LawGrids logoLAWGRIDS.ORG

Rule 29, Punjab Factory Rules 1952: Hand baling machine

Punjab Factory Rules 1952 - Rule 29

Text of rule 29

Hand baling machine

29. Hand baling machine. -An angle iron handle-stop guard shall be installed at right angle to the frame of the machine, the stop guard of which shall be so designed and so located that it will prevent the handle from traveling beyond the vertical position should be handle slips from the operator’s hand when the pawl has been released from the teeth of the take-up gear. 30 Flat-Work ironer.- Each flat-work or coller ironer shall be equipped with a safety bar or other guard across the entire from of the feed or first pressure rolls, so arranged that the striking of the bar or guard by the hand of the operator or other person will stop the machine. The guard shall be such that the operator or other person cannot reach into the rolls without removing the guard. This may be either a vertical guard on all sides or a complete cover. If a vertical guard is used, the distance from the floor or working platform to the top of guard shall not be less than 1.83 meters.” SCHEDULE II (Cotton Ginning) Line shaft: - The line shaft or second motion in cotton ginning factories, when below floor level shall be completely enclosed by a continuous wall or unclimbale fencing with only so many openings as are necessary for access to the shaft for removing cotton seed, cleaning and oiling and such openings shall be provided with gates or doors which, shall be kept closed and locked. SCHEDULE III (Woodworking Machinery) 1. Definitions: -For the purposes of this Schedule:- a) Woodworking machine means a circular saw, band saw, planning machine, chain mortising machine or vertical spindle moulding machine, operating on wood or cork. b) Circular saw means a circular saw working in a bench (including rack bench) but does not include a pendulum or similar saw which is moved towards the wood for the purpose of cutting operation. c) Band saw means a band saw, the cutting portion of which runs in vertical direction but does not include a log saw or band resaving machine. d) Planning machine means a machine for overhand planning or thicknessing or for both operations. 2 Stopping and starting device: - An efficient stopping and starting device shall be provided on every woodworking machine. The control of this device shall be in such a position as to be readily and conveniently operated by the person in charge of the machine. 3 Space around machine: - The space surrounding every woodworking machine in motion shall be kept free from obstruction. 4 Floors:- the floor surrounding every woodworking machine shall be maintained in good and level condition, and shall not be allowed to become slippery, and as far as practicable shall be kept free from chips or other loose material, 5 Training and Supervision:- (1) No person shall be employed at a woodworking machine unless he has been sufficiently trained to under the adequate supervision of a person who has a thorough knowledge of the working of the machine. (2) A person who is being, trained to work woodworking machine shall be fully and carefully and the precautions to be observed to secure safe working of the machine. 6. Circular Saws: - Every circular saw shall be fenced as follows:- (A) Behind and in direct line with the saw there shall be a riving knife, which shall have a smooth Surface, shall be strong, rigid and easily adjustable and shall also conform to the following conditions:- (i) The edge of the knife nearer the saw shall form as are of a circle having a radius of not exceeding the radius of largest saw used on bench. (ii) The Knife shall be maintained as close as practicable to the saw, having regard to the nature of the work being done at the time and at the level of the bench table the distance between the front edge of the knife and the teeth of the saw shall not exceed 12 mm. (iii) For a saw of a diameter of less than 0.6 meter, the knife extend upwards from the bench t able to within 25 mm3 of the top of the saw, and for a saw of a diameter of 0.6 meter or over shall extend upwards from the bench teeth of the saw shall not exceed 12 mm. (B) The top of the saw shall be covered by a strong and easily adjustable guard with a flange at the side of the saw farthest from the fence. The guard shall be kept so adjusted that the said flange shall extend below the roots of the teeth of the saw. The guard shall extend from the top of the riving knife to a point as low as practicable at the cutting edge of the saw. (C) The part of the saw below the bench table shall be protected by two plates of metal or other Suitable material one on each side of the saw; such plates shall not be more than 15 cm apart, and shall extend from the axis of the outwards to a distance of not less then.5cm. Beyond the teeth of the saw- Metal plates, if not headed, shall be of a thickness of at least .25 cm. or if headed be of a thickness of at least.125 centimeters’i. 7. Push Sticks: - A push stick or other suitable appliance shall be provided for use at every circular saw and at every vertical spindle molding machine to enable the work to be done without unnecessary risk. 8. Band Saws: - Every band saw shall be guarded as follows:-  Both sides of the bottom pulley shall be completely encased by sheet or expanded metal or other suitable material.  The front of the top pulley shall be covered with sheet or expanded metal or other suitable material.  All portions of the blade shall be enclosed or otherwise securey guarded except the portion of the blade between the bench table and the top- guide. 9. Planning Machines- (I) a planning machine (other than a planning machine which is mechanically fed) shall not be used for overhand planning unless it is fitted with a cylindrical cutter block. (II) Every planning machine used for over hand planning shall be provided with a “bride” guard capable of covering the full length and breadth of the cutting slot in the bench, and so constructed as to be easily adjusted both in a vertical and horizontal director. (III) The feed roller of every planting machine used for thiknessing except the combined machine for overhand planning and thiknessing, shall be provided with an efficient guard. 10. Vertical spindle moulding machines:-  The cutter of every vertical spindle moulding machine shall be guarded by the most efficient guard having regard to the nature of the work being performed.  The wood being moulded at vertical spindle moulding shall. If practicable be held in a jig or holder of such construction as to reduce as for as possible the risk of accident to the worker. 11. Chain mortising machines: -The chain of every chain mortising machine shall be provided with a guard which shall enclose the cutters as far as practicable. 12. Adjustment and maintenance of guards. The guards and other appliances required under this Schedule shall be:- maintained in an efficient state. Constantly kept in position while the machinery in motion, and So adjusted as to enable the work to be done without unnecessary risk. 13. Exemption:- Paragraphs 6,8,9, and 10 shall not apply to an woodworking machine in respect of which it can be proved that other safeguards are provided, maintained and used which render the machine as safe as it would be if guarded in the manner prescribed in this Schedule. SCHEDULE IV (Rubber Mills) 1. Installation of machines: - Mills for breaking down, cracking, grating, mixing, refining and warming rubber or rubber compounds shall be so installed that the top of the front roll is not less than 85cm. above the floor or working level. Provided that in existing installations where the top of the front roll is below this height a strong rigid distance bar shall be fitted across the front of the machine in such position that the operator cannot reach the nip of the rolls. 2. Safety devices: - (1) Rubber Mills shall be equipped with-  Hoppers so constructed or guarded that it is impossible for the operator to come into contact in any manner with the nip of the rolls.  Horizonatal-satety trop rods or tight wire cables across both front and rear which will when pushed or pulled, operate instantly to disconnect the power and apply the brakes or to reverse the rolls. (2) Safety trip rods or tight wire cables on rubber mills shall extend across the entire length of the face of the rolls and shall be located not more than 1.75 meter above the floor or working level. (3) Safety-trip rods and tight wire cables on all rubber mills shall be examined and tested daily in the presence of the Manager or other responsible person and if any defect is disclosed by such examination and test the mill shall not be used until such defect has been remedied. SCHEDULE V (Centrifugal machines) 1. Definition: -“Centrifugal Machines” include centrifugal extractors, separators and driers. 2 Every part of a centrifugal machine shall be (a) Of good design and construction and of adequate strength; (b) Properly maintained; and (c) examined thoroughly by a competent person at regular intervals. 3. Interlocking guard for drum or basket-  The cage housing, the rotating drum or basket of every centrifugal machine shall be provided with a strong lid. The design, construction of the cage as well as the lid should be such that no access is possible to the drum or basket when the lid is closed.  Every centrifugal machine shall be provided with an efficient interlocking device that will effectively prevent the lid referred to in sub-paragraph (1) from being opened while the drum or basket is in motion and prevent the drum or basket being set in motion while the lid is in the open position. 4. Braking arrangement: -Every centrifugal machine shall be provided with an effective arrangement capable of bringing the drum or basket to rest within as short a period of time as reasonably practicable after the power is cut off. 5. Operating speed:- No centrifugal machine shall be operated at a speed in excess of the manufacturers rating which shall be legibly stamped at easily visible places both on the inside of the basket and on the outside of the machine casing. 6. Exceptions—Sub-paragraph (2) of paragraph 3, paragraphs 4 and 5 shall not apply in case of top lung machines or similar machines used in the sugar manufacturing industry. SCHEDULE VI (Powers Presses) 1. Application: - This Schedule shall apply to all types of power presses including press brakes, except when used for working hot metal. 2. Definition: -For the purpose of this Schedule,-  “ approved” means approved by the Chief inspector;  “fixed fencing” means fencing provided for the tools of a power press being fenced which has no moving part associated with or dependent upon the mechanism of a power and includes that part of a closed tool which acts as a guard;  “power press” means a machine used in metal or other industries for moulding ,pressing, blanking, raising, [ drawing and similar other purposes;  “safety device” means the fencing and any other safeguard provided for the tools of a power press. 3. Starting and stopping mechanism: - The starting and stopping mechanism shall be provided with a safety stop so as to prevent over running of the press or descent of the ram during tool shutting. etc. 4. Protection of tool and die:-  Each press shall be provided with a fixed guard with slip plate on the underside enclosing the front and all sides of the tool.  Each die shall be provided with a fixed guard surrounding its front and sides, and extending to the back in the form of a tunnel through which the pressed article falls to the rear of the press.  The design, construction and mutual position of the guards referred to in sub-Para-graphs (1) and (2) shall be such as to preclude the possibility of the worker’s hand or fingers reaching the danger zone.  The machine shall be fed through a small aperture at the bottom of the dye guard, but a wider aperture may be permitted for second or subsequent operations if feeding is done through a chute.  Notwithstanding anything contained in sub-paragraphs (1) and (2) an automatic or an interlocked guard may be used in place of a fixed guard, but where such guards are used they shall be maintained in an efficient working condition and if any guard develops a defect, the power shall not be operated unless the defect guard is removed. 5. Appointment of persons to prepare power presses for use:- (I) Except as provided in sub-paragraph (4) of paragraph 4, no person shall set, re-set, adjust or try out the tools on a power press or install or adjust any safety device thereon, being installation or adjustment preparatory to production of die proving, or carry out an inspection and test of any safety device thereon required by paragraph 8 unless he:-  has attained the age of eighteen years;  has been trained in accordance with the sub-paragraph (2); and  has been appointed by the occupier of the factory to carry out those duties in respect of the class or description of power press or the class or description of safety device, as the case may be belongs; and the name of every such person shall be entered in a register in Form 7A. (II) The training shall include suitable and sufficient practical instructions in the matter in relation to each type of power press and safety device in respect of which it is proposed to appoint the person being trained. 6. Examination and testing of power presses and safety devices: (1) No power press or safety device shall be taken into use in any factory for the first time in that factory or in case of a safety device for the first time on any power press, unless it has been thoroughly examined and tested, in the case of a power press, after installation in the factory or in the power press in connection with which it is to be used. (2) No power press shall be used unless it has been thoroughly examined and tested by a competent person within the immediately preceding period of twelve months. (3) No power press shall be used unless every safety device (other than fixed fencing) thereon has within the immediately preceding period of six months when in position on that power press, been thoroughly examined and tested by a competent person. (4) The competent person carrying out an examination and test under the foregoing provision shall make a report of examination and test containing the following particulars and every such report shall be kept readily available for inspection; (a) Name of the occupier of the factory; (b) Address of the factory; (c) Identification number or mark sufficient to identify the power press or the safety device, as the case may be; (d) Date on which the power press or the safety device was first taken into use in the factory; (e) The date of each periodical thorough examination carried out as per requirements of sub-paragraph (2) above; (f) Particulars of any defects affecting the safe working of the power press or the safety device found during such thorough examinations and steps taken to remedy such defects. 7 Defect disclosed through examination and tests:- 1. Where any defect is disclosed in any power press or in any safety device by any examination and test under paragraph 6 and in the opinion of the competent person carrying out the examination and test, either:-  the said defect is a cause of danger to workers and in consequence the power press or safety device, as the case may be ought not to be used until the said defect has been remedied; or  the said defect may become a cause of danger to workers and in consequence the power press or safety device as the case may be, ought not to be used after the expiration of a specified period unless the said defect has been remedied, such defect shall, as soon as possible after the completion of the examination and test, be notified in writing by the competent person to the occupier of the factory and in the case of a defect falling within clause (b) of this sub-paragraph, such notification shall include the period within which, in the opinion of the competent person, the defect ought to be remedied. 2. In every case where notification has been notified under this paragraph, a copy of the report made under sub-paragraph, a copy of the report made under sub-paragraph (4) of paragraph 6 shall be sent by the competent person to the inspector of the concerned area within fourteen days of the completion of the examination and test. 3. Where any such defect is notified to the occupier in accordance with the foregoing provisions of this paragraph, the power press or safety device as the case may be, having the said defect, shall not be used;  in the case of a defect falling within clause (a) of sub-paragraph (1) until the said defect has been remedied; and  in the case of defect falling within clause (b) of sub-paragraph (1) until the said defect has been remedied after the expiration of the specified period. 4. As soon as is practicable, after any defect of which notification has been notified under sub-paragraph (1), has been remedied, a record shall be made by or on behalf of the occupier stating the measures by which and the date on which the defect was remedied. 8. Inspection and test of safety devices: (1) No power press shall be used after the setting, resetting or adjustment of the tools thereon unless a person appointed or authorized for the purpose under paragraph 5 has inspected and tested every safety device thereon while it is in position on the said power press and has certified it to in order: Provided that no inspection, test and certificate shall be required where any adjustment of the tools has not caused or resulted in any alteration to or disturbance of any safety device on the power press, and, if after the adjustment of the tools, the safety device remain, in the opinion of the said person in efficient working order. (2) Every power press and every safety devices thereon while it is in position on the said power press shall be inspected and tested by a trained person every day. 9. Defects disclosed during an inspection and test:- (1) Where it appears to any person as a result of any inspection and test carried out by him under paragraph 8 that any necessary safety device is not in proper position on a power press or that any safety device which is in position on a power press, is not in his opinion suitable he shall notify the same to the manager forthwith. (2) Except as provided in sub-paragraph (3) where any defect is disclosed in a safety device any inspection and test under paragraph 8, the person carrying out the inspection and test shall notify the same to the manager forthwith. (3) Where any defect in a safety device is the subject of a notification in writing under paragraph 7 by virtue of which the use of the safety device may be continued during the specified period without the said defect having been remedied, the requirement in sub-paragraph (2) of this paragraph shall not apply to the said defect until the said period has expired. 10. Identification of power presses and safety devices: -For the purpose of identification every power press and every safety device provided for the same, shall be distinctively and plainly marked. 11. Training the instructions to operators: -The operators shall be trained and instructed in the safe method of work before starting work on any power press. 12 Exemptions:- (1) If in respect of any factory, the Chief Inspector of Factories is satisfied that owing to the circumstances or infrequency of the processes or for any other reason, all or any of the provisions of this schedule are not necessary for the protection of the workers employed on any power press or in the factory, the Chief Inspector of Factories may by a certificate in writing (which he may in his discretion revoke at any time), exempt such factory from all or ay of such provisions subject to such conditions, if any, as he may specify therein. (2) Where such exemption is granted, a legible copy of the certificate, showing the conditions if any, subject to which it has been granted, shall be kept posted in the factory on a place where it may be conveniently read by the persons employed. SCHEDULE VII (Shears Slitters and Guillotine Machines) 1. Definitions-For the purpose of this schedule:- (a) “guillotine” means a machine ordinarily equipped with straight, bevel edged blade operating Vertically against a stationery resisting edge and used for cutting metallic or non-metallic or non-metallic substances; (b) “Shears” or “shearing machine” means a machine ordinarily equipped with straight, bevel edged blades operating vertically against resisting edged, or with rotary, overlapping cutting wheels and used for shearing metals or non- metallic substances; and (c) “Slitter” or slitting machine” means a machine ordinarily equipped with circular disc-type knives, and used for trimming or cutting into metal or non- metallic substances or for slitting them into narrow strips; for the purpose of this schedule, this term includes bread or other food slices equipped with rotary knives or cutting discs. 2 Guillotine and Shears:- (I) Where practicable, a barrier metal guard of adequate strength shall be provided at the front of the knife, fastened to the machine frame and shall be so fixed as would prevent any part of the operator’s body to reach the descending blade from above, below or through the barrier guard or from the sides: Provided that in case of machines used in the paper printing and allied industries, where a fixed barrier metal guard is not suitable on account of the height and volume of the material being bed, there shall be provided suitable staring devices which require simultaneous action of both the hands of the operator or an automatic device when will remove both the hands of the operator from the danger zone at every descent of the blade. (II) At the back of such machines, an inclined guard shall be provided over which the slit pieces would slide and be collected at a safe distance in a manner as would prevent a person at the back from reaching the descending bladed (III) Power-driven guillotine cutters, except continuous feed trimmers, shall be equipped with:- (a) starting devices which require the simultaneous action of both hands to start the cutting motion and of at least one hand control during the complete stroke of the knife: or (b) an automatic guard will remove the hands of the operator from the danger zone at every decent of the blade, used in conjunction with one hand starting devices which require two distinct movements of the device to start the cutting motion, and so designed as to return positively to the non-starting position after each complete cycle of the knife. (IV) Where two or more workers are employed at the same time on the same power driven guillotine cutter equipped with two-hand control, the device shall be so arranged that each worker shall be required to use both hands simultaneously on the safety trip to start the cutting motion, and at least one hand on a control to complete the cut. (V) Power-driven guillotine cutters, other than continuous trimmer, shall be provided, in addition to the brake or other stopping mechanism, with an emergency device which will prevent the machine from operating in the event of failure of the brake when the starting mechanism is in the non-starting position. 3. Slitting Machine:- (I) Circular disc type knives on machines for cutting metal and leather, paper, rubber, textile or other non metallic substances shall, if within reach of operators standing on the floor of working level, be provided with guards enclosing the knife edges at all times as near as practicable to the surface of the material, and which may either:- (a) automatically adjust themselves to the thickness of the material; or (b) be fixed or manually adjusted so that the space between the bottom of the guard and the material will not exceed 6 mm (1/4inch) at any time. (II) Portions of blades underneath the tables or benches of slitting machines shall be covered by guards. 4. Index cutters and Vertical Paper Slotters: - Index cutter, and other machines for cutting strips from the ends of books, and for similar operations, shall be provided with fixed guards, so arranged the fingers of the operators cannot come between the blades and the tables. 5. Corner Cutters:-Corner cutters used in the manufacture of paper boxes, shall be equipped with:- (a) suitable guard, fastened to the machines in front of the knives and provided with slots or perforations to afford visibility of the operations ;or (b) other guards equally efficient for the protection of the fingers of the workers. 6. Band Knives: - Band Wheels on band knives, and all portions of the blades except the working side between the sliding guide and the table on vertical machines, or between the wheel guards on horizontal machines, shall be completely enclosed with hinged guards of sheet metal not less than 1 mm (0.04 inch) in think-ness or of other material of equal strength. SCHEDULE VIII Thermic fluid Heaters 1 All heaters shall be of such construction that coils are removal for periodic cleaning, visual inspection and hydraulic test. 2 Suitable arrangements shall be made for cooling the furnace effectively in case of power failure. 3 Before restarting the furnace, it shall be effect purged. 4 Velocity or flow of the thermic fluid shall not be allowed to fall below the minimum recommended by the manufactures while the heater is in operation. 5 The thermic fluid shall be circulated in a closed circuit formation with an expansion–cum-deaerator tank. This tank shall be located outside the shed where the heater is installed 6 Every heater shall be provided with a photo-resistor actuated auto-visual alarm to indicate flame failure and automatic burner cut 7 The stack temperature monitor-cum-controller with audiovisual alarm shall be provided so as to warn operator in case the outlet temperature exceeds the specific minimum. 8 Where inspection doors are provided on the furnace they shall be interlocked with the burner itself so that they cannot be opened until burner is shut of and furnace is cooled sufficiently. 9 All heaters shall also be provided with the following safety devices:- (i) Level control in the expansion tank (ii) temperature control of thermic fluid; (iii) differential pressure switch on the outlet line of the heater tubes; and (iv) temperature control device for the fuel oil supply to the burner. 10 All devices specified in paragraph (9) shall have interlocking arrangement with burner so that in case of any predetermined limits being crossed, the supply of fuel and air shall automatically be cut-off. 11 All safety interlock when operated shall be indicated on the control panel of the heater by a suitable audio visual alarm 12 Every heater unit shall be provided as a standard accessory an arrangement for shifting with low pressure steam or nitrogen for putting out the fire. 13 Electoral panel for the heater shall be located near the heater but not so close as to be exposed to spilling or leaking oil. 14 The heater shall be located in a place partitioned off with fire proof material from other manufacturing activities. 15 Explosion vent shall be installed that release thanks place at safe location. 16 The heater coil shall be subjected to pressure test by competent person once at least in every twelve months. The test pressure shall not be less than twice the operating pressure. 17 If repairs are carried out to the coil, it shall be tested before taking it into use. 18 The thermic fluid shall conform to the specifications specified by the manufacturers and shall be tested by competent person for suitability at least once in every three months period. Such test shall include test for acidity, suspended matter, ash contents, viscosity and flash point. 19 Cleaning of internal surface of the heater so at check up of refractory surface on the inside shall be carried out every month or as often as required depending upon working conditions. The coils shall be removed and surface of the coils cleaned thoroughly once at least in a period of six months. The burner, nozzles, oil filters and pumps shall be cleaned once a week during the period of use. 20 A separate register containing the following information shall be maintained:- (a) weekly checks carried out confirming the effectiveness of the interlock; (b) weekly checks confirming that all accessories are in good state of repairs; and (c) information regarding fuel , oil temperature, pressure, thermic fluid inlet/outlet pressure and temperature, fuel gas temperature, recorded at four hourly intervals. (21) The heater when in operation shall always be kept in charges of a trained operator.” Rule 56: [Framed U/S 23(2) of the Act] Employment of Young Persons on dangerous machines The machines specified in Sections 28, 29 and 30 and the machines mentioned below shall be deemed to be of such dangerous character that young persons shall not work at them unless the provisions of sub-section (1) of Section 23 are complied with: --- 1. Power presses other than hydraulic presses. 2. Milling machines used in the metal trades. 3. Circular saws. 4. Platen printing machines. 5. Guillotine machines. 6. Decorticater and oil expeller 7. Rubber mills. 8. Calendering machines. Rule 56A: [Framed U/S 23(2) of the Act] Water-sealed Gasholder (1) the expression "Gasholder" means a water-sealed gasholder which has a strange capacity of not less than 141.5 cubic meters (5,000 cft.) (2) Every gasholder shall be of adequate material and strength, sound construction and properly maintained. (3) Where there is more than one gasholder in the factory every gasholder shall be marked in a conspicuous position with a distinguishing number of better. (4) Every gasholder shall be thoroughly examined externally by a competent person at least once in a period of 12 months. (5) In the case of gasholder of which any lift has been in use for more than 10 years, the internal state of the sheeting shall, within one year of the coming into operation of these rules and thereafter at least every period of four years, be examined by a competent person by means of electronic or other accurate devices: Provided that if the Chief Inspector is satisfied that such electronic or other accurate devices are not available, he may permit the cutting of samples from the crown and the sides of the holder: Provided further, that if the above inspection raises a doubt, an internal visual examination shall be made. (6) All possible steps shall be repaired or demolished except under the direct supervision of a person who by his training and experience and his knowledge of the necessary precautions against risks of explosion and of persons being overcome by gas is competent to supervise such work. (7) No gasholder shall be repaired or demolished except under the direct supervision of a person who by his training and experience and his knowledge of the necessary precautions against risks of explosion and of persons being overcome by gas is competent to supervise such work. (8) (i) All samples discs cut under sub-rule (5) shall be kept readily available for inspection. (ii) A permanent register duly signed by the occupier and manager shall be maintained in Form No. 33. (iii) The result of examination by a competent person carried out under sub-rules (4) and (5) shall be in Form No. 33-A. (iv) A copy of the report in Form No. 33-A shall be kept in the register in Form No. 33 and both the register and the report shall be readily available for inspection. (9) Omitted Rule 57: [Framed U/S 26(3) of the Act] Machinery Parts to be guarded by the makers The following parts of machines will be deemed to be machinery guarded by the markers for the purpose of section 26(1) of the Act:--- (1) Back gears, change wheels and cog driver of lathes. (2) Back gear and level gearing of drilling machines. (3) Gear wheels and level drives of planning, shaping, slotting and milling machines. (4) All cog and level drives of oil expellers. (5) Beater and spikers of the as hers. (6) Blades and gear and chaff cutters. (7) Nips of rollers of rubber mixing machines. Rule 58: [Framed U/S 22(1) of the Act] Register of specially trained adult workers Registers of workers attending to machinery as provided in sub-section (1) of Section 22 of the Act shall be in Form 7-A. Rule 59: [Framed U/S 28(1) of the Act] Belts, etc., to be regularly examined All belts shall be regularly examined to ensure that the joints are safe and the belts at proper tension. Rule 60: [Framed U/S 28(1) of the Act] Examination of Hoists and Lifts (1) Examination of hoists and lifts - A register shall be maintained to record particulars of examinations of hoists and lifts in Form 23. (2) Exemption of certain hoists and lifts - In pursuance of the provisions of sub-section (4) of Section 28 of the Act in respect of any class or description of hoists or lift specified in the first column of the Schedule annexed hereto, the requirements of this section as specified in the second column of the said Schedule and set opposite to that class or description of hoists or lift shall not apply:- SCHEDULE I II Class or description Hoists or lift requirements which shall not apply Hoist or lifts mainly sub-section 1(b) in Used for raising material so far as it requires a For charging blast furnaces gate at the bottom landing Or lime-kilns sub-section (d), sub-section 1(e) Hoist not connected With mechanical power Sub-section 1 (b) in so far as And which are not it requires the hoist way or lift- Used for carrying persons way enclosure to be so const- -ructed as to prevent any person or thing from being trapped between any part of the hoist or lift and any fixed structure or moving part, subsection 1(e) Rule 60A: [Framed U/S 29(2) of the Act] Lifting machine, chains, ropes, and lifting tackles (1) No lifting machine and no chain, rope or lifting tackle, except fibre 'rope or a fibre rope sling, shall be taken into use in any factory unless it has been tested and all parts have been thoroughly examined by a competent person and certificate to that effect, specifying the safe working load or loads, has been obtained from that person and is kept available for inspection. (2) (a) Every jib-crane, which is so constructed that the safe working load varies with raising or lowering of the jib, shall have attached thereto either an automatic indicator of safe working loads or an automatic jib angle indicator and a table indicating the safe working loads at the corresponding inclinations of the jib, or corresponding radii of the load. (b) A table showing the safe working loads of every kind and size of chain, rope or lifting tackle in use, and, in the case of a multiple sling, the safe working loads at different angles of the legs, shall be posted in the store-room of place where, or in which, the chains, ropes or lifting tackles are kept, and in prominent positions, on the premises, and no rope, chain or lifting tackle, not shown in the table, shall be used. Provided that the foregoing provisions of this paragraph shall not apply in respect of such lifting tackle in the safe working load thereof, or in the case of a multiple sling, the safe working load at different angles of the legs, is plainly marked upon it. (3) (a) the register to be maintained under sub-clause (iii) of the clause (a) of sub-section (1) of Section 29 of the Act shall contain the following particulars: (i) Name of occupier of the factory. (ii) Address of the factory. (iii) Distinguishing number of mark, if any, and description sufficient to identify the lifting machine, chain, rope, or the lifting tackle. (iv) Date when the lifting machine, chain, rope, or lifting tackle was first taken into use in the factory. (v) Date and number of the certificate relating to any test and examination made under sub-rules (1) and (7) together with the name and address of the person who issued the certificate. (vi) Date of each periodical thorough examination made under-clause (iii) of clause (a) of sub- section (1) of Section 29 of the Act and sub-rule (6) any by whim it was carried out. (vii) Date of annealing or other heat treatment of the chain and other lifting tackle made under sub-rule (5) and by whom it was carried out. (viii) Particulars of any defects affecting the safe working load found at any such thorough examination or after annealing and at the step taken to remedy such defects. (b) The register shall be kept readily available for inspection. (4) All rails on which a travelling crane moves and every track on which the carriage of a transporter or runway moves shall be of proper size and adequate strength and have an even running surface and every such rail or track shall be properly laid, adequately supported and properly maintained. (5) All chains and lifting tackle except a rope sling shall, unless they have been subjected to such other heat treatment as may be approved by Chief Inspector of Factories, be effectively annealed under the supervision of a competent person at the following intervals: (i) All chains, slings, rings, hooks, shackles and swivels used in connection with molten metal or molten slag or when they are made of half inch bar or smaller once at least in every six months. (ii) All other chains, rings, hooks, shackles and swivels in general use once at least in every twelve months: Provided that chains and lifting tackle not in frequent use shall, subject to the Chief Inspector's approval be annealed only when necessary. Particulars of such annealing shall be entered in a register prescribed under sub-rule (3). (6) Nothing in the foregoing sub-rule (5) shall apply to the following classes of chains and lifting tackles: (i) Chains made of malleable cast iron. (ii) Plate link chains. (iii) Chains, rings, hooks, shackles and swivels made of steel or of any non-ferrous metal. (iv) Pitched chains, working on sprocket or pocketed wheels. (v) Rings, hooks, shackles and swivels permanently attached to pitched chains, pulley blocks or weighing machines. (vi) Hooks and swivels having screw threaded parts or ball bearing or other case hardened parts. (vii) Socket shackles secured to wire ropes by white metal capping. (viii) Bordeaux connections. Such chains and lifting tackle shall be thoroughly examined by a competent person once at lest in every twelve months, and particulars entered in the register kept in accordance with sub-rule (3). (7) Every lifting machine, chain, rope and lifting tackle, except a fibre rope, or fibre rope sling, which has been lengthened, altered or repaired by welding or otherwise shall before being again taken into use, be adequately re-tested and re-examined by a competent person and a certificate of such test and examination be obtained and particulars entered in the register kept in accordance with sub-rule (3). (8) No person under eighteen years of age and no person who is not sufficiently competent and reliable shall be employed as driver of a lifting machine, whether driven by mechanical power or otherwise, or to give signals to a driver. Rule 60B: [Framed U/S 72(3) of the Act] Passageways for cranes (1) To provide access to rail track of overhead travelling cranes suitable passageways of at least fifty centimetre (twenty inches) width with the board and double hand rails ninety centimetre (three feet) high shall be provided alongside, and clear of, the rail track of over-head travelling cranes, such that no moving part of the crane can strike persons on the ways, and the passageway shall be at a lower lever than the crane track itself. Safe access ladders shall be provided at suitable intervals to afford access to these passageways, and form passageways to the rail tracks (2) The Government may in writing exempt any existing factory form the provisions of sub-rule (1) if by virtue of the construction of the factory it is impossible to provide such a passageway. (3) The State Government may for reasons to be specified in writing, exempt any factory in respect of any overhead travelling crane form the operation of any, provision of sub-rule(1) subject to such conditions as it may specify. Rule 61: [Framed U/S 31(2) of the Act] Pressure plan.-Prescribed under sub-section(2) of section Every plant or machinery other than the working cylinders of prime movers used in a factory and operated at a pressure greater than atmospheric pressure shall be --- (a) of good construction, sound material, adequate strength and free from any patent defect ; (b) properly maintained in a safe condition; (c) Fitted with- (i) a suitable safety valve or other effective device to ensure the maximum permissible working pressure of the vessel shall not be exceeded; (ii) a suitable pressure gauge easily visible and designed to show, at all time, the correct internal pressure in kilogram per square centimetre and marked with a prominent red mark at the safe working pressure of the vessel; (iii) a suitable stop valve or valves by which the vessel may be isolated from other vessels or source of supply of pressure; and (iv) a suitable drain cock or valve at the lowest part of the vessel for the discharge of connected liquid; (d) thoroughly examined by a competent person -- (i) externally, once in every period of six months, to ensure general condition of the vessel and the working of its fitting; (ii) internally, once in every period of twelve months, to ensure condition of the walls, seams and ties both inside and outside of the vessel, soundless of the part of the vessel and the effects of corrosion. If by reason of construction of the vessel thorough internal examination is not possible this examination may be replaced by a hydraulic test which shall be carried out once in every two years : provided that for the vessels in continuous processes which can not be frequently opened, the period of internal examination may be extended to four years; and (iii) hydraulically tested at intervals of not more than four years; provided that in respect of pressure vessels with thin walls such as sizing cylinders made of copper or any other non- ferrous metal periodic hydraulic test may be dispensed with in the condition that the requirements laid down in clause (2) are fulfilled: Provided further that it shall be sufficient for the purposes of clause (c) in the safety valve, pressure gauge and stop valve mounted on a pipeline immediately adjacent to the vessel and where there is a range of two or more similar vessels in a place served by the same pressure load only one set of such mountings need be fitted provided they cannot be isolated. (2)(a) In respect of pressure vessels of thin walls such as sizing cylinders made of copper or any other non-ferrous metals, the safe working pressure shall be reduced at the rate of 5 per cent of the original working pressure for every year of its use after the first five years and no such cylinder shall be continued to be used for more than twenty years after it was first taken into use. (b) If no information as to the date of construction thickness of walls and safe working pressure is available, the age of the sizing cylinder shall be determined by the competent person in consultation with the Chief Inspector form any other particulars available with the manager. (c) Every new and second-hand cylinder of thin walls to which repairs, which may affect its working its safety have been carried out shall be tested before use to at least one and a half times its working pressure. (3) Every vessel other than a part of a prime mover operated at a pressure greater than atmospheric pressure, and not so constructed as to withstand with safety the maximum permissible working pressure at the source of supply or the maximum pressure which can be obtained in the pipe connecting the vessel with any other source of supply fitted with a suitable reducing valve or other suitable automatic device to prevent the safe working pressure of the vessel being exceeded. (4) In the cases where owing to the nature of the process or the action of the contents of the vessels, a pressure gauge or safety valve or both cannot work reliably a tested and reliable working thermometer with a sufficiently large scale, on which shall be clearly marked the maximum permissible temperature in the vessels or hygrometers or rupture disc in addition to the pressure gauge and safety valve, may be fitted as, may be directed by the Chief Inspector. (5) If during through examination a doubt arises as to ability of vessel to work safety until the next examination provided for these rules when the competent person shall enter in the register prescribed a reasoned statement, to authorise the vessel for further work subject to a lowering of pressure or to more frequent inspection or subject to both of these statement. (6) No vessel which has undergone alteration or repairs shall be taken into use unless it is thoroughly examined by a competent person. (7) A report of the result of every examination made shall be completed in Form No. 8 and signed by the person making the examination, and shall be kept available for perusal by the Inspector at any time while the vessel is in service. (8) No vessel which has previously been used shall be taken into use in any factory for the first time until it has been examined and reported in accordance with the foregoing sub-rules and no new vessel shall be taken into use unless there has been obtained from the maker of the vessel, or from a competent person, a certificate specifying the maximum permissible working pressure thereof, and stating the nature of the tests to which the vessel and its fitting (if any) has been subjected, and the certificate is kept available for perusal by an Inspector, and the vessel is so marked as to enable it to be identified as the vessel to which the certificate relates. (9) Where the report of any examination under this rule specifies conditions for securing the safe working of a vessel, the vessel shall not be used except in accordance with these conditions. (10) The competent person making the report of any examination under this rule shall within seven days of the completion of the examination, send to the Inspector a copy of the report in every case where the maximum permissible working pressure is reduced, or the report in every case where the maximum permissible working pressure is reduced, or the examination shows that the vessel cannot continue to be used with safety unless certain repairs are carried out immediately or within a specified time. (11) The requirements of this rule shall be in addition to and not in derogation of the requirements of any other Act, rules or regulations. (12) nothing in this rule shall apply to- (a) any vessel which comes within the scope of the Indian Boilers Act. (b) metal bottles of cylinder used for the storage or transport of compressed gases or liquefied or dissolved gases under pressure. (13) If the Chief Inspector of factories has reason to believe that the construction or use of pressure vessels is such that inspection is not necessary or practicable he may, subject to such conditions, if nay, exempt such pressure vessels from any or all of the provisions of this rule. Explanation. - Competent person for the purpose of Sections 28 and 29 of the Act and rules 60, 61 and 67-A shall mean a person who is a degree holder or a diploma-holder in Mechanical Engineering of recognised university or institution and has at least two years practical experience in examining testing and safe working of hoists and lifts, lifting machines and pressure vessels, and belts. Rule 62: [Framed U/S 34(2) of the Act] Excessive weights (1) No person, unaided by another person, or mechanical aid, he required or allowed to lift, put down, carry or move any load of material, article, tool or appliance exceeding the maximum limit in weight as set out in the following schedule:- SCHEDULE Person Maximum weight or material article tool or appliance (a) Adult Male 50 Kilograms (b) Adult Female 30 Kilograms (c) Young Person (Male 15-18 Years) 30 Kilograms (d) Young Person (Female 15-18 Years) 20 Kilograms (e) Young Person (Male 14-15 Years) 16 Kilograms (f) Young Person (Female 15-18 Years) 14 Kilograms (2) No woman or young person shall engage, in conjunction with others, in lifting carrying or moving any material, article tool for appliance, if the weight thereof exceeds the lowest weight fixed by the Schedule to sub-rule (1) for any of the persons engaged, multiplied by the number of the persons engaged. (3) Taking into account the conditions in which the work is to be performed, no worker shall be required or permitted to engage in the manual transport of load which, by reason of its weight, is likely to jeopardize his health or safety. (4) Wherever reasonably practicable, suitable technical devices shall be used for the manual transport of loads. Explanation: For the purposes of sub-rule (3) and (4), "Manual Transport of loads" means any transport in which the weight of the load is wholly borne by one worker, it covers the lifting and putting down of loads. (5) Notwithstanding the fact that workers are engaged in the regular "manual transport of loads" within the permissible limits as set out in sub-rule(1), they should be subjected to medical examination prior to regular assignment and periodical examination at an interval of every twelve months if the assignment of such jobs exceeds more than twelve months. Explanation: For the purpose of sub-rule (5) "Regular Manual Transport of Loads" means any activity which is continuously or principally devoted to the manually transport of Loads, or which normally includes, even through intermittently, the manual transport of loads." (Amended vide Notification No. G.S.R. 34/C.A. 63/1948/S.112/Amd. (29)/2009 dated 27th August, 2009). Rule 63: [Framed U/S 35 of the Act] Protection of eyes Effective screens or suitable goggles shall be provided for the protection of persons employed in or in the immediate vicinity of the following processes: - (a) The processes specified in Schedule 1 annexed hereto, being processes which involve risk of injury to the eyes from particles of fragments thrown off in the course of the process. (b) The processes specified in Schedule II annexed hereto, being processes which involve risk of injury to the eyes by reason of exposure to excessive light (or infra-red or ultra-violet radiations). SCHEDULE 1 (1) The breaking cutting dressing or carving of bricks, stone, concrete, slag or similar material by means of a hammer, a chisel, pick or similar hand tool, or by means of a portable tool driven by mechanical power and the dry grinding of surface of any such materials by means of a wheel or disc driven by mechanical power, where in any of the foregoing cases particles or fragments are liable to be thrown off towards the face of the operator in the course of the process. (2) The dry grinding of surface of metal by applying them by hand to a wheel, disc or hand driven by means of a portable tool driven by mechanical power. (3) The dividing into separate parts of metal, bricks, stone concrete or similar material by means of a high speed saw driven by mechanical power or by means of an abrasive cutting off wheel or disc driven by mechanical power. (4) The turning of metal, or articles of metals where particles of fragments are liable to be thrown off towards the face of the operator in the course of the process. (5) Drilling by means of portable tools, where particles or fragments are liable to be thrown off towards the face of the operator in the course of the process. (6) The welding and cutting of metal by means of an electricity oxy-acetylene of similar process. (7) The hot fettling of steel castings by means of a flux injected burner or air torch, and the deseaming of metal. (8) The fettling of metal casting involving the removal of metal, including runners, gates and risers and the removal of any other material during the course of such fettling. (9) The chipping of metal, and the chipping, knocking out, cutting our or cutting off of cold rivets bolts, nuts lugs, pins, collars or similar articles from any structure or plant or from part of any structure or plant by means of a hammer chisel, punch, or similar hand tools, or by means of a portable tool driver by mechanical power. (10) The chipping, or scuffing of paint, scale, slag, rust or other corrosion from the surface of metal and other hand materials by means of a hand tools, or by means of a portable tool driver by mechanical power. (11) The breaking of scrap metal by means of a hammer or by means of a tool driven by mechanical power. (12) The routing of metal, where particles of fragments are liable to be thrown off towards the face of the operator in the course of the process. (13) Work with drop hammers and power hammers used in either case for the manufacture of forgings, and work by any person not working with such hammers whose work is carried on in such circumstances and in such a position that particles or fragments are liable to be thrown off towards his face during work by drop hammers or power hammers. (14) Work at a furnace where there is a risk to the eyes from molten. (15) Pouring or skimming of molten metal. (16) Work involving risk to the eyes from hot sand being thrown off. (17) Turning or dressing of an abrasive wheel. (18) The handling in open vessel or manipulation of strong acids or dangerous corrosive liquids or materials and the operation, maintenance or dismantling of plant or any part of plant being plant or a part of plant which contains or has contained such acids, liquids or materials unless the plant or part of plant has been so prepared by isolation, reduction of pressure or otherwise, treated or designed or constructed so as to prevent risk or injury. (19) Any other process wherein there is risk or injury to eyes from particles or fragments thrown off during the course of the process; and SCHEDULE – II (1) Welding or cutting of metals by means of an electrical oxyacetylene or similar process. (2) All work on furnaces where there is risk of exposure to excessive light or infrared radiations. (3) Process such as rolling casting or forging of metals where there is risk of exposure to excessive light or infra red radiations. (4) Any other process wherein there is a risk of injury to eyes from exposure to excessive light or infrared ultraviolet radiations. Rule 64: [Framed U/S 36(6) of the Act] Minimum dimensions of manholes Every chamber, tank, vat, pipe, flue or other confined space which persons may have to enter and which may contain dangerous fumes to such an extent as to involve risk of the persons being overcome thereby shall unless there is other effective means of egress, be provided with a manhole which may be rectangular, oval or circular in shape, and which shall - (a) in the case of rectangular or oval shape, be not less than 40 centimeter long and 30 centimeter wide: (b) in the case of a circular shape, be not less than 40 centimeter in diameter. Rule 65: [Framed U/S 37(5) of the Act] Exemption The requirements of sub-section (4) of section 37 of the Act shall not apply to the following processes carried on in any factory: (a) The operation of repairing a water-sealed gas-holder by the electric welding process, subject to the following conditions:- (i) The gas-holder shall contain only the following gases, separately or mixed at a pressure greater than atmospheric pressure, namely, town gas, coke-oven gas, producer gas, blast furnace gas, or gases other than air used in their manufacture: Provided that this exemption shall not apply to any gas-holder containing acetylene or mixture of gases to which acetylene has been added intentionally; (ii) Welding shall only be done by the electric welding processes and shall be carried out by experienced operatives under the constant supervision of a competent person. (b) The operations of cutting or welding steel or wrought iron gas mains and services by the application of heat subject to the following conditions- (i) the main or service shall be situated in the open air, and it shall contain only the following gases, separately or mixed at a pressure greater than atmospheric pressure, namely gas, coke oven gas, producer gas, blast furnace gas, or gases other than air used in their manufacture. (ii) the main or service shall not contain acetylene or any gas or mixture of gases to which acetylene has been added intentionally; (iii) the operation shall be carried out by an experienced person or persons and at least 2 persons (including those carrying out the operations) experienced in work on gas mains and over 18 years of age shall be present during the operations; (iv) the site of the operation shall be free from any inflammable or explosive gas or vapour; (v) where acetylene gas is used as source of heat in connection with an operation, it shall be compressed and contained in a porous substance in a cylinder; and (vi) prior to the application of any flame to the gas main or service this shall be pierced or drilled and the escaping gas ignited. (c) The operation of repairing on oil tank on any ship by the electric welding process shall be subject to the following conditions- (i) the only oil contained in the tank shall have a flash point of not less than 150 degrees F (close test) and a certificate to this effect shall be obtained from a competent analyst; (ii) the analyst's certificate shall be kept available for inspection by Inspector or by any person employed or working on the ship; (iii) the welding operation shall be carried out only on the exterior surface of the tank at a place (a) which is free of oil leakage in inflammable quantities and (b) which is not less than one foot below the nearest part of the surface of the oil within the tank; and (iv) welding shall be done only by the electric welding and shall be carried out by experienced operatives under the constant supervision of a competent person. Rule 66: [Framed U/S 38(7) of the Act] Fire protection (1) Processes, equipment, plants, etc., involving serious explosion and serious fire hazards - (a) All processes, storages, equipment, plants etc. involving serious explosion and flash fire hazards shall be located in segregated buildings where the equipment shall be so arranged that only a minimum number of employees are exposed to such hazards at any one time. (b) All industrial processes involving serious fire hazards shall be located in buildings or work places separated from one another by walls of fire resistant construction. (c) Equipment and plant involving serious fire of flash fire hazards shall, wherever possible be so constructed and installed that in case of fire, they can be easily isolated. (d) Ventilation ducts, pneumatic conveyers and similar equipment involving a serious fire risk shall be provided with flame-arresting or automatic fire extinguishing appliance or fire resisting damps, electrically interlocked with heat sensitive or smoke detectors and the air conditioning plant system. (e) In all work places having serious fire or flash fire hazards, passages between machines, installations or piles of material should be at least ninety centimetres wide and for storage piles, the clearance between the ceiling and the top of the pile should not be less than two metres. (2) Access for fire fighting - (a) Building and plants shall be so laid and roads, passage-ways etc. so maintained as to permit unobstructed access for fire fighting. (b) Doors and windows opening shall be located in a suitable position on all external walls of the building to provide easy access to the entire area within the building for the fighting. (3) Protection against lighting - Protection from lighting shall be provided for- (a) buildings in which explosive or highly flammable substances are manufactured, used, handled or stored; (b) storage tanks containing oils, paints or other flammable liquid; (c) grain elevators; (d) buildings, tall chimneys or stacks where flammable gases, fumes dust or lint are likely to be present; and (e) sub-station buildings and outdoor transformers and switch-yards. (4) Precautions against ignition - Whenever there is danger of fire of explosion from accumulation of flammable or explosive substances in air- (a) all electrical apparatus shall either be excluded from the area of risk or they shall be of such construction and so installed and maintained as to prevent the danger of their being a source of ignition: (b) effective measures shall be adopted for prevention of accumulation of static charges to a dangerous extent; (c) workers shall wear shoes without iron or steel nails to cause sparks by friction; (d) smoking lighting or carrying of matches, lighters, or smoking materials shall be prohibited. (e) Transmission belts with iron fasteners shall not be used; and (f) All other precautions as are reasonably practicable, shall be taken to prevent initiation of ignition from all other possible sources such as open flames, frictional sparks, overheated surfaces of machinery or plant, chemical or physico-chemical reaction and radiant heat. (5) Spontaneous ignition - Where materials are likely to induce spontaneous ignition, care shall be taken to avoid formation of air pocket and to ensure adequate ventilation. The materials susceptible to spontaneous ignition shall be stored in dry condition and shall be in heaps of such capacity and separated by such passage which will prevent fire. The materials susceptible to ignition and store in the open shall be at a distance not less than ten metres away from process of storage building. (6) Cylinders containing compressed gas - Cylinders containing compressed gas may only be stored in open, if they are protected against excessive variation of temperature direct rays of sun or continuous dampness. Such cylinders shall never be stored near highly flammable substance furnaces, or hot processes. The room where such cylinders are stored shall have adequate ventilation. (7) Storage of flammable liquids - (a) the quantity of flammable liquids in any work room shall be the minimum required for the process or processes carried on in such room. Flammable liquids shall be stored in suitable containers with close fitting cover: Provided that not more than twenty litres of flammable liquids having a flash point of 2000 C or less shall be kept or stored in any work room. (b) Flammable liquids shall be stored in closed containers and in limited quantities in well ventilated rooms of fire resisting construction which are isolated from the remainder of the building by fire walls and self closing fire doors. (c) Large quantities of such liquids shall be stored in an isolated and adequately ventilated building of fire resisting construction or in storage tanks preferably underground and at distance from any building as required in Petroleum Rule, 1976. (d) Effective steps shall be taken to prevent leakage of such liquids into basements, sumps or drains and to confine any escaping liquid within safe limits. (8) Accumulation of flammable dust, gas, fume or vapour in air of flammable waste material on the floors - (a) Effective steps shall be taken for removal or prevention of the accumulation in the air of flammable dust gas, fume or vapour to an extent which is likely to be dangerous. (b) No waste material of a flammable nature shall be permitted to accumulate on the floors and shall be removed at least once in a day or shift and more often, when possible. Such materials shall be placed in suitable metal containers with covers wherever possible. (9) Fire exits - (a) In this rule- (i) "horizontal" means an arrangement which allows alternative egress from a floor area to another floor at or near the same level in an adjoining building or an adjoining part of the same building with adequate separation; and (ii) "travel distance" means the distance an occupant has to travel to reach an exist. (b) An exit may be a doorway, corridor, passageway to an external stairway or to a verandah or to an internal stairway segregated from the rest of building by fire resisting walls which shall provide continuous and protected means of egress to the exterior of a building or to an exterior open space. An exit may also include a horizontal exist leading to an adjoining building at the same level. (c) Lifts, escalator and revolving doors shall not be considered as exits for the purpose of this sub-rule. (d) In every room of a factory exist sufficient to permit safe escape of the occupants in case of fire or other emergency shall be provided which shall be free of any obstruction. (e) The exits shall be clearly visible and suitable illuminate with suitable arrangements irrespective of the fact that whatever artificial lighting is to be adopted for this purpose, to maintain the required illumination in case of failure of the normal source of electric supply. (f) The exist shall be marked in language understood by the majority of the workers. (g) Iron rung ladders or spiral staircases shall not be used as exit staircases. (i) Fire resisting doors or roller shutter shall be provided at appropriate places along the escape routes to prevent spread of fire and smoke, particularly at the entrance of lifts or stars where funnel or flue effect may be created inducing an upward spread of fire. (j) All exists shall provide continuous means of agrees to the exterior of a building or to an exterior open space leading to a street. (j) Exits shall be so located that the travel distance to reach at least one of them on the floor shall not exceed thirty metres. (k) In of those factories where high hazard materials are stored or used, the travel distance to the exit shall not exceed twenty-two-and-half metres and there shall be at least two ways of escape from every room, however small except toilet rooms, so located that the points of access thereto, are out of, or suitably shielded from areas of high hazard. (l) Wherever more than one exit is required for any room, space of floor exits shall be placed as remote from each other as possible and shall be arranged to provide direct access in separate direction from any point in the area served. (m) The unit of exit width used to measure capacity of any exit shall be fifty centimetres. A clear width of twenty-five centimetres shall be counted as an additional half unit. Clear width of less than twenty-five centimetres shall not be counted for exit width. (n) Occupants per unit width shall be fifty for stairs and seventy-five for doors. (o) For determining the exits required, the occupant load shall be reckoned on the basis of actual number of occupants within any floor area of ten square metres per person, whichever is more. (p) There shall not be less than two exits serving every floor area above and below the ground floor, and at least one of them shall be an internal enclosed stairway. (q) For every building of structure used for storage only, and every section thereof considered separately, shall have access to at least one exit so arranged and located as to provide suitable means of escape for any person employed therein, and in any such room wherein ten persons may be normally present, at least two separate means of exit shall be available as remote from each other as practicable. (r) Every storage area shall have access to at least one means of exit which can be readily opened. (s) Every exit doorway shall open into an enclosed stairway, a horizontal exit on a corridor or passageway providing continuous and protected means of egress. (t) No exit doorway shall be less than one hundred centimetres width. Doorways shall not be less than two hundred centimetres in height. (u) Exit doorways shall open outwards, that is, away from the room but shall not obstruct the travel along any exit. No door when opened, shall reduce the required width of stairway of landing to less than ninety centimetres. Overhead or sliding doors shall not be installed for this purpose. (v) An exit door shall not open immediately upon a flight of stair. A landing at least 1.5 metre x 1.5 metre in size shall be provided in the stairway at each doorway. (w) The exit doorways shall be openable from the side which they serve without the use of a key. (x) Exit corridors and passageways, shall be of a width not less than the aggregate required width of exit doorways leading from there in the direction of travel to the exterior. (y) Where stairways discharge through corridors and passageways, the height of the corridors and passageways shall not be less than 2.4 metres. (z) A staircase shall not be arranged round a lift shaft unless the latter is totally enclosed by a material having a fire-resistance rating not lower than that of the type of construction of the former. (aa) Hollow combustible construction shall not be permitted. (bb) The minimum width of an internal staircase shall be one hundred centimetres. (cc) The minimum width of treads without nosing shall be twenty-five centimetres for an internal staircase. The treads shall be constructed and maintained in a manner to prevent slipping. (dd) The maximum height of a riser shall be nineteen centimetres and the number of risers shall be limited to twelve per flight. (ee) Hand rails shall be provided with a minimum height of one hundred centimetres and shall be firmly supported. (ff) The use of spiral staircase shall be limited to low occupant load and to a building of height of nine metres, unless they are connected to platforms such as balconies and terraces to allow escapees to pause. A spiral staircase shall be not less three hundred centimetres in diameter and have adequate head room. (gg) The width of a horizontal exit shall be the same for the exit doorways. (hh) The floor area on the opposite of refuge side of a horizontal exit shall be sufficient to accommodate occupants of the floor areas served, allowing not less than 0.3 square metre per person. The refuge area shall be provided with exits adequate to meet the requirements of this sub-rule. At least one of the exits shall lead directly to the exterior or street. (ii) Where there is different in level between connected areas for horizontal exit, ramps not more than one in eight slope shall be provided. For this purpose steps shall not be used. (jj) Doors in horizontal exits shall be open able at all times. (kk) Ramps with a slope of not more than one in ten may be substituted for the requirements of staircase. For all slopes exceeding in ten and wherever the use is such as to involve danger of slipping, the ramp shall be surfaced with non-slipping material. (ll) In any building not provided with automatic fire alarm, a manual fire alarm system shall be provided if the total capacity of the building is over five hundred persons, or if more than twenty- five persons are employed above or below the ground floor, except that no manual fire alarm shall be required in one storey buildings where the entire area is undivided and all parts thereof are clearly visible to all occupants. (10) First-aid fire fighting arrangements - (a) in every factory there shall be provided and maintained adequate and suitable fire fighting equipment for fighting fires in the early stages, those being referred to as first-aid fire fighting equipment in this rule. (b) The types of first aid fire fighting equipment to be provided shall be determined by considering the different types of fire risks which are classified as follows. (1) "Class A fire" - Fire due to combustible materials such as wood textiles, paper, rubbish and the like; (i) "light hazard" - Occupancies like offices, assembly halls, canteens rest-rooms, ambulance room and the like; (ii) "ordinary hazard"- Occupancies like saw mills, carpentry shop, small timber yards, book binding shops, engineering workshop and the like; (iii) "extra hazard"- Occupancies like large timber yards, go downs, storing, fibrous materials, flour mills, cotton mills, jute mills, large wood working factories and the like; (2) "class B fire"- Fire in flammable liquids like oil petroleum products, solvents, grease, paint etc.; (3) "class C fire"- Fire arising out of gaseous substances; (4) "class D fire"- Fire from reactive chemicals, active metals and the like; (5) "class F fire"- Fire involving electrical equipment and delicate machinery and the like. (c) The number and types of first-aid fire fighting equipment to be provided for `light hazard' occupancy shall be as given in Schedule 1 to this rule. For `ordinary hazard' or `extra hazard' occupancies, as the case may be, equipment as given in paragraph 12 shall be provided, in addition to that given in Schedule 1 to this rule. (d) The first aid fire fighting equipment shall conform to the relevant Indian Standards. (e) As far as possible the first-aid fire fighting equipment shall be similar in shape and appearance and shall have the same method of operation. (f)) All first-aid fire fighting equipment shall be placed in a conspicuous position and shall be readily and easily accessible for immediate use. Generally, these equipments shall be placed as near as possible to the exits or stair landing or normal routes of escape. (g) All water buckets and bucket pump type extinguisher shall be filled with clean water. All sand buckets shall be filled with clean, dry and fine sand. (h) All other extinguishers shall be charged appropriately in accordance with the instructions of the manufacturer. (i) Each first-aid fire fighting equipment shall be allotted a serial number by which it shall be referred to in the records. The following details shall be pointed with white paint on the body of each equipment,- (1) Serial number; (2) Date of last refilling; and (3) Date of last inspection. (j) First-aid fire fighting equipment shall be placed on platforms or in cabinets in such a way that their bottom is seven hundred and fifty milimetres above the floor level. Fire buckets shall be placed on hooks attached to a suitable sand or wall in such a way that their bottom is seven hundred and fifty metres above the floor level. Such equipment if placed outside the building, shall be under sheds or covers. (k) All extinguishers shall be thoroughly cleaned and re-charged immediately after discharge. Sufficient refill material shall be kept readily available for this purpose at all times. (l) All first-aid fire fighting equipment shall be subjected to routine maintenance inspection, and testing to be carried out by properly trained persons. Periodicity of the routine maintenance, inspection and test shall conform to the relevant Indian Standards. (11) Other fire fighting arrangements - (a) In every factory, adequate provision of water supply for fire fighting shall be made and where the amount of water required in litres per minute, as calculated from the formula A+B+C+D divided by 20, is 550, or more power driven trailer pumps of adequate capacity to meet the requirements of water as calculated above shall be provided and maintained. In the above formula - A- the total area in square metres of all floors including galleries in all building of the factory; B- the total area in square metres of all floors and galleries including open spaces in which combustible materials are handled or stores; C- the total area in square metres of all floors over fifteen metres above ground level; and D- the total area in square metres of all floors of all buildings other than those of fire resisting construction. Provided that in areas where the fire risk involved does not required use of water, such areas under B, C or D may, for the purpose of calculation be halved: Provided further that where the areas under B, C or D are protected by permanent automatic fire fighting installation approved by any fire association or fire insurance company, such areas may, for the purpose of calculation by halved; Provided further that where the factory is situated at not more than three kilometres from an established city or town fire services, the pumping capacity based on the amount of water arrived at by the formula above, may be reduced by twenty-five per cent but no account shall be taken of this reduction in calculating water supply required under this clause. (b) Each trailer pump shall be provided with equipment as per schedule II appended to this rule. Such equipment shall conform to the relevant Indian Standards. (c) Trailers pumps shall be housed in a separate shed or sheds which shall be sited close to a principal source of water supplies in the vicinity of the main risks of the factory. (d) In factories where the area is such as cannot be reached by man hauling of trailer pumps within reasonable time, vehicles with towing, attachment shall be provided at the scale of one for every four trailer pumps with a minimum of one such vehicle kept available at all times. (e) Water supply shall be provided to give flow of water as required under clause (a) for at least one hundred minutes. At least fifty per cent of this water supply or four lac and fifty thousand litres whichever is less, shall be in the form of static tanks of adequate capacities (not less than four lac and fifty thousand litres each) distributed round the factory with due regard to the potential fire risks in the factory. Where pipes supply is provided, the size of the main shall not be less than fifteen hundred litres per minutes at a pressure of not less than seven kilograms per square centimetre. (12) Personnel in charge of equipment and for fire fighting, fire drills, etc - (a) The first-aid and other fire fighting equipment to be provided as required in sub-rules (10) and (11) shall be in the charge of a trained responsible person. (b) Sufficient number of persons shall be trained in the proper handling of fire fighting equipment as referred to in clause (a) and their use against the types of fire for which they are intended to ensure that adequate number of persons are available for fire fighting both the means of first-aid fire fighting equipment and by other means. Such persons shall be provided with clothing and equipment including helmets, belts and boots, preferably gum-boots. Wherever vehicles with towing attachment are to be provided as required in clause (d) of sub-rule (11), sufficient number of persons shall be trained in driving these vehicles to ensure that trained persons are available for driving them whenever the need arises. (c) Fire fighting drills shall be held as often as necessary and at least once in every period of two months. (13) Automatic sprinkles and fire hydrants shall be in addition and not in substitution of the requirements of sub-rules (10) and (11). (14) If the Chief Inspector is satisfied in respect of any factory or any part of the factory that owing to the exceptional circumstances such as inadequacy of water supply or infrequency of the manufacturing process or for any other reason, to be recorded in writing, all or any of the requirements of the rules are impracticable or not necessary for the protection of workers, he may be order in writing (which he may at his discretion revoke) exempt such factory or part of the factory from all or any of the provisions of the rules subject to the conditions as he may by such order impose. SCHEDULE-I FIRST-AID FIRE FIGHTING EQUIPMENTS (1) The different types of fires and fire fighting equipments suitable for use on them as under:- Class of fire Suitable type of equipment 1 2 A Fires in ordinary combustible ( wood, vegetable fibres,paper & like) Chemical extinguishers of soda-acid, gas expelled water and anti freeze types and water buckets B Fires in inflammable liquids,paints,grease,solvents and like Chemical extinguishers of foam, carbon- dioxide and dry powder types sand buckets C Fires in gaseous substances under pressure Chemical extinguishers of carbon-dioxide and dry powder types D Fires in reactive chemicals, active metals and like Special type of dry powder extinguishers and sand buckets E Fires in electric equipments Chemical extinguishers of carbon-dioxide and dry powder types sand buckets (2) One nine litres water bucket shall be provided for every one hundred square metre of the floor area or part therefore and one nine litres water type extinguisher shall be provided to six buckets or part thereof with a minimum of one extinguisher and two buckets per compartment of the buildings. Buckets may be dispensed with provided supply of extinguishers is double than that of the indicated above. (3) Acceptable replacements for water buckets and water type extinguishers in occupancies where class B fires are anticipated, are an under:- Acceptable Replacements Bucket of water Water type extinguishers For one bucket For three buckets For each nine litres (or tow gallons) extinguishers Dry sand carbon dioxide extinguishers One bucket Three kilogram (or seven pounds) Three bucket Nine kilograms or twenty pounds (in not less than two extinguishers) Nine kilogram (or twenty pounds) Dry powder Two kilogram (or five pounds) Five kilogram (or eleven pounds) In one or more extinguishers) Five kilogram (or eleven pounds) Foam extinguishers Nine litres (or two gallons) Nine litres (or two gallons Nine litres (or two gallons) (4) The following provisions shall be complied with where class E fires are anticipated: (a) For rooms containing electrical transformers: switch-gears, motors and/or other electrical apparatus only, not less than two kilograms try power or carbon dioxide type extinguishers shall be provided within fifteen metres of the apparatus. (b) Where motors and/ or other electrical equipments are installed in rooms other than those containing such equipment only one five kilogram dry powder or carbon dioxide extinguisher shall be installed within fifteen metres of such equipment in addition to the requirements mentioned in paras (3) and (4) above. For this purpose the same extinguisher may be deemed to afford protection to all apparatus within fifteen metres thereof. © Where electrical motors are installed one platforms, one, two kilogram dry powder or carbon dioxide type extinguisher shall be provided on or below each platform. In cash of a long platform with a number of motors, one extinguisher shall be acceptable as adequate for every three motors, on the common platform. The above requirements shall be in addition to the requirements mentioned in paras (3) and (4) above. (5) The first-aid fire fighting equipment shall be so distributed over the entire floor area that a person has to travel not more than fifteen metres to reach the nearest equipment. (6) Selection of sites for the installation of first aid fire fighting equipments:- (a) While selecting sites for first aid fire fighting equipment due consideration to be covered. The equipments shall be placed in conspicuous positions and shall be readily accessible for immediate use in all parts of the occupancy, It should always be borne in mind while selecting sites that first aid fire fighting equipment are intended only for use on incipient fire and their values may be negligible if the fire is not extinguished or brought under control in the early stages. (b) Buckets and extinguishers shall be placed at convenient and easily locations either on hangers or on stands in such a way that their bottom is seven hundred and fifty millimeters above ad floor level. (7) The operating instructions of the extinguishers shall not be defaced of obliterated. In case the operation instructions are obliterated or have become illegible due to passage of time, fresh transfers of the same shall be obtained from the manufacturers of the equipment sand affixed to the extinguishers. Schedule II Equipment to be provided with trailer pump (A) For light trailer pump of a capacity of six hundred and eighty litres per minute. One Armored suction hose of nine metres length, with wrenches. Two Metal suction strainers. One Basket strainer. One Two way suction collecting-head. One suction adaptor Ten Unlined or rubber lined seventy milimetres delivery house of twenty five metres length complete with quick-release couplings. One Dividing breaching – piece Two Branch-pieces with fifteen milimetres nozzles One diffuser nozzle. One standpipe with blank cap. One Hydrant key Four Collapsible canvas buckets. One fire hook (preventor) with cutting edge. One Twenty five milimetre manila rope of Thirty metres length. One Extension ladder of nine metres length (Where necessary) One Heavy axe. One spade, One Pick axe One Crowbar One Saw One Hurricane lamp One Electric torch. One pair rubber gloves. (B) For large trailer pump of a capacity of one thousand and eight hundred litres/minute. One Armored suction hose of nine metres length, with wrenches. One metal strainer. One basket strainer. One three-way suction collection head. One suction adapter. Fourteen unlined or rubber lined seventy Milimetres delivery hoses of twenty five Metres length complete with quick-release couplings One dividing breaching piece. One collecting breaching piece Four branch pipes with one twenty five Milimetre, two twenty milimetre and one Diffuser nozzle. Two standpipes with blank caps. Two hydrant keys. Six collapsible canvas buckets. One ceiling hook (preventor) with cutting edge. One fifty milimtre manilla rope of thirty metres length. One extension ladder of nine metres length (Where necessary) One heavy axe. One spade, One pick axe. One crowbar, One saw One hurricane lamp One electric torch One pair rubber gives. Note: If, it appears to the Chief Inspector of Factories that in any factory the provisions of breathing apparatus is necessary, he may, by order in writing require the occupier to provide suitable breathing apparatus in addition to the equipment for light trailer pump or large trailer pump s the case may be” Rule 66A: Building and Structures No building wall, chimney, bridge, tunnels, road, gallery, stairway, ramp, floor, platform, staging or other structure, whether of a permanent or temporary character, shall be constructed, situated or maintained in any factory, in such a manner as to cause risk of bodily injury. Rule 66B: Machinery and plant No machinery, plant or equipment shall be constructed, situated, operated or maintained in any factory in such a manner as to cause risk of bodily injury. Rule 66C: Method of work No process or work shall be carried on in any factory in such a manner as to cause risk of bodily injury. Rule 66D: Stacking and storing of materials etc No materials or equipment shall be stacked or stored in such a manner as to cause risk of bodily injury. Rule 66E: [Framed U/S 40-B (2) of the Act] (1) Safety Officer There shall be one Safety Officer for factories employing between one thousand and two thousand workers. There shall be an additional Safety Officer for every two thousand workers or a fraction thereof in excess of two thousand workers. (2) Qualifications - (a) A person shall not be eligible for appointment as a Safety Officer, unless he- (i) possesses a degree of a recognised university or institution in any branch of Engineering or Technology and has practical experience of working in a factory in a supervisory capacity for a period of not less than two years or possesses a degree in Physics or Chemistry from a recognised university or institution and has practical experience of working in a factory in a supervisory capacity for a period of not less than five years, or possesses a recognised diploma in any branch of engineering or technology and has practical experience of working in a factory in a supervisory capacity for a period of not less than five years; (ii) possesses a degree or diploma in industrial safety recognised by the State Government in this behalf; and (iii) has adequate knowledge of language spoken by majority of the workers in the region in which the factory where he is to be appointed, is situated; (b) Notwithstanding anything contained in clause (a), any person who- (i) possesses a degree or diploma in Engineering or Technology of a recognised university or institution and has experience of not less than five years in a department of the Central Government or State Government which deals with the administration of the Factory Act, 1948 or the Indian Dock Labourers Act, 1934, or (ii) possesses a degree or diploma in Engineering or Technology of a recognised university or institution and has experience of not less than five years of full time of training, education, consultancy, or research in the field of accident prevention in an industry or in any institution, shall also be eligible for appointment as a Safety Officer. Provided that the Chief Inspector may, subject to such conditions as he may specify, grant exemption from the requirements of this sub-rule, if in his opinion a suitable person possessing the necessary qualifications and experience is not available for appointment; Provided further that in the case of a person who has been working as a Safety Officer in a factory for a period of not less than three years on the date of commencement of these rules, the Chief Inspector may, subject to conditions as he may specify, relax all or any of the above said qualifications. (3) Conditions of service - (a) Where more than one Safety Officer are appointed in a factory, one of them shall be designated as the Chief Safety Officer and shall be the overall in charge of the Safety functions as envisaged in sub-rule (4). (b) The Chief Safety Officer or the Safety Officer in the case of factories where only one Safety Officer is required to be appointed, shall be given the status of a senior executive and shall work directly under the control of the Chief Executive of the factory. (c) The scales of pay and the allowances to be granted to the Safety Officers including the Chief Safety Officer, and the other conditions of their service shall be the same as those of the officers of corresponding status in the factory. (d) Against the order of dismissal or discharge a Safety officer shall have a right of appeal to the Government. (4) Duties of Safety Officer - (a) The duties of a Safety Officer shall be to advise and assist the factory management in the fulfillment of its obligations, statutory or otherwise, concerning prevention of personal injuries and maintenance of a safe working environment. (b) Without prejudice to the generality of duties in clause (a) a Safety Officer shall have the following duties, namely:- (i) to advise the concerned departments in planning and organising measures necessary for the effective control of person injuries; (ii) to advise on safety aspects in all job studies, and to carry out detailed job safety studies of selected jobs; (iii) to check and a valuate the effectiveness of the action taken or proposed to be taken to prevent personal injuries; (iv) to advise the purchase and stores departments in ensuring high quality and availability of personal protective equipment; (v) to advise on matters relating to plant safety inspections; (vi) to carry out plant safety inspections in order to observe the physical conditions of work and the work and the work practices and procedures followed by workers and to render advice on measures to be adopted for removing the unsafe physical conditions and preventing unsafe actions by workers; (vii) to tender advice on matter relating to reporting and investigation of industrial accidents and occupational diseases; (viii) to investigate accidents; (ix) to investigate the cases of occupational diseases contracted and dangerous occurrences reportable under rule 103; (x) to advise on the maintenance of such records as are necessary relating to accidents, dangerous occurrences and occupational diseases; (xi) to promote setting up of safety committees and act as advisor and convener to such committees; (xii) to organise in association with the concerned departments of the factory campaigns, competitions, contests and other activities which will develop and maintain the interest of the workers in establishing and maintaining safe conditions of work and procedures; and (xiii) to design and conduct either independently or in collaboration with the training department of the factory, suitable training and educational programmes for the prevention of personal injuries. (5) Facilities to be provided to Safety Officers - An occupier of the factory shall provide each Safety Officer with such facilities, equipment and information as are necessary to enable him to discharge his duties effectively. (6) Prohibition of performance of other duties - No Safety Officer shall be required or permitted to do any work which is inconsistent with or detrimental to the performance of the duties prescribed in sub-rule (4). Rule 66F: [Framed U/S 41-G & 112 of the Act] Safety Committee (1) In every factory,- (a) wherein two hundred and fifty or more workers are ordinarily employed; or (b) which carries on hazardous process as defined in section 2 (cb) of the Act; or (c) which carries on any manufacturing process or operation declared to be dangerous under section 87 of the Act; there shall be set up a safety committee, by the occupier. (2) The representatives of the management on Safety Committee shall include,- (a) a senior official, who by virtue of his position in the organisation can contribute effectively to the functioning of the Committee. Such a senior official shall be the Chairman of the safety Committee; (b) a Safety Officer and Factory Medical Officer, wherever available and the Safety Officer in such a case shall be Secretary of the Committee; (c) a representative each from the production, maintenance and purchase departments. (3) The workers' representatives on this Committee shall be elected by the workers. (4) The tenure of the Committee shall be two years. (5) Safety Committee shall meet as often as necessary but at least once in every quarter. The minutes of the meeting shall be recorded and produced to the Inspector on demand. (6) Safety Committee shall have the right to, - (a) ask for necessary information concerning health and safety of the workers; and (b) seek any relevant information concerning health and safety of the workers. (7) Functions and duties of the Safety Committee shall include,- (a) assisting and co-operating with the management in achieving the aims and objects outlined in the `Health and Safety Policy' of the occupier; (b) dealing with all matters concerning health safety and environment and to arrive at practicable solutions to problems encountered; (c) creating safety awareness amongst all workers; (d) undertaking educational training and promotional activities; (e) deliberating on reports of safety environmental and occupational health surveys, emergency plans, safety audits, risk assessment and implementation of the recommendations made in the reports; (f) carrying out health and safety surveys and identify causes of accidents; (g) looking into any complaint made on the likelihood of an imminent danger to the safety and health of the workers and suggest corrective measures; and (h) reviewing the implementation of the recommendations made by it. (8) Where owing to the size of the factory, or any other reason, the functions referred to in sub- rule (7) cannot be effectively carried out by the Safety Committee it may establish sub- committees as may be required to assist it." Rule 67: [Framed U/S 41 of the Act] Ladders All ladders used in replacing belts shall be specially made and reserved for that work and provided with hooks or an effective non-skid device. Ladders provided with hooks must have hooks fitted in such suitable position that they rest on the shaft when the bottom end of the ladder is resting on the floor. Rule 67A: [Framed U/S 41 of the Act] Safety belts and other safety equipment When any person is required or allowed to work at a place not affording adequate hold and foothold and from which he is liable to fall through a height of or more than 1.80 metre, he shall be provided with a safety belt fitted with leather shoulder straps of not less than 5 cm. In width with a `D Ring at the back and a rope fastened thereon. The other end of the rope shall be securely tied or hooked to same suitable rigid fixture to ensure the safety of the workers. In case it is not possible to tie or hook the other end of the rope of the safety belt to a suitable rigid fixture. The worker shall be provided with some other type of safety belt to ensure the safety of the worker. It shall be the responsibility of the occupier and manager of the Factory to ensure that every worker engaged on such operation shall use these belts and other safety equipment. These belts and other equipment shall be examined and declared fit for use every six months by a competent person. The record of examination of these belts and other equipment by the said competent person shall be maintained in a bound register which shall be produced on demand by an inspector. Rule 67B: [Framed U/S 41 of the Act] Fragile roofs - Provisions of crawling boards, etc In any factory, no person shall be required to stand or pass over or work on or near any roof or ceiling covered with fragile material through which he is liable to fall, in case it breaks or gives way, a distance of more than three metres, unless- (a) suitable and sufficient ladders, duck ladders or crawling boards, which shall be securely supported, are provided and used; and (b) a permit to work on the fragile roof is issued to him each time he is required to work thereon by a responsible person of the factory concerned. Rule 67C: [Framed U/S 41 of the Act] Electricity Rules - (1) Definitions - (a) "authorised person" means a person over 21 years of age who may be- (i) either a supplied or a consumer or (ii) a contractor for the time being under contract with the supplier or the consumer to carry out duties incidental to the generation, transformation, transmission, conversion, distribution or use of energy or (iii) any person authorised by the said supplier, consumer or contractor for the purposes specified by him, being the person who is competent to perform the duties specified in this rule and whose name has been entered in a list maintained at the office or premises of the person authorising him and giving the purposes for which such person is authorised, and the entry has been attested by the authorised person and the person authorising him; (b) "Apparatus" means electrical apparatus, and includes all apparatus machines and fitting in which conductors are use or of which they form a part; (c) "bare" means not covered with insulating material; (d) "circuit" means an electrical circuit forming a system or branch of a system; (e) "conductor" means an electrical conductor arranged to be electrically connected to a system; (f) "covered with insulating material" means adequately covered with insulating material of such quality and thickness that there is no danger; (g) "danger" means danger to health or danger to life or limb from stock, burn or other injury, to persons employed or from fire attendant upon the generation, transformation, distribution or use of electrical energy; (h) "dead" means at, or about, zero potential, and disconnected from any live system; (i) "earthed" means connected to the general mass of each in such manner as well ensure all times an immediate discharge of electrical energy without danger. (j) "live" means electrically charged; (k) "pressure" means the difference of electrical potential between any two conductors or between a conductor and each as ready by a hot wire and electrostatic voltmeter; (l) "low pressure" means a pressure in a system normally not exceeding 250 volts (where the electrical energy is used); (m) "medium pressure" means a pressure in a system normally above 250 volts but not exceeding 620 volts, where electrical energy is used; (n) "switch board" means the collection or switches or fuses, conductors and other apparatus in connection therewith, used for the purpose of controlling the current or pressure in any system or part of a system; (o) "system" means an electrical system in which all the conductors and apparatus are electrically connected to a common source of electromotive force. (2) All apparatus and conductors shall be adequate in size and power for the work they are called upon to do and so constructed, installed, protected, worked and maintained as to prevent danger so far as is reasonably practicable. (3) All accessible metallic portions of electrical plant or apparatus which though normally not (forming) of an electrical circuit, may become alive, accidentally, shall (be protected by an insulating covering or by other adequate) means or shall be connected to each by a conductor of adequate size. (4) Adequate working space and means of access, free from danger shall be provided for all apparatus which have to be worked or attended to by any person. (5) The general arrangement of switch boards shall, so far as reasonably practicable, be such that- (a) all parts which may have to be adjusted or handled are readily accessible; (b) the course of every conductor may, where necessary, be readily traced; (c) conductors arranged for connection to the same system are kept well apart, and can, where necessary, be readily distinguished; (d) all bare conductors are so placed or protected as to prevent danger from accidental short circuit. (6) Every switch board having bare conductors normally so exposed that they may be touched, shall, if not located in an area or areas set apart for the purpose thereof, where necessary be suitably fenced or enclosed. No person except an authorised person, or a person acting under his immediate supervision, shall for the purpose of carrying out his duties, have access to any part of an area so set apart. (7) Every flexible wire for portable apparatus shall be connected to the system either by efficient permanent joints or connections or by a properly constructed connector. In all cases where the person handling portable apparatus or pendent lamps with switches, is liable to get a shock through a conducting floor or conducting work or otherwise, if the metal work of the portable apparatus becomes charged, the metal work must be efficiently earthed and any flexible metallic covering of the conductor shall itself be efficiently earthed and shall not itself be the only earth connection for the metal of the apparatus. A lamp holder shall not be in metallic connection with the guard or other metal work of a portable lamp. In such places the portable apparatus and its flexible wire shall be controlled by efficient means suitably located and capable of cutting off the pressure, and the metal work shall be efficiently earthed independently of any flexible metallic cover of the conductors and any such flexible covering shall itself be independently earthed. (8) In plug and socket connection for transportable apparatus the socket shall be connected to the conductor and the plug to the appliance side. (9) Plug for connecting movable conductors shall be of such construction that they do not get in the socket connections meant for higher current. Plug and socket connection shall be of such construction that the plug cannot be inserted or withdrawn while the current is on. (10) All conductors and apparatus exposed to the weather; wet-corrosion, inflammable surroundings or explosive atmosphere, or used in any process or for any special purpose other than for lighting or power shall be so constructed or protected, and such special precautions shall be taken as maybe necessary to prevent danger in view of such exposure or use. (11) Adequate precautions shall be taken to prevent any conductor or apparatus from being accidentally or inadvertently electrically charged when persons are working thereon. (12) Instructions, both in English and in the vernacular of the district, as to the treatment of persons from electric shock, shall be affixed in all premises where electrical energy is generated, transformed, converted, switched, controlled, regulated, distributed or used. (13) Exemptions - (I) Nothing in this rule shall apply to any service lines or apparatus on the supply side of the consumer's terminal or to any chamber containing such service lines or apparatus where the supply is obtained from an outside authority; provided always that no live metal is exposed so that it may be touched. (ii) If the occupier can show, with regard to any requirements of this rule, that the special conditions in his premises are such as adequately prevent danger, that requirement shall be deemed to be satisfied and the Chief Inspector may by order in writing direct that any class to special conditions defined in the requirements of this rule adequately to prevent danger are satisfied, and may revoke such order. In particular the following shall be deemed for all the purposes of this rule adequately to prevent danger. Room in which, - (a) the floor is of wood or otherwise insulated; (b) there is no machinery or other earthed metal with which a person handling any non-earthed lamp fittings or any portably lamp is liable to be in contact; (c) no process rendering the floor wet is carried on; and (d) no live conductor is normally exposed so that it may be touched. (14) This rule shall apply to all factories. They are in addition, and not derogatory, to the Indian Electricity Act, 1910 and the Indian Electricity Rules, 1956. Rule 67D: Supply of personal protective equipment The Inspector may, having regard to the nature of the hazards involved in work and process being carried out, orders the occupier or the manager in writing to supply to the workers exposed to a particular hazard any personal protective equipment as he may deem necessary. Rule 67E: Quality of personal protective equipment all personal protective equipments provided to workers as required under any of the provisions of the Act or the rules shall have certification by Bureau of Indian Standards. Rule 67F: Examination of eye-sight of certain workers (1) No person shall be employed to operate a crane, locomotive of fork-lift truck, or to give signals to a crane or locomotive operator unless his eye-sight and colour vision has been examined and declared fit by a qualified ophthalmologist to work whether with or without the use of corrective glasses. (2) The eye-sight and colour vision of the person employed as referred to in sub-rule (1) shall be examined at least once in every period of twelve months upto the age of forty-five years and once in every six months beyond that age. (3) Any fee payable for an examination of a person under this sub-rule shall be paid by the occupier and shall be recoverable from that person. (4) The record of examination carried out as required under sub-rules (1) and (2) shall be maintained in Form 8-A. Rule 67G: Railways in factories (1) this rule shall apply to railways in the precincts of a factory which are not subject to Indian Railways Act, 1980. (2) Gateways- A gateway through which a railway track passes shall not be used for the general passage of workers into or out of a factory. (3) Barriers and Turn gates - (a) Where building or walls contain doors or gates, which open to a railway track a barrier about one metre high shall be fixed parallel to and about sixty centimetres away from the building or walls outside the opening and extending several feet beyond it at either end, so that any person passing out may become aware of an approaching train when his pace is checked at the barrier. If the traffic on the nearest track is all in one direction, the barrier shall be in the Form of "L" with the end of the short leg abutting on to the wall and the other opening towards the approaching train. (b) If the distance between wall and track cannot be made to accommodate such a barrier the barrier, or a turn gate shall be placed at the inside of the opening. (c) Where a footway passage close to a building or other obstruction as it approached a railway track a barrier or a turn gate shall be fixed in such a manner that a person approaching the track is compelled to move away from the building or obstruction and thus obtain timely sight of an approaching locomotive or wagon. (4) Crowds - (a) Workers pay windows, first aid stations and other points where a crowd may collect, shall not be placed near a railway track. (b) At any time of the day when workers are starting or ending work, all railway traffic shall cease for not less than five minutes. (5) Locomotives - (a) No locomotive shall be used in shunting operations unless it is in good working order. (b) Every locomotive and tender shall be provided with efficient brakes, all of which shall be maintained in good working order. Brake shoes shall be examined at suitably fixed intervals and those which are worn out shall be replaced at once. (c) Water-gauge glasses of every locomotive, whatever its boiler pressure may be, shall be protected with substantial glass or metal screens. (d) Suitable stops and hand-holds shall be provided at the corners of the locomotive for the use of shunters. (e) Every locomotive crane shall be provided with lifting and jacking pads at the four corners of the locomotive for assisting in re-railing operations. (f) It shall be clearly indicated on every locomotive crane in English and in the language understood by the majority of the workers in the factory, for what weight of load and at what radius the crane is safe. (6) Wagons - (a) Every wagon (and passenger coach, if any) shall be provided either with self acting brakes, capable of being applied continuously or with efficient hand brakes which shall be maintained in good working order. The brakes shall be capable of being applied by a person on the ground and fitted with a device for retaining them in the applied position. (b) No wagon shall be kept standing within three metres of any pinch bars. (7) Riding on locomotive, wagon or other rolling stock - No person shall be permitted to be upon (whether inside or outside) any locomotive wagon or after rolling stock except where secure foothold and hand are provided. (8) Attention to brakes and doors - (a) No locomotive, wagon or other rolling stock shall be kept standing unless its brakes are firmly applied and, where it is on a gradient, without sufficient number of properly constructed scotches placed firmly in position. (b) No train shall be set in motion until the shunting jamadar has satisfied himself that all wagon doors are securely fastened. (9) Projecting loads and cranes - (a) If the load on wagon projects beyond its length, a guard of dummy truck shall be used beneath the projection. (b) No loco-crane shall travel without load unless the jib is completely lowered and positioned in line with the track. (c) When it is necessary for a loco-crane to travel with a load, the jib shall not be swung until the loco-crane has come to test. (10) Loose shunting - Loose shunting shall be permitted only when it cannot be avoided. It shall never be performed on a wagon not accompanied by a man capable of applying and pinning down the brakes. A wagon not provided with brakes in good working order and capable of being easily pinned down shall not be loose shunted unless there is attached to it at least another wagon with such brakes. Loose shunting shall not be performed with, or against a wagon containing passengers, livestock or explosives. (11) Fly-shunting - Fly-shunting shall not be permitted on any factory railway. (12) The shunting jamadar - (a) every locomotive or wagon is motion in a factory shall be in charge of a properly trained jamadar. (b) Before authorising a locomotive or wagon to be moved, the shunting jamadar shall satisfy himself that no person is under or in between or in front of the locomotive or wagon. (13) Hand signals - The hand signals used by the shunting jamadar, by day and night shall be those prescribed by the shunting rules of railways, framed under the Indian Railways Act, 1890 (IX of 1890). (14) Night work and fog - (a) In factories where persons work at night, no movement of locomotive, wagon or other rolling stock otherwise than by hand shall be permitted between sunset and sunrise unless the tracks and their vicinity are lighted on a scale of not less than ten lux as measured at the horizontal plane at the ground level. (b) In no circumstances shall any locomotive or train be moved between sunset and sunrise or at any time when there is fog, unless it carried a white head light and a red rear light. (15) Speed control - (a) A locomotive or train shall not be permitted to move at a speed greater than seven kilometres per hour. (b) A train locomotive, wagon or other rolling stock shall not be moved by mechanical or electrical power unless it is preceded at a distance of not less than ten metres during the whole of its journey by a shunting jamadar. He shall be provided with signalling flags or lamp and whistle necessary for calling the attention of the driver. (16) Tracks - (a) The distance (i) between tracks, and (ii) between tracks and buildings, blind walls or other structures and (iii) between tracks and materials deposited on the ground shall respectively be not less than : (i) from centre to centre of parallel tracks, the over all width of the widest wagon of that gauge plus twice the width of the door of such a wagon when opened directly outward plus one metre. (ii) from a building or structure other than a loading platform to the centre of the nearest track, half the overall width of the widest wagon of that gauge; plus the width of its door when opened outward, plus one and a half metres. (iii) from material stacked or deposited alongside the track, on the ground or on a loading platform, to the centre of the nearest track, half the overall width of the widest wagon of that gauge ,plus half the width of its door when opened directly outward plus one metre. (b) Sleepers of a track shall be in level with the ground and at all crossings of the track with a road or walkway, the surface of the road or walkway shall be in level with the top of the rails. (c) All track ends shall be equipped with buffer stops of adequate strength. (d) Barriers of substantial constructions shall be securely and permanently fixed across and doorway or gateway in a building or in a wall which conceals an appropriating train view, between the building and the track as prescribed in clause (a) of sub-rule (3). (e) Where tracks are carried on gantry or other elevation, a footway or footways with hand rails and too-boards shall be provided at all positions where persons work or pass on foot; and where there is an opening in the stage of an elevated track for the dropping of materials to a lower level, the position shall be adequately fenced or the opening itself provided with a grill through which a person cannot fall. (f) All point levers shall have their movement parallel to not across, the direction of the track. (g) All loading platforms which are move than sixty centimetres above the level of the ground on which the track is laid and more than fifteen metres in length, shall be provided with stops at intervals not greater than fifteen metres apart to enable the platform to be easily mounted from the track. (h) Turn tables on plan railways shall be provided with locking devices which will prevent the tables from turning while locomotive or wagons are being run on or off the tables. (i) Workers shall be prohibited from passing under between or above railway wagons. (17) Crossings - (a) at all crossings of a track with a road for walkway, danger or crossing signs and wherever reasonably practicable, blinking lights or alarm lights shall be provided. At all important crossings, gates, or barriers manned by watchman shall be provided. Swinging gates and barriers shall be secured against inadvertent opening or closing. (b) All crossing, warning, signs, gates and barriers shall be illuminated during the hours of darkness. (18) Duties of drivers and shunters - It shall be the duty of every driver of a locomotive, or a shunter including a shunting jamadar to report without delay to their superior any defect in permanent way, locomotive or rolling stock. (19) Young persons not to be employed as drivers of locomotive or as shunters - No person who is below the age of eighteen years and no person who is not sufficiently competent and reliable shall be employed as a driver of a locomotive or as a shunter. (20) The Chief Inspector may by an order in writing exempt a factory or part of it from all or any of the provisions of this rule to such extent and on such conditions as he deems necessary." Rule 67H: [Framed U/S 41-A & 112 of the Act] Site Appraisal Committee (1) The following provisions shall govern the functioning of the Site Appraisal Committee (hereinafter referred to be as the "Committee") in these rules namely :- (a) The State Government may constitute or reconstitute a Site Appraisal Committee as and when necessary; (b) The State Government may appoint a senior official of the Factories Inspectorate, preferably having qualification in Chemical Engineering to be the Secretary of the Committee; (c) The State Government may appoint the following as members of the Committee, namely :- (i) a representative of the Local Government wing of the Department of Local Government, Housing and Urban Development Department of the State Government; (ii) a representative of the Department of Industries of the State Government; and (iii) a representative of the Director General of Factory Advice Service and Labour Institute, Bombay. (2) No member, unless required to do so by a court of law, shall disclose otherwise than in connection with the purposes of the Act, at any time any information relating to manufacturing or commercial business or any working process which may come to his knowledge during his tenure as a Member on this Committee. (3) Application for Appraisal of Sites :-- (a) Applications for appraisal of sites in respect of the industries covered under clause (cb) of section 2 of the Act shall be submitted to the Chairman of the Site Appraisal Committee; (b) The application for site appraisal along with fifteen copies thereof shall be submitted in Form 8-B. The Committee may dispense with furnishing of information on any particular item in the application Form,. If it considers the same to be not relevant to the application under consideration. (4) Functions of the Committee:-- (a) The Secretary shall arrange to register the applications received for appraisal of site in separate register and acknowledge the same within a period of seven days; (b) The Secretary shall fix up the meetings in such manner that all the applications received and registered are referred to the Committee within a period of one month from the date of their receipt; (c) The Committee shall adopt a procedure for its working keeping in view the need for expeditious disposal of applications; (d) The Committee shall examine the applications for appraisal of a site with reference to the prohibitions and restriction on the location of an industry and the carrying on of processes and operations in different areas as per the provisions of rule 5 of the Environment (Protection) Rules, 1986 framed under the Environment (Protection) Act, 1986; (e) The Committee may call for documents examine experts, inspect the site if necessary and take other steps for formulating its views in regard to the suitability of the site; and (f) Wherever the proposed site required clearance by the Ministry of Industries or by the Ministry Environment and Forests of Government of India, the application for Site Appraisal will be considered by the Site Appraisal Committee only after such clearance had been received. Rule 67-I: [Framed U/S 7-A,41-B & 112 of the Act] Health and Safety Policy (1) The occupier of every factory except as provided for in sub-rule (2), shall prepare a written statement of his policy in respect of health and safety of workers at work. (2) All factories : (a) covered under sub-clause (i) of clause (m) of section 2 of the Act but employing less than fifty workers; (b) covered under sub-clause (ii) of the said clause (m) but employing less than one hundred workers; shall be exempted from the requirements of sub-rule (1): Provided that the factories specified in clauses (a) and (b) above are not covered in First Schedule under clause (cb) of section 2 of the Act and are not carrying out processes or operations declared to be dangerous under section 87 of the Act. (3) Notwithstanding anything contained in sub-rule (2) the Chief Inspector may require the occupier of any of the factories or class or description of factories to comply with the requirements of the sub-rule (1) if in his opinion, it is expedient to do so. (4) The Health and Safety policy should contain or deal with:- (a) the declared intention and commitment of the top management to health, safety and environment and compliance with the relevant statutory requirements; (b) the organisational set up to carry out the declared policy clearly assigning the responsibility at different levels; and (c) arrangements for making the policy effective. (5) In particular, the policy should specify the following namely :- (a) the intentions of taking into account the health and safety performance of (b) the intentions of taking into account the health and safety performance of individuals at different levels while considering their career advancement; (c) fixing the responsibility of the contractors, sub-contractors, transporters and other agencies entering the premises; (d) providing a resume of health and safety performance of the factory in its annual report; (e) relevant techniques and methods, such as safety audits and risk assessment for periodical assessment of the status on health, safety and environment and taking all remedial measures; (f) stating its intentions to integrate health and safety in all decisions including those dealing with purchase of plant, equipment, machinery and materials as well as selection and placement of personnel; and (g) arrangements for informing educating and training and retraining its own employees at different levels and the public, wherever required. (6) A copy of the declared Health and Safety Policy duly signed by the occupier shall be made available to the Inspector having jurisdiction over the factory and to the Chief Inspector. (7) The policy shall be made widely known by :- (a) making copes available to all workers including contract workers, apprentices, transport workers and suppliers, etc., (b) displaying copies of the policy at conspicuous places, and (c) any other means of communication. (8) The occupier shall revise the Health and Safety Policy as often as may be appropriate, but it shall necessarily be revised under the following circumstances: - (a) whenever any expansion or modification having implications on safety and health of persons at work is made; or (b) whenever new substance(s) or articles are introduced in the manufacturing process having implications on health and safety of persons exposed to such substances. Rule 67J: [Framed U/S 41-B & 112 of the Act] Collection, development and dissemination of information (1) (a) The occupier or every factory carrying on a hazardous process shall arrange to obtain or develop detailed information in the form the Material Safety Data Sheet (MSDS) prescribed in Form No. 8-C in respect of every hazardous substance or material handled in the manufacture, transportation and storage in the factory. It shall be accessible upon request to a worker for reference. (b) The occupier while obtaining or developing a Material Safety Data Sheet in respect of a hazardous substance shall ensure that the information recorded accurately reflects the scientific evidence used in making that hazard determination. If he becomes newly aware of any significant information regarding the hazards, of a substance or ways to protect against the hazards, this new information shall be added to the Material Safety Data Sheet as soon as practicable. (2) Labelling. Every container of an hazardous substance shall be clearly labelled or marked to identity :- (a) the contents of the container; (b) the name and address of the manufacturer or importer of the hazardous substance; (c) the physical and health hazards; and (d) the recommended personal protective equipment needed to work safely with the hazardous substance. (3) In case a container is required to be transported by road outside the factory premises it should in addition be labelled or marked in accordance with the requirements laid down under sub-rule (2). Rule 67-K[Framed U/S 41-B & 112 of the Act] Disclosure of information to workers (1) The occupier of a factory carrying on a hazardous process shall supply to all workers the following information in relation to handling of hazardous materials o substances in the manufacture, transportation, storage and other processes :- (a) requirements of section 41-B, 41-C and 41-H of the Act; (b) a list of hazardous processes carried on in the factory; (c) location and availability of all Material Safety Data Sheets as provided in rule 67-J; (d) physical and health hazards arising from the exposure to or handling of substances; (e) measures taken by the occupier to ensure safety and control of physical and health hazards; (f) measure to be taken by the workers to ensure safe holding, storage and transportation of hazardous substances; (g) personal protective equipment required to be used by workers employed in hazardous process or dangerous operations; (h) meaning of various labels and markings used in the containers of hazardous substances as provided under rule 67-J; (i) signs and symptoms likely to be manifested on exposure to hazardous substances and to whom to report; (j) measure to be taken by the workers in case of any spillage of leakage of an hazardous substance; and (k) role of workers vis-à-vis the emergency plan of the factory in particular the evacuation procedures. (l) Any other information considered necessary by the occupier to ensure safety and health of workers. (2) The information required by sub-rule (1) shall be complied and made known to workers individually through supply of booklets of leaflets and display of cautionary notices at the work places. (3) The booklets, leaflets and the cautionary notices displayed in the factory will be in the language understood by the majority of the workers and also explained to them. (4) The Chief Inspector of factories may direct the occupier to supply further information to the workers may be deemed necessary. Rule 67-L: [Framed U/S 41-B(2) & 112 of the Act] Disclosure of information to the Chief Inspector of Factories (1) The occupier of every factory carrying on hazardous process shall furnish, in writing, to the Chief Inspector of Factories a copy of all the information furnished to the workers. (2) A copy of the Material Safety Data Sheet prescribed in Form 8-C, in respect of the hazardous substances used, produced or stored in the factory shall be furnished to the Chief Inspector of Factories. (3) The occupier shall also furnish any other information asked for by the Chief Inspector of Factories for the purpose of the Act and the rules. Rule 67-M: [Framed U/S 41-B (2) & 112 of the Act] Information on industrial wastes (1) The information furnished under rule, 67-K, and 67-L shall include the quantity of the solid and liquid wastes generated per day, their characteristics and the method of treatment such as incineration of solid wastes, chemical and biological treatment or liquids wastes, and arrangements for their final disposal. (2) It shall also include information on the quality and quantity of gaseous waste discharged through the stacks or other openings, and arrangements such as provision of scrubbers, cyclone separators, and electrostatic precipitators or similar such arrangements made for controlling pollution of the environment. (3) The occupier shall also furnish information specified in sub-rules (1) and (2) to the State Board for the prevention and Control of Water Pollution constituted under the Water (Prevention and Control of Pollution) Act, 1974 or the Air (Prevention and Control of Pollution) Act., 1891. Rule 67-N: [Framed U/S 41-B(2) & 112 of the Act] Review of the information furnished to workers etc. (1) The occupier shall review once in every calendar year and modify, if necessary, the information furnished under rules 67-K and 67-L to the workers and the Chief Inspector of Factories. (2) In the event of any change in the process or operations or methods of work or when any new substance is introduced in the process or in the event of a serious accident taking place, the information so furnished shall be reviewed and modified to the extent necessary. Rule 67-O: [Framed U/S 41-B(2) & 112 of the Act] Confidentiality of information (1) The occupier of a factory carrying on `hazardous process' shall disclose all information needed for protecting safety and health of the workers to (a) his workers; and (b) the Chief Inspector of Factories as required under rules 67-K and 67-L. If the occupier is of the opinion that the disclosure of details regarding the process and formulations will adversely affect his business interests, he may make a representation to the Chief Inspector of Factories stating the reasons for withholding such information. The Chief Inspector of Factories shall give an opportunity to the occupier of being heard and pass an order on the representation. (2) An occupier aggrieved by the order of the Chief Inspector of Factories may refer an appeal before the State Government with him a period of thirty days. The State Government shall give an opportunity to the occupier of being heard and pass an order. The order of the State Government shall be final. Rule 67-P: [Framed U/S 41-C(b) &112 of the Act] Medical Examination (1) Workers employed in an hazardous process shall be medically examined by a qualified medical practitioner (hereinafter referred to as the Factory Medical Officer), in the following manner, namely :- (a) Once before employment, to ascertain physical fitness of the person to do the particular job; (b) Once in a period of six months, to ascertain the health status of all the workers in respect of occupational health hazards to which they are exposed; and in cases where in the opinion of the Factory Medical Officer it is necessary to do so at a shorter interval in respect of any worker; and (c) The details of pre-employment and periodical medical examination carried out as aforesaid shall be recorded in the health register in Form 34. (2) No person shall be employed for the first time without a certificate of Fitness in Form 32 granted by the Factory Medical Officer. If the Factory Medical Officer declares a person unfit for being employed in any process covered under sub-rule (1), such a person shall have the right to appeal to the Inspector who shall refer the matter to the Certifying Surgeon whose opinion shall be final in this regard. If the Inspector of Factories himself is also a Certifying Surgeon, he may dispose of the application himself. (3) Any finding of the Factory Medical Officer revealing any abnormality or unsuitability of any person employed in the process shall immediately be reported to the Certifying Surgeon who shall in turn, examine the concerned worker and communicate his findings to the occupier within thirty days. If the Certifying Surgeon is of the opinion that the worker so examined is required to be taken away from the process for health protection, he will direct the occupier accordingly, who shall not employ the said worker in the same process. However the worker so taken away be provided with alternate placement unless he is fully incapacitated in the opinion of the Certifying Surgeon in which case the worker affected shall be suitably rehabilitated : Provided that the Certifying Surgeon on his own may examine any worker when he considers it necessary to do so for ascertaining the suitability of his employment in the 'hazardous process' or for ascertaining the health status of any workers. (4) The workers taken away from employment in any process under sub-rule (2) may be employed again in the same process only after obtaining the Fitness Certificate from the Certifying Surgeon and after making entries to that effect in the health register. (5) An Inspector may, if he deems it necessary to do so, refer a worker to the Certifying Surgeon for medical examination as required under sub-rule (1) or if he is Certifying Surgeon himself, conduct such medical examination. The opinion of the Certifying Surgeon in such a case shall be final. The fees required for this medical examination shall be paid by occupier. (6) The worker required to undergo medical examination under these rules and for any medical survey conducted by or on behalf of the Central or the State Government shall not refuse to undergo such medical examination. Rule 67-Q: [Framed U/S 41-C (b) of the Act] Occupational Health Centers (1) In respect of any factory carrying on hazardous process there shall be provided and maintained in good order an occupational Health Centre with the services and facilities as per scale laid down hereunder: - (a) For factories employing up to fifty workers - (i) the services of a Factory Medical Officer on retainer ship basis in his clinic to be notified by the occupier. He will carry out the pre-employment and periodical medical examination as stipulated in rule 67-P and render medical assistance during any emergency; (ii) at least five persons trained in first-aid procedures amongst whom at least one shall always be available during the working period; and (iii) a fully equipped first-aid box. (b) For factories employing fifty-one to two hundred workers- (i) an occupational health Centre having a room with a minimum floor area of fifteen square metres with floors and walls made of smooth and impervious surface and with adequate illumination and ventilation as well as equipment and with adequate illumination and ventilation as well as equipment as per the Schedule annexed to this rule; (ii) a part-time Factory Medical officer shall be in over all charge of the centre who shall visit the factory at least twice in a week and whose services shall be readily available during medical emergencies; (iii) one qualified and trained dresser-cum-compounder on duty throughout the working period; and (iv) a fully equipped first-aid box in all the departments. (c) For factories employing above two hundred workers--- (i) one full-time Factory Medical Officer for factories employing up to five hundred workers and one more medical officer for every additional one thousand workers or part thereof; (ii) an Occupational Health Centre having at least two rooms each with a minimum floor area of fifteen square metres with floor and walls made of smooth and impervious surface and adequate illumination and ventilation as well as equipment as per the Schedule annexed to this rule. (iii) There shall be one nurse, one dresser-cum compounder and one sweeper-cum-ward boy throughout the working period; and (iv) the Occupational Health Centre shall be suitably equipped to manage medical emergencies. (2) The Factory Medical Officer required to the appointed under sub-rule (1) shall have qualifications included in the Schedule to the Indian medical Degrees Act, 1916 or in the Schedules to the Indian Medical Council Act, 1956 and should possess a certificate of Training in industrial Health of minimum three months duration recognised by the State Government: Provided that- (i) a person possessing a Diploma in Industrial Health or equivalent shall not be required to possess the certificate of training as aforesaid; (ii) the Chief Inspector of Factories may, subject to such conditions as he may specify, grant exemption from the requirement of this sub-rule, if in his opinion a suitable person possessing the necessary qualification is not available for appointment; and (iii) in case of a person who has been working as Factory Medical officer for a period of not less than three years on the date of commencement of this rule, the Chief Inspector of Factories may, subject to the condition that the said person shall obtain the aforesaid certificate of training within a period of three years, relax the qualification. (3) The syllabus of the course leading to the above certificate and the organisations conducting the Sate course shall be approved by the Director General, Factory Advice Service and Labour Institute of the Government in accordance with the guidelines issued by the Director General Factory Advice Service and Labour Institute. (4) Within one month of the appointment of a Factory Medical Officer, the occupier of the factory shall furnish to the Chief Inspector the following particulars, namely:- (a) Name and address of the Factory Medical Officer; (b) Qualifications; (c) Experience, if any; and (d) The sub-rule under which appointed. SCHEDULED (See rule 67-Q (b) (i) Equipment for occupational Health Centre in Factories. 1. A glazed sink with hot and cold water always available 2. A table with a smooth top at least 180 cm.x105 cm. 3. Means for sterilizing instruments . 4. A couch. 5. Two buckets or containers with close fitting. 6. A kettle and spirits stove or other suitable means of boiling water. 7. One bottle of spirits ammoniac aromatics(120 ml) 8. Two medium size sponges. 9. Two Kidney trays. 10. Four cakes of toilet, preferably antiseptic 11 Two glass tumblers and two wine glasses 12. Two clinical thermometers. 13. Two tea spoons. 14. Two graduated (120ml) measuring glasses. 15. One wash bottle (1000 cc) for washing eyes. 16. One bottle (one litre) carbolic lotion 1 in 20. 17. Three chairs. 18. One screen. 19. One electric hand torch. 20. An adequate supply of tetanus toxied. 21. Coramine liquid (60ml.). 22. Talets-Antihistaminic, antispasmodic (25 each) 23. Syringes with needles -2 cc, and 10 cc. 24. Two needle holders big and small. 27. One dressing forceps 28. One scalpels. 29 One stethoscope. 30. Rubber bandage-pressure bandage. 31. Oxygen cylinder with necessary attachments. 32. One Blood Pressure apparatus, 33. One patellar Hammer. 34. One Peak-flow meter for lung function measurement. 35. One stomach wash set. 36. Any other equipment recommended by the Factory Medical Officer according to specific need elating to manufacturing process. 37. in addition – (1) For factories employing 51 to 200 workers- 1. Four plain wooden splints 900 mmx00 mmx6mm 2. Four plain wooden splints 50 mm x 75 mm x 6mm. 3. Twoplain wooden splints 250 mm x 50 mm x 12 mm. 4. One pair artery forceps. 5. Injections-morphia, pethidine, atropine, adrenaline, coramine, novacan (2 each). 6. One surgical scissors. (2) For factories employing above 200 workers. 1. Eight plain wooden splints 900 mm x 100 mm x 6 mm. 2. Eight plain wooden splints 350 mm x 75 mm x 6 mm. 3. Four plain wooden splints 250 mm x 50 mm x 12 mm. 4. Two pairs artery forceps. 5. Injections –morphia, pethadine, atropine , adrenaline, coramine, novacan (4each). 6. Two surgical scissors. Rule 67-R: [Framed U/S 41-C & 112 of the Act] Ambulance Van (1) In any factory carrying on hazardous process, there shall be provided and maintained I n good condition a suitably constructed ambulance van equipped with items as per sub-rule (2) and manned by a full-time Driver-cum-mechanic and helper trained in first-aid for the purposes of transportation of serious cases of accidents or sickness. The ambulance van shall not be used for any purpose other than the purpose stipulated herein and will normally be stationed at or near to the Occupational Health Centre : Provided that a factory employing less than two hundred workers may make arrangements for procuring such facility at short notice from nearby hospital or other places, to meet any emergency. (2) The ambulance should have the following equipments :-- (a) General -- -- A wheeled stretcher with folding and adjusting devices; with the head of the stretcher capable of being tilled upward; -- Fixed suction unit with equipment; -- Fixed oxygen supply with equipment; -- Pillow with case; -- Sheets; -- Blankets; -- Towels; -- Emesis bag; -- Bed Pan ; -- Urinal; -- Glass (b) Safety equipment -- -- Flares with life of thirty minutes; -- Flood lights; -- Flash lights; -- Fire extinguisher dry powder type; -- Insulated gauntlets. (c) Emergency care equipments- (i) Resuscitation -- -- Portable suction unit; Portable Oxygen units; -- Bag-valve-mask, hand operated artificial ventilation unit; -- Airways; -- Mouth gases; -- Trachestomy adoptors; -- Short spine board; -- I. V. Fluids with administration unit; -- B.P. manometer; -- Gugg; -- Stethoscope (ii) Immobilization - -- Long and short padded boards; -- Wire ladder splints; -- Triangular bandage; -- Long and short spine boards. (iii) Dressings - -- Gauze pads - 4" x 4"; -- Universal dressing 10" x 36"; -- Roll of aluminium foils; -- Adhesive tape of 3"; -- Safety pins; -- Bandage sheets; -- Burn sheet. (iv) Poisoning - -- Syrup of lpecae; -- Activated Charcoal pre-packeted in doses; -- Snake bite kit; -- Drinking water. (v) Emergency Medicines -- -- As per requirement (under the advice of Medical Officer only). Rule 67-S: [Framed U/S 41-C & 112 of the Act] Decontamination facilities In every factory carrying out `hazardous process' the following provisions shall be made to meet emergency: (a) fully equipped first aid box; (b) readily accessible means of water for washing, drenching clothing of workers as well as for those who have been contaminated with hazardous and corrosive substances and such means shall be as per scale shown in the table below:- Table ------------------------------------------------------------------------------------------------------------ No. of persons employed at any time No. of drenching showers i) Up to fifty workers 2 ii) Between fifty one to two hundred 2+1 for every additional fifty or part Workers. Thereafter. iii) Between two hundred and one to five 5+1 for every additional one hundred or Hundred workers. Part thereafter. iv) Five hundred and one workers and 8+1 for every additional two hundred or above. Part there-after. (c) a sufficient number of eye wash bottles filled with distilled water or suitable liquid, kept in boxes or cupboards conveniently situated and clearly indicated by a distinctive sign which shall be visible at all times. Rule 67-T: [Framed U/S 41-C & 112 of the Act] Making available Health Records to Workers (1) The occupier of every factory carrying out hazardous process shall make accessible the health records including the records of workers exposure to hazardous process or, as the case may be, the medical records of any worker for his perusal under the following conditions :- (a) once in every six months or immediately after the medical examination whichever is earlier; (b) if the Factory Medical Officer of the Certifying Surgeon, as the case may be, is of the opinion that the worker has manifested signs and symptoms of any notifiable disease as specified in the Third Schedule to the Act; (c) if the worker leaves the employment; (d) if any one of the following authorities so direct :-- (i) the Chief Inspector of Factories; (ii) the Health Authority of Central or State Government; (iii) Commissioner of workmen's Compensation; (iv) The Director General Employees' State Insurance Corporation; (v) The Director, Employees State Insurance Corporation (Medical benefits; and (vi) The Director General, Factory Advice Service and Labour Institutes. (2) A copy of the upto date health records including the record of worker's exposure to hazardous process or, as the case may be, the medical records shall be supplied to the worker on receipt of an application from him X-ray plates and other medical diagnostic reports may also be made available for reference to his medical practitioner. Rule 67-U: [Framed U/S 7-A, 41-B & 112 of the Act] Qualifications of Supervisors (1) All persons who are required to supervise the handling of hazardous substances shall process the following qualifications and experience: - (a) (i) A Bachelor's degree in Chemistry or Diploma in Chemical Engineering or Technology with five years experience; or (ii) A Master's Degree in Chemistry or a Degree in Chemical Engineering or Technology with two years experience. The experience stipulated above shall be in process operation and maintenance in the Chemical Industry. (2) The syllabus and duration of the above training and the organisations conducting the training shall be approved by the Director General, Factory Advice Service and Labour Institute or the State Government in accordance with the guidelines issued by the Director General, Factory Advice Service and Labour Institute. Rule 67-V: [Framed U/S 41-B & 112 of the Act] Issue of guidelines For the purpose of compliance with the requirements of sub-sections (1), (4) and (7) of section 41-B or section 41-C, the Chief Inspector of Factories may if deemed necessary, issue guidelines from time to time to the occupiers of factories carrying on `hazardous process'. Such guidelines shall be based on national Standards, Codes of Practice, or recommendations of International Bodies such as International lab our Organization and World Health Organization. CHAPTER-V WELFARE Rule 68: [Framed U/S 42 of the Act] Washing facilities (1) there shall be provided and maintained in every factory according to the nature of factory for the use of employed persons adequate and suitable facilities for washing, depending on the nature of the industry and its operations. It shall include suitable means of clearing and the facilities shall be conveniently accessible and shall be kept in orderly condition. (2) Without prejudice to the generality of the foregoing provisions the washing facilities shall be of the design standard laid down by Chief Inspector in case of each industry. (3) (a) Every container of water for washing facilities shall have a smooth, impervious surface. (b) Suitable provisions will be made for sanitary disposal of the water from washings. (4) For persons whose work involves contact with any injurious or noxious substance there shall be at least one tape of every fifteen persons. (5) If female workers are employed, separate washing facilities shall be provided and so enclosed or screened that the interiors are not visible from any place where persons of the other sex work or pass. The entrance to such facilities shall bear conspicuous notice in the language understood by the majority of the workers "For Women only" and shall also be indicated pictorially. (6) The water-supply to the washing facilities in case of industries involving contact with injurious or obnoxious substance shall be capable of yielding at least two gallons a day for each person employed in the factory and shall be from a source approved in writing by the Health Officer. Provided that where the Chief Inspector is satisfied that such a yield is not practicable he may be certificate in writing permit the supply of a smaller quantity not being less than one gallon per day for every person employed in the factory. The quantity of water required for other industries will be as approved by Chief Inspector of Factories. Rule 68A: [Framed U/S 43 of the Act] Facilities for storing and drying clothing:- All classes of factories, mentioned in the schedule annexed hereto, shall provide facilities for keeping clothing not worn during the working hours and for the drying of wet clothing. Such facilities shall include the provisions of such arrangements as are ordered by the Chief Inspector of Factories, in writing. Schedule 1. Glass Works. 2. Engineering workshops 3. Iron and Steel Works 4. Metal Foundries 5. Oil Mills 6. Chemical Works 7. Automobiles Workshops 8. Dyeing Works 9. Printing Press Rule 69: [Framed U/S 45 of the Act] First-aid appliance - The first-aid boxes or cupboards shall be distinctively marked with a red cross on white background and shall contain the following equipment :- (a) for factories in which the number of persons employed does not exceed ten or in the case of factories in which mechanical power is not used such number does not exceed fifty person :- (i) six small size sterilised dressings; (ii) three medium size sterilised dressings; (iii) three large-size sterilised dressings; (iv) three large-size sterilised burn dressings; (v) one (60 ml) bottle of Certrimide solution (1 per cent) or a suitable anti-septic solution; (vi) one (60 ml) bottle containing sal-volatile having the dose and mode of administration indicated on the label; (vii) one pair scissors; (ix) one roll of adhesive plaster (2 cms x 1 metre); (x) six pieces of sterilized eyepads in separate sealed packets; (xi) one bottle containing 100 tablets (each of 5 grains) of aspirin or any other analgesic; (xii) Polythene wash bottle (1/2 litre, i.e. 500 c.c,) for washing eyes; (xiii) one Snake-bite lancet; (xiv) one (30 ml.) bottle containing Potassium Permanganate crystals; (xv) one copy of first-aid leaflet issued by the Director-General of Factory Advice Service and Labour Institutes, Government of India, Bombay. (b) For factories in which mechanic power is used and in which the number of persons employed exceeds ten, but does not exceed fifty: (i) twelve small size sterilized dressings; (ii) six medium size sterilized dressings; (iii) six large size sterilized dressings; (iv) six large size sterilized burn dressings; (v) six (15 gm.) packets of sterilized cotton wool; (vi) one (120 ml.) bottle of certimide solution (1 per cent) or a suitable anti-septic solution; (vii) one (120 ml.) bottle of mercurochrome solution (2 per cent) in water; (viii) one (60 ml.) bottle containing sal-volatile having the dose and mode of administration indicated on the label; (ix) one pair scissors; (x) two rolls of adhesive plaster (2 cms x 1 metre); (xi) eight pieces of sterilized eye pads in separate sealed packets; (xii) one tourniquet. (xiii) one dozen safety pins; (xiv) one bottle containing 100 tablets (each of 5 grains) of aspirin or any other analgesic; (xv) one polythene wash bottle (1/2 litre, i.e. 500 cc.) for washing eyes; (xvi) one Snake-bite lancet; (xvii) one (30 ml, bottle containing Potassium Permanganate crystals,) (xviii) one copy of the First-aid leaflet issued by the Directorate General of Factory Advice Service and Labour Institutes, Government of India Bombay. (c) For factories employing more than fifty persons; (i) twenty-four small sterilized dressings; (ii) twelve medium size sterilized dressings; (iii) twelve large size sterilized dressings; (iv) twelve large size sterilized burn dressings; (v) twelve (15 gm.) packets of sterilized cotton wool; (vi) one (200 ml.) bottle of certimide solution (1 per cent) or a suitable anti-septic solution; (vii) one (200 ml.) bottle of mercurochrome solution (2 per cent) in water; (viii) one (120 ml.) bottle containing sal-volatile having the dose and mode of administration indicated on the label; (ix) one pair scissors; (x) one rolls of adhesive plaster (6 cms x 1 metre); (xi) two rolls of adhesive plaster (2 cms. X 1 metre); (xii) twelve pieces of sterilized eye pads in separate sealed packets; (xiii) one bottle containing (100 tablets each of 5 grains) of aspiring or any other analgesic; (xiv) one polythene wash bottle (500 c.c.) for washing eyes; (xv) twelve roller bandages 10 cms. Wide; (xvi) twelve roller bandages 5 cms. Wide; (xvii) six triangular bandages; (xviii) one tourniquet; (xix) suitable splints; (xx) two packets of safety pins; (xxi) kidney tray; (xxii) one snake-bite lancet; (xxiii) One (30 ml) bottle containing Potassium Permanganate crystals; (xxiv) one copy of the First-aid leaflet issued by the Directorate General of Factory Advice Service and Labour Institute, Government of India, Bombay; (xxv) One set of resuscitator (for artificial respiration.). Provided that items (xiv) to (xxi) inclusive need not be included in the standard first-aid box or cupboard., (a) where there is a property equipped ambulance room, or (b) if at least one box containing such items placed and maintained in accordance with the requirements of Section 45 of the Act is separately provided. (d) In lieu of the dressings required under items (i) and (ii) of clauses (a), (b) and (c there may be substituted adhesive wound dressings approved by the Chief Inspector and other equipment or medicines that may be considered essential and recommended by him from time to time. Rule 69-A: [Framed U/S 45 of the Act] Notice regarding first-aid A notice containing the names of the persons working within the precincts of the factory who are trained in first-aid treatment and who are in charge of the first-aid boxes or cupboards shall be pasted in every factory at a conspicuous place and near each such box or cupboard. The notice shall also indicate work room where the said person shall be available. The name of the nearest hospital and its telephone number shall also be mentioned prominently in the said notice. Rule 70: [Framed U/S 45(4) of the Act] Ambulance Room (1) Every ambulance room shall be in the charge of at least one whole-time qualified medical practitioner (hereinafter referred to as Medical Officer) assisted by at least one qualified nurse or dresser-cum-compounder and one nursing attendant, in each shift. No Medical Officer shall be required or permitted to do any work which is inconsistent with or detriment to his responsibilities. Provided that where a factory works in more than one shift, the Chief Inspector, if he is satisfied that on account of the size of factory, nature of hazardous or frequency of accidents, it is not necessary to employ a whole-time medical officer for each shift separately, he may, grant exemption from the provisions of this sub-rule and permit employment of only one whole-time Medical Officer for more than one or all shifts, subject to the conditions that- (i) there shall be no relaxation in respect of nursing staff, and (ii) the Medical Officer is readily available on call during the working hours of the factory; (iii) in sub-rule (2) the words "or dispensary" shall be omitted; and (iv) in sub-rule (3) - (i) the words "or dispensary" shall be omitted; and (ii) between the words "artificial means; and "An adequate" the words `There shall be attached to it at least one latrine and urinal of sanitary type", shall be inserted. (2) There shall be displayed in the ambulance room or dispensary a notice giving the name, address and telephone number of the medical practitioner in charge. The name of the nearest hospital and its telephone number shall also be mentioned prominently in the said notice. (3) The ambulance room or dispensary shall be separate from the rest of the factory and shall be used only for the purpose of first-aid treatment and rest. It shall have a floor area of at least 24 square metres and smooth, hard and impervious walls and floors shall be adequately ventilated and lighted by both natural and artificial means. An adequate supply of wholesome drinking water shall be laid on the room shall contain at least -- (i) A glazed sink with hot and cold water always available. (ii) A table with a smooth top at least 180 cms. X 1-5 cms. (iii) Means for sterilizing instruments. (iv) A torch. (v) Two stretchers. (vi) Two buckets or containers with close fitting lids. (vii) Two rubber hot water bags. (viii) A kettle and spirit stove or other suitable means of boiling water. (ix) Twelve plain wooden splints 900 mm x 100 mm. x 6 m; (x) Twelve plain wooden splints 320 mm. x 75 mm. x 6 m; (xi) Six plain wooden splints 250 mm. x 50 mm. x 12 mm. (xii) Six woolen blankets. (xiii) Three pairs artery forceps. (xiv) One bottle of Spiritus Ammoniac Aromaticus (120 ml.) (xv) Smelling salts (60 gms) (xvi) Two medium size sponger. (xvii) Six hand towels. (xviii) Four "Kidney" traps. (xix) Four cakes of toilet, preferably anti-septic soap. (xx) Two glass tumblers and two wing glasses. (xxi) Two clinical thermometers. (xxii) Two Tea Spoons. (xxiii) Two Graduated (120 ml.) measuring glasses, (xxiv) Two minimum measuring glasses. (xxv) One wash bottle (100 cc.) for washing eyes. (xxvi) One bottle (one litre) carbolic lotion 1 in 20. (xxvii) Three chairs. (xxviii) One screen. (xxix) One electric hand torch. (xxx) Four first-aid boxes or cupboard stocked according to the standard prescribed under clause (c) of rule 69. (xxxi) An adequate supply of anti-tetanus toxiod. (xxxii) Injection - Morphia, Pethidine, Atropine, Adrenaline, Coramine Novocam - 6 each. (xxxiii) Coramine liquid (60 ml.) (xxxiv) Tablets Antihis Taminic, Antispasmodic - 25 each (xxxv) Syringes with needles - 2 c.c, 5 c.c., 10 c.c., 50 c.c. (xxxvi) Three Surgical Scissors. (xxxvii) Needle holder. (xxxviii) Suturing needles and materials. (xxxix) Three Dissecting forceps. (xl) Three Dressing forceps. (xli) Three Scalpels. (xlii) One Stethoscope. (xliii) Rubber bandage-pressure bandage. (xliv) Oxygen cylinder with necessary attachments. (4) The occupier of every factory to which these rules apply shall for the purpose of removing serious cases of accident or sickness provide in the premises and maintain in good condition an suitable conveyance unless he has made arrangements for obtaining such a conveyance from a hospital. Explanation - For purposes of this rule, "qualified medical practitioner" means a person holding a qualification granted by an authority specified in the Schedule to the Indian Medical Degrees Act, 1916, or in the Schedules to the Indian Medical Council Act, 1956. (5) The Chief Inspector, may, by an order in writing exempt any factory from the requirements of this rule, subject to such conditions as he may specify in that order, if there is an empanelment of a hospital or nursing home of minimum twenty beds at a travel distance of not more than two kilometers from the main gate of the factory and also there is a provision of ambulance van in the premises of the factory. Rule 71: [Framed U/S 46(1) of the Act] Canteen (1) (i) Canteen or canteens shall be provided and maintained in all types of factories wherein more than two hundred and fifty workers are ordinarily employed. (2) The occupier of every factory wherein more than two hundred and fifty workers are ordinarily employed shall provide in or near the factory an adequate canteen according to the standards prescribed in these Rules. (3) The Manager of a factory shall submit for the approval of the Chief Inspector plans and site plan, in duplicate (Triplicate for Punjab) of the building toe be constructed or adapted for use as a canteen. (4) The canteen building shall be situated not less than 15 m. from any latrine, urinal, boiler house, coal stacks, ash dumps and any other source of dust, smoke or obnoxious fumes or anything which may be considered insanitary: Provided that the Chief Inspector may in any particular factory relax the provisions of this sub- rule to such extent as may be reasonable in the circumstances and may require measures to be adopted to secure the essential purpose of this sub-rule. (5) The canteen building shall be constructed in accordance with the plans approved by the Chief Inspector and shall accommodate at least a dining hall, kitchen, store-room, pantry with suitable fixtures and washing places separately for workers and for utensils. (6) In a canteen the floor and inside walls up to a height of 125 cm. from the floor shall be made of smooth and impervious materials the remaining portion of the inside walls shall be made smooth by cement plaster or any other manner approved by the Chief Inspector. (7) The doors and windows of canteen building shall be of fly-proof construction and shall allow adequate ventilation. (8) The canteen shall be sufficiently lighted at all times when any person has access to it. (9) (a) IN EVERY CANTEEN- (i) all inside walls of rooms and all ceilings and passages and staircases shall be limewashed at least once in each year of painted once in three years dating from the period when last limewashed, or painted, as the case may be; (ii) all woodwork shall be varnished o painted once in three years dating from the period when last varnished or painted; (iii) all internal structural iron and steel work be painted once in three years dating from the period when last painted. Provided that inside walls of the kitchen shall be lime or colourwashed once every four months. (b) Records of dates on which limewashing, colourwashing varnishing or painting is carried out shall be maintained in the register in Form No. 7. (10) The precinct's of canteen shall be maintain in a clean and sanitary condition. Waste water shall be carried away in covered drains of suitable design and slope so as not to allow waste water to accumulate and cause a nuisance. Suitable arrangements shall be made for the collection and disposal of garbage including provision of grease traps of adequate design. Rule 72: [Framed U/S 46(1) of the Act] Dining hall (1) The dining hall shall normally accommodate at a time 20 per cent of the workers working at the time: Provided that, in any particular factory or in any particular class of factories, the Chief Inspector by an order in writing in this behalf, after the percentage of workers to be accommodated. (2) The floor area of the dining hall, excluding the area occupied by the service counter and any furniture except tables and chairs, shall not be less than 75 square metre per diner to be accommodated as prescribed in sub-rule (1). (3) A portion of the dining hall and service counter shall be partitioned off and reserved for women workers in proportion to their number. Washing places for women shall be separate and screened to secure privacy. (4) Sufficient tables, chairs or benches shall be available for the number of diners to be accommodated as prescribed in sub-rule (1). Rule 73: [Framed U/S 46(1) of the Act] Equipment (1) There shall be provided sufficient utensils, cutlery furniture and other equipment necessary for the efficient running of the canteen. Suitable clean clothes for the employees serving in the canteen shall also be provided. (2) The furniture, utensils and other equipment shall be maintained in a clean and hygienic condition. A service counter if provided, shall have a top of smooth and impervious material. Suitable facilities including an adequate supply of hot water shall be provided for the cleaning of utensils and equipment. Rule 74: [Framed U/S 46(1) of the Act] Prices to be charged (1) Food, drink and other items served in the canteen shall be sold on a no-profit basis and the prices charged shall be subject to the approval of the Canteen Managing Committee. (1-A). In computing the prices referred to in sub-rule (1), the following items of expenditure shall not be taken into consideration, but will be borne by the occupier- (a) the rest for the land and building; (b) the depreciation and maintenance charges of the building and equipment provided for the canteen: (c) the cost of purchase, repairs and replacement of equipments including furniture, crockery, cutlery and utensils; (d) the water charges and expenses for providing lighting and ventilation: (e) the interest on the amount spent on the provision and maintenance of the building, furniture and equipment provided for the canteen." Rule 75: [Framed U/S 46(1) of the Act] Accounts (1) All book, of accounts, registers and any other documents used in connection with the running of the canteen shall be produced on demand to an Inspector. (2) The accounts pertaining to the canteen shall be audited once every twelve months by registered Accountants and Auditors and shall be submitted to the Canteen managing Committee not later than two months after the closing of the audited accounts. Provided that the accounts pertaining to the Canteen in a Government factory having its own accounts department may be audited in such department: Provided further that where the canteen is managed by a Co-operative Society registered under the Punjab Co-operative Societies Act, 1954 (Punjab Act XIV of 1955), the accounts pertaining to such canteen may be audited in accordance with the provisions of that Act. Rule 76: [Framed U/S 46(1) of the Act] Managing Committee (1) The Manager shall appoint a Canteen Managing Committee which shall be consulted from time to time as to- (a) the quality and quantity of foodstuffs to be served in the canteen; (b) the arrangements of the menus; (c) times of meals in the canteen; and (d) any other matter as may be directed by the Committee; Provided that where the Canteen is managed by a Co-operative Society registered under the Punjab Co-operative Societies Act, 1954 (Punjab Act XIV of 1955), it shall not be necessary to appoint a Canteen Managing Committee. (2) The Canteen managing Committee shall consist of an equal number of elected worker shall be in the proportion of 1 for every 1,000 workers employed in the factory provided that is no case shall be more than 5 or less than 2 workers on the Committee. (3) The Manager shall in consultation with the Works Committees, if any, determine and supervise the procedure for elections to the Canteen Managing Committee. Rule 77: [Framed U/S 46(1) of the Act] Dissolution of the Committee A canteen Managing Committee shall be dissolved by the Manager two years after the last election, no account being taken of a bye-election. Rule 77A: [Framed U/S 46(1) of the Act] Medical Examination of Canteen Staff. (1) Annual medical examination for fitness of each member of the canteen staff who handles food-stuffs shall be carried out by the Factory Medical Officer or the Certifying Surgeon which should include the following: (i) Routine blood examination. (ii) Routine and bacteriological testing of faeces and urine for germs of dysentery and typhoid fever. (iii) Any other examination including chest X-ray that may be considered necessary by the factory medical officer or the Certifying Surgeon. (2) Any person who in the opinion of the Factory Medical Officer the Certifying Surgeon is unsuitable for employment on account of possible risk to the health of others, shall not be employed as canteen staff). Section 78: [Framed U/S 47(3) of the Act] Shelters, rest rooms and lunch rooms (1) this rule shall apply to all such factories wherein more than 150 workers are employed. (2) The shelters or rest rooms and lunch rooms shall conform to the following standards and the manager of factory shall submit for the approval of the Chief Inspector a site plan in duplicate For Punjab Site plan and detailed plan in triplicate of the building to be constructed or adapted: - (a) The building shall be soundly constructed and all the walls and roof shall be of suitable heat- resisting material and shall be waterproof. The floor and walls to the height of 0.9 metre shall be so laid or finished as to provide a smooth and impervious surface. (b) The height of every room in the building shall be not less than 3.65 metre from floor level to the lowest part of the roof and there shall be at least 1.1 Sq.m. of floor area for every person employed. Provided that (i) workers who habitually go home for their meals during the rest periods may be excluded in calculating number of workers to be accommodated (ii) in the case of factories in existence at the date of commencement of the Act., where it is impracticable owing to lack of space to provide 1.1 Sq.m. of floor area for each person, such reduced floor area per person shall be provided as may be approved in writing by the Chief Inspector. (c) Effective and suitable provision shall be made in every room for securing and maintaining adequate ventilation by the circulation of fresh air and there shall also be provided and maintained sufficient and suitable natural or artificial lighting. (d) Every room shall be adequately furnished with chairs or benches with backrests. (e) Sweepers shall be employed whose primary duty is to keep the rooms buildings, and precincts thereof in a clean and tidy condition. (f) Suitable provisions shall be made in every room for supply of drinking water and facilities for washing. (3) (a) The lunch rooms shall comply with the requirements laid down in clauses (a) to (f) of sub- rule (2). (b) Every lunch room shall be provided with adequate number of tables with impervious tops and suitable benches or chairs for use of workers for taking food. Adequate means for warming food shall also be made. Rule 79: [Framed U/S 48(3) of the Act] Creches (1) In every factory wherein more than Thirty women workers are ordinarily employed the crèches shall be conveniently accessible to the mothers of the children accommodated therein and so far as reasonably practicable shall not be situated in close proximity to any part of the factory where obnoxious fumes, dust or odours are given off or in which excessively noisy processes are carried on. (2) The building in which creche is situated shall be soundly constructed and all the walls and roof shall be of suitable heat-resisting materials and shall be waterproof. The floor and internal walls of the creche shall be so laid or furnished as to provide a smooth impervious surface. (3) The height of the rooms in the building shall be not less than 65 cm from the floor to the lowest part of the roof and there shall be not less than 1.86 square metre of floor area for each child to be accommodated. (4) Effective and suitable provision shall be made in every part of the creche for adequate ventilation by the circulation of fresh air. (5) The creche shall be adequately furnished and equipped and in particular there shall be one suitable cot or cradle with the necessary bedding for each child (provided that for children over two years of age it will be sufficient if suitable bedding is made available) at least on chair or equivalent seating accommodation for the use of each mother while she is feeding or attending to her child, and a sufficient supply of suitable toys for the older children. (6) A suitable fenced and shady open air play-ground shall be provided for the older children: Provided that the Chief Inspector may by order in writing exempt any factory from compliance with this sub-rule if he is satisfied that there is no sufficient space available for the provision of such a play-ground. (7) The occupier of every factory shall provide for facilities for the mothers of children to feed them at regular intervals. Rule 80: [Framed U/S 48(3) of the Act] Wash-room (1) There shall be in or adjoining the creche a suitable wash-room for the washing of the children and their clothing. The wash-room shall conform to the following standards: - (a) The floor and internal walls of the room to the height of 0.9 metre shall be so laid or furnished as to provide a smooth impervious surface. The room shall be adequately lighted and ventilated and the floor shall be effectively drained and maintained in a clean and tidy condition. (b) There shall be at least one basin or similar vessel for every four children accommodated in the creche at any one time together with a supply of water provided if practicable through taps from source approved by the health Officer. Such source shall be capable of yielding for each child a supply of at least five gallons of water a day. (c) An adequate supply of clean clothes, soap and clean towels shall be made available for each child while it is in the creche. (2) Adjoining the wash-room referred to above, latrine shall be provided for the sole use of the children in the creche. The design of the latrine and the scale of accommodation to be provided shall either be approved by the Public Health Authorities, or where there is no such authority, by the Chief Inspector of Factories. Rule 81: [Framed U/S 48(3) of the Act] Supply of milk and refreshment At least half of pint of pure milk shall be available for each child on every day it is accommodated in the creche and the mother of such a child shall be allowed in the course of her daily work, two intervals of at least 15 minutes to feed the child. For children above two years of age there shall be provided in addition an adequate supply of wholesome refreshment. Rule 82: [Framed U/S 48(3) of the Act] Clothes for crèche staff The creche staff shall be provided with suitable clean clothes for use while on duty in the creche. Rule 82A: [Framed U/S 48(3) of the Act] Exemption from the provision of creche (1) In factories where the number of married women or widows employed does not exceed fifteen or where the factory works for less than one hundred and eighty days in a calendar year, or where the number of children kept in the creche was less than five in the preceding year, the Chief Inspector of Factories may exempt such factories from the provisions of section 48 and the rules 79 to 82 of these rules, if he is satisfied that alternate arrangements as specified in sub- rule (2) are provided by the factory. (2) (a) The alternate arrangements required in sub-rule (1) shall include a creche building which has a minimum accommodation at the rate of 1.85 square metres per child and constructed in accordance with the plans approved by the Chief Inspector of Factories; (b) The creche building shall have-- (i) a suitable washroom for washing of the children and their clothing; (ii) adequate supply of soap and clean clothes and towels; and (iii) adequate number of female attendants who are provided with suitable clean clothes for use while on duty to look after the children in the creche. (3) The exemption granted under sub-rule (1) may at any time be withdrawn by the Chief Inspector of Factories if he finds after such enquiry as he may deem fit, that the factory has committed a breach of this rule." CHAPTER-VI WORKING HOURS OF ADULTS Rule 83: [Framed U/S 53(1) of the Act] Compensatory holidays (1) Except in the case of workers engaged in any work for which for technical reasons must be carried on continuously throughout the day, the compensatory holidays to be allowed under sub- section (1) of Section 52 of the Act shall be so spaced that not more than two holidays are given in one week. (2) The Manager of the factory shall display, on or before the end of the month in which holidays are lost, a notice in respect of workers allowed compensatory holidays during the following month and of the dates thereof, at the place at which the notice of periods of work prescribed under Section 61 of the Act is displayed. Any subsequent change in the notice in respect of any compensatory holiday shall be made not less than three days in advance of the date of that holiday. (3) Any compensatory holiday or holidays to which a worker is entitled shall be given to him before he is discharged or dismissed and shall not be reckoned as part of any period of notice required to be given before discharge or dismissal. (4) (a) The Manager shall maintain a Register in Form No 9. Provided that if the Chief Inspector of Factories is of the opinion that any muster-roll or register maintained as part of routine of the factory or return made by the Manager, gives in respect of any or all of the workers in the factory the particulars required for the enforcement of Section 52, he may, by order in writing, direct that such muster-roll or register or return shall, to the corresponding extent, be maintained in place of and be treated as the register of return required under this rule, for that factory. (b) The register maintained under clause (a) shall be preserved for a period of three years after the last entry in it and shall be produced before the Inspector on demand. Rule 84: [Framed U/S 58(2) of the Act] Exemption for printing presses. All Printing Presses attached to daily newspapers publishing more than one edition shall be exempted from the provisions of sub-section (1) of Section 58 of the Act subject to the condition that the system of overlapping shifts is duly approved by the Chief Inspector of Factories before hand and no worker is made to work more than nine hours a day subject to forty-eight hours a week as provided under Section 51 of the Act. Rule 85: [Framed U/S 59(5) of the Act] Muster-roll for exempted factories (1) The Manager of every factory in which workers are exempted under Section 64 or 65 from the provisions of Section 51 or 54 shall keep a muster-roll in Form No. 10 showing the normal piece-work rate of pay, or the late or pay per hour, of all exempted employees. In this muster-roll shall be correctly entered the overtime hours of work and payments therefore of all exempted workers. The muster-roll in Form No. 10 shall always be available for inspection. (2) Period of overtime work shall also be entered in overtime slips which shall be prepared in duplicate and an overtime slip duly signed by the Manager or by a person duly authorised by him shall be given to the worker immediately after completion of the overtime work. "Provided that if the Chief Inspector is satisfied that it is not possible to issue daily slips to the workers due to the nature of work carried out by a worker in the factory, he may permit to issue weekly slips in duplicate duly signed by the Manager or by a person duly authorized by him after completion of the work specified therein." Rule 85A: [Framed U/S 59(5) of the Act] Extra wages for overtime For the purpose of computing cash equivalent of the advantage accruing through the concessional sale to a worker of foodgrains and other articles, the difference between the value of foodgrains and articles at the average rates in the nearest market prevailing during the wage food period in which overtime was worked and value of foodgrains and other articles supplied at concessional rates shall be calculated and allowed for the number of overtime hours worked: Provided that this rule shall not apply to any Federal Railway Factory whose alternative method of compensation has been approved by the State Government. Rule 86: [Framed U/S 61(8) of the Act] Register of Adult Workers the Register of periods of work for adult workers shall be in Form No. 11. Rule 87: [Framed U/S 62(2) of the Act] Register of adult workers The Register of adult workers shall be in Form No. 12. Rule 88: ---- Rule 89: ---- Rule 90: ----- Rule 91: ----- CHAPTER-VII EMPLOYEMENT OF YOUNG PERSONS Rule 92: [Framed U/S 72(3) of the Act] Notice of periods of work of children the notice of periods of work for child workers shall be in Form No. 13. Rule 93: [Framed U/S 73(2) of the Act] Register of child workers The Register of child workers shall be in Form No. 14. CHAPTER-VIII LEAVE WITH WAGES Rule 94: [Framed U/S 80(3) of the Act] Wages during leave period The cash equivalent of the advantage accruing thorough the concessional sale of foodgrains and other articles payable to workers proceeding on leave shall be the difference between the value at the average rates in the nearest market prevailing during the month immediately preceding his leave and the value at the concessional rates allowed foodgrains and other articles he is entitled to. For the purposes of the cash equivalent monthly average market rates of foodgrains and other articles shall be computed at the end of every month. Rule 94A: [Framed U/S 83 of the Act] Leave with wages register (1) The manager shall maintain a register in Form No., 15 (hereinafter called the leave with wages register) and the name of each worker shall be entered in this register before the close of the next calendar month following the month, in which the workers is taken in employment. Provided that if Chief Inspector is of the opinion that any muster-roll or register or any other record maintained as part of the routine of the factory, or return made by the manager gives in respect of any or all the workers in the factory, the particulars required for the enforcement of Chapter VIII of the Act, he may, by order in writing, direct that such muster-roll or register or return shall, to the corresponding extent, the maintained in place of and be treated as the register or return required under this rule in respect of the factory. (2) The leave with wages register shall be preserved for a period of three years after the last entry in it and shall be produced before the Inspector on demand. Rule 95: [Framed U/S 83 of the Act] Leave Book (1) The Manager shall provide each worker with a book in Form No. 15 (hereinafter called the leave book) within one month following the month in which the worker is taken in employment. The leave book shall be the property of the worker and the manager or his agent shall not demand it except to make relevant entries therein whenever necessary, and shall not keep it for more than a week at a time. (2) If a worker loses his leave book, the manager shall provide him with another copy on payment of 15 Paise duly completed from his record within a week of the payment. Rule 96: [Framed U/S 83 of the Act] Medical Certificate If any worker is absent from work due to his illness and he wants to avail himself of the leave with wages due to him to cover the whole or part of the period of his illness under the provisions of clause (7) of Section 79 of Chapter VIII of the Act as revised by the Factories (Amendment) Act, 1954 he shall, if required by the manager, produce a medical certificate signed by a registered medical practitioner or by a registered or recognised Vaid or hakim stating the cause of the absence and the period for which the worker is, in the opinion of such medical practitioner, Vaid or hakim, unable to attend his work, or other reliable evidence to prove that he was actually ill during the period for which the leave is to be availed of. Rule 97: [Framed U/S 83 of the Act] Notice to Inspector of involuntary unemployment The manager shall give as soon as possible a notice to the Inspector of every case of involuntary unemployment of workers, giving numbers of unemployed and the reason for their unemployment. Entries to this effect shall be made in the Leave with Wages Register and the Leave Book in respect of each worker concerned. Rule 98: [Framed U/S 83 of the Act] Notice by worker Before or at the end of every calendar year, a worker, who may be required to avail to leave in accordance with sub-section (8) of Section 79 of the Act may give notice to the Manager of his intention not to avail himself of the leave with wages falling due during the following calendar year. The Manager shall make an entry to that effect in the Leave the Wages Register and in the Leave Book of the Worker concerned. Rule 99: [Framed U/S 83 of the Act] Notice of leave with wages (1) As far as circumstances permit, members of the same family, comprising husband, wife and children shall be allowed leave on the same date. (2) A worker may exchange the period of his leave with another worker, subject to the approval of the Manager. Rule 100: [Framed U/S 83 of the Act] Payment of wages if the worker dies If a worker dies before he resumes work, the balance of his pay due for the period of leave with wages not availed of shall be paid to his nominee within one week of the intimation of the death of the worker. For this purpose each worker shall submit a nomination in Form No. D annexed hereto duly signed by himself and attested by two witnesses. The nomination shall remain in force until it is cancelled or revised by another nomination.

Previous and next

All provisions of Punjab Factory Rules 1952

Questions people ask

Is rule 29 of Punjab Factory Rules 1952 still in force?

No repeal of Punjab Factory Rules 1952 is recorded.