollution Board.]
J109. M"lntentit/ce in stale ofrepair. - Any building or any installation in
a buil ing shall be maintained in such a manner that it does not ca use any avoid
able waste or docs 110t cause any nuisance to the public in any manner whatso
ever.]
'1110 . :Deleted.]
I Cill. Deleted.]
I [112. Connection with sewer and use ofSanitary installation. • No connec
tion of any drain to any sewer or storm water drain shall be made or shall any
water borne sanitary or draina~e installation or any part thereof be taken into use
until and unless the ChiefAdministrator under rule 18 grants permission to occupy
the building.] ,
![Provided that the Chief Admin istrator may allow temporary sewer con
nection at the time ofsanction ofthe building plan for the Government building and
the public building only, for the fac ility of'Iubourcrs who would be engaged at work
at the time.]
, 113. Inspection; - Every person by or for whom an¥ water-borne sanitary
installation or drainage installation or any work in connection therewith is carried
out for any existing or new building or in any other premises shall at all reasonable
time afford the Chief Adm inistrator .or a ny officer duly authorised by him fre e
access to such water-borne sanitary installation ordrainage ins tallat ion or work in
connection therewith for the purpose of inspections. .
The officer shall sec that these rules arc complied with bul no such super
vision shall relieve the owner of the building from the duty of seeing that due
care is taken in the supervision or execution ofthe work and providing good and
sufficient material and workmanship.
I (114. 'Deleted .] ", " ,