88. Respollsibility for quality.Qlld workmanslslp. - The person who ap
plies for permission to erect or re-crect a building under Rule 7 shall be respon
s ib le for ensuring that all the building materials used on the build irig a re sound, of
good quality and properly put together, and that the building is struc turally stable.
-- --.-._..-.._----.- _-_..-.._--._._._------------------.-----_._..-...---_.__ --..._--.-----
I. Sec f'b . Capital (Dev, & Reg.) Ouildl ng (Amendment) Rules, 1993 (22- 1- r993)
64 Punjab Capital (Development and Regulation) Building Rules, 1952
(v) Concrete to be filled in. - Concrete shall be filled in so that it shall
extend to the full length of the concrete bed prescribed in clause (iv)
and shall be launched up to not less than half the external diameter of
the pipe. -
(vi) June/ions. • Every branch drain shall joint any other drain obliquely in
the direction ofthe .flow of that drain and as near as practicable to the
invert thereof.
(vii) Drains within or under building. - A sewage drain shall not be
constructed so lIS to be within or under any building, except in a case
where any other situation is impracticable.
Where any such rain or partthereofis constructed within or under a building,
such drain or such part thereof shall :-
(a) be laid or fixed in a direct line, where be practicable and provided
. with adequate means of access;
J [(b) be constructed of cast iron pipes, completely embedded in and
covered with I :3 : 6 cement concrete 15 ems. thick all round.]
(vii i) Protection /0 drains beneath walls,» Where any drain is laid under
a wall, it shall be protected at the part under the w~1I by means of a
relieving arch. flag stone, iron or any other support which shall not
bear on the drain, and shill! be ofsufficient size and strength to prevent
any disturbances or other injury to such drain. .
(ix) [III/:(s to drains within buildings. - A drain shall not be constructed
in such a manner that there shall be within a building any inlet to such
drain except such-inter as may be necessary lrom any sanitary fitting
or any sanitary installation connected directly to such drain.
I [(;r) Inlets /0 drains (0 be trapped - Every inlet other than a ventilating
pipe to such drain shall be properly tapped by a suitable andeffieient
trap and such trap shall be fonned and fixed so as to .be capable of
maintaining a minimum water seal of5 ems.]
'[(;(i) Gully Traps. - Every trapped gully shall be covered with a grating,
the bars of which shall be not more than 10. Every such gully if of
stoneware shall be placed on a bed ofconcreto lit least 10 ems, thick.
Such gully trap shall be so set that the water depth therein is atleast30
crns.] , ,
(xii) Trapping ofdrainsfram sewer, -A suitable and efficient intercepting
trap, with n water seal ofat least 4 inches, at a point as distant as may
be practlcablc fromthe building and as near as may be practicable to
the point at which tho drain may be connected with the sewer, shall be
provided to such a drain before connecting it with' the sewer. Such a
trap.shall be provided with rokingoreleaning arm, filled with a secure
' and, suitable stopper as a means of access to the drain between such
trap and sewer, and shall be located within a manhole.
Ig;dii) Drains 10 be water light. - Such a drain shall be constructed so as
to be water tight and to be capable of resisting a pressure of atleast
1.5 m. head ofwater.]
(xiv) Means ofaccess to drains. - Such a drains shall be provided with
adequate means of access and every means of access shall be :.
(a) constructed so liS to be water-tight;
(b) flUe:! with a suirable cover at the level ofadjoining ground surface;
I. Sec I~~. Cupit..1(Dev, &. Rcg.) OuilJillg (AmclIJoncnl) Rules . 1993 (22,1-1993) ..
~
66 Punjab Capital (Development lind Regulation) Building Rules, 1952
(i) discharge so as not to cause dampness in 8 building;
(II) Ifltdlscharges into a drain , be disconnected from the drain by a trapped
~ul\ywith a suitable grating above the level of the water ill the trap;
(iii) if it is more than six feet In length. be provided with a suitable trap;
(iv) if it disch~r~cs into II soil pipe from II water closet or a waste pipe
from a slop sick, be provided (whatever its length) Witha suitable trap
with minimum water seal of2", adelJu~tely secured against destruction
of the water s031 by syphonage action,
(v) be constructed in the same manner and oflhe sam" material and same
weight as ifsuch pipe were a soil pipe.
Previous and next